Laserfiche WebLink
PAGE <br />REV: A 5/16/2025 <br />MICHAEL HAVNAER <br />2528 OAKMONT AVE, SANTA  <br />ANA, CA, 92706 <br />PROJECT NUMBER: <br />  109R-528HAVN <br />SHEET <br />DESIGNER: <br />CHIPPY PRINCE <br />CUSTOMER RESIDENCE: <br />TEL. (562) 760-8480 <br />APN: 003-050-35 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SCOPE OF WORK GENERAL NOTES <br />VICINITY MAPABBREVIATIONS <br />A AMPERE <br />AC ALTERNATING CURRENT <br />AFC ARC FAULT CIRCUIT INTERUPTER <br />AZIM AZIMUTH <br />COMP COMPOSITION <br />DC DIRECT CURRENT <br />(E)EXISTING <br />ESS ENERGY STORAGE SYSTEM <br />MSP MAIN SERVICE PANEL <br />(N)NEW <br />PRE-FAB PRE-FABRICATED <br />PSF POUNDS PER SQUARE FOOT <br />PV PHOTOVOLTAIC <br />RSD RAPID SHUTDOWN DEVICE <br />TL TRANSFORMERLESS <br />V VOLTS <br />W WATTS <br />SHEET INDEX <br />REV NAME DATE COMMENTS <br />INVERTERS: (2) TESLA: POWERWALL 3 1707000-XX-Y <br />(MCI-2) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE <br />1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh PER  <br />PW3 <br />TOTAL ENERGY CAPACITY (IN kWh): 27kWH <br />ULTRA RAIL, SYSTEM DETAIL, FIXED TILT:  <br />SNR-DC-00335 [FLAT, TILT KIT (ROLLED COMP/ MEMBRANE/  <br />FOAM) 1 LAG OMNIBASE] <br />INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS <br />ENERGY GATEWAY 3 <br />PAGE # DESCRIPTION <br />PV-1.0 COVER SHEET <br />PV-2.0 SITE PLAN <br />PV-3.0 LAYOUT <br />PV-3.1 MOUNTING  DETAIL <br />PV-4.0 ELECTRICAL <br />PV-4.1 ELECTRICAL CONT. <br />PV-4.2 ELECTRICAL CALCS <br />PV-4.3 BACKUP LOAD CALCS <br />PV-4.4 PANEL SCHEDULE <br />PV-5.0 SIGNAGE <br />PV-5.1 SIGNAGE 2  <br />NOTE: CEC 2022: 705.12(B)(3)(3):  THIS EQUIPMENT FED BY  <br />MULTIPLE SOURCES.  TOTAL RATING OF ALL OVERCURRENT  <br />DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE  <br />SHALL NOT EXCEED AMPACITY OF BUSBAR. <br />MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. <br />CEC 2022. <br />CEC 2022. <br />INVERTER. SYSTEM COMPLIES WITH 690.41(A). <br />ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE <br />THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS <br />13.87 AMPS MODULE SHORT CIRCUIT CURRENT. <br />21.67 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)]. <br />VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). <br />THROUGH A WALL OR PARTITION PER 706.15(D). <br />THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). <br />BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) <br />2528 Oakmont Ave  <br />Santa Ana CA USA  <br />92706 <br />REV NAME DATE COMMENTS <br />PV-1.0 <br />COVER SHEET <br />***The scope of the plans is for the installation of the <br />solar photovoltaic system only and the approval is subject <br />to compliance with all applicable city and state codes and <br />regulations regarding construction. The approval of the <br />plans does not constitute any certification of the accuracy, <br />completeness, or building permit status of the existing <br />buildings and structures as shown.*** <br />Elect #20186227 <br />APPROVALS:ELECT - M. <br />Smith