Laserfiche WebLink
M <br />P <br /> <br />A <br /> <br /> <br /> <br /> <br />A <br /> <br />R <br /> <br />C <br /> <br />H <br /> <br />I <br /> <br />T <br /> <br />E <br /> <br />C <br /> <br />T <br /> <br />S <br /> <br /> <br /> <br /> <br />I <br /> <br />N <br /> <br />C <br /> <br />. <br />3578 30th Street <br />V. 619.236.0595 <br />San Diego, CA 92104 <br />MEMBER <br />www.mpa-architects.com <br />AMERICAN INSTITUTE OF ARCHITECTS <br />F. 619.236.0557 <br />CLIENT <br />PROJECT <br />DATENO. <br />REVISIONS <br />DESCRIPTION <br />AS NOTED <br />c <br />Co <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />2 <br />0 <br />2 <br />5 <br />, <br /> <br />M <br />P <br />A <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />. <br /> <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />DRAWN BY: <br />DATE: <br />JP <br />JR <br />24190 <br />PROJECT NO: <br />CHECKED BY: <br />SHEET TITLE <br />SCALE: <br />SHEET NUMBER: <br />DATABASE: <br />A <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> F <br />O <br />R <br />: <br />1-23-25 <br />24190.DWG <br />CEC BUILDERS <br />cecbuilders1@gmail.com <br />P: 303.842.6645 <br />ROBERT BARILE <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />L <br />A <br />U <br />N <br />D <br />R <br />Y <br />25 <br />0 <br />2 <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br />18723 VIA PRINCESSA, STE 321 <br />SANTA CLARITA, CA 91387 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIA <br />NHOJ <br />R UMSEY <br />C26819 <br />Exp. 3-31-2025 <br />R1.0 <br />REFERENCE SHEET <br /> 1. GENERAL: <br />PAINTING <br /> ONE COAT ENAMEL. <br /> ARCHITECTURAL DRAWINGS: <br /> OTHERWISE NOTED. <br /> DRAWINGS. <br /> A. PAINT AND STAIN AS SPECIFIED ON THE FINISH SCHEDULE AND NOTED <br /> OF CONTIGUOUS MATERIAL, UNLESS OTHERWISE NOTED ON THE <br /> B. PAINT ALL FLASHING VISIBLE FROM PUBLIC AREAS TO MATCH COLOR <br /> GRADE DOORS) OR CLEAN WOOD STAIN AS NOTED PLUS TWO <br /> (e) INTERIOR DOORS: TWO COATS SEMIGLOSS ENAMEL (PAINT <br /> SEMIGLOSS ENAMEL SHALL BE APPLIED TO WALLS AND CEILING. <br /> LATEX EXCEPT TOILET ROOMS WHEN TWO COATS WASHABLE <br /> (d) INTERIOR GYPSUM WALL BOARD: TWO COATS WASHABLE FLAT <br /> PURSUANT TO MANUFACTURER'S SPECIFICATIONS UNLESS <br /> (c) EXTERIOR AND INTERIOR WOOD: OLYMPIC STAIN APPLIED <br /> ONE COAT ENAMEL APPLIED AT JOB AFTER INSTALLATION. <br /> (b) INTERIOR METAL: ONE COAT PRIMER APPLIED AT SHOP, PLUS <br /> ONE COAT PRIMER APPLIED AT JOB AFTER INSTALLATION AND <br /> (a) EXTERIOR METAL: ONE COAT PRIMER APPLIED AT SHOP, PLUS <br /> APPLIED AS FOLLOWS UNLESS OTHERWISE SPECIFIED ON THE <br /> ON THE DRAWINGS SHALL BE OF A NON-LEAD BASE AND SHALL BE <br /> COATS OF VELVET LACQUER (STAIN GRADE DOORS). <br /> 7. CONDUIT: <br /> ROOF. <br /> FASTENERS. <br /> 9. RECEPTACLES: <br /> 8. OUTLET BOXES: <br /> SCREWS. <br /> 5242-IV. <br /> TYPE. <br /> CONSTRUCTION. <br /> DRAWINGS. <br />D. <br />AND PAY FEES NECESSARY FOR THE COMPLETION OF HIS WORK. <br />THE PLUMBING CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS <br /> FIXTURES AND DRAINS SHOWN INCLUDING STUB OUTS FOR FIXTURES <br /> E. PROVIDE AND CONNECT DOMESTIC WATER AND WASTE LINES TO ALL <br /> REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK <br /> EQUIPMENT, AND ACCESSORIES NOT SPECIFICALLY IDENTIFIED, BUT <br /> C. THE PLUMBING CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, <br /> INFORMATION IS FOR REFERENCE ONLY AND MUST BE VERIFIED. <br /> METERS, AND SIMILAR ELEMENTS SHOWN ON THE DRAWINGS. THIS <br /> MAIN/LATERALS, WATER MAINS/LATERALS, WATER METERS, GAS <br /> LOCATION AND EXISTENCE OF ANY SEWER MAINS/LATERALS, GAS <br /> B. IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO VERIFY <br /> THESE NOTES FOR MORE SPECIFIC INFORMATION REGARDING THESE <br /> LOCAL GOVERNING AGENCIES. SEE A.D.A./TITLE 24 SECTION OF <br /> THE UNIFORM PLUMING CODE, TITLE 24, A.D.A., AND ALL OTHER <br /> A. PLUMBING: ALL PLUMBING SHALL COMPLY WITH THE REQUIREMENTS OF <br /> FURNISHED BY OTHERS INCLUDING, BUT NOT LIMITED TO HVAC <br /> F. PROVIDE AND CONNECT GAS LINES AND SERVICE TO EQUIPMENT TO BE <br /> SHOWN DOTTED ON THE DRAWINGS. <br /> AS INDICATED ON THE DRAWINGS. <br /> EQUIPMENT. <br /> 1. GENERAL REQUIREMENTS: <br /> REQUIREMENTS. <br />PLUMBING <br /> BE IVORY IN COLOR. <br /> LIGHTS AND WARNING SIGNS, ETC. AS REQUIRED TO PROTECT THE PUBLIC, <br /> EMPLOYEES ABOUT THE BUILDING SITE, PROPERTY AND EQUIPMENT DURING <br /> ETC., SHALL BE IN ACCORDANCE WITH ACCEPTABLE STANDARD PRACTICE <br /> TYPEWRITTEN DIRECTORY ON ALL SWITCHBOARD, PANELBOARDS, AND LOAD <br /> CENTER. ELECTRICAL EQUIPMENT SHALL BE PROVIDED WITH THE MINIMUM <br /> INTERRUPTED RATING CAPACITY AS INDICATED ON THE ELECTRICAL <br />11. PROVIDE AND MAINTAIN ALL SUITABLE BARRIERS, PROTECTIVE DEVICES, <br />12. ALL INSTALLATION OF CONDUIT, CONDUCTORS, PANELBOARDS, BOXES, <br />13. PROVIDE AS INDICATED ON THE ELECTRICAL DRAWINGS A COMPLETE <br /> AND GOVERNING CODES, COORDINATE ALL WORK WITH OTHER TRADES. <br /> AND RATINGS INDICATED ON THE ELECTRICAL PLANS. <br /> B. MAIN SWITCHBOARDS AND PANELS SHALL BE EQUAL TO THE <br /> C. BRANCH PANELS SHALL BE THE ENCLOSED THERMAL MAGNETIC CIRCUIT <br /> D. ALL PANELBOARDS USED IN PROJECT SHALL BE FROM THE SAME <br /> A. RIGID CONDUIT SHALL BE HOT-DIP GALVANIZED, GENERAL ELECTRIC <br /> WHITE ZINC-COATED OR SHERADIZED. RIGID CONDUIT SHALL BE USED <br /> UNDERGROUND OR WHERE SUBJECT TO MECHANICAL INJURY. <br /> B. ELECTRICAL METALLIC TUBING (E.M.T.) MAY BE USED IN ALL DRY <br /> AREAS SUCH AS STUD PARTITIONS AND FURRED CEILING SPACES AND <br /> C. ALUMINUM CONDUIT MAY BE USED AT INSIDE PROTECTED LOCATIONS IN <br /> E. NOT USED <br /> F. CONTROL WIRE TO AIR-CONDITIONING UNITS SHALL BE PLASTIC <br /> JACKET 18-4 (4 WIRE) AND SHALL BE IN CONDUIT FROM THE <br /> THERMOSTATIC CONTROL BOX TO THE AIR-CONDITIONING UNIT ON THE <br /> A. ALL SPLICES, TAPS AND TERMINALS SHALL BE MADE IN JUNCTION <br /> B. AT ALL CURRENT CONSUMING OR SWITCHING OUTLETS PROVIDE AN <br /> APPROVED OUTLET BOX OF NOT LESS THAN 14 GAUGE STEEL AND OF <br /> C. ALL BOXES AND OUTLETS INTENDED FOR FIXTURES SHALL HAVE <br /> APPROVED FIXTURE STUDS FASTENED TO THE BOXES WITH APPROVED <br /> A. DUPLEX RECEPTACLES SHALL BE THE SPECIFICATIONS GRADE, <br /> 15-AMPERE, 125 VOLT, 3-WIRE SIDE-WIRED TYPE, WITH BINDING <br /> SCREWS, PARALLEL SLOTS, U-GROUND AND CAPTIVE MOUNTING <br /> A. WALL SWITCHES SHALL BE THE SPECIFICATION GRADE, QUIET TOGGLE <br /> B. SWITCHES SHALL BE 125 VOLT, 15-AMP., OR AS REQUIRED, IVORY <br /> C. ALL RECEPTACLES, SWITCHES, TELEPHONE OUTLETS AND OTHER <br /> MISCELLANEOUS OUTLETS IN FINISHED AREAS SHALL BE COVERED WITH <br /> WALL PLATES BEARING THE U.L. LISTED MARK, BE 0.100" THICK AND <br /> MANUFACTURED BY THE "SQUARE-D" COMPANY, CROUSE HINDS, R.S.E., <br /> OR EQUAL. <br /> SIZE 2" OR LARGER NONMETALLIC CONDUIT MAY BE USED UNDERGROUND <br /> G. UNDERGROUND SERVICE CONDUIT ON THE OWNER'S PROPERTY SHALL BE <br /> BOXES OR PULL BOXES AND BE PROVIDED WITH A SUITABLE COVER OF <br /> THE SAME FINISH AS THE RACEWAY. GANG BOXES SHALL BE SIZED AS <br /> B. ALL RECEPTACLES SHALL HAVE IVORY COLOR OR EQUAL TO ARROWHART <br /> APPROVED BY LOCAL BUILDING OR UTILITY AUTHORITIES. <br /> THE SAME MATERIAL AS THE BOX. <br /> REQUIRED FOR BANKS OF MORE THAN ONE SWITCH. <br /> 5250-I, G.E. 4052-2, HUBBEL 5242, SIERRA 1402 OR SLATER <br /> COLOR AND EQUAL TO THE BRYANT 4900-1 SERIES. <br />10. SWITCHES AND WALL PLATES: <br /> MANUFACTURER. <br /> WHERE PERMITTED BY CODE. <br /> WITH A NONTAMPERABLE SINGLE-HANDLE COMMON TRIP. <br /> BY CONTINUOUS FROM OUTLET TO PANELBOARD. <br /> D. USE AVA OR THHN IN FLUORESCENT LUMINARIES. <br /> A. THE PANEL BOARDS SHALL BE THE ENCLOSED TYPE WITH THE VOLTAGE <br /> 6. SERVICE EQUIPMENT: <br /> ROOF UNITS. <br /> MARKS THE ROOF SHEATHING FOR THE POINT OF PENETRATION. <br /> LINES IN AIR DUCT AREAS UNTIL THE AIR CONDITIONING CONTRACTOR <br /> G. DO NOT INSTALL AIR CONDITIONING GAS PIPING OR CONDENSATE <br /> TO AN EFFECTIVE FLUE OR VENT LEADING TO THE OUTSIDE AIR. SUCH <br /> FLUE OR VENT SHALL NOT BE LESS IN SIZE THAT THE VENT COLLAR <br /> RECOGNIZED TESTING AGENCY FOR UNVENTED USE, SHALL BE CONNECTED <br /> C. EVERY GAS BURNING APPLIANCE UNLESS APPROVED BY A NATIONALLY <br /> LOCAL GOVERNING CODE AND SHALL NOT BE LOCATED UNDER ANY <br /> B. GAS BURNING WATER HEATERS SHALL BE LOCATED AS REQUIRED BY THE <br /> THAT LIMIT THE OUTLET TEMPERATURE TO A MAXIMUM OF 110 DEGREES <br /> FLOW HOT WATER OR HAVE SELF CLOSING FAUCETS OR HAVING DEVICES <br /> LAVATORIES IN PUBLIC FACILITIES HAVING DEVICES THAT LIMIT THE <br /> (EXCLUDING: WATERHEATERS OF THE NONSTORAGE ELECTRIC TYPE AND <br /> MUST BE CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION <br /> A. WATER HEATERS, SHOWERHEADS, LAVATORY FAUCETS AND SINK FAUCETS <br /> SHALL BE ANCHORED OR STRAPPED TO PREVENT HORIZONTAL AND <br /> H. ANCHORAGE OF WATER HEATERS: IF PROVIDED, THE WATER HEATER <br /> BURNERS SHALL BE EQUIPPED WITH INTERMITTENT IGNITION DEVICES. <br /> D. ALL GAS APPLIANCES, EXCEPT WATER HEATERS AND RANGE TOP <br /> STAIRWAY EXCEPT AS PROVIDED IN THE BUILDING CODE. <br /> F.) SECTION 2-5314, TABLE 2-53G (CALIFORNIA ONLY). <br /> 2. GAS BURNING APPLIANCES AND PLUMBING FIXTURES: <br /> VERTICAL DISPLACEMENT DUE TO EARTHQUAKE. <br /> ON THE APPLIANCE. <br />2. <br /> FULLY OPERABLE ELECTRICAL SYSTEM INCLUDING DISTRIBUTION SYSTEMS, <br /> PANELBOARDS, DISCONNECT SWITCHES, LIGHTING FIXTURES, POWER AND <br /> CONTROL WIRING, EMPTY CONDUIT, FINAL CONNECTIONS TO ALL EQUIPMENT <br /> AND MISCELLANEOUS MATERIALS, AND EQUIPMENT REQUIRED FOR A <br /> A. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, <br /> EQUIPMENT, AND ACCESSORIES NOT SPECIFICALLY IDENTIFIED, BUT <br /> CODE. ANSI C1-1971, AND ALL APPLICABLE COUNTY AND CITY CODES <br />AND ORDINANCES <br /> FEES, INSPECTIONS AND TESTS AS REQUIRED BY LOCAL AUTHORITIES. <br /> REQUIRED, AND CONFORM TO N.E.M.A. STANDARDS, N.E.C. (NATIONAL <br /> ELECTRICAL CODE), AND THE A.I.E.E. (AMERICAN INSTITUTE OF <br /> REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK <br /> 1. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AND <br />NOT USED <br /> 3. ALL WORK OF THIS SECTION SHALL CONFORM TO NATIONAL ELECTRICAL <br /> 4. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS, <br /> 5. ALL MATERIALS SHALL BE NEW, U.L. APPROVED, UNLESS OTHERWISE <br /> AS INDICATED ON THE DRAWINGS. <br /> ELECTRICAL ENGINEERS). <br /> COMPLETE AND SEPARATE SYSTEM, AS SPECIFIED ON PLANS. <br />ELECTRICAL <br /> ADDITIONAL INFORMATION APPLICABLE TO THIS SECTION <br /> IMPROPER GROUNDS IN ACCORDANCE WITH THE REQUIREMENTS OF THE <br /> SPECIFICATIONS. ANY DISCREPANCIES BETWEEN ANY OF THE VARIOUS <br /> ELEMENTS OF THE ELECTRICAL DRAWINGS SHALL BE REFERRED TO <br /> A. EACH AREA ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL HAVE <br /> INDEPENDENT CONTROL OF THE LIGHTING WITHIN THAT AREA. <br /> B. EACH AREA ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL HAVE AT <br /> LEAST ONE READILY ACCESSIBLE MANUALLY OPERATED SWITCHING <br /> DEVICE TO CONTROL LIGHTING WITHIN THE AREA. FOR LIGHTING <br /> CONTROLS, "READILY ACCESSIBLE" MEANS LOCATED SO THAT A <br /> PERSON USING THE DEVICE CAN SEE THE CONTROLLED LIGHTS OR THE <br /> AREA BEING LIT. SWITCHING DEVICES IN ADDITION TO, BUT NOT <br /> INSTEAD OF, THE REQUIRED READILY ACCESSIBLE MANUALLY <br /> WHICH THE CONNECTED LIGHTING LOAD EQUALS OR EXCEEDS 1.0 <br /> WATTS PER SQUARE FOOT THROUGHOUT THE ENTIRE AREA SHALL BE <br /> CONTROLLED SO THAT THE LOAD MAY BE REDUCED BY AT LEAST <br /> ONE-HAVE WHILE MAINTAINING A REASONABLY UNIFORM LEVEL OF <br /> ILLUMINATIONS THROUGHOUT THE AREA. READILY ACCESSIBLE <br /> SWITCHES, THAT CONTROL EACH LUMINARE IN A SPACE WITH MORE <br /> THAN ONE LUMINAIRE, OR THAT CONTROL EACH LAMP IN A SPACE <br /> INDEPENDENTLY MEET THE REQUIREMENTS OF THIS SECTION. <br /> D. IN ALL AREAS WHERE EFFECTIVE USE MAY BE MADE OF NATURAL <br /> LIGHT, LIGHTING CIRCUITING SHALL BE ARRANGED SO THAT UNITS, <br /> IN ALL PORTIONS OF THE AREA WHERE NATURAL LIGHT IS AVAILABLE <br /> AT THE SAME TIME, ARE SWITCHED INDEPENDENTLY OF THE <br /> A. THE BUILDER SHALL PROVIDE THE BUILDING OWNER, MANAGER, AND <br /> THE ORIGINAL OCCUPANTS A LIST OF THE HEATING, COOLING, WATER <br /> C. THE GENERAL LIGHTING OF ANY AREA 100 SQUARE FEET OR LARGER IN <br />15. PROVIDE AN ELECTRICAL OUTLET AS REQUIRED FOR NEW HEATING AND A.C. <br />16. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY, SHORTS AND <br />17. CONTRACTOR TO GUARANTEE WORK AND MATERIALS FOR PERIOD OF ONE YEAR <br /> HEATING, AND LIGHTING SYSTEMS INSTALLED IN THE BUILDING, <br /> INCLUDING INSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY, THE <br /> INSTRUCTIONS SHALL BE CONSISTENT WITH SPECIFICATIONS SET <br /> B. SEE AMERICANS WITH DISABILITIES ACT/TITLE 24 NOTES FOR <br /> REMAINDER OF THE AREA. <br /> OPERATED SWITCHING DEVICES SHALL BE PERMITTED. <br />20. OCCUPANT OPERATING AND MAINTENANCE INFORMATION: <br /> FORTH BY THE EXECUTIVE DIRECTOR. <br /> N.E.C. (NATIONAL ELECTRICAL CODE). <br /> AFTER FINAL ACCEPTANCE. <br />MPA ARCHITECTURAL GROUP FOR CLARIFICATION. <br />18. SEE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION AND <br />19. CONTROL DEVICES FOR INDOOR LIGHTING PER TITLE 24: (CALIFORNIA ONLY) <br />14. NOT USED <br /> PAINT. <br /> OR BETTER. <br /> 1. SUSPENDED CEILINGS: <br /> F. SEE DOOR SPECIFICATIONS <br /> E. PROVIDE PLYWOOD TELEPHONE BACKBOARD AS REQUIRED. <br /> MORE THAN 1/8" AT ALL EDGES, JAMB AND SILL. <br /> PINE OR WESTERN LARCH, GRADE B OR BETTER. <br /> 2. FINISH CARPENTRY: <br /> LIGHT FIXTURES AND SIMILAR FEATURES. <br /> NOTED OTHERWISE. <br /> THE ARCHITECTURAL DRAWINGS. <br /> ARCHITECTURAL DRAWINGS. <br /> ARCHITECTURAL DRAWINGS. <br /> TREATED DOUGLAS FIR. <br />DRAFTSTOPS/SHAFT ENCLOSURES <br /> 2. FIRESTOPS: <br /> FOR OPENINGS THROUGH ONE-HOUR WALLS. <br /> 4. SHAFT ENCLOSURES: <br /> AT EACH END AND AT THE MIDDLE OF EACH FLIGHT. <br /> FILL ALL SPACES BETWEEN STUDS AND FURRING SHALL BE <br /> 3. ENCLOSED SPACES: <br /> ACROSS THE SPACE TO BE FIRE-STOPPED. <br /> INSPECTION. <br /> WITH SELF CLOSING DEVICES. <br /> LEANDRO, CA OR EQUAL. <br /> 2. MISCELLANEOUS IRON: <br /> FOR REVIEW BY MPA ARCHITECTURAL GROUP FOR GENERAL <br /> SPECIFICALLY DETAILED ON THE DRAWINGS OR NOT. <br /> 1. STRUCTURAL STEEL: <br /> GALVANIZED. <br /> 3. SHOP COAT: <br /> WITH GROUT, MOLTEN SULFER OR MOLTEN LEAD. <br /> 1. ROUGH FRAMING: <br />ROUGH AND FINISH CARPENTRY <br /> A. THE QUALITY AND DESIGN OF WOOD MEMBERS, MATERIALS AND <br /> SHALL BE: <br /> CODES. <br /> 4-16D NAILS EACH SIDE OF THE JOINT. <br /> ORDINANCES AND CODES. <br /> BUILDING CODES. <br /> PURPOSES FOR WHICH THEY ARE USED. <br /> OTHERWISE. <br /> G. ALL LUMBER SHALL BE D.F. LARCH 2 OR BETTER UNLESS NOTED <br /> BONDED WITH EXTERIOR GLUE OR SHALL BE AN EXTERIOR TYPE. <br /> WHETHER, SUCH AS EAVES, SOFFITS OR CANOPY CEILINGS, SHALL BE <br /> PLYWOOD USED IN PROTECTED LOCATIONS INDIRECTLY EXPOSED TO THE <br /> DIRECTLY EXPOSED TO THE WEATHER SHALL BE EXTERIOR TYPE. <br /> OVERLAY OVER THE REQUIRED SUBFLOOR. PLYWOOD USED IN AREAS <br /> AS AN INTERIOR ARCHITECTURAL FINISH MATERIALS OR AS AN <br /> JOISTS, TRUSSES AND BLOCKING UNLESS SUCH PLYWOOD IS USED ONLY <br /> INCLUDING UNDERLAYMENT SHALL BE BONDED WITH EXTERIOR AT ALL <br /> F. ALL CONSTRUCTION PLYWOOD USED ON WALLS, ROOFS AND FLOORS, <br /> TIED BY A MINIMUM 1/8" THICK BY 1-1/2" WIDE STEEL STRAP WITH <br /> E. WHERE PLATES ARE CUT, NOTCHED OR DRILLED, THE PLATE SHALL BE <br /> SPECIFICALLY APPROVED BY THE LOCAL GOVERNING AGENCIES. <br /> TO THE REQUIREMENTS OF THE LOCAL GOVERNING AGENCIES OR <br /> (b) ATTESTED TO BY AN APPROVED TESTING AGENCY AS CONFORMING <br /> HAS BEEN ISSUED PURSUANT TO LOCAL GOVERNING AGENCIES, <br /> (a) MANUFACTURED BY A TYPE I FABRICATOR TO WHOM AN APPROVAL <br /> INCHES, OR USING CONNECTORS OF A TYPE VISIBLE AFTER ASSEMBLY <br /> MEMBERS WITH A TOTAL CROSS-SECTIONAL AREA EXCEEDING 24 SQUARE <br /> D. TIMBER TRUSSES AND SIMILAR STRUCTURAL ASSEMBLIES HAVING <br /> PRACTICES AND TO THE REQUIREMENTS OF OF LOCAL GOVERNING <br /> THEIR FASTENINGS SHALL CONFORM TO ACCEPTED ENGINEERING <br /> C. PREPARATION, FABRICATION AND INSTALLATION OF WOOD MEMBERS AND <br /> TO DEVELOP THE STRENGTH AND RIGIDITY NECESSARY FOR THE <br /> B. ALL MEMBERS SHALL BE FRAMED, ANCHORED TIED, AND BRACED SO AS <br /> THE CONSTRUCTION DOCUMENTS AND THE LOCAL GOVERNING BUILDING <br /> FASTENINGS SHALL CONFORM TO THE PROVISIONS AND STANDARDS OF <br /> 1. CONTRACT: <br />GENERAL INFORMATION <br /> PROPER EXECUTION AND COMPLETION OF THE WORK. <br /> AND ACCEPTS THE SITE "AS IS". <br /> INCORPORATED IN THE CONSTRUCTION. <br /> CONTRACT, AND ALL MODIFICATIONS THERETO. <br /> BEAR ALL COSTS ARISING THEREFROM. <br /> SUCH NOTICE TO MPA ARCHITECTURAL GROUP, HE SHALL <br /> NOTIFY MPA ARCHITECTURAL GROUP IN WRITING. <br /> CONDUCT OF THE WORK AS DRAWN AND SPECIFIED. <br /> DISCREPANCIES PRIOR TO COMMENCING WORK. <br /> JOB & NOTIFY MPA ARCHITECTURAL GROUP OF ANY <br /> 2. GENERAL NOTES: <br /> PERFORMED BY ANY TRADE. <br /> FLUSH WITH REMAINING SURFACES. <br /> GROUP SHALL DETERMINE TO BE JUST. <br /> MPA ARCHITECTURAL GROUP AND SHALL NOT <br /> GROUND AND PROTECTED FROM DAMAGE. <br /> VISITED THE SITE, FAMILIARIZED HIMSELF WITH THE CONDITIONS <br /> CONTAINERS. MATERIALS AND EQUIPMENT SHALL BE STORED OFF THE <br /> SHALL BE DELIVERED TO THE SITE IN THE ORIGINAL MANUFACTURER'S <br /> M. ALL MATERIALS AND EQUIPMENT SHALL BE FREE FROM DEFECTS, AND <br /> SUCH NOTICE PROMPTLY AFTER DISCOVERY OF THE CONDITION. <br /> SURVIVE TERMINATION OF THE CONTRACT. THE OWNER SHALL GIVE <br /> WRITTEN ACCEPTANCE OF SUCH CONDITION. THIS OBLIGATION SHALL <br /> UNLESS THE OWNER HAS PREVIOUSLY GIVEN THE CONTRACTOR A <br /> AFTER RECEIPT OF A WRITTEN NOTICE FROM THE OWNER TO DO SO <br /> DOCUMENTS, THE WITH THE CONTRACTOR SHALL CORRECT IT PROMPTLY <br /> TO BE DEFECTIVE OR NOT IN ACCORDANCE WITH THE CONTRACT <br /> REQUIRED BY THE CONTRACT DOCUMENTS, ANY OF THE WORK IS FOUND <br /> LAW OR BY THE TERMS OF ANY APPLICABLE SPECIAL WARRANTY <br /> WITHIN SUCH LONGER PERIOD OF TIME AS MAY BE PRESCRIBED BY THE <br /> AFTER ACCEPTANCE BY THE OWNER OF DESIGNATED EQUIPMENT OR <br /> OF THE WORK OR DESIGNATED PORTION THEREOF OR WITHIN ONE YEAR <br /> L. IF, WITHIN ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION <br /> OPENINGS, REMOVE WALL PORTION, BURN OFF REINFORCING BARS <br /> PROVIDED IN EXISTING WALLS; SAW CUT AT PERIMETER OF NEW <br /> K. NO JACK HAMMERING ALLOWED WHERE NEW OPENINGS ARE TO BE <br /> CHARGE THE COST TO THE SEVERAL CONTRACTORS AS MPA DESIGN <br /> IN CASE OF DISPUTE THE OWNER MAY REMOVE THE RUBBISH AND <br /> "BROOM CLEAN" OR ITS EQUIVALENT, UNLESS MORE EXACTLY SPECIFIED. <br /> REMOVE ALL HIS SURPLUS MATERIALS AND SHALL LEAVE HIS WORK <br /> EMPLOYEES OR WORK, AND AT THE COMPLETION OF THE WORK HE SHALL <br /> ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS <br /> J. CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM <br /> THE DRAWINGS AND SPECIFICATIONS FOR THE COMPLETED STRUCTURE. <br /> WORK OF OTHER CONTRACTORS SHOWN UPON OR REASONABLY IMPLIED BY <br /> TOGETHER PROPERLY AND FIT IT TO RECEIVE OR BE RECEIVED BY <br /> WORK THAT MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS COME <br /> I. CONTRACTOR SHALL DO ALL CUTTING, FITTING OR PATCHING OF HIS <br /> TO BE LOADED WITH A WEIGHT THAT WILL ENDANGER ITS SAFETY. <br /> CONTRACTOR SHALL NOT LOAD OR PERMIT ANY PART OF THE STRUCTURE <br /> UNREASONABLY ENCUMBER THE PREMISES WITH HIS MATERIALS. <br /> INDICATED BY LAWS, ORDINANCES, PERMITS OR DIRECTIONS OF <br /> MATERIALS, AND THE OPERATIONS OF HIS WORKMEN TO LIMITS <br /> H. CONTRACTOR SHALL CONFINE HIS APPARATUS, THE STORAGE OF <br /> SCAFFOLDING, WINDOW OPENINGS, STAIRWAYS AND FALLING MATERIALS. <br /> AS PROTRUDING NAILS, HOISTS, WELL HOLES, ELEVATOR HATCHWAYS, <br /> CREATED BY BUT NOT LIMITED TO SUCH FEATURES OF CONSTRUCTION <br /> PUBLIC & SHALL POST DANGER SIGNS WARNING AGAINST THE HAZARDS <br /> NECESSARY SAFEGUARDS FOR THE PROTECTION OF WORKMEN & THE <br /> REQUIRED BY THE CONDITIONS AND PROGRESS OF THE WORK, ALL <br /> G. CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES, AS <br /> PROPERTY INJURY OR LOSS ARISING IN CONNECTION WITH HIS WORK. <br /> ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S <br /> F. CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF <br /> TO SUCH LAWS, ORDINANCES, RULES AND REGULATIONS, AND WITHOUT <br /> E. IF THE CONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY <br /> SPECIFICATIONS ARE AT VARIANCE THEREWITH, HE SHALL PROMPTLY <br /> D. IF THE CONTRACTOR OBSERVES THAT THE DRAWINGS AND <br /> LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE <br /> C. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL <br /> COMPLETION OF THE WORK AS INDICATED ON THE DRAWINGS. <br /> IDENTIFIED, BUT REQUIRED FOR THE PROPER EXECUTION AND <br /> MATERIALS, EQUIPMENT, AND ACCESSORIES NOT SPECIFICALLY <br /> B. ALL CONTRACTORS AND SUBCONTRACTORS SHALL PROVIDE ALL LABOR, <br /> A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS ON THE <br /> SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE <br /> CONTROL THE CONTRACTOR IN DIVIDING WORK AMONG THE <br /> SECTIONS AND ARTICLES, THE ARRANGEMENT OF DRAWINGS SHALL NOT <br /> G. THE ORGANIZATION OF THE SPECIFICATIONS AND INTO DIVISIONS, <br /> USED HEREIN IN ACCORDANCE WITH SUCH RECOGNIZED MEANINGS. <br /> F. WORDS WHICH HAVE WELL KNOWN TECHNICAL OR TRADE MEANINGS ARE <br /> INFERABLE AS BEING NECESSARY TO PRODUCE THE INTENDED RESULTS. <br /> ELSEWHERE IN THE CONTRACT DOCUMENTS OR IS REASONABLY <br /> SPECIFICATIONS SHALL BE SUPPLIED UNLESS IT IS REQUIRED <br /> SECTION, BRANCH, CLASS OR TRADE OF GENERAL NOTES OR <br /> E. IT IS NOT INTENDED THAT WORK NOT COVERED UNDER ANY HEADING, <br /> MATERIALS, EQUIPMENT AND OTHER ITEMS AS NECESSARY FOR THE <br /> INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR, <br /> BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. THE <br /> D. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS REQUIRED <br /> OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS <br /> WHICH THE WORK IS TO BE PERFORMED, AND CORRELATED HIS <br /> AND LAWS, CODES AND GOVERNMENTAL AGENCY REGULATIONS UNDER <br /> COMMENCING OF WORK THE CONTRACTOR REPRESENTS THAT HE HAS <br /> C. BY EXECUTING THE CONTRACT OR ENTERING UPON THE SITE AND <br /> LABOR, MATERIALS AND EQUIPMENT INCORPORATED OR TO BE MEANT <br /> CONSTRUCTION REQUIRED BY THE CONTRACT DOCUMENTS, AND ALL <br /> B. THE TERM WORK INCLUDES ALL LABOR NECESSARY TO PRODUCE THE <br /> SPECIFICATIONS, ALL ADDENDA ISSUED PRIOR TO EXECUTION OF THE <br /> A. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE DRAWINGS, <br /> AND STRUCTURAL TUBING (T'S) SHALL CONFORM TO ASTM A-500 GRADE <br /> B. THE FIRE ASSEMBLIES FOR STAIRWAY SHAFTS SHALL BE EQUIPPED <br /> A FIRE ASSEMBLY HAVING A FIRE PROTECTION RATING OF ONE HOUR <br /> A. EVERY OPENING INTO A SHAFT ENCLOSURE SHALL BE PROVIDED WITH <br /> B. ENCLOSED SPACES BETWEEN STAIR STRINGERS SHALL BE FIRE-STOPPED <br /> SHALL BE FIRESTOPPED AROUND THE CONCEALED PERIMETER. <br /> FIRESTOPPED AT THE BASE OF THE COVE. SLIDING DOOR POCKETS <br /> TEN FEET, MEASURED VERTICALLY. TOP AND BOTTOM PLATES WHICH <br /> BETWEEN FIRESTOPS IN WALLS AND PARTITIONS SHALL NOT EXCEED <br /> MIDPOINT IN WALLS MORE THAN TEN FEET HIGH. THE DISTANCE <br /> SHALL BE FIRESTOPPED AT THE TOP AND BOTTOM AND ALSO AT THE <br /> A. ENCLOSED SPACES IN STUD WALLS, PARTITIONS, AND FURRED WALLS <br /> AND ROOF SPACE. FIRESTOPPING SHALL FORM A COMPLETE BLOCK <br /> EFFECTIVE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY <br /> OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN <br /> A. FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT <br /> SELF CLOSING DOORS CONSTRUCTED AS REQUIRED FOR THE PARTITION. <br /> ON CENTER. OPENINGS IN THE PARTITIONS SHALL BE PROTECTED WITH <br /> INCHES NOMINAL THICKNESS MATERIAL SPACED NOT OVER 24 INCHES <br /> SIX PENNY NAILS AT EACH SUPPORT. SUPPORTS SHALL BE TWO <br /> SHALL BE NAILED AT NOT TO EXCEED FOUR INCHES ON CENTER WITH <br /> ONE HOUR FIRE RESISTIVE WHERE REQUIRED. ALL GYPSUM BOARD <br /> HAVE ADOPTED THE UNIFORM BUILDING CODE. PARTITIONS SHALL BE <br /> IN THE COUNTY OF LOS ANGELES AND THOSE JURISDICTIONS WHICH <br /> SQUARE FEET IN THE CITY OF LOS ANGELES AND 3000 SQUARE FEET <br /> AND ROOF ABOVE SHALL BE DIVIDED INTO AREAS NOT EXCEEDING 2500 <br /> A. WHERE SUSPENDED CEILING OCCUR, THE SPACE BETWEEN THE CEILING <br /> D. ALL WOODWORK OR DOORS SHALL BE SANDED SMOOTH AND READY FOR <br /> C. DOORS SHALL BE INSTALLED ACCURATELY WITH A CLEARANCE OF NOT <br /> B. INTERIOR MILLWORK MAY BE NORTHERN OR IDAHO WHITE PINE, SUGAR <br /> DRAWINGS, ALL FINISHED LUMBER SHALL BE DOUGLAS FIR, GRADE B <br /> A. UNLESS OTHERWISE SPECIFIED OR NOTED ON THE ARCHITECTURAL <br /> M. PROVIDE SOLID BACKING FOR ALL PLUMBING FIXTURES, CABINETS, <br /> L. ALL VERTICAL FRAMING SHALL BE "STUD GRADE" OR BETTER UNLESS <br /> AT THE CEILING AND MID-HEIGHT, UNLESS OTHERWISE SPECIFIED ON <br /> K. ALL STUD WALLS SHALL BE FIRE STOPPED WITH 2" THICK MATERIAL <br /> J. NAILS SHALL BE COMMON WIRE UNLESS OTHERWISE NOTED ON THE <br /> I. ALL PLYWOOD SHALL BE PSI 74 UNLESS OTHERWISE NOTED ON THE <br /> LUMBER BY WWPA. SILLS ON CONCRETE WALLS SHALL BE PRESSURE <br /> SHALL CONFORM TO THE 1990 STANDARD GRADING RULES FOR WESTERN <br /> H. ALL TIMBER SHALL BE DOUGLAS FIR UNLESS OTHERWISE NOTED AND <br /> "B" UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS. <br /> C. ALL STRUCTURAL STEEL SHALL BE FABRICATED BY AN ICBO (AS <br /> APPLICABLE) LICENSED SHOP. ALL WELDING SHALL BE DONE BY <br /> WELDERS HOLDING A CURRENT CERTIFICATE. DESIGN FABRICATION AND <br /> ERECTION SHALL BE DONE IN ACCORDANCE WITH THE 1978 AISC <br /> SPECIFICATION. ALL FIELD WELDING SHALL HAVE CONTINUOUS <br /> A. HOLD DOWNS, POST BASES, COLUMN CAPS, JOIST HANGERS, TIE <br /> STRAPS AND SIMILAR STRUCTURAL HARDWARE SHALL BE SIMPSON <br /> STRONG TIE CONNECTORS AS MANUFACTURED BY SIMPSON COMPANY, SAN <br /> B. PIPE RAILINGS, UNLESS OTHERWISE DETAILED ON THE ARCHITECTURAL <br /> DRAWINGS SHALL BE 1-1/2 INCH STANDARD WEIGHT STEEL PIPE <br /> MEETING THE REQUIREMENTS OF ASTM A-120, 32 INCHES HIGH WITH <br /> TWO HORIZONTAL RAILS AND WITH UPRIGHTS SPACED NOT OVER 8 FEET <br /> ON CENTER, FLUSH TYPE FITTINGS SHALL BE USED AND ALL WELDS <br /> SHALL BE GROUND SMOOTH. EXTERIOR PIPE RAILS SHALL BE HOT-DIP <br /> GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A-123 <br /> AND TREATED CHEMICALLY TO PROVIDE A PHOSPHATE PAINT HOLDING <br /> FILM. PIPE RAILS SHALL BE FASTENED TO MASONRY BY FLANGES AND <br /> EXPANSION BOLTS AND TO CONCRETE IN 4 INCH SLEEVES AND CAULKED <br /> A. ALL FERROUS METAL SHALL BE GIVEN ONE SHOP COAT OF RED LEAD <br /> OIL PAINT UNLESS SPECIFIED OR NOTED ON THE ARCHITECTURAL <br /> DRAWINGS. ALL FERROUS METALS TO BE BUILT INTO MASONRY OR <br /> CONCRETE SHALL BE COVERED WITH ASPHALT PAINT OR SHALL BE <br />METAL FRAMING PRODUCTS, STRUCTURAL STEEL <br /> A. PRIOR TO FABRICATION, CONTRACTOR SHALL PREPARE SHOP DRAWINGS <br /> DESIGN CONSIDERATION ONLY. THE FABRICATOR ASSUMES ALL <br /> RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS. BEARING PLATES, <br /> STIFFENERS, GUSSETS, ANGLES AND OTHER SIMILAR STEEL ITEMS <br /> SHALL BE PROVIDED AS REQUIRED FOR THE WORK WHETHER <br /> B. STRUCTURAL STEEL SHALL CONFORM TO ASTM A-36; PIPE COLUMNS <br /> SHALL CONFORM TO ASTM A-501 AND ASTM A-53 (TYPE "E" OR "S") <br /> A. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 40, AND <br /> B. REINFORCING DETAILING AND PLACING SHALL BE IN ACCORDANCE WITH <br /> THE CONCRETE reinforcing STEEL INSTITUTE "MANUAL OF STANDARD <br /> C. ALL REINFORCING STEEL SHALL BE FREE OF LOOSE FLAKY RUST, <br /> MUD, OIL AND OTHER COATINGS THAT WILL REDUCE THE BOND BETWEEN <br /> D. UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL REINFORCING STEEL <br /> E. ALL REINFORCING SHALL BE PLACED IN ACCORDANCE WITH THE <br /> DRAWINGS AND, UNLESS OTHERWISE NOTED THE FOLLOWING MINIMUM <br /> CLEARANCES SHALL APPLY BETWEEN THE FACE OF REINFORCING AND <br /> F. ALL REINFORCING SHALL BE STRAIGHT EXCEPT WHERE SHOWN ON PLANS <br /> G. WELDED WIRE FABRIC IN CONCRETE SLABS SHALL BE ACCURATELY CUT <br /> AND LAID FLAT WITH SHEETS OF FABRIC LAPPED AT LEAST ONE <br /> SPACE. TIE SHEETS TO EACH OTHER AT 24" O/C AND TO CONTIGUOUS <br /> REINFORCING BARS. AS CONCRETE IS PLACE THE FABRIC SHALL BE <br /> H. UNLESS OTHERWISE NOTED ON THE PLANS, DOWELS FROM THE FOOTINGS <br /> TO THE MASONRY WALL SHALL BE PROVIDED OF THE SAME SIZE AND <br /> SPACING AS THE VERTICAL REINFORCING SPECIFIED IN THE WALLS. <br /> VERTICAL BARS IN MASONRY WALLS SHALL BE ACCURATELY POSITIONED <br /> AT THE CENTER OF WALL (U.N.O.) AND SHALL BE TIED IN POSITION <br /> AT TOP AND BOTTOM AND AT INTERVALS PER CHAPTER 26 OF THE 1994 <br /> I. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND INSERTS SHALL <br /> BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. <br /> SPLICES SHALL BE A MINIMUM OF 24, 30, OR 36 BAR DIAMETERS FOR <br /> 40, 50 AND 60 PSI YIELD STRENGTH RESPECTIVELY. <br /> THE FACE OF THE CONCRETE. <br /> BENDS AT CORNERS <br /> LIFTED TO INSURE PROPER PLACEMENT. <br /> BEAMS, GIRDERS AND COLUMNS SLABS. <br /> SLABS AND WALLS <br /> SURFACE OF FOOTINGS IN CONTACT WITH GROUND. <br /> FORMED SURFACES IN CONTACT W/ GROUND/WEATHER. <br />REINFORCEMENT <br /> WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br /> STEEL & CONCRETE. <br /> FOOTINGS STD. 2500 3/4" 5.25 SACKS 4 INCH <br /> A. ALL AGGREGATES SHALL CONFORM TO ASTM C-33-71, EXCEPT AS <br /> A. SHALL BE PORTLAND CEMENT: CONFORMING TO ASTM C-150 AND <br /> A. ALL WATER SHALL BE POTABLE, CLEAN AND FREE FROM DELETERIOUS <br /> CEMENT DELIVERED TO THE PLANT SHALL NOT EXCEED 150 DEGREES F. <br /> SHALL BE THE PRODUCT OF ONE MANUFACTURER. THE TEMPERATURE OF <br /> MEMBRANES SHALL BE SHEET PLASTIC OR AN EQUAL APPROVED IN <br /> FOR A COMPLETE AND PROPER INSTALLATION OF CAST-IN-PLACE <br /> ELEVATIONS INDICATED ON THE DRAWINGS, WITH ALL REQUIRED <br /> VERIFY THAT CONCRETE MAY BE PLACED TO THE LINES AND <br /> A. ALL OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED <br /> BLDG. SLAB STD. 2500 3/4" 5.75 SACKS 4 INCH <br /> FOOTINGS STD. 2500 3/4" 5.50 SACKS 4 INCH <br /> C. VERIFY THAT ALL ITEMS TO BE EMBEDDED IN CONCRETE ARE IN PLACE <br /> GROUP AND SHALL BE A TYPE APPROVED BY THE GOVERNING BUILDING <br /> B. ADMIXTURES MAY BE USED ONLY WITH THE CONSENT OF MPA ARCHITECTURAL <br /> CONCRETE SHALL BE AS SELECTED BY THE CONTRACTOR SUBJECT TO <br /> ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MEMBRANE BEING <br /> A. ALL CEMENT OR TAPE USED FOR SEALING MEMBRANE JOINTS SHALL BE <br /> A. UNLESS OTHERWISE SPECIFIED BY THE SOILS ENGINEER, ALL CURING <br /> CLEARANCE FROM REINFORCEMENT. <br /> MODIFIED HEREIN. <br /> 7. CURING MEMBRANES: <br /> ADVANCE BY MPA ARCHITECTURAL GROUP. <br /> DEPARTMENT. <br /> THE APPROVAL OF MPA ARCHITECTURAL GROUP <br /> 8. JOINTING MATERIAL: <br /> 9. OTHER MATERIALS: <br /> JOINED. <br /> MATTER. <br /> 5. AGGREGATES: <br /> A. ALL SLABS ON GRADE SHALL BE REINFORCED AS NOTED ON FOUNDATION <br />PLAN. SLAB SHALL BE POURED OVER SUB-GRADE AS NOTED ON ALL <br /> AREAS TO RECEIVE CONCRETE SLABS ON GRADE, UNIFORMLY <br /> ATTAINING THE THICKNESS ON THE DRAWINGS AND PROVIDING ALL <br /> A. UNLESS OTHERWISE SPECIFICALLY PERMITTED IN WRITING BY MPA <br />ARCHITECTS, INC., ALL CONCRETE SHALL BE TRANSIT-MIXED IN ACCORDANCE <br />W/ ASTM C-94. CONCRETE SHALL BE DENSE, FREE FROM HONEYCOMBING OR <br /> A. UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWINGS, ALL <br /> CONCRETE SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE <br /> STRENGTHS AT 28 DAYS AND SHALL BE PROPORTIONED WITHIN THE <br /> CONCRETE MIN. PSI MAX SIZE MIN SACKS MAX SLUMP <br /> LOCATION @ 28 DAYS AGGREGATE CEMENT/CU.YD. IN INCHES <br /> FOLLOWING LIMITS: <br /> REQUIRED TRANSITION PLANES. <br />CONCRETE <br /> 6. WATER: <br /> 4. CEMENT: <br /> 3. QUALITY: <br /> 2. GENERAL: <br /> 1. SLABS: <br /> UBC. <br /> 1. STEEL: <br /> PRACTICE" <br />2.00" <br />3.00" <br />1.75" <br />1.50" <br />OTHER DEFECTS. <br /> UNIFORM LAYER OF SAND TWO (2) INCHES THICK OVER MEMBRANE <br /> (d) EXERCISE CARE TO AVOID PUNCTURING THE MEMBRANE OR <br /> AND LAID FLAT WITH SHEETS OF FABRIC LAPPED AT LEAST ONE <br /> THE SLAB. PROVIDE ONE CONSTRUCTION JOINT FOR APPROXIMATELY <br /> JOINTS SHALL BE PLACED UNDER PARTITIONS IN THE INTERIOR OF <br /> DISPLACING OR OPENING LAP JOINTS. PLACE NO LOADS ON <br /> A. UNLESS OTHERWISE DETAILED ON THE DRAWINGS, CONSTRUCTION <br /> C. REFER TO THE FOUNDATION PLAN FOR ADDITIONAL SPECIFICATIONS. <br /> REINFORCING BARS. AS CONCRETE IS PLACE THE FABRIC SHALL BE <br /> SPACE. TIE SHEETS TO EACH OTHER AT 24" O/C AND TO CONTIGUOUS <br /> B. WELDED WIRE FABRIC IN CONCRETE SLABS SHALL BE ACCURATELY CUT <br /> SAND AND ALLOW NO TRAFFIC ON SAND BEFORE SLAB IS POURED. <br /> LIFTED TO INSURE PROPER PLACEMENT. <br /> ADDITIONAL INFORMATION APPLICABLE TO THIS SECTION <br /> E. SEE AMERICANS WITH DISABILITIES ACT/TITLE 24 NOTES FOR <br /> D. SEE "REINFORCEMENT NOTES" <br /> BEFORE THE CONCRETE SLAB IS POURED. <br /> 1500 SQUARE FEET OF SLAB AREA. <br />17. MISCELLANEOUS: <br /> COMPACTED FILL. TERMITE SOIL TREATMENT SHALL THEN BE <br /> (a) PLACE REQUIRED LAYER OF FREE DRAINING GRAVEL OVER <br /> PIPES, CONDUITS, COLUMNS AND OTHER PROTRUSIONS. COAT <br /> IN THE WIDEST PRACTICAL WIDTHS. LAP SIDE AND END JOINTS <br /> (b) AFTER TERMITE SOIL TREATMENT IS COMPLETE, APPLY MEMBRANE <br /> PROOF BY USING SMALL PIECES OF MEMBRANE AND A LIBERAL <br /> WIDE. AREAS SURROUNDING PROTRUSIONS SHALL BE MADE DAMP <br /> LAPS WITH A BED OF MASTIC NOT LESS THAN THREE (3) INCHES <br /> AT LEAST SIX (6) INCHES AND FIT MATERIAL CLOSELY AROUND <br /> APPLIED AS SPECIFIED ELSEWHERE. <br /> AMOUNT OF MASTIC. <br /> D. INSTALLATION: <br /> D. FORMS SHALL BE SUBSTANTIAL, UNYIELDING, TRUE TO LINE, PLUMB, <br /> UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED. <br /> D. WHERE NO EXTERIOR SLAB FINISH IS INDICATED ON THE DRAWINGS <br /> A. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, MAKE ALL SLABS <br /> D. THOROUGHLY CLEAN ALL TRANSPORTING AND HANDLING EQUIPMENT. <br /> OPERATIONS, IF REQUIRED TO KEEP CONCRETE MOIST. IMMEDIATELY <br /> EXCESSIVELY CRACKED OR HAS POCKETS OR HONEYCOMBS, OR IS <br /> B. DURING PERIODS OF LOW HUMIDITY, WINDS, OR TEMPERATURES IN <br /> A. ALL AREAS SHALL BE FOG SPRAYED IMMEDIATELY AFTER FINISHING <br /> ACCORDANCE WITH THE PLANS AND SPECIFICATIONS, SHALL BE <br /> B. MASTIC SHALL BE BLACK PLASTIC CEMENT BY JOHN-MANSVILLE <br /> DEFECTIVE IN ANY OTHER WAY, OR WAS NOT CONSTRUCTED IN <br /> CEMENT. THE CONTRACTOR SHALL BE ENTIRELY RESPONSIBLE FOR THE <br /> LEVEL AND SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF MORTAR OR <br /> B. WHERE FLOOR DRAIN OR FLOOR SLOPES ARE INDICATED, SLOPE SLABS <br /> UNIFORM IN APPEARANCE AND EVEN WITHIN PLUS OR MINUS 1/8" IN <br /> C. THOROUGHLY WET THE FORMS OR OIL THEM. REMOVE ALL STANDING <br /> B. THOROUGHLY CLEAN THE AREAS TO ENSURE PROPER PLACEMENT AND <br /> A. REMOVE ALL WOOD SCRAPS AND DEBRIS FROM THE AREAS IN WHICH <br /> GROUP. DO NOT PROCEED WITH INSTALLATION IN AREAS OF DISCREPANCY <br /> A. IN THE EVENT OF DISCREPANCY, IMMEDIATELY NOTIFY MPA ARCHITECTURAL <br /> DESIGN, CONSTRUCTION SAFETY, AND STRUCTURAL ADEQUACY OF THE <br /> A. ANY CONCRETE THAT DOES NOT COME UP TO STRENGTH IN 28 DAYS, IS <br /> FORMS AND EXPOSED CONCRETE SHALL BE KEPT CONTINUOUSLY MOIST <br /> A. WET ALL FOOTING FORMS AT LEAST TWICE DAILY UNTIL REMOVAL. ALL <br /> D. APPLY "HUNTS PROCESS CLEAR" IMMEDIATELY AFTER FOG SPRAYING OR <br /> AND PROTECTED AGAINST INJURY AND DEFACEMENT OF ANY NATURE <br /> C. EXTERIOR CONCRETE SLABS AND PAVING SHALL BE PROPERLY CURED <br /> AFTER FOG SPRAYING APPLY THE CURING COMPOUND SPECIFIED BELOW. <br /> PERIOD OF 4 HOURS. FOG SPRAY PRIOR TO AND DURING FINISHING <br /> EXCESS OF 70 DEGREES F., THE FOG SPRAY SHALL BE APPLIED FOR A <br /> C. SAND SHALL BE CLEAN RIVER SAND, APPROVED BY MPA ARCHITECTURAL <br /> THICK, UNLESS OTHERWISE NOTED, AS MANUFACTURED BY MONSANTO <br /> A. MEMBRANE SHALL BE MONSANTO POLYETHYLENE SHEETING SIX (6) MIL <br /> REPLACED IN ACCORDANCE WITH INSTRUCTIONS FROM MPA ARCHITECTURAL <br /> B. ALL DEFECTIVE CONCRETE SHALL BE REMOVED FROM THE WORK AND <br /> FINISH THE EXPOSED CONCRETE SURFACE BY LIGHTLY COMBING WITH A <br /> FOR A PERIOD OF SEVEN DAYS AFTER PLACING. <br /> KEEP SURFACE CONTINUOUSLY WET FOR THE FIRST 7 DAYS. <br /> DURING CONSTRUCTION OPERATIONS. <br />15. MAJOR DEFECTIVE AREAS: <br /> BORNE BY THE CONTRACTOR. <br /> PLASTICS AND RESINS COMPANY, KEN, N.J. AND ANAHEIM, <br /> GROUP, COST OF REMOVAL AND REPLACEMENT SHALL BE <br /> CONSIDERED AS DEFECTIVE CONCRETE. <br />16. WATERPROOFING UNDER SLAP: <br /> CALIFORNIA. <br /> BONDING OF CEMENT. <br /> CONCRETE WILL BE PLACED. <br /> FORMWORK, SHORES, SUPPORTS OR BRACES. <br /> UNIFORMLY TO PROVIDE EVEN FALL FOR DRAINING. <br /> C. TROWEL ALL INTERIOR SLABS TO A SMOOTH, HARD FINISH. <br /> MEDIUM STIFF BROOM AFTER TROWELING IS COMPLETE. <br /> OPERATIONS FOR A PERIOD OF 2 HOURS. <br />10. DISCREPANCIES: <br /> APPROVED BY MPA ARCHITECTURAL GROUP, PLACE A <br /> (c) AFTER THE MEMBRANE INSTALLATION HAS BEEN INSPECTED AND <br /> GROUP. <br /> COMPANY. <br />13. CURING: <br />14. FORMS: <br />12. FINISHING: <br /> TEN FEET. <br />11. GENERAL: <br /> WATER. <br /> 7. WEATHERSTRIPPING: <br /> REGARDING GLASS SLIDING DOORS. <br /> GASKETS TO LIMIT AIR INFILTRATION. <br /> 6. SLIDING DOORS: <br />SECURITY <br /> 1. GENERAL: <br /> FORCED ENTRY RESISTANCE: <br /> NOT LESS THAN 9/16 INCHES THICKNESS, PROVIDED SHAPED <br /> (b) WOOD PANEL TYPE DOORS WITH PANELS FABRICATED OF LUMBER <br /> (a) SOLID CORE DOORS NOT LESS THAN 1-3/8 INCHES IN THICKNESS. <br /> CONSTRUCTIONS OR SHALL BE OF A CONSTRUCTION HAVING EQUIVALENT <br /> WITHOUT THE USE OF A KEY SHALL BE OF ONE OF THE FOLLOWING <br /> A. SWINGING WOODEN DOORS WHICH ARE OPENABLE FROM THE INSIDE <br /> A. SLIDING DOORS SHALL BE SECURED WITH HOOKBOLT DEADBOLTS. <br /> B. SEE GLAZING SPECIFICATIONS FOR ADDITIONAL INFORMATION <br /> C. SEE SECURITY SPECIFICATIONS FOR ADDITIONAL INFORMATION. <br /> B. ALL GLASS DOORS SHALL COMPLY WITH AIR INFILTRATION STANDARDS <br /> 8. SEE AMERICANS WITH DISABILITIES ACT/TITLE 24 NOTES FOR <br /> OF THE 1972 ANSI A-134.1; A-134.2; A-134.3; A-134.4. <br /> ADDITIONAL INFORMATION APPLICABLE TO THIS SECTION <br /> OF NOT LESS THAN 3/8 INCHES. <br /> 2. LOCKS/DEADBOLTS: <br /> THE ACTIVE LEAF OR LOWER LEAF. <br /> THE DOOR. <br /> EXCEPTIONS: <br /> SECT. 91.6731 SNA 91.6732. <br /> CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING <br /> G. SLIDING DOORS SHALL BE PROVIDED WITH A DEVICE IN THE UPPER <br /> INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN <br /> AND SHALL BE CONSTRUCTED AND INSTALLED THAT THEY REMAIN <br /> F. SLIDING GLASS DOORS SHALL BE EQUIPPED WITH LOCKING DEVICES <br /> E. STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN <br /> FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO ATTACK TOOLS. <br /> DEADBOLTS WHENEVER THE CYLINDER PROJECTS BEYOND THE OUTSIDE <br /> C. CYLINDER GUARDS SHALL BE INSTALLED ON CYLINDER LOCKS FOR <br /> NOT PROHIBITED BY OTHER LAWS AND REGULATIONS. <br /> THE DEVICE RECEIVING THE PROJECTED BOLT MAY BE USED WHEN <br /> OF THE LEAF AND WHICH EMBED A MINIMUM OF 1/2 INCH INTO <br /> (c) MANUALLY OPERATED HARDENED BOLTS AT THE TOP AND BOTTOM <br /> AUTOMATICALLY WITH THE DEADBOLT OR BY ANOTHER DEVICE ON <br /> (b) THE BOLT OR BOLTS MAY BE ENGAGED OR DISENGAGED <br /> NOT BE OTHERWISE ACTIVATED, FROM THE EXTERIOR SIDE OF <br /> (a) THE BOLT OR BOLTS NEED NOT BE KEY OPERATED, BUT SHALL <br /> DUTCH DOORS SHALL BE EQUIPPED WITH A DEADBOLT OR DEADBOLTS. <br /> B. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF <br /> HOLDING DEVICES RECEIVING THE PROJECTED BOLTS. <br /> LEAST 1/2 INCH, BUT NEED NOT EXCEED 3/4 INCH, INTO THE <br /> AUTOMATICALLY ACTIVATE TWO OR MORE DEADBOLTS SHALL EMBED AT <br /> MINIMUM THROW OF 2/3 INCH. ALL DEADBOLTS OF LOCKS WHICH <br /> BOLT. A HOOK SHAPE OR EXPANDING LUG DEADBOLT SHALL HAVE A <br /> 5/8 INCH INTO THE HOLDING DEVICE RECEIVING THE PROJECTED <br /> THROW OF ONE INCH AND THE EMBEDMENT SHALL NOT BE LESS THAN <br /> EXCESSIVE FORCE. A STRAIGHT DEADBOLT SHALL HAVE A MINIMUM <br /> SIDE OF THE DOOR BY A DEVICE NOT REQUIRING A KEY, TOOL, OR <br /> SIDE OF THE DOOR AND ENGAGED OR DISENGAGED FROM THE INTERIOR <br /> BOLT LOCK OR LOCKS SHALL BE KEY OPERATED FROM THE EXTERIOR <br /> OR EQUIVALENT, SO AS TO REPEL CUTTING TOOL ATTACK. THE DEAD <br /> INDIVIDUAL LOCKS. DEADBOLTS SHALL CONTAIN HARDENED INSERTS, <br /> DEADBOLT. THE DEADBOLT MAY BE ACTIVATED BY ONE LOCK OR BY <br /> AND THE BOTTOM LEAF OF DUTCH DOORS SHALL BE EQUIPPED WITH A <br /> A. A SINGLE SWINGING DOOR, THE ACTIVE LEAF OF A PAIR OF DOORS <br /> INCHES MAXIMUM CENTERS AROUND THE PERIMETER. <br /> WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT SIX <br /> THICKNESS EITHER OF WHICH ARE COVERED ON THE INSIDE FACE <br /> (c) HOLLOW CORE DOORS OR DOORS LESS THAN 1-3/8 INCHES IN <br /> LESS THAN 2 INCHES. CARVED AREAS SHALL HAVE A THICKNESS <br /> OVER 18 INCHES LONG MAY HAVE AN OVERALL WIDTH OF NOT <br /> REQUIRED HEREIN FOR STILES AND RAILS EXCEPT MULLIONS NOT <br /> CONSIDERED A PART OF ADJACENT PANELS UNLESS SIZED AS <br /> THICKNESS AND 3 INCHES IN WIDTH. MULLIONS SHALL BE <br /> OVERALL DIMENSIONS OF NOT LESS THAN 1-3/8 INCHES IN <br /> AREA. STILES AND RAILS SHALL BE OF SOLID LUMBER WITH <br /> INDIVIDUAL PANELS SHALL NOT EXCEED 300 SQUARE INCHES IN <br /> EMBEDMENT OF NOT LESS THAN 5/8 INCHES. <br /> D. DEADBOLTS SHALL CONTAIN HARDENED INSERTS. <br /> PORTIONS OF THE PANELS ARE NOT LESS THAN 1/4 INCH THICK. <br /> 4. SIDELIGHTS/DOOR LIGHTS: <br /> INCHES IN LENGTH. <br /> HINGE PINS ARE REMOVED. <br /> 3. DOOR HARDWARE: <br />SUSPENDED CEILING SYSTEM <br /> BELOW THE THRESHOLD. <br /> EXCESS OF 15 POUNDS. <br /> APPLICABLE. <br /> 6. MISCELLANEOUS: <br /> SQUARE FOOT SHALL BE USED. <br /> SHALL BE PLACES 12 FEET ON CENTER IN EACH DIRECTION WITH THE <br /> FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORT POINTS <br /> TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES <br /> CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSSRUNNER AND <br /> 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND <br /> A. LATERAL SUPPORT MAY BE PROVIDED BY FOUR WIRES OF MINIMUM NO. <br /> AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, AND <br /> 2. WHERE THE CEILING LOADS DO NOT EXCEED FIVE POUNDS PER SQUARE FOOT <br /> THE LATERAL FORCE, A MINIMUM CEILING WEIGHT OF 5 POUNDS PER <br /> ANY LOADS TRIBUTARY TO THE SYSTEM. FOR PURPOSES OF DETERMINING <br /> LATERAL FORCE OF 20% OF THE WEIGHT OF THE CEILING ASSEMBLY AND <br /> 1. SUSPENDED CEILING FRAMING SYSTEMS SHALL BE DESIGNED TO RESIST A <br /> ADDITIONAL INFORMATION APPLICABLE TO THIS SECTION <br /> D. SEE AMERICANS WITH DISABILITIES ACT/TITLE 24 NOTES FOR <br /> C. ALL DOORS MUST OPEN OVER A LANDING NOT MORE THAN 1/2 INCH <br /> B. DOOR CLOSERS FOR FIRE EXIT DOORS SHALL NOT REQUIRE A FORCE IN <br /> A. SEE STOREFRONT SPECIFICATIONS SHEET FOR ADDITIONAL WHERE <br /> BY METAL BARS, SCREENS, OR GRILLES IN AN APPROVED MANNER. <br /> A LEAST DIMENSION EXCEEDING EIGHT (8) INCHES SHALL BE SECURED <br /> C. OTHER OPENINGS EXCEEDING NINETY-SIX (96) SQUARE INCHES WITH <br /> BAR, SLIDE BOLT, AND/OR PADLOCK WITH A HARDENED STEEL SHACKLE. <br /> B. THE HATCHWAY SHALL BE SECURED FROM THE INSIDE WITH A SLIDE <br /> WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT SIX (6) <br /> 1-3/4 INCHES THICK SOLID WOOD SHALL BE COVERED ON THE INSIDE <br /> A. WOODEN HATCHWAYS, SCUTTLES, AND SIMILAR OPENINGS LESS THAN <br /> 5. WOODEN HATCHWAYS, SCUTTLES, AND SIMILAR OPENINGS: <br /> BARS, SCREENS OR GRILLED IN AN APPROVED MANNER. <br /> APPROVED BURGLARY RESISTANT MATERIAL, OR GUARDED BY METAL <br /> FORTY-EIGHT (48) INCHES SHALL BE FULLY TEMPERED GLASS, <br /> LEAST DIMENSION GREATER THAN SIX (6) INCHES, BUT LESS THAN <br /> FROM THE INSIDE WITHOUT THE USE OF A KEY, AND LIGHTS WITH A <br /> ON A DOOR WHEN IN THE CLOSED AND LOCKED POSITION AND OPENABLE <br /> A. LIGHTS WITHIN FORTY (40) INCHES OF A REQUIRED LOCKING DEVICE <br /> THE JAMB AND THE WALL FRAMING WITH SCREWS NOT LESS THAN 2-1/2 <br /> PROJECTING DEADBOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO <br /> B. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR <br /> THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE <br /> DIAMETER STEEL JAMB STUD WITH 1/4" MINIMUM PROTECTION UNLESS <br /> HINGE PINS. IN ADDITION, THEY SHALL HAVE A MINIMUM 1/4" <br /> SECURED AREA WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE <br /> A. ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM THE OUTSIDE THE <br /> FIRST POINT WITHIN 4 FEET FROM EACH WALL. <br /> FOLLOWING BRACING METHOD MAY BE EMPLOYED: <br /> INCH MAXIMUM CENTERS AROUND THE PERIMETER. <br /> A WALL. <br /> DISCONTINUITIES AS MAY OCCUR WHERE THE CEILING IS DISRUPTED BY <br /> RUNNERS BE VERTICALLY SUPPORTED WITHIN 8 INCHES OF SUCH <br /> REQUIREMENTS THAT DISCONTINUOUS ENDS OF CROSS RUNNERS AND MAIN <br /> C. VERTICAL SUPPORT SHALL BE PROVIDED AS REQUIRED WITH THE ADDED <br /> ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE <br /> MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED AT TWO <br /> RUNNERS MAINTAINED AT THE OTHER TWO WALLS. <br /> B. ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM. <br /> OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. <br /> 1. METAL DOORS & STEEL FRAMES <br />DOORS <br />GYPSUM WALLBOARD <br /> 1. GENERAL <br /> DOOR SCHEDULE. <br /> DOORS. <br /> FRAMING IS COVERED. <br /> THAN 1" X 2". <br /> FRAMING. <br /> PANELS. <br /> JOINTS PERPENDICULAR TO THE MAIN FRAMING. THE EDGES AND <br /> FASTENERS SHALL HOLD THE PANELS IN FIRM CONTACT WITH <br /> C. FRAMING: WOOD FRAMING SHALL BE STRAIGHT AND TRUE. WOOD <br /> CEILING STRIPPING SHALL BE 2" X 2" MINIMUM FOR NAILING AND <br /> SHALL NOT BE LESS THAN 3/8" FROM EDGES OR ENDS OF THE <br /> OF WALLBOARD SHEET LOCATED OVER FRAMING MEMBERS, EXCEPT FOR <br /> ENDS ADJOINING SHEETS SHALL BE IN MODERATE CONTACT AND THE <br /> B. GYPSUM WALLBOARD SHALL NOT BE INSTALLED UNTIL ALL EXTERIOR <br /> 1" X 3" FOR SCREW ATTACHMENT OTHER FURRING SHALL BE NOT LESS <br /> D. ATTACHMENT: FASTENERS SHALL NOT FRACTURE THE FACE PAPER AND <br /> A. GYPSUM WALLBOARD SHALL BE INSTALLED WITH ALL EDGES AND ENDS <br /> EQUAL. DOORS SHALL BE 1-3/4 INCHES THICK UNLESS OTHERWISE <br /> C. STEEL FRAMES SHALL BE A COMBINATION TYPE OF FRAME WITH <br /> INTEGRAL TRIM AND SHALL BE FABRICATED FROM AT LEAST 16 GAUGE <br /> COLD-ROLLED STEEL. CORNERS SHALL BE MITERED AND WELDED THE <br /> FULL LENGTH OF JOINTS AND GROUND SMOOTH, THE BOTTOM OF EACH <br /> D. HOLLOW METAL DOORS SHALL BE FACED WITH 18 GAUGE COLD-ROLLED <br /> STEEL, REINFORCED AT 16" ON CENTER AND FILLED WITH INORGANIC <br /> INSULATION OR SOUND DEADENING MATERIAL. WHERE THE DOORS AND <br /> FRAMES ARE SCHEDULED TO BE LABELED, THEY SHALL BEAR THE UL <br /> CLASSIFICATION MARKING OF THE FIRE RATING INDICATED IN THE <br /> E. A RUST INHIBITING PRIMER SHALL BE APPLIED TO ALL HOLLOW METAL <br /> F. DOORS AND JAMBS SHALL BE INSTALLED PURSUANT TO THE <br /> MANUFACTURER'S SPECIFICATIONS. WHEN FRAMES ARE INSTALLED IN <br /> MASONRY WALLS USE 'T' ANCHORS, 3 JAMBS AND TWO AT THE HEAD. <br /> NOTED ON ARCHITECTURAL DRAWINGS. <br /> FRAME SHALL HAVE A REMOVABLE STEEL SPREADER. <br /> A. SEE SECURITY SPECIFICATIONS FOR ADDITIONAL INFORMATION <br /> B. HOLLOW METAL DOORS AND PRESSED STEEL FRAMES SHALL BE EQUAL TO <br /> UNITED STATES ALUMINUM CORPORATION, SECURITY METAL PRODUCTS <br /> OR ENGINEERING METALS OF SOUTHERN CALIFORNIA OR APPROVED <br /> APPLICABLE TO DOOR SPECIFICATIONS <br /> PROVIDED A CONTINUOUS BEAD OF ADHESIVE, SUFFICIENT IN SIZE <br /> THE MAIN FRAMING MEMBERS, FASTENERS ARE USED. TWO <br /> MAY BE APPLIED TO FRAMING MEMBERS AT 16 INCHES ON CENTER <br /> AND THE FACE LAYER LAMINATED WITH AN ADHESIVE. OTHER <br /> TWO-PLY APPLICATIONS OF GYPSUM WALLBOARD AND STUDLESS <br /> PARTITIONS MAY BE PERMITTED WHEN THE INSTALLATION IS <br /> E. SINGLE-PLY GYPSUM MAY BE ADHESIVELY APPLIED TO WOOD-FRAMING, <br /> TO PRODUCE TO 1/16" THICK BY 1" WIDE CONTACT, IS APPLIED TO <br /> CONTINUOUS BEADS OF ADHESIVE ARE REQUIRED WHERE EDGE OR END <br /> F. TWO-PLY APPLICATIONS: TWO LAYERS OF 3/8" GYPSUM WALLBOARD <br /> WITH THE BASE LAYER NAILED AS REQUIRED FOR 1/2" WALLBOARD <br /> APPROVED BY THE BUILDING DEPARTMENT. <br /> JOINT OCCUR OVER A SINGLE MEMBER. <br /> 2. DOUBLE DOORS: <br /> THRESHOLDS. <br /> 4. STOREFRONT AND WINDOWS: <br /> 5. DOOR HARDWARE: <br /> A. INACTIVE LEAF SHALL BE SECURED WITH FLUSHBOLTS AT HEAD AND <br /> THE LOCAL CITY BUILDING CODE AND THE ARCHITECTURAL BARRIERS <br /> LAWS OF TITLE 24 AND A.D.A. ALL EXTERIOR SWINGING DOORS <br /> (a) EXTERIOR - DEADLOCKING LATCH KEY OPERATED LOCK <br /> (b) INTERIOR - OPENABLE WITHOUT KEY IN A SINGLE EFFORT, <br /> B. ALL INTERIOR DOOR HARDWARE SHALL BE OF A LEVER, TOGGLE OR <br /> PUSH-PULL TYPE. CLOSERS ON ALL INTERIOR DOORS SHALL NOT <br /> C. SEE SECURITY SPECIFICATIONS FOR ADDITIONAL INFORMATION. <br /> WITHOUT SPECIAL KNOWLEDGE. <br /> EXCEED A PRESSURE OF 5 POUNDS. <br /> A. SEE STOREFRONT SPECIFICATION SHEET. <br /> SHALL HAVE DEADBOLTS WITH HARDENED INSERTS. <br /> 3. FIXTURES AND DIFFUSERS: <br /> TRUSSES. <br /> RUNNERS. <br /> TO THE CEILING. <br /> BE INSTALLED A MINIMUM OF 8" BELOW THE BOTTOM CHORD OF ROOF <br /> T-BAR SHALL BE DIRECTLY BELOW THE TRUSS CHORD. THE CEILING SHALL <br /> EVER POSSIBLE AND WHERE THE TRUSS SPACING IS 24" ON CENTER THE <br /> POSITIVELY ATTACHED TO AND SUPPORTED BY THE CEILING <br /> WHICH RECEIVE NO TRIBUTARY LOADING FROM DUCT WORK MAY BE <br /> (b) AIR DIFFUSERS WHICH WEIGH NOT MORE THAN 20 POUNDS, AND <br /> POUNDS IN WEIGHT, MAY BE SUPPORTED AND ATTACHED DIRECTLY <br /> MAY BE SUSPENDED AND PENDANT HUNG FIXTURES NOT OVER 20 <br /> (a) RECESSED LIGHTING FIXTURES NOT OVER 56 POUNDS IN WEIGHT, <br /> DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. EXCEPTION: <br /> A. LIGHTING FIXTURES AND AIR DIFFUSERS SHALL BE SUPPORTED