Laserfiche WebLink
M <br />P <br /> <br />A <br /> <br /> <br /> <br /> <br />A <br /> <br />R <br /> <br />C <br /> <br />H <br /> <br />I <br /> <br />T <br /> <br />E <br /> <br />C <br /> <br />T <br /> <br />S <br /> <br /> <br /> <br /> <br />I <br /> <br />N <br /> <br />C <br /> <br />. <br />3578 30th Street <br />V. 619.236.0595 <br />San Diego, CA 92104 <br />MEMBER <br />www.mpa-architects.com <br />AMERICAN INSTITUTE OF ARCHITECTS <br />F. 619.236.0557 <br />CLIENT <br />PROJECT <br />DATENO. <br />REVISIONS <br />DESCRIPTION <br />AS NOTED <br />c <br />Co <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />2 <br />0 <br />2 <br />5 <br />, <br /> <br />M <br />P <br />A <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />. <br /> <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />DRAWN BY: <br />DATE: <br />JP <br />JR <br />24190 <br />PROJECT NO: <br />CHECKED BY: <br />SHEET TITLE <br />SCALE: <br />SHEET NUMBER: <br />DATABASE: <br />A <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> F <br />O <br />R <br />: <br />1-23-25 <br />24190.DWG <br />CEC BUILDERS <br />cecbuilders1@gmail.com <br />P: 303.842.6645 <br />ROBERT BARILE <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />L <br />A <br />U <br />N <br />D <br />R <br />Y <br />25 <br />0 <br />2 <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br />18723 VIA PRINCESSA, STE 321 <br />SANTA CLARITA, CA 91387 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIA <br />NHOJ <br />R UMSEY <br />C26819 <br />Exp. 3-31-2025 <br />P4.0 <br />PLUMBING DETAILS <br />FLOOR CLEAN OUT DETAIL <br />LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF <br />PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT <br />RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER <br />ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE <br />THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR <br />OTHER FCO REQUIREMENTS <br />ADJUSTING COLLAR <br />CAST IRON WYE (WYE WITH <br />REDUCING BRANCH IF MAIN <br />SIZE, 4" MAX <br />IS OVER 4" <br />CAST IRON RISER <br />C.I. 1/8 BEND, FULL <br />WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH <br />PROVIDE PLASTIC PLUG IN CAST IRON BODY. CLEAN TO TOP <br />RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). <br />VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, <br />PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP <br />FLOOR SLAB ON GRADE <br />OF EXPOSED FCO AFTER CLEANING. <br />MEMBRANE CLAMP <br />FINISH FLOOR <br />NO SCALE <br />FLOW FLOW <br />ALLOWED BY LOCAL CODE. <br />CONTRACTORS RESPONSIBILITY <br />AGENCIES IF ABS IS TO BE <br />WITH LOCAL GOVERNING <br />TO VERIFY ALLOWABLE USE <br />BID OR USED. <br />IT IS THE PLUMBING <br />THE USE OF ABS PLASTIC <br />PIPE IS ACCEPTABLE IF <br />ALTERNATE <br />PARTITION <br />PROVIDE WCO AT BASE OF ALL RAIN-LEADER DOWNSPOUTS. PROVIDE WCO WHERE <br />CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. <br />SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR <br />CLEANOUT. LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 48 INCHES OF FLOOR. <br />NO SCALE <br />WALL CLEAN OUT DETAIL <br />GAUGE STAINLESS STEEL <br />COVER WITH BEVELED <br />CONCRETE FLOOR SLAB <br />MACHINE SCREW. <br />EDGES AND FLATHEAD <br />PROVIDE A ROUND 18 <br />TAPERED-THREAD WITH <br />IS CONCEALED IN A <br />WHERE CLEANOUT TEE <br />CHASE OR PARTITION, <br />TFE JOINT COMPOUND. <br />SUNK ABS PLASTIC PLUG, <br />WITH SCREWED COUNTER- <br />PROVIDE CLEANOUT TEE <br />FIXTURE SCHEDULE <br />INFORMATION. <br />FOR FURTHER <br />REFER TO PLUMBING <br />PLAN. <br />AS SHOWN <br />ON FLOOR <br />COLUMN OR <br />BA <br />NOTE: <br />INPUT POWER BACK <br />EXTERNAL CHEMICAL SUPPLY <br />SIGNAL TERMINAL STRIP <br />DRAIN OUTLET <br />COLD WATER OUTLET <br />HOT WATER INLET <br />EXTRA INLET VALVE <br />EXTERNAL CHEMICAL <br /> SUPPLY INLET <br />VACCUM BREAKER <br />14 <br />' <br />- <br />2 <br />" <br />N <br /> S <br />GRAVITY DRAINED WASHING MACHINES C <br />THE FOLLOWING SERVICE WATER HEATING SYSTEMS AND EQUIPMENT MAY BE INSTALLED ONLY IF THE MANUFACTURER HAS <br />CERTIFIED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL APPLICABLE EFFICIENCY REQUIREMENTS LISTED IN 113 OF THE <br />ENERGY EFFICIENCY STANDARDS <br />UNFIRED SERVICE WATER HEATER STORAGE TANKS AND BACKUP TANKS FOR SOLAR WATER HEATING SYSTEMS SHALL HAVE <br />EITHER: EXTERNAL INSULATION WITH AN INSTALLED R- VALUE OF AT LEAST R-12 INTERNAL AND EXTERNAL INSULATION WITH <br />A COMBINED R- VALUE OF AT LEAST R-16 OR SUFFICIENT INSULATION SO THAT THE HEAT LOSS OF THE TANK SURFACE <br />BASED ON AN 80 F WATER-AIR TEMPERATURE DIFFERENCE SHALL BE LESS THAN 6.5 BTU/HR/SF. <br />IF A CIRCULATING HOT WATER SYSTEM IS INSTALLED, IT SHALL HAVE A CONTROL CAPABLE OF AUTOMATICALLY TURNING OFF <br />THE CIRCULATING PUMP(S) WHEN HOT WATER IS NOT REQUIRED. <br />a. OUTLET DEVICES THAT LIMIT THE FLOW OF WATER TO A MAXIMUM OF 2.2 GALLONS PER MINUTE. <br />FOOT ACTUATED CONTROL VALVES, AND OUTLET DEVICES THAT LIMIT THE FLOW OF WATER TO A MAXIMUM OF 2.2 GALLONS <br />PER MINUTE. <br />PROXIMITY SENSOR ACTUATED CONTROL VALVES, AND OUTLET DEVICES THAT LIMIT THE FLOW OF HOT WATER TO A <br />MAXIMUM OF 2.2 GALLONS PER MINUTE. <br />SELF-CLOSING VALVES, AND OUTLET DEVICES THAT LIMIT THE FLOW OF WATER TO A MAXIMUM OF 2.2 GALLONS PER MINUTE, <br />AND 0.25 GALLONS/CYCLE (CIRCULATING HOT WATER SYSTEM). <br />SELF-CLOSING VALVES, AND OUTLET DEVICES THAT LIMIT THE FLOW OF HOT WATER TO A MAXIMUM OF 2.2 GALLONS PER <br />MINUTE, AND 0.25 GALLONS/CYCLE (NON-CIRCULATING HOT WATERSYSTEM). <br />SELF-CLOSING VALVES, AND OUTLET DEVICES THAT LIMIT THE FLOW OF WATER TO A MAXIMUM OF 2.2 GALLONS PER MINUTE, <br />AND 0.25 GALLONS/CYCLE (FOOT SWITCHES AND PROXIMITY SENSOR CONTROLS). <br />LAVATORIES IN RESTROOMS OF PUBLIC FACILITIES SHALL BE EQUIPPED WITH CONTROLS TO LIMIT THE OUTLET <br />TEMPERATURE TO 110 F. INSTALLATION OF THERMO STATIC MIXING VALVES IN PUBLIC USE SINKS REQUIRED <br /> PLUMBING CONTRACTOR SHALL VERIFY LOCATION OF GAS METERS WITH SERVING UTILITY COMPANY <br />(SERVICE WATER HEATING SYSTEMS) <br /> GAS PIPE ABOVE GRADE OUTSIDE BUILDING - SCHEDULE 40 GALVANIZED STEEL PIPE AND FITTINGS <br /> GAS PIPE ABOVE GROUND INSIDE BLDG. - SCHEDULE 40 BLACK STEEP PIPE WITH M.I. FITTINGS <br />14. <br />15. <br />16. <br />18. <br />17. <br />19. <br />20. <br />21. <br />23. <br />25. <br />24. <br />27. <br />26. <br />22. <br />THESE DRAWINGS ARE DIAGRAMMATIC AND HAVE BEEN PREPARED TO SUGGEST POSSIBLE SIZE, ROUTES, <br />LOCATION AND TERMINATION OF PLUMBING PIPING AND EQUIPMENT AS REQUIRED TO CONFORM TO <br />APPLICABLE CODES. IT IS NOT THE INTENTION OF THE PLAN PREPARER TO LIMIT THE METHODOLOGY AND/OR <br />MATERIALS UTILIZED BY THE PLUMBING CONTRACTOR WHEN ALTERNATE METHODOLOGY AND/OR MATERIALS <br />COMPLY WITH ALL CODES AND ORDINANCES GOVERNING THIS JURISDICTION. <br />IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO VERIFY ALL EXISTING AND PROPOSED SITE CONDITIONS <br />INCLUDING BUT NOT LIMITED TO METER LOCATIONS, LATERAL LOCATIONS/DEPTH AND PROPOSED POINT OF <br />CONNECTIONS. <br />ALL PIPING AND EQUIPMENT SHALL COMPLY WITH THE LATEST IAPMO STANDARDS AND ALL APPLICABLE <br />BUILDING CODES, LOCAL OR OTHERWISE. <br />WASTE PIPING SHALL BE PITCHED AT A MINIMUM OF 1/4" PER FOOT WHERE POSSIBLE. PIPING GREATER THAN 4 <br />INCHES IN DIAMETER ONLY, MAY BE PITCHED AT A MINIMUM OF 1/8" PER FOOT, AS REQUIRED, WITH THE <br />APPROVAL OF THE ADMINISTRATIVE AUTHORITY. <br />ALL EQUIPMENT GIVING OFF WASTE OR CONDENSATE ARE REQUIRED TO DRAIN INTO FLOOR SINKS WITH A <br />LEGAL AIR GAP OR APPROVED BACKFLOW PREVENTION DEVICE. <br />THE CONTRACTOR SHALL INSTALL A PRESSURE REDUCING STATION WHERE WATER PRESSURE TO BUILDING <br />EXCEEDS 80 P.S.I. <br />ALL FIXTURES SHALL BE SECURELY ATTACHED TO SUPPORTING SURFACES AS SPECIFIED AND SHALL BE <br />PLUMBED AND LEVELED. <br />HOT WATER PIPING SHALL BE INSULATED WITH FIBERGLASS PIPE INSULATION WITH A VAPOR BARRIER, AS <br />REQUIRED FOR LOCAL WEATHER CONDITIONS TO PREVENT EXCESSIVE ENERGY LOSS. USE MIN. 1 INCH <br />INSULATION ON HOT WATER PIPING. <br />ALL PIPING SHALL BE PRESSURE TESTED TO THE APPROVAL OF THE ADMINISTRATIVE AUTHORITY AND MINIMUM <br />STANDARDS AS FOLLOWS: SANITARY PIPING: MIN. WATER PRESSURE 5 PSI FOR 15 MINUTES WATER PIPING: <br />MIN. WATER PRESSURE 120 PSI FOR 15 MINUTES <br />COLD AND HOT WATER PIPING TO FIXTURES SHALL BE THOROUGHLY FLUSHED AND RINSED PRIOR TO PLACING <br />IN SERVICE. <br />AIR CHAMBERS SHALL BE PROVIDED FOR EACH FIXTURE AT HOT AND COLD WATER CONNECTIONS. <br />WALL HUNG FIXTURES SHALL BE SECURELY ATTACHED TO WOOD BLOCKING <br />13. <br />10. <br />11. <br />12. <br />7. <br />8. <br />9. <br />4. <br />5. <br />6. <br />3. <br />THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS NECESSARY TO <br />COMPLETE HIS/HER WORK. <br />PLUMBING SHEET NOTES <br />1. <br />2. <br /> OIL-FIRED NON-STORAGE TYPES GREATER THAN 210,000 BTU/HR <br />HOT AND COLD WATER PIPING SHALL BE INSTALLED A MINIMUM OF 12" APART WHERE PIPING IS PARALLEL. <br />ALL FLOOR, WALL OR GROUND CLEANOUTS SHALL BE INSTALLED IN A MANNER THAT PROVIDES SUFFICIENT <br />SPACE FOR SEVILLE AND IS IN COMPLETE COMPLIANCE WITH ALL GOVERNING CODES. <br />ALL HOSE BIBS SHALL BE EQUIPPED WITH AN APPROVED NON-REMOVABLE VACUUM BREAKER AND MOUNTED <br />18 INCHES ABOVE THE FINISHED FLOOR LEVEL. ALL BIBBS SHALL BE FLUSH MOUNTED W/ LOCKABLE COVERS. <br />SANITARY AND POTABLE WATER PIPING SHALL NOT BE INSTALLED WITHIN THE SAME TRENCH EXCEPT WHEN <br />ALLOWABLE BY THE GOVERNING AUTHORITY. <br />WATER HEATER / BOILER IS ON THE CALIFORNIA ENERGY COMMISSION (C.E.C.) LIST. PROVIDE EXPANSION <br />TANK OR APPROVED METHOD OF RELEIVING PRESSURE (608.3 C.E.C.) <br />ALL ROOF PENETRATIONS SHALL BE FLASHED AND COUNTER FLASHED TO ENSURE A DURABLE <br />WATERPROOF MEMBRANE. <br />PLUMBING CONTRACTOR SHALL REVIEW ALL KITCHEN EQUIPMENT DRAWINGS AND MAKE ALL REQUIRED <br />CONNECTION OF SERVICES TO EACH UNIT. <br />WHERE HOT WATER IS NOT PROVIDED TO LAVATORY, HOT WATER SUPPLY LINE SHALL INSTALLED AND <br />CAPPED IN ATTIC SPACE. INSULATE PER TITLE 24 REQUIREMENTS. <br />LAVATORY FAUCETS IN RESTROOM S SHALL BE THE SELF CLOSING TYPE <br />ALL PIPING SHALL BE SUPPORTED AT THE MINIMUM INTERVALS SHOWN BELOW: <br />ALL FLOOR MOUNTED SANITARY CLEANOUTS SHALL HAVE SKID RESISTANT COVER PLATES <br />LARGER SIZES <br />1" <br />1/2" <br />3/4" <br />SIZE SUPPORT SPACING <br />8 FEET O/C <br />8 FEET O/C <br />6 FEET O/C <br />10 FEET O/C <br />g. <br /> GAS-FIRED NON-STORAGE TYPES GREATER THAN 200,000 BTU/HR. <br />LAVATORIES IN RESTROOMS OF PUBLIC FACILITIES SHALL BE EQUIPPED WITH: <br />f. <br />e. <br />c. <br />d. <br />b. <br />4. <br />3. <br />2. <br />., <br />PROVISIONS FOR EXPANSION SHALL BE INSTALLED WHERE NECESSARY PER THE UNIFORM PLUMBING CODE. <br />CONNECTIONS BETWEEN COPPER OR BRASS PIPING AND FERROUS MATERIALS SHALL BE MADE WITH <br />APPROVED DIELECTRIC COUPLINGS. <br />JANITORIAL SINK FAUCETS SHALL BE PROTECTED W/ AN APPROVED BACKFLOW PREVENTION DEVICE. <br /> OIL-FIRED STORAGE TYPES GREATER THAN 105,000 BTU/HR <br /> VALVES: ROCKWELL-NORDSTROM LUBRICATED PLUG COCKS. <br />MANDATORY MEASURES <br />1. <br />4. <br />2. <br />3. <br />1. <br />GAS PIPING SCHEDULE <br /> WHERE APPROVED BY CODE, ABS PLASTIC PIPING, WRAPPED PER CODE WHERE PENETRATING CONCRETE. WHERE ABS IS <br />NOT APPROVED BY CODE THEN SERVICE WEIGHT CAST IRON PIPE AND FITTINGS SHALL BE USED. <br /> CLEANOUTS TO GRADE - CLEANOUT PLUG IN BROOKS PRODUCTS CONC. BOX WITH CAST IRON HINGED TOP - LABEL <br />"C.O." <br />OUTSIDE BUILDING BELOW GRADE, WHERE APPROVED BY LOCAL GOVERNING AGENCY, SCHEDULE 40 40 PVC PIPE <br />AND FITTINGS. <br />INSIDE BUILDING AND OUTSIDE BUILDING ABOVE GRADE - TYPE "L" COPPER TUBE WITH RECESSED SHOULDER <br />FITTINGS. WHERE APPROVED BY GOVERNING AGENCY, TYPE 'M' MAY BE USED. <br />WHERE APPROVED BY LOCAL AUTHORITIES, ABS OR PVC PLASTIC. SPILL TO AN APPROVED POINT OF DISCHARGE <br />ALL HOT WATER MAINS, EXCEPT RUN-OUTS TO FIXTURES, BUT INCLUDING HOT WATER SUPPLY AND TRAP AT <br />HANDICAPPED LAVATORIES, SHALL BE INSULATED WITH 3/4" THICK, SNAP ON FIBERGLASS INSULATION WITH CANVAS <br />JACKET, 4.5 MINIMUM <br />VALVES - NIBCO - SCOTT, N.R.S., SWEAT JOINT VALVES. IN LINES BELOW GRADE INSTALL IN BROOKS PRODUCTS <br />CONCRETE BOX WITH CAST IRON HINGED TOP - LABEL 'S.O.V.' <br />IN MULTIPLE TENANT BUILDINGS, WHEN SEPARATE WATER METERS ARE NOT PROVIDED FOR EA. TENANT, EACH LEASE <br />SPACE SHALL BE PROVIDED WITH A "PRIVATE" METERING DEVICE CAPABLE OF MONITORING THE WATER CONSUMPTION <br />OF EACH TENANT. THE PLUMBING CONTRACTOR SHALL INCLUDE IN HIS PROPOSAL THE COST OF ALL LABOR & MATERIAL <br />NECESSARY TO PROVIDE & INSTALL THIS EQUIPMENT <br />THE LOCAL GOVERNING AUTHORITY, THE ACCEPTABILITY <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY WITH <br />PLUMBING MATERIAL SCHEDULE <br /> FLOOR CLEANOUTS - J. R. SMITH - NON-SKID P. N. B. TOP. <br />OF PLASTIC PIPE AS SPECIFIED ABOVE. <br />THE AIRGAP-DRAINAGE SHALL BE NOT LESS THAN ONE (1) INCH BETWEEN THE PLUMBING FIXTURE, APPLIANCE, AR <br />APPURTENANCE OUTLET AND THE RIM OF THE FLOOR SINK OR RECEPTOR AS REQUIRED. <br />6.METERING OF TENANTS WATER USAGE: <br />NOTE: <br />VALVES: <br />ROOF DRAINS <br />INSULATION: <br />ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER SECTION 707.0 AND 709.0 OF THE PLUMBING <br />CODE. <br />EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN TEN (10) FEET FROM OR AT LEAST THREE (3) FEET ABOVE ANY <br />WINDOW, DOOR, OPENING AIR INTAKE OR VENT SHAFT. <br />THE FLOOR SINK SHALL BE PROVIDED WITH A TRAP PRIMER AS REQUIRED SECTION 1007.0. <br />NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE ACCORDING TO THE METHOD SET IN <br />SECTION 609.9 OF THE PLUMBING CODE. <br />5. ALL EXPOSED GAS PIPING SHALL BE KEPT AT LEAST SIX (6) INCHES ABOVE GRADE. <br />PLUMBING NOTES <br />4. <br />3. <br />2. <br />1. <br />WATER PIPE: <br />B. <br />A. <br />CLEANOUTS: <br />A. <br />B. <br />SOIL, WASTE AND VENT PIPING: <br />PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR <br />THE PARTITION, PROVIDE A TRAP AND WASTE LINE TWO PIPE SIZES LARGER THAN THE <br />DRAIN/SINK OUTLET, WITH A REDUCER ON THE TRAP INLET, AND VENT WITHIN 15 FEET. <br />IF FLOOR DRAIN/SINK IS MORE THAN 5' ON A 2" WASTE OR 6' ON A 3" WASTE FROM <br />OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE. <br />CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. <br />PER CPC 309.5 THE PLUMBING PIPE SYSTEM WILL BE DESIGNED AND INSTALLED IN CONFORMANCE WITH SOUND <br />LIMITATIONS AS REQUIRED IN CBC <br />7. <br />PER CPC 906.1 ABS/PVC VENT TERMINATIONS UP THROUGH THE ROOF EXPOSED TO SUNLIGHT ARE REQUIRED TO BE <br />PROTECTED BY WATER BASED SYNTHETIC LATEX PAINTS <br />8. <br />PUBLIC LAVATORIES ARE REQUIRED TO BE SELF-CLOSING OR SELF METERING.9. <br />METERING LAVATORY FAUCETS CAN DELIVER A MAX OF 0.2 GALLONS PER CYCLE. PLEASE SPECIFY THIS WITH THE FIXTURE <br />SCHEDULE. CPC 407.2.4 <br />10. <br />MEMBRANE CLAMP- <br />ING COLLAR AND <br />SEEPAGE PAN <br />SLOPE WASTE AT 2% <br />LENGTH IS 2 FEET <br />MAXIUMUM TAILPIECE <br />PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR <br />THE PARTITION, PROVIDE A TRAP AND WASTE LINE TWO PIPE SIZES LARGER THAN THE <br />DRAIN/SINK OUTLET, WITH A REDUCER ON THE TRAP INLET, AND VENT WITHIN 15 FEET. <br />IF FLOOR DRAIN/SINK IS MORE THAN 5' ON A 2" WASTE OR 6' ON A 3" WASTE FROM <br />OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE. <br />LOCATE FLOOR DRAIN/SINK WHERE SHOWN ON DIMENSIONED ARCHITECTURAL PLAN. <br />IF FLOOR STRUCTURE INTERFERES WITH FLOOR SINK, MOVE SIDEWAYS IF POSSIBLE, <br />OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN <br />FOOT TRAFFIC. IF SITUATION IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER <br />SPECIFICATIONS. IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND <br />POUR AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL <br />IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF FLOOR <br />SINKS 1/2" BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT. DO NOT RECESS <br />CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. <br />WASTE AND VENT AUTHORITY. OTHERWISE <br />TOP OF FLOOR DRAINS. <br />NO SCALE <br />SYSTEM <br />FLOOR DRAIN/SINK <br />OTHERWISE DEEP-SEAL <br />P-TRAP <br />REDUCING TRAP <br />MAX. 15' WHERE <br />A COMBINATION <br />LINE IS USED AS <br />ENLARGED WASTE <br />CONCRETE FLOOR <br />PROVIDE TRAP PRIMER <br />IF REQ'D BY LOCAL WASTE LINE <br />OR 6' ON 3" <br />MAX 5' ON 2" <br />D <br />PROVIDE <br />1/2" <br />TRAP PRIMER <br />TROUGH DRAIN E