<br />FLOOR PLAN
<br />9
<br />37
<br />PROPOSED NEW 2x4 EXTERIOR WALLS
<br />PROPOSED NEW INTERIOR WALLS
<br />DATA OUTLET
<br />RECESSED DIRECTIONAL
<br />SURFACE MOUNTED
<br />"CASABLANCA" TYPE
<br />RECESSED
<br />WALL MOUNTED
<br />SURFACE MOUNTED
<br />50 CFM RECESSED EXHAUST FAN
<br />ON BATH & LAUNDRY & 250 CFM ON KITCHEN
<br />OR 160 CFM IF ELECTRIC
<br />VENTED TO THE EXTERIOR
<br />CEILING FAN
<br />DUPLEX OUTLET
<br />CEILING MOUNTED
<br />FLUSH FLOOR MOUNTED
<br />DUPLEX OUTLET GFCI
<br />220V OUTLET
<br />TELEPHONE OUTLET
<br />TELEVISION OUTLET
<br />110 VOLT SMOKE DETECTOR
<br />(SEE "GENERAL NOTES"
<br />FOR OTHER SPEC'S)
<br />SPEAKER LOCATION
<br />OUTLET (VERIFY LOC.)
<br />THE LIGHTS SHALL BE
<br />HIGH EFFICACY AND
<br />CONTROLLED BY A
<br />DIMMER/VACANCY
<br />SENSOR/MOTION &
<br />PHOTO CONTROL
<br />(AS APPLICABLE) SEE PLAN
<br />EXTERIOR
<br />LIGHT
<br />CARBON MONOXIDE
<br />ALARMCMA
<br />WHERE MORE THAN ONE SMOKE ALARM
<br />IS REQUIRED TO BE INSTALLED IN SUCH
<br />A MANNER THAT THE ACTIVATION OF ONE
<br />ALARM WILL ACTIVATE ALL OF THE ALARMS.
<br />AT LEAST ONE 20 AMP BRANCH CIRCUIT
<br />SHALL BE PROVIDED TO SUPPLY LAUNDRY
<br />RECEPTACLES OUTLETS. SUCH CIRCUITS
<br />SHALL HAVE NO OTHER OUTLETS
<br />LIGHTING IN BATHROOMS
<br />LAUNDRY AND UTILITY
<br />ROOMS MUST BE HIGH EFFICACY
<br />LIGHTING AND HAVE OCCUPANCY SENSORS
<br />NEW EXHAUST FAN
<br />WITH A MINIMUM CAPACITY
<br />OF 50 CFM DUCT LESS FAN
<br />ARE UNACCEPTABLE
<br />CARBON MONOXIDE REQUIREMENTS:
<br />CMA
<br />BATHTUB AND SHOWER FLOORS,
<br />WALLS ABOVE BATHTUBS WITH
<br />A SHOWER HEAD, AND SHOWER
<br />COMPARTMENTS SHALL BE FINISH
<br />WITH A NONABSORBENT SURFACE
<br />EXTENDING TO A HEIGHT OF NOT
<br />LESS THAN 6' FEET ABOVE THE FLOOR
<br />THE BUILDING SHALL HAVE
<br />WATER CLOSETS (TOILETS)
<br />WITCH USE NO MORE THAN
<br />1.28 GALLONS PER FLUSH.
<br />TAMPER RESISTANT RECEPTACLES
<br />IN ALL AREAS SPECIFIED IN SECTION 210.52, ALL
<br />125-VOL6, 15-AND 20- AMPERE
<br />RECEPTACLES SHALL BE LISTED
<br />TAMPER-RESISTANT RECEPTACLES.
<br />CARBON MONOXIDE ALARMS SHALL RECEIVE
<br />THEIR PRIMARY POWER FROM BUILDING WIRING
<br />SHALL BE EQUIP WITH BATTERY BACK UP
<br />AND INTERCONNECTED
<br />FAN
<br />LIGHT
<br />ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER,
<br />CLOTHES WASHER DRYER, BUILT-IN HEATERS, OR ANY
<br />OTHER FIXED APPLIANCE WITH 1/4 H.P. MOTOR OR
<br />LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE
<br />BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE
<br />INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT
<br />SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP
<br />INDICATING-TYPE SWITCH
<br />EXHAUST VENTS:
<br />LOCAL VENTILATION EXHAUST IS REQUIRED IN EACH
<br />BATHROOM, LAUNDRY/UTILITY ROOM AND KITCHENS IN
<br />THE FOLLOWING CAPACITIES, 50 CFM IN BATHROOMS,
<br />100 CFM IN KITCHENS, AND 50 CFM IN
<br />LAUNDRY/UTILITY ROOMS. EXHAUST VENTS SHALL
<br />BE SEPARATELY SWITCHED FROM THE LIGHTING.
<br />MINIMUM SLOPE ON SEWER LINE
<br />AND DRAINAGE PIPING IS 2%
<br />ALL HOSE BIBS MUST BE PROTECTED
<br />BY AN ANTI-SIPHON DEVICE
<br />SYM.FRAMESIZE
<br />SLD
<br />WIxHI GLAZING HEAD HT. MIN.TYPE
<br />B 4'-0"X3'-0''
<br />WINDOWS SCHEDULE
<br />TYPE
<br />C 6'-8''
<br />3'-0''X2'-0''
<br />SLIDE6'-8''
<br />1
<br />SYM.
<br />DOOR SCHEDULE
<br />GLASS
<br />1 3/8"
<br />SIZE THK.
<br />S.C.
<br />FACE FRAME REMARKSCONST.
<br />3'-0" X 6'-8"
<br />3 1 3/8"WOOD
<br />EXTERIOR (SOLID) OR 20 MINUTE DOORMETALTEMPERED
<br />ON FRONT DOOR
<br />2'-6" X 6'-8"WOOD
<br />A VINYL
<br />DUAL GAZED
<br />5'-0"X4'-0''
<br />SLD
<br />SLD
<br />6'-8''SLIDE
<br />SLIDE
<br />INTERIOR21 3/8"WOODWOOD2'-8" X 6'-8"
<br />METAL
<br />ELECTRIC PLAN
<br />EXISTING / DEMO.
<br />VS
<br />DUAL GAZED
<br />DUAL GAZED
<br />DUAL GAZED
<br />LAUNDRY DOOR SHALL HAVE LOWERED MAKE UP AIR
<br />MIN 12'' SQ INCHES TOP AND 12'' SQ INCHES BOTTOM
<br />OUTDOOR LIGHTING ATTACHED TO
<br />BUILDINGS MUST BE CONTROLLED
<br />BY A MOTION SENSOR WITH PHOTO CONTROL
<br />OUTDOOR LIGHTING ATTACHED TO
<br />BUILDINGS MUST BE CONTROLLED
<br />BY A MOTION SENSOR WITH PHOTO CONTROL
<br />DRYER EXHAUST DUCT SHALL TERMINATE NO LESS
<br />THAN 3'-0'' FROM OPENINGS INTO THE BUILDING
<br />THE BUILDING SHALL HAVE
<br />WATER CLOSETS (TOILETS)
<br />WITCH USE NO MORE THAN
<br />1.28 GALLONS PER FLUSH.
<br />AUTOMATIC GARAGE DOOR OPENER INSTALLED IN A
<br />RESIDENCE MUST HAVE AN AUTOMATIC REVERSE SAFETY
<br />DEVICE AND A BATTERY BACKUP FUNCTION THAT IS
<br />DESIGNED TO OPERATE WHEN ACTIVATED BECAUSE OF
<br />AN ELECTRICAL OUTAGE.
<br />ATTIC SPACE WITH AN OPENING OF 22”X30” AND NO FIXED STAIRS, HOWEVER A PULL-DOWN
<br />ACCESS STAIR IS ALLOWED, AND ELECTRICAL IS NOT REQUIRED. 2) THE FLOOR IS DESIGNED FOR A
<br />LIGHT STORAGE LOAD OF 125 PSF AND FLOOR AREA IS TAKEN INTO ACCOUNT OF LATERAL DESIGN,
<br />STAIRS ARE ALLOWED, ONLY ONE LIGHT, NO RECEPTACLES 3) THE ROOM ABOVE IS LISTED AS A
<br />HABITABLE SPACE, SUCH AS A RECREATION ROOM OR WHATEVER THE PLANNING DEPARTMENT
<br />WILL APPROVE, 1 HOUR FIRE SEPARATION FROM THE GARAGE BELOW, AND ELECTRICAL PLAN AND
<br />PERMANENT HEATING SYSTEM. THIS AREA IS LIMITED TO 1/50TH OF THE PARCEL SIZE, NO
<br />COOKING FACILITY, AND CANNOT BE USED AS A RENTAL UNIT.
<br />4'' ROUND DUCT TO ROOF
<br />DUPLEX OUTLET AFCI
<br />THE ELECTRICAL TO COMPLY WITH THE 2022 CALIFORNIA ENERGY
<br />CODE AND 2022 CEC.
<br />ALL NEW LIGHTS MUST BE HIGH EFFICACY AND CONTROLLED BY A DIMMER OR
<br />VACANCY SENSOR.
<br />EXTERIOR LIGHTING MUST BE HIGH EFFICACY AND CONTROLLED BY A MOTION SENSOR
<br />AND PHOTOCONTROL.
<br />MOTION CENSOR
<br />W / PHOTO CONTROL
<br />THE 2022 CALIFORNIA ENERGY CODE INCLUDES THE FOLLOWING ELECTRIC READY MANDATORY
<br />REQUIREMENTS. PLEASE PROVIDE THE FOLLOWING NOTES ON THE PLANS AS THE APPLICABLE
<br />INFRASTRUCTURE MUST BE INSTALLED: (CENC 150.0)
<br />I. IF A GAS OR PROPANE WATER HEATING SYSTEM, PROVIDE DESIGNATED SPACE
<br />FOR FUTURE HEAT PUMP WATER HEATER AT LEAST 2.5 FEET BY
<br />2.5 FEET AND 7 FEET TALL.
<br />A. IF WITHIN 3 FEET OF WATER HEATER PROVIDE A 125V, 20 A CIRCUIT WITH
<br />120/240V CONDUCTOR. RESERVE AND LABEL SINGLE
<br />POLE BREAKER IN MAIN PANEL.
<br />B. IF MORE THAN 3 FEET FROM WATER HEATER PROVIDE 240V, 30A CIRCUIT
<br />FLOOR PLAN
<br />SCALE 1/4'' = 1'
<br />4
<br />B
<br />A
<br />4
<br />W/D
<br />22x30
<br />ATTIC
<br />ACCESS
<br />EX
<br />I
<br />S
<br />T
<br />I
<br />N
<br />G
<br />
<br />G
<br />A
<br />R
<br />A
<br />G
<br />E
<br />
<br />D
<br />O
<br />O
<br />R
<br />
<br />T
<br />O
<br />
<br />B
<br />E
<br />
<br />R
<br />E
<br />M
<br />O
<br />V
<br />E
<br />D
<br />EXISTING
<br />CONCRETE DRIVEWAY
<br />MINI SPLIT AC
<br />WATER PROOF
<br />MOISTER PROOF
<br />NEW ELECTRIC
<br />PANEL 200 AMP
<br />110 VOLTS & 220 VOLTS
<br />100 CFM
<br />FAN FOR
<br />KITCHEN
<br />HOOD
<br />EXISTING / DEMOLITION PLAN
<br />1/8'' = 12''
<br />EXISTING
<br />DOOR TO
<br />REMAIN
<br />EXISTING GAR.
<br />DOOR 16' FT.
<br />TO BE REMOVED
<br />& FILL
<br />EXISTING 2x4 EXTERIOR WALLS
<br />EXISTING 2 CAR
<br />GARAGE
<br />SETBACKS, MIN. 3' SIDE SETBACKS AN ENCLOSURE
<br />MUST BE PROVIDED AS IT MAY NOT BE VISIBLE FROM
<br />NEIGHBORING PROPERTIES OR PUBLIC RIGHT-OF-WAY.
<br />1/4'' = 1'
<br />SIGNATURE:
<br />CHECKED BY:
<br />DATE:
<br />SCALE:
<br />JOB NO.
<br />SHEET TITLE:
<br />SHEET NO.
<br />100
<br />REVISIONS
<br />PER CRC SECTION R308, SAFETY GLAZING (TEMPERED
<br />GLASS) IS REQUIRED FOR WINDOWS THAT ARE BOTH WITHIN 24”
<br />OF DOORS AND WITHIN 60” OF THE WALKING SURFACE. ALSO
<br />SPECIFY SAFETY GLAZING FOR DOORS AND WINDOWS WITHIN
<br />ANY PORTION OF WALL ENCLOSING TUBS/SHOWERS, HOT TUBS,
<br />WHIRLPOOLS, SAUNAS, AND STEAM ROOMS WHERE THE
<br />BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60”
<br />ABOVE A STANDING SURFACE AND DRAIN INLET.
<br />ALL BATHROOM FANS:
<br />THIS FAN IS TO BE USED FOR LOCAL
<br />VENTILATION EXHAUST. MINIMUM 50
<br />CFM FAN TESTED AT A STATIC PRESSURE
<br />OF .25 WC AND RATED @ 3 SONES
<br />OR LESS REQUIRED TO BE INSTALLED.
<br />FAN MUST BE ATTACHED TO A
<br />MINIMUM 4” DUCT AND NO LONGER
<br />THAN 70’ OF FLEX DUCT. SUBTRACT 15’ OF
<br />ALLOWED LENGTH FOR EACH ELBOW.
<br />ALL KITCHEN RANGE HOODS:
<br />THIS FAN IS TO BE USED FOR LOCAL
<br />VENTILATION EXHAUST. MINIMUM 280
<br />CFM FAN TESTED AT A STATIC
<br />PRESSURE OF .25 WC AND RATED
<br />@ 3 SONES OR LESS REQUIRED TO
<br />BE INSTALLED. FAN MUST BE ATTACHED TO A
<br />MINIMUM 5” SMOOTH DUCT AND
<br />NO LONGER THAN 85’. SUBTRACT 15’ OF
<br />ALLOWED LENGTH FOR EACH ELBOW.
<br />NOTE ON PLANS: “ALL NEW
<br />DOMESTIC HOT WATER PIPING SHALL BE
<br />INSULATED PER CPC2022 SECTION 609.11.”
<br />WHEN TWO OR MORE BUILDINGS ARE ON THE SAME
<br />PROPERTY LINE AND THEY ARE NOT ANALYZED TO
<br />COMPLY AS ONE BUILDING, THE BUILDING SHALL
<br />HAVE A AN ASSUME PROPERTY LINE BETWEEN
<br />THEM FOR DETERMINING WALL AND OPENING
<br />PROTECTION, AND ROOF COVER REQUIREMENTS OR
<br />TREATED AS A SINGLE BUILDING PER CBC 705.3.
<br />ALTERNATIVELY PROVIDE FIRE RATING WALL FOR THE
<br />NEW STRUCTURE. (SEE FIRE WALL ON PAGE 4)
<br />ALL POWER AND LIGHTING OUTLETS IN DWELLING
<br />UNIT KITCHENS, FAMILY ROOMS, DINING
<br />ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
<br />DENS, BEDROOMS, SUNROOMS, RECREATION
<br />ROOMS, CLOSETS, HALLWAYS, LAUNDRY
<br />AREAS, OR SIMILAR AREAS ARE TO BE
<br />PROTECTED BY A “LISTED AFCI BREAKER”
<br />OR OTHER MEANS AS DESCRIBED IN CEC 210.12(A).
<br />BATHROOMS, AND BASEMENTS ARE
<br />EXEMPT FROM THIS REQUIREMENT. [CEC 210.12(A)]
<br />INDIVIDUAL DEDICATED CIRCUITS ARE
<br />REQUIRED FOR ALL MAJOR APPLIANCES. THE RATING OF
<br />AN INDIVIDUAL BRANCH CIRCUIT SHALL
<br />NOT BE LESS THAN THE MARKED RATING OF THE
<br />APPLIANCES OR THE MARKED RATING
<br />OF THE APPLIANCES HAVING COMBINED LOADS AS
<br />PROVIDED IN 422.62. [CEC 210.11(C) & 422.10(A)]
<br />DEDICATED 20-AMP CIRCUIT FOR BATHROOM, 20-AMP
<br />CIRCUIT FOR LAUNDRY ROOM AND A
<br />MINIMUM OF (2) 20-AMP CIRCUIT FOR SMALL APPLIANCES
<br />AT KITCHEN.
<br />250 CFM FOR
<br />GAS RANGE
<br />AND 160 CFM
<br />FOR ELECTRIC
<br />RANGE
<br />21'-0"
<br />17'-0"
<br />EXISTING
<br />BEDROOM # 4EXISTING
<br />BEDROOM # 3
<br />EXISTING MASTER
<br />BEDROOM # 1
<br />W/D (E) CLOSET
<br />(E) CLOSET(E) CLOSET
<br />(E
<br />)
<br />
<br />C
<br />L
<br />O
<br />S
<br />E
<br />T
<br />EXISTING
<br />KITCHEN
<br />EXISTING
<br />LIVING ROOM EXISTING
<br />RECREATION
<br />ROOM
<br />EXISTING
<br />BEDROOM # 2
<br />EXISTING
<br />BATH. # 2
<br />EXISTING
<br />M. BATH. # 1
<br />CM
<br />CM
<br />CM
<br />CM
<br />CM
<br />CM
<br />SD
<br />SD SD
<br />SD
<br />SD
<br />SD
<br />SD
<br />CM
<br />SD
<br />CM
<br />CM
<br />SD
<br />CM
<br />SD
<br />C
<br />WH
<br />6'-0"
<br />6'-0"4'-8"
<br />2'-4"
<br />4'-0"4'-0"6'-8"3'-4"
<br />2'-0"
<br />R
<br />8'-6"4'-0"4'-0"
<br />12'-0"9'-0"
<br />9'-6"
<br />5'-6"
<br />12'-0"9'-0"
<br />EXISTING
<br />BEDROOM # 4EXISTING
<br />BEDROOM # 3
<br />EXISTING MASTER
<br />BEDROOM # 1
<br />W/D (E) CLOSET
<br />(E) CLOSET(E) CLOSET
<br />(E
<br />)
<br />
<br />C
<br />L
<br />O
<br />S
<br />E
<br />T
<br />EXISTING
<br />KITCHEN
<br />EXISTING
<br />LIVING ROOM EXISTING
<br />RECREATION
<br />ROOM
<br />EXISTING
<br />BEDROOM # 2
<br />EXISTING
<br />BATH. # 2
<br />EXISTING
<br />M. BATH. # 1
<br />WH
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI
<br />AFCI AFCI
<br />AFCI
<br />GFCIGFCIGFCIGFCI
<br />GFCI
<br />GFCI / WP
<br />(N) CLOSET
<br />(N) BEDROOM -A
<br />(N) KITCHEN -A
<br />(N) LIVING ROOM
<br />22x30
<br />ATTIC
<br />ACCESS
<br />MOTION CENSOR
<br />W / PHOTO CONTROL
<br />VS
<br />4
<br />DS
<br />8'-0'' CLG.
<br />8'-4'' CLG.8'-0'' CLG.
<br />8'-0'' CLG.
<br />(N) BATH. A
<br />D
<br />E
<br />SLD 6'-0"X4'-0''6'-8''SLIDEDUAL GAZED
<br />(E) 2 WINDOWS
<br />2'-6'' X 4'-0''
<br />REPLACED BY 1
<br />6'-0'' X 4'-0''
<br />(SAME SIZE)
<br />1
<br />2
<br />3
<br />(E) 2 WINDOWS
<br />2'-6'' X 4'-0''
<br />REPLACED BY 1
<br />6'-0'' X 4'-0''
<br />TANK LESS
<br />WATER HEATER
<br />AFCI
<br />GFCI
<br />GFCI / WP
<br />WALLS MAY NEED TO BE OPENED UP TO EXPOSE
<br />CONSTRUCTION SUBJECT TO FIELD INSPECTOR’S REQUEST.
<br />SMOKE DETECTORS ARE REQUIRED
<br />TO BE INTERCONNECTED SUCH
<br />THAT ACTIVATION OF ONE ALARM
<br />WILL RESULT IN THE ACTIVATION OF
<br />ALL ALARMS WITHIN THE DWELLING
<br />SMOKE AND CARBON MONOXIDE
<br />DETECTORS ARE REQUIRED TO BE
<br />HARD WIRED WITH BATTERY BACKUP
<br />(CRC R314.6 AND R315.6).
<br />30'' R.
<br />1'-4"1'-4"
<br />2'-6"
<br />3'-0"
<br />MIN. 36'' SQ.
<br />CONCRETE
<br />LANDING W/
<br />MAX. 1 1/2'' STEP
<br />DS
<br />GFCI / WP
<br />BATHROOM FAN IS REQUIRED TO BE CONTROLLED
<br />BY A SEPARATE SWITCH FROM THE LIGHT.
<br />LOCATION OF THE 26 CFM INDOOR AIR QUALITY (IAQ) FAN
<br />VINYL
<br />DUAL GAZEDVINYL
<br />DUAL GAZEDVINYL
<br />DUAL GAZED
<br />TEMPERED
<br />6'-8''5'-0"X4'-0''SLD SLIDEDUAL GAZEDVINYL
<br />DUAL GAZED
<br />E
<br />E
<br />F SLD 3'-0"X1'-0''6'-8''SLIDEDUAL GAZEDVINYL
<br />DUAL GAZED
<br />F
<br />G SLD 3-0'' X 4'-0''6'-8''SHDUAL GAZEDVINYL
<br />DUAL GAZED
<br />PROPOSED
<br />PROPOSED
<br />PROPOSED
<br />PROPOSED
<br />EXISTING
<br />EXISTING
<br />EXISTING
<br />G
<br />EXISTING
<br />EXISTING 5
<br />WOOD WOOD TEMPERED DOOR
<br />TEMPERED DOORMETALMETAL
<br />1 3/8"6'-0'' X 6'-8" F
<br />1 3/8"5'-0'' X 6'-8'' SLD / D SLIDE
<br />INTERIOR
<br />FRENCH EXTERIOR DOOR
<br />4
<br />5
<br />PROPOSED
<br />PROPOSED
<br />PROPOSED
<br />H SLD 1'-8" X 5'-0''6'-8''SHDUAL GAZEDVINYL
<br />DUAL GAZED
<br />H H
<br />TEMPERED GLASS
<br />G
<br />4
<br />PATIO WASH
<br />DEMOLISH ALREADY
<br />(SEE PICTURE) 153'.0 S.F.
<br />AS BUILD
<br />9'-0"
<br />17'-0"
<br />10'-0"
<br />PATIO WASH
<br />DEMOLISH ALREADY
<br />(SEE PICTURE) 80'.0 S. F.
<br />SEE SITE PLAN
<br />FOR SETBACKS
<br />W
<br />4
|