3 <br />3 <br />FLOOR PLAN <br />9 <br />37 <br />PROPOSED NEW 2x4 EXTERIOR WALLS <br />PROPOSED NEW INTERIOR WALLS <br />DATA OUTLET <br />RECESSED DIRECTIONAL <br />SURFACE MOUNTED <br />"CASABLANCA" TYPE <br />RECESSED <br />WALL MOUNTED <br />SURFACE MOUNTED <br />50 CFM RECESSED EXHAUST FAN <br />ON BATH & LAUNDRY & 250 CFM ON KITCHEN <br />OR 160 CFM IF ELECTRIC <br />VENTED TO THE EXTERIOR <br />CEILING FAN <br />DUPLEX OUTLET <br />CEILING MOUNTED <br />FLUSH FLOOR MOUNTED <br />DUPLEX OUTLET GFCI <br />220V OUTLET <br />TELEPHONE OUTLET <br />TELEVISION OUTLET <br />110 VOLT SMOKE DETECTOR <br />(SEE "GENERAL NOTES" <br />FOR OTHER SPEC'S) <br />SPEAKER LOCATION <br />OUTLET (VERIFY LOC.) <br />THE LIGHTS SHALL BE <br />HIGH EFFICACY AND <br />CONTROLLED BY A <br />DIMMER/VACANCY <br />SENSOR/MOTION & <br />PHOTO CONTROL <br />(AS APPLICABLE) SEE PLAN <br />EXTERIOR <br />LIGHT <br />CARBON MONOXIDE <br />ALARMCMA <br />WHERE MORE THAN ONE SMOKE ALARM <br />IS REQUIRED TO BE INSTALLED IN SUCH <br />A MANNER THAT THE ACTIVATION OF ONE <br />ALARM WILL ACTIVATE ALL OF THE ALARMS. <br />AT LEAST ONE 20 AMP BRANCH CIRCUIT <br />SHALL BE PROVIDED TO SUPPLY LAUNDRY <br />RECEPTACLES OUTLETS. SUCH CIRCUITS <br />SHALL HAVE NO OTHER OUTLETS <br />LIGHTING IN BATHROOMS <br />LAUNDRY AND UTILITY <br />ROOMS MUST BE HIGH EFFICACY <br />LIGHTING AND HAVE OCCUPANCY SENSORS <br />NEW EXHAUST FAN <br />WITH A MINIMUM CAPACITY <br />OF 50 CFM DUCT LESS FAN <br />ARE UNACCEPTABLE <br />CARBON MONOXIDE REQUIREMENTS: <br />CMA <br />BATHTUB AND SHOWER FLOORS, <br />WALLS ABOVE BATHTUBS WITH <br />A SHOWER HEAD, AND SHOWER <br />COMPARTMENTS SHALL BE FINISH <br />WITH A NONABSORBENT SURFACE <br />EXTENDING TO A HEIGHT OF NOT <br />LESS THAN 6' FEET ABOVE THE FLOOR <br />THE BUILDING SHALL HAVE <br />WATER CLOSETS (TOILETS) <br />WITCH USE NO MORE THAN <br />1.28 GALLONS PER FLUSH. <br />TAMPER RESISTANT RECEPTACLES <br />IN ALL AREAS SPECIFIED IN SECTION 210.52, ALL <br />125-VOL6, 15-AND 20- AMPERE <br />RECEPTACLES SHALL BE LISTED <br />TAMPER-RESISTANT RECEPTACLES. <br />CARBON MONOXIDE ALARMS SHALL RECEIVE <br />THEIR PRIMARY POWER FROM BUILDING WIRING <br />SHALL BE EQUIP WITH BATTERY BACK UP <br />AND INTERCONNECTED <br />FAN <br />LIGHT <br />ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, <br />CLOTHES WASHER DRYER, BUILT-IN HEATERS, OR ANY <br />OTHER FIXED APPLIANCE WITH 1/4 H.P. MOTOR OR <br />LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE <br />BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE <br />INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT <br />SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP <br />INDICATING-TYPE SWITCH <br />EXHAUST VENTS: <br />LOCAL VENTILATION EXHAUST IS REQUIRED IN EACH <br />BATHROOM, LAUNDRY/UTILITY ROOM AND KITCHENS IN <br />THE FOLLOWING CAPACITIES, 50 CFM IN BATHROOMS, <br />100 CFM IN KITCHENS, AND 50 CFM IN <br />LAUNDRY/UTILITY ROOMS. EXHAUST VENTS SHALL <br />BE SEPARATELY SWITCHED FROM THE LIGHTING. <br />MINIMUM SLOPE ON SEWER LINE <br />AND DRAINAGE PIPING IS 2% <br />ALL HOSE BIBS MUST BE PROTECTED <br />BY AN ANTI-SIPHON DEVICE <br />SYM.FRAMESIZE <br />SLD <br />WIxHI GLAZING HEAD HT. MIN.TYPE <br />B 4'-0"X3'-0'' <br />WINDOWS SCHEDULE <br />TYPE <br />C 6'-8'' <br />3'-0''X2'-0'' <br />SLIDE6'-8'' <br />1 <br />SYM. <br />DOOR SCHEDULE <br />GLASS <br />1 3/8" <br />SIZE THK. <br />S.C. <br />FACE FRAME REMARKSCONST. <br />3'-0" X 6'-8" <br />3 1 3/8"WOOD <br />EXTERIOR (SOLID) OR 20 MINUTE DOORMETALTEMPERED <br />ON FRONT DOOR <br />2'-6" X 6'-8"WOOD <br />A VINYL <br />DUAL GAZED <br />5'-0"X4'-0'' <br />SLD <br />SLD <br />6'-8''SLIDE <br />SLIDE <br />INTERIOR21 3/8"WOODWOOD2'-8" X 6'-8" <br />METAL <br />ELECTRIC PLAN <br />EXISTING / DEMO. <br />VS <br />DUAL GAZED <br />DUAL GAZED <br />DUAL GAZED <br />LAUNDRY DOOR SHALL HAVE LOWERED MAKE UP AIR <br />MIN 12'' SQ INCHES TOP AND 12'' SQ INCHES BOTTOM <br />OUTDOOR LIGHTING ATTACHED TO <br />BUILDINGS MUST BE CONTROLLED <br />BY A MOTION SENSOR WITH PHOTO CONTROL <br />OUTDOOR LIGHTING ATTACHED TO <br />BUILDINGS MUST BE CONTROLLED <br />BY A MOTION SENSOR WITH PHOTO CONTROL <br />DRYER EXHAUST DUCT SHALL TERMINATE NO LESS <br />THAN 3'-0'' FROM OPENINGS INTO THE BUILDING <br />THE BUILDING SHALL HAVE <br />WATER CLOSETS (TOILETS) <br />WITCH USE NO MORE THAN <br />1.28 GALLONS PER FLUSH. <br />AUTOMATIC GARAGE DOOR OPENER INSTALLED IN A <br />RESIDENCE MUST HAVE AN AUTOMATIC REVERSE SAFETY <br />DEVICE AND A BATTERY BACKUP FUNCTION THAT IS <br />DESIGNED TO OPERATE WHEN ACTIVATED BECAUSE OF <br />AN ELECTRICAL OUTAGE. <br />ATTIC SPACE WITH AN OPENING OF 22”X30” AND NO FIXED STAIRS, HOWEVER A PULL-DOWN <br />ACCESS STAIR IS ALLOWED, AND ELECTRICAL IS NOT REQUIRED. 2) THE FLOOR IS DESIGNED FOR A <br />LIGHT STORAGE LOAD OF 125 PSF AND FLOOR AREA IS TAKEN INTO ACCOUNT OF LATERAL DESIGN, <br />STAIRS ARE ALLOWED, ONLY ONE LIGHT, NO RECEPTACLES 3) THE ROOM ABOVE IS LISTED AS A <br />HABITABLE SPACE, SUCH AS A RECREATION ROOM OR WHATEVER THE PLANNING DEPARTMENT <br />WILL APPROVE, 1 HOUR FIRE SEPARATION FROM THE GARAGE BELOW, AND ELECTRICAL PLAN AND <br />PERMANENT HEATING SYSTEM. THIS AREA IS LIMITED TO 1/50TH OF THE PARCEL SIZE, NO <br />COOKING FACILITY, AND CANNOT BE USED AS A RENTAL UNIT. <br />4'' ROUND DUCT TO ROOF <br />DUPLEX OUTLET AFCI <br />THE ELECTRICAL TO COMPLY WITH THE 2022 CALIFORNIA ENERGY <br />CODE AND 2022 CEC. <br />ALL NEW LIGHTS MUST BE HIGH EFFICACY AND CONTROLLED BY A DIMMER OR <br />VACANCY SENSOR. <br />EXTERIOR LIGHTING MUST BE HIGH EFFICACY AND CONTROLLED BY A MOTION SENSOR <br />AND PHOTOCONTROL. <br />MOTION CENSOR <br />W / PHOTO CONTROL <br />THE 2022 CALIFORNIA ENERGY CODE INCLUDES THE FOLLOWING ELECTRIC READY MANDATORY <br />REQUIREMENTS. PLEASE PROVIDE THE FOLLOWING NOTES ON THE PLANS AS THE APPLICABLE <br />INFRASTRUCTURE MUST BE INSTALLED: (CENC 150.0) <br />I. IF A GAS OR PROPANE WATER HEATING SYSTEM, PROVIDE DESIGNATED SPACE <br />FOR FUTURE HEAT PUMP WATER HEATER AT LEAST 2.5 FEET BY <br />2.5 FEET AND 7 FEET TALL. <br />A. IF WITHIN 3 FEET OF WATER HEATER PROVIDE A 125V, 20 A CIRCUIT WITH <br />120/240V CONDUCTOR. RESERVE AND LABEL SINGLE <br />POLE BREAKER IN MAIN PANEL. <br />B. IF MORE THAN 3 FEET FROM WATER HEATER PROVIDE 240V, 30A CIRCUIT <br />FLOOR PLAN <br />SCALE 1/4'' = 1' <br />4 <br />B <br />A <br />4 <br />W/D <br />22x30 <br />ATTIC <br />ACCESS <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />D <br />O <br />O <br />R <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />R <br />E <br />M <br />O <br />V <br />E <br />D <br />EXISTING <br />CONCRETE DRIVEWAY <br />MINI SPLIT AC <br />WATER PROOF <br />MOISTER PROOF <br />NEW ELECTRIC <br />PANEL 200 AMP <br />110 VOLTS & 220 VOLTS <br />100 CFM <br />FAN FOR <br />KITCHEN <br />HOOD <br />EXISTING / DEMOLITION PLAN <br />1/8'' = 12'' <br />EXISTING <br />DOOR TO <br />REMAIN <br />EXISTING GAR. <br />DOOR 16' FT. <br />TO BE REMOVED <br />& FILL <br />EXISTING 2x4 EXTERIOR WALLS <br />EXISTING 2 CAR <br />GARAGE <br />SETBACKS, MIN. 3' SIDE SETBACKS AN ENCLOSURE <br />MUST BE PROVIDED AS IT MAY NOT BE VISIBLE FROM <br />NEIGHBORING PROPERTIES OR PUBLIC RIGHT-OF-WAY. <br />1/4'' = 1' <br />SIGNATURE: <br />CHECKED BY: <br />DATE: <br />SCALE: <br />JOB NO. <br />SHEET TITLE: <br />SHEET NO. <br />100 <br />REVISIONS <br />PER CRC SECTION R308, SAFETY GLAZING (TEMPERED <br />GLASS) IS REQUIRED FOR WINDOWS THAT ARE BOTH WITHIN 24” <br />OF DOORS AND WITHIN 60” OF THE WALKING SURFACE. ALSO <br />SPECIFY SAFETY GLAZING FOR DOORS AND WINDOWS WITHIN <br />ANY PORTION OF WALL ENCLOSING TUBS/SHOWERS, HOT TUBS, <br />WHIRLPOOLS, SAUNAS, AND STEAM ROOMS WHERE THE <br />BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60” <br />ABOVE A STANDING SURFACE AND DRAIN INLET. <br />ALL BATHROOM FANS: <br />THIS FAN IS TO BE USED FOR LOCAL <br />VENTILATION EXHAUST. MINIMUM 50 <br />CFM FAN TESTED AT A STATIC PRESSURE <br />OF .25 WC AND RATED @ 3 SONES <br />OR LESS REQUIRED TO BE INSTALLED. <br />FAN MUST BE ATTACHED TO A <br />MINIMUM 4” DUCT AND NO LONGER <br />THAN 70’ OF FLEX DUCT. SUBTRACT 15’ OF <br />ALLOWED LENGTH FOR EACH ELBOW. <br />ALL KITCHEN RANGE HOODS: <br />THIS FAN IS TO BE USED FOR LOCAL <br />VENTILATION EXHAUST. MINIMUM 280 <br />CFM FAN TESTED AT A STATIC <br />PRESSURE OF .25 WC AND RATED <br />@ 3 SONES OR LESS REQUIRED TO <br />BE INSTALLED. FAN MUST BE ATTACHED TO A <br />MINIMUM 5” SMOOTH DUCT AND <br />NO LONGER THAN 85’. SUBTRACT 15’ OF <br />ALLOWED LENGTH FOR EACH ELBOW. <br />NOTE ON PLANS: “ALL NEW <br />DOMESTIC HOT WATER PIPING SHALL BE <br />INSULATED PER CPC2022 SECTION 609.11.” <br />WHEN TWO OR MORE BUILDINGS ARE ON THE SAME <br />PROPERTY LINE AND THEY ARE NOT ANALYZED TO <br />COMPLY AS ONE BUILDING, THE BUILDING SHALL <br />HAVE A AN ASSUME PROPERTY LINE BETWEEN <br />THEM FOR DETERMINING WALL AND OPENING <br />PROTECTION, AND ROOF COVER REQUIREMENTS OR <br />TREATED AS A SINGLE BUILDING PER CBC 705.3. <br />ALTERNATIVELY PROVIDE FIRE RATING WALL FOR THE <br />NEW STRUCTURE. (SEE FIRE WALL ON PAGE 4) <br />ALL POWER AND LIGHTING OUTLETS IN DWELLING <br />UNIT KITCHENS, FAMILY ROOMS, DINING <br />ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, <br />DENS, BEDROOMS, SUNROOMS, RECREATION <br />ROOMS, CLOSETS, HALLWAYS, LAUNDRY <br />AREAS, OR SIMILAR AREAS ARE TO BE <br />PROTECTED BY A “LISTED AFCI BREAKER” <br />OR OTHER MEANS AS DESCRIBED IN CEC 210.12(A). <br />BATHROOMS, AND BASEMENTS ARE <br />EXEMPT FROM THIS REQUIREMENT. [CEC 210.12(A)] <br />INDIVIDUAL DEDICATED CIRCUITS ARE <br />REQUIRED FOR ALL MAJOR APPLIANCES. THE RATING OF <br />AN INDIVIDUAL BRANCH CIRCUIT SHALL <br />NOT BE LESS THAN THE MARKED RATING OF THE <br />APPLIANCES OR THE MARKED RATING <br />OF THE APPLIANCES HAVING COMBINED LOADS AS <br />PROVIDED IN 422.62. [CEC 210.11(C) & 422.10(A)] <br />DEDICATED 20-AMP CIRCUIT FOR BATHROOM, 20-AMP <br />CIRCUIT FOR LAUNDRY ROOM AND A <br />MINIMUM OF (2) 20-AMP CIRCUIT FOR SMALL APPLIANCES <br />AT KITCHEN. <br />250 CFM FOR <br />GAS RANGE <br />AND 160 CFM <br />FOR ELECTRIC <br />RANGE <br />21'-0" <br />17'-0" <br />EXISTING <br />BEDROOM # 4EXISTING <br />BEDROOM # 3 <br />EXISTING MASTER <br />BEDROOM # 1 <br />W/D (E) CLOSET <br />(E) CLOSET(E) CLOSET <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />EXISTING <br />KITCHEN <br />EXISTING <br />LIVING ROOM EXISTING <br />RECREATION <br />ROOM <br />EXISTING <br />BEDROOM # 2 <br />EXISTING <br />BATH. # 2 <br />EXISTING <br />M. BATH. # 1 <br />CM <br />CM <br />CM <br />CM <br />CM <br />CM <br />SD <br />SD SD <br />SD <br />SD <br />SD <br />SD <br />CM <br />SD <br />CM <br />CM <br />SD <br />CM <br />SD <br />C <br />WH <br />6'-0" <br />6'-0"4'-8" <br />2'-4" <br />4'-0"4'-0"6'-8"3'-4" <br />2'-0" <br />R <br />8'-6"4'-0"4'-0" <br />12'-0"9'-0" <br />9'-6" <br />5'-6" <br />12'-0"9'-0" <br />EXISTING <br />BEDROOM # 4EXISTING <br />BEDROOM # 3 <br />EXISTING MASTER <br />BEDROOM # 1 <br />W/D (E) CLOSET <br />(E) CLOSET(E) CLOSET <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />EXISTING <br />KITCHEN <br />EXISTING <br />LIVING ROOM EXISTING <br />RECREATION <br />ROOM <br />EXISTING <br />BEDROOM # 2 <br />EXISTING <br />BATH. # 2 <br />EXISTING <br />M. BATH. # 1 <br />WH <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI AFCI <br />AFCI <br />GFCIGFCIGFCIGFCI <br />GFCI <br />GFCI / WP <br />(N) CLOSET <br />(N) BEDROOM -A <br />(N) KITCHEN -A <br />(N) LIVING ROOM <br />22x30 <br />ATTIC <br />ACCESS <br />MOTION CENSOR <br />W / PHOTO CONTROL <br />VS <br />4 <br />DS <br />8'-0'' CLG. <br />8'-4'' CLG.8'-0'' CLG. <br />8'-0'' CLG. <br />(N) BATH. A <br />D <br />E <br />SLD 6'-0"X4'-0''6'-8''SLIDEDUAL GAZED <br />(E) 2 WINDOWS <br />2'-6'' X 4'-0'' <br />REPLACED BY 1 <br />6'-0'' X 4'-0'' <br />(SAME SIZE) <br />1 <br />2 <br />3 <br />(E) 2 WINDOWS <br />2'-6'' X 4'-0'' <br />REPLACED BY 1 <br />6'-0'' X 4'-0'' <br />TANK LESS <br />WATER HEATER <br />AFCI <br />GFCI <br />GFCI / WP <br />WALLS MAY NEED TO BE OPENED UP TO EXPOSE <br />CONSTRUCTION SUBJECT TO FIELD INSPECTOR’S REQUEST. <br />SMOKE DETECTORS ARE REQUIRED <br />TO BE INTERCONNECTED SUCH <br />THAT ACTIVATION OF ONE ALARM <br />WILL RESULT IN THE ACTIVATION OF <br />ALL ALARMS WITHIN THE DWELLING <br />SMOKE AND CARBON MONOXIDE <br />DETECTORS ARE REQUIRED TO BE <br />HARD WIRED WITH BATTERY BACKUP <br />(CRC R314.6 AND R315.6). <br />30'' R. <br />1'-4"1'-4" <br />2'-6" <br />3'-0" <br />MIN. 36'' SQ. <br />CONCRETE <br />LANDING W/ <br />MAX. 1 1/2'' STEP <br />DS <br />GFCI / WP <br />BATHROOM FAN IS REQUIRED TO BE CONTROLLED <br />BY A SEPARATE SWITCH FROM THE LIGHT. <br />LOCATION OF THE 26 CFM INDOOR AIR QUALITY (IAQ) FAN <br />VINYL <br />DUAL GAZEDVINYL <br />DUAL GAZEDVINYL <br />DUAL GAZED <br />TEMPERED <br />6'-8''5'-0"X4'-0''SLD SLIDEDUAL GAZEDVINYL <br />DUAL GAZED <br />E <br />E <br />F SLD 3'-0"X1'-0''6'-8''SLIDEDUAL GAZEDVINYL <br />DUAL GAZED <br />F <br />G SLD 3-0'' X 4'-0''6'-8''SHDUAL GAZEDVINYL <br />DUAL GAZED <br />PROPOSED <br />PROPOSED <br />PROPOSED <br />PROPOSED <br />EXISTING <br />EXISTING <br />EXISTING <br />G <br />EXISTING <br />EXISTING 5 <br />WOOD WOOD TEMPERED DOOR <br />TEMPERED DOORMETALMETAL <br />1 3/8"6'-0'' X 6'-8" F <br />1 3/8"5'-0'' X 6'-8'' SLD / D SLIDE <br />INTERIOR <br />FRENCH EXTERIOR DOOR <br />4 <br />5 <br />PROPOSED <br />PROPOSED <br />PROPOSED <br />H SLD 1'-8" X 5'-0''6'-8''SHDUAL GAZEDVINYL <br />DUAL GAZED <br />H H <br />TEMPERED GLASS <br />G <br />4 <br />PATIO WASH <br />DEMOLISH ALREADY <br />(SEE PICTURE) 153'.0 S.F. <br />AS BUILD <br />9'-0" <br />17'-0" <br />10'-0" <br />PATIO WASH <br />DEMOLISH ALREADY <br />(SEE PICTURE) 80'.0 S. F. <br />SEE SITE PLAN <br />FOR SETBACKS <br />W <br />4