My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2528 N Oakmont Ave - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Oakmont Ave
>
2528 N Oakmont Ave
>
2528 N Oakmont Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:48 AM
Creation date
2/13/2026 5:00:47 AM
Metadata
Fields
Template:
Plan
Permit Number
20186227
Full Address
2528 N Oakmont Ave
Street Number
2528
Street Direction
N
Street Name
Oakmont
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: A 5/16/2025 <br />MICHAEL HAVNAER <br />2528 OAKMONT AVE, SANTA <br />ANA, CA, 92706 <br />PROJECT NUMBER: <br /> 109R-528HAVN <br />SHEET <br />DESIGNER: <br />CHIPPY PRINCE <br />CUSTOMER RESIDENCE: <br />TEL. (562) 760-8480 <br />APN: 003-050-35 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): 2020 NEC 706.15(C), 2022 CEC 706.15(C) <br />120 240 <br />520 VDCMAXIMUM ESS DC VOLTAGE:60 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />ENERGY STORAGE SYSTEM <br />PREMISES WIRING MAY REMAIN <br />ENERGIZED AFTER LOSS OF <br />UTILITY POWER <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 48 AMPS <br /> 240 VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2), <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS: <br /> SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF <br />THE CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC <br />INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF <br />REQUESTED BY THE LOCAL AHJ. <br /> SIGNS AND LABELS SHALL ADEQUATELY WARN OF <br />HAZARDS USING EFFECTIVE WORDS, COLORS AND <br />SYMBOLS. <br /> LABELS SHALL BE PERMANENTLY AFFIXED TO THE <br />EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND <br />WRITTEN. <br /> LABEL SHALL BE OF SUFFICIENT DURABILITY TO <br />WITHSTAND THE ENVIRONMENT INVOLVED. <br /> SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS, UNLESS <br />OTHERWISE SPECIFIED. <br /> DO NOT COVER EXISTING MANUFACTURER LABELS. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />4" <br />3" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC <br />2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: <br />690.31(D)(2) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN <br />SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), <br />CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC <br />2022: 705.12(C) <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES. TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF <br />BUSBAR <br />WARNING! <br />LABEL LOCATION: <br />PV LOAD CENTER (IF APPLICABLE) AND <br />ANY PANEL THAT UTILIZES "THE SUM <br />OF BREAKERS RULE". <br />PER CODE(S): NEC 2020: 705.12 (B)(3)(3), <br />CEC 2022: 705.12 (B)(3)(3) <br />#ESTAMP <br />PV-5.0 <br />SIGNAGE <br />ONLY THIS <br />INVERTER HAS <br />RAPID SHUTDOWN <br />LABEL LOCATION: <br />BACKED UP LOADS PANEL <br />NO ADDITIONAL <br />LOADS TO BE <br />ADDED
The URL can be used to link to this page
Your browser does not support the video tag.