Laserfiche WebLink
M <br />P <br /> <br />A <br /> <br /> <br /> <br /> <br />A <br /> <br />R <br /> <br />C <br /> <br />H <br /> <br />I <br /> <br />T <br /> <br />E <br /> <br />C <br /> <br />T <br /> <br />S <br /> <br /> <br /> <br /> <br />I <br /> <br />N <br /> <br />C <br /> <br />. <br />3578 30th Street <br />V. 619.236.0595 <br />San Diego, CA 92104 <br />MEMBER <br />www.mpa-architects.com <br />AMERICAN INSTITUTE OF ARCHITECTS <br />F. 619.236.0557 <br />CLIENT <br />PROJECT <br />DATENO. <br />REVISIONS <br />DESCRIPTION <br />AS NOTED <br />c <br />Co <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br /> <br />2 <br />0 <br />2 <br />5 <br />, <br /> <br />M <br />P <br />A <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />. <br /> <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />DRAWN BY: <br />DATE: <br />JP <br />JR <br />24190 <br />PROJECT NO: <br />CHECKED BY: <br />SHEET TITLE <br />SCALE: <br />SHEET NUMBER: <br />DATABASE: <br />A <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> F <br />O <br />R <br />: <br />1-23-25 <br />24190.DWG <br />CEC BUILDERS <br />cecbuilders1@gmail.com <br />P: 303.842.6645 <br />ROBERT BARILE <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />L <br />A <br />U <br />N <br />D <br />R <br />Y <br />25 <br />0 <br />2 <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br />18723 VIA PRINCESSA, STE 321 <br />SANTA CLARITA, CA 91387 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIA <br />NHOJ <br />R UMSEY <br />C26819 <br />Exp. 3-31-2027 <br />A4.0 <br />DETAILS <br />SINGLE ACCOMMODATION TOILETS <br />Definition: Single-Accommodation Sanitary Facility. <br />Single-accommodation sanitary facility is a room that has not more than one of each type of sanitary fixture, is intended for use by only <br />one person at a time, has no partition around the toilet and has a door that can be locked on the inside by the room occupant. <br />Accessible Fixtures. <br />Single-accommodation toilet facilities shall provide one accessible water closet and one accessible lavatory. <br />Clear Floor Space at Fixtures. <br />Doors shall not swing into the clear floor space required for any fixture. <br />Accessible Route. <br />All doors, fixtures and controls shall be on an accessible route. <br />Privacy Latch. <br />The entrance door to a single-accommodation toilet room shall contain a privacy latch. <br />a) Except at doors, the minimum clear width of the accessible route(s) is 36". <br /> 1. When the accessible route makes a 180-degree turn around an obstruction that is less than 48" wide, the clear width is 42" minimum <br />approaching the turn, 48" minimum at the turn and 42" minimum leaving the turn. <br /> 2. When the accessible route makes a 180-degree turn around an obstruction that is a minimum of 60" wide, the clear width is 36" <br />minimum approaching the turn, 60" minimum at the turn and 36" minimum leaving the turn. <br />b) The entry door has a privacy latch (push button-lever release recommended). <br />c) The entrance door to the single-accommodation restroom is accessible. <br />d) Sufficient space is provided for a wheelchair measuring 30" wide x 48" long to enter the room and permit the door to close. <br />e) A clear space of sufficient size to inscribe a 60" diameter circle, or a T-shaped clear space, is provided within the sanitary facility room. <br /> 1. The clear space is clear of objects from the floor to a height of 27". <br /> 2. No door encroaches more than 12" into the required clear space. <br />f) The centerline of the water closet is located at 17"-18" distance from the side-wall or partition. <br />g) If the water closet IS ADJACENT to another fixture, a minimum 60"-wide clear floor space is provided from the wall to the adjacent <br />fixture, and extends from the rear wall to the front of the water closet. <br />h) A minimum 60" wide and 48" deep clear floor space is provided in front of the water closet. <br />i) The top of the toilet seat is 17"-19" from floor surface measured to the top of a maximum 2" high toilet seat. <br />j) The flush valve is on the wide side of the toilet area. <br />k) The flush valve is a maximum of 44" distance above the floor. <br />l) Water closet controls are operable with one hand and do not require tight grasping, pinching or twisting. <br />m) 5lb maximum force is required to operate the flush valve. <br />n) Walls within compartment are smooth, hard and non-absorbent to 48" in height, installed over moisture resistant gypsum board (or <br />equivalent) and are not adversely affected by moisture (Portland cement, concrete, ceramic tile or other approved material). <br />o) Toilet room floor surfaces are smooth, hard and non-absorbent extending upward a minimum of 5" onto walls (Portland cement, <br />concrete, ceramic tile or other approved material). <br />p) Grab bars within the accessible compartment are provided on the side wail closest to the water closet and on the rear wall. <br />q) The side grab ban's a minimum of 42" in length. <br />r) The side grab bar begins a maximum of 12" from the rear wall. <br />s) The front end of the side grab bar is positioned a minimum of 24" in front of the water closet. <br />t) The front end of the side grab bar is located a minimum of 54" from the rear wall. <br />u) The side grab bar does not project more than 3" into the required clear floor space. <br />v) The side grab bar is securely attached and is mounted at 33-36" to the top of the gripping surface, above and parallel to floor. <br />w) Rear grab bar is a minimum 36" long. <br />x) The rear grab bar extends from the centerline of the water closet 12" minimum on one side and 24" minimum on the other side. <br />y) The rear grab bar does not project more than 3" into the required clear floor space. <br />z) The rear grab bar is securely attached and is mounted at 33"-36" to the top of the gripping surface, above and parallel to floor (for tank <br />type toilets, 36" may be allowed if tank obstructs placement of bar). <br />aa) The space between the rear grab bar and the top of the toilet tank is a minimum of 1-1/2". <br />bb) The diameter or width of the gripping surfaces of the grab bar(s) are 1-1/4" to 1-1/2" or the shape provides an equivalent gripping <br />surface. <br />cc) The clearance between the grab bar(s) and wall is 1-1/2". <br />dd) Minimum structural strength of grab bar(s) will support a 250 Ib. point load. <br />ee) The grab bar(s) and any wall or other surface adjacent to it is free of any sharp or abrasive elements. <br />ff) Any edges on the grab bar(s) have a minimum radius of 1/8". <br />gg) Grab bars do not rotate within their fittings. <br />hh) The toilet paper dispenser is located on the side wall below the grab bar within 7" to 9" of the front edge of the toilet seat. <br />ii) The toilet paper dispenser is mounted at a minimum height of 19" from the floor to the centerline of the dispenser. <br />jj) The toilet paper dispenser is mounted a maximum distance of 36" from the rear wall to the front of the dispenser. <br />kk) The toilet paper dispenser allows for continuous paper flow and does not control delivery. <br />SINGLE ACCOMMODATION TOILET ROOM MINIMUM CLEARANCES <br />1"=1'-0" <br />NOTES: <br />1.REGARDLESS OF STALL CONFIGURATION, <br />A 48" LONG MINIMUM CLEARANCE FLOOR <br />SPACE SHALL BE PROVIDED IN FRONT OF <br />THE WATER CLOSET. <br />2.INTERIOR DIMENSIONS OF SINGLE <br />ACCOMMODATION TOILET ROOMS SHALL <br />INCLUDE A CLEAR FLOOR SPACE OF AT <br />LEAST 60" IN DIAMETER OR A T-SHAPED <br />CLEAR SPACE. NO DOOR MAY ENCROACH <br />INTO THIS REQUIRED SPACE BY MORE <br />THAN 12". <br />FOR WATER CLOSET CLEARANCES, SEE DETAIL <br />FOR LAVATORIES REQUIREMENTS, SEE DETAIL <br />NOTE: SEE PLUMBING PLANS FOR RESTROOM FIXTURES SPECIFICATIONS. <br />B <br />A4.0 <br />C <br />A4.0 <br />TOILET ROOM GRAB BAR DETAIL <br />1 1/2" = 1'-0" <br />1 1/2" <br />@ METAL STUD WALL <br />GRAB BARS LOCATED ON EACH SIDE, <br />OR ONE SIDE AND THE BACK OF THE <br />ACCESSIBLE TOILET STALL OR <br />COMPARTMENT, SHALL BE <br />SECURELY ATTACHED 36 INCHES <br />ABOVE AND PARALLEL TO THE <br />FLOOR TO TOP OF GRIPPING <br />SURFACE, EXCEPT WHERE A <br />TANK-TYPE TOILET IS USED WHICH <br />OBSTRUCTS PLACEMENT AT 33 <br />INCHES, THE GRAB BAR MAY BE AS <br />HIGH AS 36 INCHES. GRAB BARS <br />SHALL BE AT LEAST 42 INCHES LONG <br />WITH THE FRONT END POSITIONED <br />24 INCHES IN FRONT OF THE WATER <br />CLOSET STOOL. GRAB BARS AT THE <br />BACK SHALL BE AT LEAST 36" LONG. <br />GRAB BARS SHALL NOT ROTATE <br />WITHIN THEIR FITTINGS. <br />STUD WALL <br />PER PLAN <br />FINISH FLOOR <br />INTERIOR WALL <br />FINISH SURFACE <br />33 <br />" <br />- <br />3 <br />6 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />ASSESSORIES <br />TYPICAL AT ALL <br />BACKING <br />TOILET ROOM <br />1 1/4" TO 1 1/2" <br />NOMINAL <br />DIAMETER <br />1 1/2" <br />@ WOOD STUD WALL <br />FINISH SURFACE <br />INTERIOR WALL <br />PER PLAN <br />STUD WALL <br />FINISH FLOOR <br />33 <br />" <br />- <br />3 <br />6 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />TYPICAL AT ALL <br />2x6 SOLID BACKING <br />ASSESSORIES <br />TOILET ROOM <br />THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND <br />SHOWER SEATS, FASTENERS, AND MOUNTING DEVICES <br />SHALL MEET THE FOLLOWING SPECIFICATIONS: <br />1.BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY <br />THE MAXIMUM BENDING MOMENT FROM THE <br />APPLICATION OF A 250 POINT LOAD SHALL BE LESS THAN <br />THE ALLOWABLE STRESS FOR THE MATERIAL OF THE <br />GRAB BAR OR SEAT. <br />2.SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY <br />THE APPLICATION OF A 250-POUND POINT LOAD SHALL <br />BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE <br />MATERIAL OF THE GRAB BAR OR SEAT, AND ITS <br />MOUNTING BRACKET OR OTHER SUPPORT IS <br />CONSIDERED TO BE FULLY RESTRAINED THEN DIRECT <br />AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED <br />THE ALLOWABLE SHEAR STRESS. <br />3.SHEAR FORCE INDUCED IN FASTENER OR MOUNTING <br />DEVICES FROM THE APPLICATION OF A 250-POUND <br />POINT LOAD SHALL BE LESS THAN THE ALLOWABLE <br />LATERAL LOAD OF EITHER THE FASTENER OR <br />MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, <br />WHICHEVER HAS THE SMALLER ALLOWABLE LOAD. <br />4.TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT <br />TENSION FORCE OF A 250 POUND POINT LOAD, PLUS THE <br />MAXIMUM MOMENT FROM THE APPLICATION OF A 250 <br />POUND POINT LOAD, SHALL BE LESS THAN THE <br />ALLOWABLE WITHDRAWAL LOAD BETWEEN THE <br />FASTENER AND SUPPORTING STRUCTURE. <br />5.GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br />THE GRAB BAR AND ANY WALL OR OTHER SURFACE <br />ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR <br />ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM <br />RADIUS OF 1/8". <br />1 1/4" TO 1 1/2" <br />NOMINAL <br />DIAMETER <br />E <br />HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44 INCHES ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERATED WITH A SINGLE EFFORT BY LEVER TYPE <br />HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE SIMILARLY, EXCEPT THAT WHEN BOLT AND UNLATCHING OPERATION IS <br />KEY OPERATED FROM CORRIDOR OR EXTERIOR SIDE OF UNIT DOOR, LARGE BOW KEYS (2 INCH) FULL BOW OR 1 1/4 INCH (HALF BOW) SHALL BE PROVIDED IN LIEU OF LEVER TYPE HARDWARE ON THE CORRIDOR SIDE. SEPARATE DEAD LOCK ACTIVATION ON ROOM SIDE OF CORRIDOR DOORS IN <br />EVERY REQUIRED EXIT DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN 6 FEET, 8 INCHES IN HEIGHT. WHEN INSTALLED IN EXIT DOORWAYS, EXIT DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 <br />FOR HINGED DOORS, THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. AT LEAST ONE OF A PAIR OF DOORS SHALL MEET THIS OPENING WIDTH REQUIREMENT. REVOLVING DOORS SHALL NOT BE USED AS A <br />MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLE TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING <br />DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED 15 POUNDS. <br />THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS <br />NO SCALE <br /> ACCESSIBILITY DOOR CLEARANCE REQUIREMENTS <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />PROVIDE THIS ADDITIONAL <br />HOTELS OR MOTELS SHALL HAVE LEVER HANDLE OR LARGE THUMB TURN IN AN EASILY REACHED LOCATION. <br />DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE EXIT WAY IS NOT LESS THAN 32 INCHES. <br />CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR. <br />THRESHOLDS SHALL NOT EXCEED 1/2 INCH IN HEIGHT, WITH 1/4 INCH MAXIMUM VERTICAL CHANGE AT EDGE. MAXIMUM BEVEL ALLOWED IS 45 DEGREES. <br />SPACE IF DOOR IS EQUIPPED W/ <br />TWO HINGED DOORS IN SERIESFRONT APPROACH <br />1. <br />PUSH SIDE <br />3. <br />4. <br />5. <br />6. <br />REQUIRED ENTRANCE FOR THE PHYSICALLY HANDICAPPED. <br />2. <br />TWO HINGED DOORS IN SERIES DOORS AT OPPOSITE WALLS <br />BOTH A LATCH AND A CLOSER <br />48" MIN. <br />18" <br />24" <br />PULL SIDE <br />INTERIOR DOOR <br />EXTERIOR DOOR <br />18 <br />" <br />MI <br />N <br />. <br />MI <br />N <br />. <br />12 <br />" <br />12" <br />ADDITIONAL <br />SPACE IF THE <br />A LATCH AND <br />A CLOSER <br />PROVIDE THIS <br />DOOR HAS BOTH <br />48" MIN.48" MIN. <br />18 <br />" <br />MI <br />N <br />. <br />MI <br />N <br />. <br />18 <br />" <br />12 <br />" <br />MI <br />N <br />. <br />HINGE APPROACH <br />54" MIN. <br />LATCH APPROACH <br />*48" MIN. IF DOOR HAS BOTH <br />A LATCH AND A CLOSER <br />PULL SIDE <br />PUSH SIDE <br />MIN. <br />24"60 <br />" <br /> <br />M <br />I <br />N <br />. <br />PULL SIDE <br />44 <br />" <br /> <br />M <br />I <br />N <br />. <br />* <br />PUSH SIDE <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />MIN. <br />36" <br />44 <br />" <br /> <br />M <br />I <br />N <br />. <br />* <br />NO SCALE <br />WATER CLOSETS CLEARANCES <br />12" <br />MAX. <br />42" MIN. <br />17 <br />" <br /> <br />T <br />O <br /> <br />1 <br />9 <br />" <br />54" MIN. <br />36" MAX. <br />7" TO 9" <br />60" MIN. SIDE LOAD <br />48" MIN. END LOAD <br />24" MIN. <br />33 <br />" <br />- <br /> <br />3 <br />6 <br />" <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br />33 <br />" <br /> <br />M <br />I <br />N <br />. <br />TOILET PAPER <br />HOLDER w/o <br />STOPS <br />PARTITION OR WALL <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br />33 <br />" <br />- <br /> <br />3 <br />6 <br />" <br />12" <br />MIN. <br />24" <br />MIN. <br />36" MIN.6" MAX. <br />17 <br />" <br /> <br />T <br />O <br /> <br />1 <br />9 <br />" <br />17" TO 18"42" <br />MIN. <br />PARTITION OR <br />WALL <br />ACTIVATOR ON <br />WIDE SIDE <br />FINISH SURFACE OF <br />ADJOINING WALL <br />OR PARTITION <br />WALL FINISH PER <br />PLAN & SCHEDULE <br />(F.R.P. TO 48" A.F.F. <br />IN NONE SPECIFIED) <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br />CL <br />CL <br />B <br />NO SCALE <br />LAVATORIES <br />ACCESSIBLE FIXTURES: <br />If lavatories are provided, five percent (5%), or at least one lavatory, shall comply with the following provisions. <br />a) Minimum 30" x 48" clear space is provided in front of lavatory that allows forward approach. <br />b) Required clear space adjoins or overlaps an accessible route and extends a maximum of 19" underneath the lavatory. <br />c) Lavatories adjacent to a sidewall or partition have a minimum 18" distance to the centerline of the fixture. <br />d) 34" maximum height of rim or counter above floor surface. <br />e) 29" minimum clearance from bottom of apron to the floor. <br />f) The accessible lavatory has a minimum 17" of horizontal depth. <br />g) Knee clearance under front lip is a minimum of 27" high, 30" wide, and extends a minimum of 8" in depth from the front of the lavatory. <br />h) Toe clearance under lavatory is a minimum of 9" high, 30" wide, and extends a minimum of 17" in depth from the front of the lavatory. <br />i) The toe clearance is free of equipment or obstructions and extends to a distance no more than 6" from the back wall. <br />j) Drain and hot water piping is insulated or configured to prevent contact. <br />k) There are no sharp or abrasive elements under lavatory. <br />l) Faucets are lever type; push type or electronically controlled mechanisms (preferable). <br /> NOTE: Self-closing valves must maintain a minimum of 10 seconds open flow. <br />m) Faucet controls and operating mechanisms are operable with one hand and do not require tight grasping, pinching or twisting of the wrist. <br />n) 5 Ib. maximum force required to activate controls <br />LAVATORIES REQUIREMENTS & CLEARANCES <br />9" <br />MI <br />N <br />. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />17" <br />MIN. <br />18" <br />MIN. <br />8" MIN. KNEE <br />CLEARANCE6" MAX. TOE <br />CLEARANCE * <br />INSULATE HOT <br />WATER PIPES <br />MIRROR <br />8" <br />27 <br />" <br />11" <br />6" * <br />9" <br />17" <br />*NOTE: IT IS ALLOWED TO HAVE TOE CLEARANCE <br />THAT EXTENDS FURTHER THAN 6" UNDER THE <br />LAVATORY, HOWEVER THE MEASUREMENT OF <br />THE REQUIRED 30"x48" WHEELCHAIR CLEAR <br />FLOOR SPACE MAY ONLY OVERLAP THIS TOE <br />CLEARANCE BY A MAXIMUM OF 6". <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />CL <br />E <br />A <br />R <br />48" MIN. <br />CLEAR <br />19" <br />MAX. <br />18 <br />" <br />MI <br />N <br />. <br />REQUIRED <br />CLEAR SPACE <br />WALL FINISH PER PLAN & <br />SCHEDULE (F.R.P. TO 48" <br />A.F.F. IN NONE SPECIFIED) <br />C <br />SINGLE ACCOMMODATION TOILET ROOM1 <br />60" M <br />I <br />N <br />. <br />CLEA <br />R <br />60" DIAMETER SPACE <br />T-SHAPED SPACE <br />36" <br />MIN. <br />12" <br />MIN. <br />12" <br />MIN. <br />60 <br />" <br />MI <br />N <br />. <br />36 <br />" <br />MI <br />N <br />. <br />SINGLE ACCOMMODATION TOILET ROOM MINIMUM CLEARANCES <br />THRESHOLD AT EXT. DOOR <br />NO SCALE <br />STOREFRONT DOOR <br />ALUM. STOREFRONT BEYOND <br />1:2 BEVELED EDGE <br />EXTERIOR FINISH FLOOR <br />1/2" MAX @ 1:2 SLOPE <br />1/4" MAX <br />NOTE: <br />THRESHOLDS AT DOORWAYS SHALL NOT EXCEED <br />3/4 INCH (19.1 MM) IN HEIGHT FOR SLIDING DOORS <br />SERVING DWELLING UNITS OR 1/2 INCH (12.7 MM) <br />FOR OTHER DOORS. RAISED THRESHOLDS AND <br />FLOOR LEVEL CHANGES GREATER THAN 1/4 INCH <br />(6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH <br />A SLOPE NOT GREATER THAN ONE UNIT VERTICAL <br />IN TWO UNITS HORIZONTAL (50-PERCENT SLOPE). <br />10 <br />" <br /> <br />M <br />I <br />N <br />. <br />G <br />A <br />F <br />EXIT <br />(BRAILLE) <br />TACTILE EGRESS SIGNAGE <br />NO SCALE <br />CIL <br />FINISH FLOOR <br />CIL <br />EXIT SIGNAGE IDENTIFICATION 1/4" ETCHED MAGNESIUM <br />ALLOY WITH RAISED LETTERS AND BRAILLE. PAINTED WITH <br />MATTE PAINT <br />(T <br />Y <br />P <br />. <br /> <br />U <br />. <br />N <br />. <br />O <br />. <br />) <br />NOTE: <br />STYLE & FINISH TO MATCH TENANTS STANDARDS. <br />MIN. (TYP.) <br />60 <br />" <br />5/ <br />8 <br />" <br />5" <br />6" <br />EQ.EQ. <br />1/2" <br />1 <br />3 <br />/ <br />8 <br />" <br />5/ <br />8 <br />" <br />1 <br /> <br />3 <br />/ <br />8 <br />" <br />1" <br />D <br />1/2"=1'-0" <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />12" <br />MAX.42" MIN. <br />54" MIN. <br />6" <br />MA <br />X <br />. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />24" MIN. <br />7' <br />- <br />2 <br />" <br />8'-0" <br /> 1 <br />8 <br />" <br />5'- <br />0 <br />" <br />@ GRAB BAR, <br />TYP. <br />E <br />A4.0 <br />TOILET ROOM SIGNAGE SPECIFICATIONS <br />NO SCALE <br />ALL GENDER <br />RESTROOM <br />12 <br />" <br />6" <br /> <br />M <br />I <br />N <br />. <br />PI <br />C <br />T <br />O <br />G <br />R <br />A <br />M <br /> <br /> <br /> <br />F <br />I <br />E <br />L <br />D <br />SINGLE-USER TOILET FACILITY DOOR & WALL MOUNTED SIGNAGE (TYP.) <br />DOOR MOUNTED SIGNAGE <br />a.A rectangle symbol shall be located at entrances to All Gender’s toilet and bathing facilities. The rectangle <br />symbol shall be 1/4 inch (6.4 mm) thick and 12 inches (305 mm) in height. The color of the rectangle <br />symbol shall contrast with the color of the door or surface on which the rectangle symbol is mounted, either <br />light on a dark background or dark on a light background. <br />b.The geometric symbols are centered horizontally on the door at a height of 58"-60" above the finish floor or <br />ground surface measured to the center of the symbol. <br />c.The edges of the signs are rounded, chamfered or eased, and any corners have a minimum radius of 1/8". <br />WALL MOUNTED SIGNAGE <br />d.The restroom identification signage is located on the wall adjacent to the latch side of the door. <br />e.Pictorial symbol signs (pictograms), if utilized in conjunction with verbal (i.e. text) identification, are located <br />directly above the verbal (i.e. text) description and the border dimension of this pictogram is a minimum of <br />6" in height. <br />f.Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground <br />surface, measured from the baseline of the lowest Braille cells and 60 inches (1524 mm) maximum above <br />the finish floor or ground surface, measured from the baseline of the highest line of raised characters. <br />g.Sign shall be located alongside the door at the latch side. Where there is no wall space at the latch side of a <br />single door or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs <br />containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by <br />18 inches (457 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door <br />swing between the closed position and 45 degree open position. <br />h.Letters and numerals are raised 1/32", are sans-serif uppercase characters and are accompanied by Grade <br />2 Braille. Characters are minimum 5/8" high and a maximum of 2" high. Braille dots are domed or rounded. <br />i.The characters and background of the sign is eggshell, matte, or other non-glare finish and the color and <br />contrast of the sign distinctively contrasts with the color and contrast of the wall. <br />SYMBOL OF ACCESSIBILITY <br />j.Accessible toilet facilities are identified by the International Symbol of Accessibility. The symbol consists of <br />a white figure on a blue background. <br />INACCESSIBLE FACILITIES NOTIFICATION <br />k.Inaccessible sanitary facilities have accessible directional signage that indicates the location of the nearest <br />accessible sanitary facilities. <br />58 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />- <br /> <br />6 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />A. <br />F <br />. <br />F <br />. <br />PROVIDE ADA APPROVED <br />DOOR MOUNTED SIGNAGE <br />PROVIDE ADA APPROVED WALL <br />MOUNTED SIGNAGE TO BE <br />LOCATED ON THE LATCH SIDE OF <br />DOOR CLEAR OF DOOR-SWING. <br />CILALL GENDER <br />RESTROOM <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />A. <br />F <br />. <br />F <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />A. <br />F <br />. <br />F <br />. <br />HEIGHT OF <br />LETTERING 5/8" <br />MIN. TO 2" MAX. <br />3/ <br />8 <br />" <br />MI <br />N <br />3/ <br />8 <br />" <br />- <br />1 <br />/ <br />2 <br />" <br />3/ <br />8 <br />" <br />MI <br />N <br />3/ <br />8 <br />" <br />- <br />1 <br />/ <br />2 <br />" <br />CORRESPONDING <br />GRADE 2 BRAILLE <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />A. <br />F <br />. <br />F <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />A. <br />F <br />. <br />F <br />. <br />5 <br />BUILDING CORRECTIONS 5-7-251 <br />1