My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2502 W McFadden Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
2502 W McFadden Ave
>
2502 W McFadden Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:51 AM
Creation date
2/13/2026 5:00:51 AM
Metadata
Fields
Template:
Plan
Permit Number
101123291
Full Address
2502 W McFadden Ave
Street Number
2502
Street Direction
W
Street Name
McFadden
Street Suffix
Ave
Document Relationships
101123291 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\McFadden Ave\2502 W McFadden Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />FL40 FL40 <br />D45S <br />FL20 <br />FL20 <br />FL20 <br />FL20 <br />FL20 <br />FL20 <br />FL20 <br />D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S D45S FL80 FL80 FL80 <br />D75 <br />D75 <br />D75 <br />D75 <br />D75 <br />D75 <br />D75 <br />FL80 <br />FL80 <br />FL80 <br />FL80EC1EC1 <br />EC1 <br />EC1 <br />M <br />P <br /> <br />A <br /> <br /> <br /> <br /> <br />A <br /> <br />R <br /> <br />C <br /> <br />H <br /> <br />I <br /> <br />T <br /> <br />E <br /> <br />C <br /> <br />T <br /> <br />S <br /> <br /> <br /> <br /> <br />I <br /> <br />N <br /> <br />C <br /> <br />. <br />3578 30th Street <br />V. 619.236.0595 <br />San Diego, CA 92104 <br />MEMBER <br />www.mpa-architects.com <br />AMERICAN INSTITUTE OF ARCHITECTS <br />F. 619.236.0557 <br />CLIENT <br />PROJECT <br />DATENO. <br />REVISIONS <br />DESCRIPTION <br />AS NOTED <br />c <br />Co <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />2 <br />0 <br />2 <br />5 <br />, <br /> <br />M <br />P <br />A <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />. <br /> <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />DRAWN BY: <br />DATE: <br />JP <br />JR <br />24190 <br />PROJECT NO: <br />CHECKED BY: <br />SHEET TITLE <br />SCALE: <br />SHEET NUMBER: <br />DATABASE: <br />A <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> F <br />O <br />R <br />: <br />1-23-25 <br />24190.DWG <br />CEC BUILDERS <br />cecbuilders1@gmail.com <br />P: 303.842.6645 <br />ROBERT BARILE <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />L <br />A <br />U <br />N <br />D <br />R <br />Y <br />25 <br />0 <br />2 <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br />18723 VIA PRINCESSA, STE 321 <br />SANTA CLARITA, CA 91387 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIA <br />NHOJ <br />R UMSEY <br />C26819 <br />Exp. 3-31-2027 <br />P1.0 <br />WASTE PLAN <br />PLUMBING WASTE PLAN A1/4"=1'-0" <br />PRIVATE "IN LINE" WATER METERING DEVICE <br />HWR HOT WATER RETURN PIPING <br />G FUEL GAS PIPING <br />- RISE IN PIPE <br />- DROP IN PIPE <br />- TEE UP <br />- TEE DOWN <br />- DIRECTION OF FLOW <br />- DIRECTION OF SLOPE DOWN <br />FCO FLOOR CLEAN OUT <br />COTG CLEAN OUT TO GRADE <br />CO CLEAN OUT <br />DSP DRY STANDPIPE PIPING <br />WSP WET STANDPIPE PIPING <br />W WASTE PIPING BEL. F.F. OR GRD. <br />W WASTE PIPING ABV. F.F. OR GRD. <br />V VENT PIPING BEL. F.F. OR GRD. <br />V VENT PIPING ABV. F.F. OR GRD. <br />CW COLD WATER PIPING <br />HW HOT WATER PIPING <br />IW INDIRECT WASTE PIPING <br />GV GATE VALVE <br />CV CHECK VALVE <br />OS&Y OUTSIDE SCREW & YOKE VALVE <br />GC GAS COCK <br />PTV PRESS., TEMP., AND RELIEF VALVE <br />SOV SHUT-OFF VALVE <br />U UNION <br />HB HOSE BIBB <br />BFP BACK FLOW PREVENTION ASS'Y. <br />PRV PRESS. REDUCING VALVE <br />FE FIRE EXTINGUISHER <br />POC POINT OF CONN. <br />VTR VENT THRU ROOF <br />W/H WATER HEATER <br />W/M <br />M <br />W/M <br />P.W.M. <br />IW <br />WSP <br />DSP <br />(UTILITY COMPANY METER)WATER METER <br />TO COMPLETE HIS/HER WORK. <br />PLUMBING SHEET NOTES <br />GOVERNING THIS JURISDICTION. <br />APPLICABLE BUILDING CODES, LOCAL OR OTHERWISE. <br />LOCATIONS/DEPTH AND PROPOSED POINT OF CONNECTIONS. <br />LOSS. USE MIN. 1 INCH INSULATION ON HOT WATER PIPING. <br />SHALL BE PLUMBED AND LEVELED. <br />BUILDING EXCEEDS 70 P.S.I.G. <br />1/8" PER FOOT, AS REQUIRED, WITH THE APPROVAL OF THE ADMINISTRATIVE AUTHORITY. <br />AIR CHAMBERS SHALL BE PROVIDED FOR EACH FIXTURE AT HOT AND COLD WATER CONNECTIONS. <br />ALL PIPING SHALL BE PRESSURE TESTED TO THE APPROVAL OF THE ADMINISTRATIVE <br />HOT WATER PIPING SHALL BE INSULATED WITH FIBERGLASS PIPE INSULATION WITH A VAPOR <br />BARRIER, AS REQUIRED FOR LOCAL WEATHER CONDITIONS TO PREVENT EXCESSIVE ENERGY <br />WALL HUNG FIXTURES SHALL BE SECURELY ATTACHED TO WOOD BLOCKING <br />ALL FIXTURES SHALL BE SECURELY ATTACHED TO SUPPORTING SURFACES AS SPECIFIED AND <br />THE CONTRACTOR SHALL INSTALL A PRESSURE REDUCING STATION WHERE WATER PRESSURE TO <br />SINKS WITH A LEGAL AIR GAP OR APPROVED BACKFLOW PREVENTION DEVICE. <br />ALL EQUIPMENT GIVING OFF WASTE OR CONDENSATE ARE REQUIRED TO DRAIN INTO FLOOR <br />WASTE PIPING SHALL BE PITCHED AT A MINIMUM OF 1/4" PER FOOT WHERE POSSIBLE. <br />PIPING GREATER THAN 4 INCHES IN DIAMETER ONLY, MAY BE PITCHED AT A MINIMUM OF <br />ALL PIPING AND EQUIPMENT SHALL COMPLY WITH THE LATEST IAPMO STANDARDS AND ALL <br />SITE CONDITIONS INCLUDING BUT NOT LIMITED TO METER LOCATIONS, LATERAL <br />IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO VERIFY ALL EXISTING AND PROPOSED <br />ALTERNATE METHODOLOGY AND/OR MATERIALS COMPLY WITH ALL CODES AND ORDINANCES <br />THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS NECESSARY <br />CONFORM TO APPLICABLE CODES. IT IS NOT THE INTENTION OF THE PLAN PREPARER TO <br />THESE DRAWINGS ARE DIAGRAMMATIC AND HAVE BEEN PREPARED TO SUGGEST POSSIBLE SIZE, <br />ROUTES, LOCATION AND TERMINATION OF PLUMBING PIPING AND EQUIPMENT AS REQUIRED TO <br />LIMIT THE METHODOLOGY AND/OR MATERIALS UTILIZED BY THE PLUMBING CONTRACTOR WHEN <br />PRIOR TO PLACING IN SERVICE. <br />WITH APPROVED DIELECTRIC COUPLINGS. <br />SIZE <br />LARGER SIZES <br />EXCEPT WHEN ALLOWABLE BY THE GOVERNING AUTHORITY. <br />LAVATORY FAUCETS IN RESTROOM S SHALL BE THE SELF CLOSING TYPE <br />WATER HEATER / BOILER IS ON THE CALIFORNIA ENERGY COMMISSION (C.E.C.) LIST. PROVIDE <br />EXPANSION TANK OR APPROVED METHOD OF RELEIVING PRESSURE (608.3 C.E.C.) <br />LAVATORY TAILPIPE AND HOT WATER LINES SHALL BE INSULATED OR COVERED PER CBC 11B-606.5 <br />JANITORIAL SINK FAUCETS SHALL BE PROTECTED W/ AN APPROVED BACKFLOW PREVENTION DEVICE. <br />COLD AND HOT WATER PIPING TO FIXTURES SHALL BE THOROUGHLY FLUSHED AND RINSED <br />5 PSI FOR 15 MINUTES WATER PIPING: MIN. WATER PRESSURE 120 PSI FOR 15 MINUTES <br />PROVISIONS FOR EXPANSION SHALL BE INSTALLED WHERE NECESSARY PER THE UNIFORM <br />HOT AND COLD WATER PIPING SHALL BE INSTALLED A MINIMUM OF 12" APART WHERE PIPING <br />ALL ROOF PENETRATIONS SHALL BE FLASHED AND COUNTER FLASHED TO ENSURE A DURABLE <br />CONNECTIONS BETWEEN COPPER OR BRASS PIPING AND FERROUS MATERIALS SHALL BE MADE <br />INSTALLED AND CAPPED IN ATTIC SPACE. INSULATE PER TITLE 24 REQUIREMENTS. <br />WHERE HOT WATER IS NOT PROVIDED TO LAVATORY, HOT WATER SUPPLY LINE SHALL <br />ALL FLOOR MOUNTED SANITARY CLEANOUTS SHALL HAVE SKID RESISTANT COVER PLATES <br />SANITARY AND POTABLE WATER PIPING SHALL NOT BE INSTALLED WITHIN THE SAME TRENCH <br />WATER CLOSET FLUSH CONTROL VALVE SHALL BE IN COMPLIANCE WITH 11B-604.6 CBC <br />ALL FLOOR, WALL OR GROUND CLEANOUTS SHALL BE INSTALLED IN A MANNER THAT PROVIDES <br />SUFFICIENT SPACE FOR SEVILLE AND IS IN COMPLETE COMPLIANCE WITH ALL GOVERNING CODES. <br />ALL PIPING SHALL BE SUPPORTED AT THE MINIMUM INTERVALS SHOWN BELOW: <br />AUTHORITY AND MINIMUM STANDARDS AS FOLLOWS: SANITARY PIPING: MIN. WATER PRESSURE <br />21. <br />SYMBOL <br />PLUMBING LEGEND <br />ABBR. <br />27. <br />26. <br />25. <br />24. <br />23. <br />22. <br />IS PARALLEL. <br />20. <br />19. <br />18. <br />3/4" <br />1" <br />WATERPROOF MEMBRANE. <br />1/2" <br />14. <br />16. <br />17. <br />15. <br />13. <br />12. <br />PLUMBING CODE. <br />5. <br />8. <br />10. <br />11. <br />9. <br />7. <br />6. <br />4. <br />3. <br />2. <br />1. <br />DESCRIPTION <br />8 FEET O/C <br />8 FEET O/C <br />10 FEET O/C <br />6 FEET O/C <br />SUPPORT SPACING <br />INSTALLATION OF SOIL OR DRAIN PIPES IN FOOD HANDLING ESTABLISHMENTS WILL COMPLY28. <br />WITH SECTION 318.0 CPC. <br />BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701.0 AND 903.029. <br />OF THE CALIFORNIA PLUMBING CODE. <br />ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY.30. <br />A WATER HEATER PRESSURE AND TEMPERATURE RELIEF DRAIN THAT TERMINATES OUTSIDE31. <br />THE BUILDING SHELL SHALL COMPLY WITH SECTION 608.5 CPC. <br />PROVIDE EXPANSION TANK OR OTHER APPROVED METHOD OF RELIEVING PRESSURE32. <br />33. <br />FOR NEW WATER HEATER PER SECTION 608.3 CPC. <br />PER CPC 309.5 THE PLUMBING PIPING SYSTEM WILL BE DESIGNED AND INSTALLED IN CONFORMANCE 34. <br />WITH SOUND LIMITATIONS AS REQUIRED IN CBC. <br />PER CPC 906.1, ASB/PVC VENT TERMINATIONS UP THROUGH THE ROOF EXPOSED TO SUNLIGHT ARE 35. <br />REQUIRED TO BE PROTECTED BY WATER BASED SYNTHETIC LATEX PAINTS <br />PUBLIC LAVATORIES ARE REQUIRED TO BE SELF CLOSING OR SELF METERING CPC 407.436. <br />ALL EXISTING PLUMBING WASTE AND VENT LINES ARE EXISTING <br />TO REMAIN. THEY ARE SHOWN FOR REFERENCE ONLY AND <br />NEED TO BE FIELD VERIFIED. EXISTING WASHING MACHINES <br />ARE BEING REPLACED WITH NEW IN EXISTING LOCATIONS. <br />WASTE PLAN NOTE: <br />MAX FLOW RATE SET BY CALIF. GREEN CODE (5.303.2.2): WATER CLOSETS 1.28 GA/FLUSH, LAVATORY <br />FAUCETS 0.5 GA/FLUSH, LAUNDRY SINK FAUCETS 0.5 GA/FLUSH. <br />15 <br />' <br />3" VTR <br />LINT SCREEN <br />15 <br />' <br />3" VTR <br />LINT SCREEN <br />(E) 4" WASTE <br />72 FIXTURE <br />UNITS 4" WASTE <br />(E) 6" WASTE <br />P.O.C <br />(N <br />) <br /> <br />6 <br />" <br /> <br />W <br />A <br />S <br />T <br />E <br />236 FIXTURE <br />UNITS 4" WASTE <br />72 FIXTURE <br />UNITS 4" WASTE <br />24 FIXTURE <br />UNITS 4" WASTE <br />15 <br />' <br />3" VTR <br />15 <br />' <br />C <br />P1 <br />3" VTR <br />42 FIXTURE <br />UNITS 4" WASTE <br />VERIFY LOCATION VERIFY LOCATION <br />(E) 4" WASTE <br />EXISTING RESTROOM <br />B <br />P4.0 <br />3" W <br />P&T VALVE TO <br />INDIVIDUALLY <br />DISCHARGE TO <br />MOP SINK <br />(E <br />) <br /> <br />4 <br />" <br /> <br />W <br />A <br />S <br />T <br />E <br />VE <br />R <br />I <br />F <br />Y <br /> <br />L <br />O <br />C <br />A <br />T <br />I <br />O <br />N <br />-7 FRONT LOAD WASHER, 20 POUND <br />SPEED QUEEN SC20 <br />INSTALLED ON 6" METAL BASE <br />SEE DETAIL E/A8 FOR CONNECTION TO SLAB 2"4"2"6FL20 - <br />-24 FRONT LOAD WASHER, 40 POUND <br />SPEED QUEEN SC40 <br />INSTALLED ON 6" METAL BASE <br />SEE DETAIL E/A8 FOR CONNECTION TO SLAB 3"4"2"6FL40 - <br />-7 FRONT LOAD WASHER, 80 POUND <br />SPEED QUEEN SC80 SEE DETAIL H/A8 FOR CONNECTION TO SLAB 3"4"2"6FL80 - <br />TRAP <br />MINIMUM SIZE <br />VENTWASTE EACH <br />FU's REMARKSFU's <br />TOTAL <br />WASTE <br />SYMBOL NUMBER <br />OF UNITS SPECIFICATIONS REMARKS <br />EQUIPMENT DESCRIPTION <br />-2"4"2"3.0 - <br />-INT 4"2"4.0 - <br />-1-1/2"2"2"1.0 - <br />1 24" ECONOMY FLOOR MOP SINK W/ <br />COMMERCIAL GRADE, WALL MTD. FAUCET <br /># 829-001 (WWW.CENTRALRESTAURANT.COM) <br />OR EQUAL ( SEE DETAILS H/P5 & I/P5)MS1 <br />1WC1 <br />1LAV1 <br />AMERICAN STANDARD PRESSURE <br />ASSISTED TOILET <br />AMERICAN STANDARD WALL HUNG LAV <br />LUCERNE 0356421, WHITE <br />PROVIDE ZURN CONCEALED ARM <br />CARRIER OR EQUAL <br />CADET FLOWISE 2467136 <br />TOILET SEAT 5905.100 <br />VERIFY LOCATION <br />21 FIXTURE <br />UNITS 4" WASTE <br />(N) 4" WASTE <br />(E <br />) <br /> <br />W <br />MS1 <br />A <br />P4 <br />C <br />P4 <br />C <br />P1 <br />C <br />P1 <br />C <br />P1 <br />OVERFLOW TO ROOF DRAINOVERFLOW TO ROOF DRAINOV <br />E <br />R <br />F <br />L <br />O <br />W <br /> <br />T <br />O <br /> <br />R <br />O <br />O <br />F <br /> <br />D <br />R <br />A <br />I <br />N <br />OV <br />E <br />R <br />F <br />L <br />O <br />W <br /> <br />T <br />O <br /> <br />R <br />O <br />O <br />F <br /> <br />D <br />R <br />A <br />I <br />N <br />EXISTING ROOF DRAIN <br />PLUMBING CORRECTIONS 6-9-251 <br />1
The URL can be used to link to this page
Your browser does not support the video tag.