Laserfiche WebLink
Nnrrlvc. <br />1. ALL RECEPTACLE OUTLETS SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLE PER GEC <br />406.11 <br />2. OUTDOOR RECEPTACLES SHALL BE LISTED AS <br />WEATHER RESISTANT, PER SEC. 406.9(B) (1 ) <br />3. A MINIMUM OF (1) 20-AMP CIRCUIT FOR <br />BATHROOM(5) OUTLET. SUCH CIRCUIT SHALL <br />HAVE NO OTHER OUTLETS. THI5 CIRCUIT MAY <br />SERVE MORE THAN ONE BATHROOM. GEC, <br />2 10-2 3(A) <br />4. PROVIDE A MINIMUM OF 2 - 20 AMP SMALL <br />APPLIANCE CIRCUITS FOR THE KITCHEN <br />COUNTER TOP5. SUCH CIRCUIT SHALL NO <br />OTHERS OUTLETS. LOADS SHALL BE BALANCED. <br />GEG 2 1 0-52(B) (2) <br />5. PROVIDE A MINIMUM OF 1 - 20 AMP LAUNDRY <br />BRANCH CIRCUIT. SUCH CIRCUIT SHALL HALL NO <br />OTHER OUTLETS. GEC, 2 1 0-25(A) <br />6. ALL 1 20-VOLT, SINGLE PHASE, 15 AND 20 <br />AMPERE BRANCH CIRCUITS IN KITCHEN, FAMILY <br />ROOM5, DINING ROOMS, LIVING ROOMS, <br />PARLORS, LIBRARIES, DENS, BEDROOMS, <br />5UNROOM5, RECREATION ROOMS, CLOSETS, <br />HALLWAYS, LAUNDRY AREAS, OR 51MILAR <br />ROOMS OR AREAS SHALL BE PROTECTED BY A <br />L15TED ARC -FAULT CIRCUIT INTERRUPTER, <br />COMBINATION -TYPE. (GEG 2 10.1 2.) LIGHTS, <br />OUTLETS, SD, GM, ETC. <br />XTnrripc. <br />1. ALL INSTALLED LUMINAIRE MUST BE <br />HIGH EFFICACY IN ACCORDANCE WITH <br />TABLE 150.0-A. <br />2. EXHAUST FANS MUST BE SWITCHED <br />SEPARATELY FROM LIGHTING <br />SYSTEMS. <br />3. IN BATHROOMS, GARAGES, LAUNDRY <br />ROOMS, AND UTILITY ROOMS, AT <br />LEAST ONE LUMINAIRE IN EACH OF <br />THESE SPACES MUST BE <br />CONTROLLED BY A VACANCY <br />SENSOR. <br />4. OUTDOOR LIGHTING PERMANENTLY <br />MOUNTED TO A RESIDENTIAL <br />BUILDING, OR TO OTHER BUILDING ON <br />THE SAME LOT, MUST MEET THE <br />REQUIREMENT IN ITEM § 1 50.0(K)3Ai <br />(ON AND OFF SWITCH) AND THE <br />REQUIREMENTS IN EITHER ITEM § <br />1 50.0(K)3AH (PHOTOCELL AND <br />MOTION SENSOR) OR ITEM § <br />1 50.O(K)3Aiii (PHOTO CONTROL AND <br />AUTOMATIC, TIME 5WITGH CONTROL, <br />ASTRONOMICAL TIME CLOCK, OR <br />EMG5). <br />ELECTRICAL NOTES: <br />T <br />AFGI <br />/*AFGI AFGI <br />FL FL <br />AFGI <br />CFI I (N) BEDROOM # 1 <br />(E) 8'-0" GL. HT. (N) SD <br />�p-EA <br />GI / AFGI <br />FLFL <br />AFGI <br />GFGI <br />42+ . <br />\ SOS <br />0 <br />FGI <br />OAFCI <br />D + AFL <br />(N) <br />GO GFGI <br />1 8+t <br />I GFGI <br />2 X L I <br />GFGI AFGI I A�T-CC w 2 \ <br />(FOR AIR <br />HANDLER) <br />(N) LIVING ROOM <br />I <br />AA AFGI (E) 6-0" CL. H j} W kD <br />{ }0 <br />AFGI i ,� <br />5-2 ` FLU - - CI - - AFGI In <br />FLZ <br />\ FL w <br />EXHAUST \ O O <br />FAN AF1� \ AFGI m "* <br />50 GFM <br />1 ) ALL BRANCH CIRCUITS THAT SUPPLY ALL 1 20-VOLT, SINGLE PHASE, 15 <br />AND 20 AMPERE BRANCH CIRCUITS OUTLETS INSTALLED IN DWELLING <br />UNIT SHALL BE PROTECTED BY AN ARC, -FAULT CIRCUIT <br />INTERRUPTER(5). (GEG 2 10.12). FOR ENTIRE CIRCUIT, NOT JUST THE <br />OUTLETS. <br />2) PROVIDE A 20 AMP GFGI PROTECTED ELECTRICAL OUTLET WITHIN 56" <br />OF THE OUTSIDE EDGE OF EACH BATHROOM SINK BASIN. OUTLET <br />SHALL BE LOCATED ON A WALL OR PARTITION THAT 15 ADJACENT TO <br />THE BASIN OR INSTALLED ON THE SIDE OR FACE OF THE BASIN <br />CABINET NOT MORE THAN 1 2" BELOW THE COUNTERTOP. <br />5) RECEPTACLES SHALL BE LISTED AND LABELED AS <br />TAMPER -RESISTANT. <br />4) A MINIMUM OF (1) 20 AMP CIRCUIT 15 REQUIRED FOR BATHROOMS. SUCH <br />CIRCUITS SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE <br />MORE THAN ONE BATHROOM. GEG 2 1 0.52(D) <br />5) NO PENDANT LIGHT FIXTURES IN ZONE 5' AWAY AND V ABOVE THE <br />BATHTUB OR SHOWER. <br />6) LUMINARIES LOCATED WITHIN THE ACTUAL OUTSIDE DIMENSIONS OF THE <br />TUB OR SHOWER, UP TO 5 FEET VERTICALLY FROM THE TOP OF THE <br />BATHTUB RIM OR SHOWER THRESHOLD, SHALL BE MARKED AS <br />SUITABLE FOR DAMP LOCATIONS, PROVIDED WITH A SOLID LENS AND <br />BE GFGI PROTECTED. <br />7) BATHROOM LIGHTING SHALL BE HIGH EFFICACY LUMINARIES (40 <br />LUMENS PER WATT) OR CONTROLLED BY A VACANCY (OCCUPANCY) <br />SENSOR CERTIFIED TO COMPLY WITH SEC 1 1 9(D) GEES. THIS 15 A <br />MANUAL ON, AUTO OFF DEVICE. <br />5) AUTOMATIC ON OR DEVICES WITH AN OVERRIDE 5WITGH P051TION ARE <br />NOT APPROVED. HIGH EFFICACY, INCANDESCENT LIGHTING OR FANS <br />ARE REQUIRED TO BE SWITCHED SEPARATELY. <br />9) RECESSED LUMINARIES INSTALLED IN AN INSULATED CEILING SHALL BE <br />IC, RATED (ZERO CLEARANCE) AND AT RATED (AIRTIGHT) AND SHALL <br />BE SEALED AND/OR GASKET BETWEEN CEILING AND HOUSING. <br />1 0) FOR OCCUPANCIES WITH A HORIZONTAL (FLOOR/CEILING ASSEMBLY) <br />RATED SEPARATION, THE RECESSED FIXTURES SHALL BE PROTECTED <br />TO THE RATING OF THE SEPARATION (1 HOUR) OR BE LISTED FOR THE <br />REQUIRED PROTECTION. THIS GENERALLY APPLIES TO RESIDENTIAL <br />CONDOMINIUM CONSTRUCTION WHERE UNITS ARE ABOVE OR BELOW <br />OTHER UNITS. <br />1 1) ALL RECEPTACLES LISTED IN SECTION 2 1 0-52 SHALL BE L15TED AS <br />TAMPER -RESISTANT FOR ALL 15 AND 20 AMPERE RECEPTACLES IN <br />DWELLING UNIT FAMILY, DINING, LIVING, PARLORS, LIBRARIES, DENS, <br />BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, <br />OR 51MILAR ROOMS AND AREAS PER GEG SEC 406.12 <br />FL <br />WEATHERPROOF PHOTO <br />IN/ PLUG GAP CONTROL <br />GFGI/ <br />wP NOTE - HARD WIRED SMOKE <br />DETECTORS [CRC R314] : <br />A MINIMUM OF 20 FT. FROM PERMANENT COOKING <br />EQUIPMENT (OR 10 FT. WITH PHOTO -ELECTRIC <br />TYPE. <br />LEGEND <br />TITLE 24 - 2ND UNIT NOTES: WHOLE -BUILDING VENTILATION RATE j EXISTING WALL TO REMAIN <br />HVAG EQUIPMENT: MINI SPLIT HP SUMMARY: NEW WALL <br />HEATING ENTER THE REQUIRED FAN FLOW RATE (GFM): <br />EFF. TYPE: HSPF <br />HSPF / GOP: 5.7 ■ CONTINUOUS FAN FLOW (GFM) = 407 / 100 + -7.5 (1 + 1) = 20 GFM <br />GAP 47: 12000 (USE 50 GFM) ELECTRICAL LEGEND <br />GAP 1 7: 7 500 <br />COOLING ■ USE THE FAN FLOW RATE FROM THIS SUMMARY FOR SELECTION OF <br />EFF. TYPE: EER5EER THE WHOLE -BUILDING VENTILATION FAN AND FOR THE DUCT DESIGN AMP PANEL (PER PLANS) <br />SEER / 5EER2: 20 FOR THE WHOLE -BUILDING VENTILATION SYSTEM FROM TABLE 7.1. <br />THERMOSTAT - SETBACK I G- IRRIGATION CONTROLLER <br />HEATING $ COOLING I5 DUCTED ■ DUGT 51ZE (IN) = 5" (V DUCT 51ZE ® (WEATHER OR 501L M015TURE BASED) <br />DUCT LOCATION - ATTIC DUPLEX ELEC. OUTLET (1 1 OV) <br />CEILING INSULATION VENTED MAXIMUM ALLOWABLE DUCT LENGTH (FT.) = 1 00'MAX <br />WATER HEATER: DOMESTIC HOT WATER (DHW) THE SWITCH OPERATING THE EXHAUST FAN SHALL HAVE A LABEL =AFGI GROUND FAULT INTERUPTED CIRCUIT <br />NATURAL GA5 STATING: DUPLEX OUTLET (1 20V IN/ <br />ENERGY FACTOR: 0.95 EFF. "OPERATE WHEN HOUSE 15 IN USE" OR/ GFGI <br />200,000 BTU/HR "FAN 15 TO BE LEFT ON TO ENSURE INDOOR AIR QUALITY" OR/ GROUND FAULT INTERRUPTER) <br />KITCHEN PIPE INSULATION "KEEP ON EXCEPT WHEN GONE OVER 7 DAYS" GFGI/DUPLEX OUTLET (1 20V WEATHER <br />pNp RESISTANT OUTLET, (5FI) <br />DUCT INSULATION VALUES: R-6 EXHAUST FAN SHALL HAVE A SOUND RATING OF 1 50NE OR LE55 WP WATER PROOF <br />FAN SPECIFICATIONS: H t <br />MANUFACTURE PANASONIC - WHISPER GREEN 50 GFM H05E BIBS W/ ANTI-51PHONE <br />WALL MOUNTED LIGHT (FL) <br />MODEL: FV-OS- 1 1 VKL 1 <br />CEILING MOUNTED LIGHT (AFGI - FL) <br />6" RECESS LIGHT (AFGI - FL) -- HIGH EFFICACY <br />CEILING FAN W/ LIGHT (AFGI - FL) <br />SINGLE POLE SWITCH <br />2 EXHAUST FAN (1 00 GFM) TO OUTSIDE <br />ENERGY STAR RATED $ HUMID15TAT CONTROLLED <br />LIGHT & EXHAUST FAN COMBO <br />FL FLUORESCENT LIGHT BULB FIXTURE _ (PIN BASE + <br />CERTIFIED TO <br />D DIMMER SWITCH THE ENERGY <br />I GOMMI5510N) <br />+05 OCCUPANT SENSORS <br />+3 3-WAY SWITCH <br />W SMOKE DETECTOR BATTERY <br />Q I ®5D (INTER -CONNECTED) <br />vo <br />z CARBON MONOXIDE DETECTORS <br />®GO (GRG R3 1 5) SECTIONS R315.1 & R3 15.2 <br />WEATHERPROOF DATA COMMUNICATIONS OUTLET <br />W/ PLUG GAP <br />GFGI/ (INDICATE NONSTANDARD MOUNTING HT.) <br />WP <br />TELEPHONE OUTLET <br />1 (INDICATE NONSTANDARD MOUNTING HT.) <br />(N) TANKLE55 NOTES: <br />D 1 <br />WH TELEVISION OUTLET <br />�.; A ® (N) TANKLE55 WH 1 9 9,900 BTU (4'-0" MIN. TV (INDICATE NONSTANDARD MOUNTING HT.) <br />it SEPARATE FROM WH VENT TO WINDOWS.) <br />a NOT PROVIDE SHALL VENT THRU ROOF. 2X4 LIGHTS - FLUORESCENT TUBE <br />(CMG 802.8) <br />MO5 MANUAL -ON OCCUPANCY SENSOR (1) IONIZATION <br />MANUFACTURE: RHEEM <br />MODEL: ECOH2O0XLN- 1 (OUTDOOR) H H = HUMID15TAT CONTROLLED VS VACANCY <br />ENERGY FACTOR: OA 3 SENSOR <br />�I GAS: NATURAL ELECTRICAL NOTES: <br />- - AA <br />5-2 <br />NOTE: <br />PROVIDE AN EXHAUST <br />RATE OF 250 GFM <br />FAN IN THE KITCHEN <br />GFGI HOOD OVER ELECTRIC <br />RANGE: _ <br />IRAN67F: <br />% GE OR 1 60 GFM <br />OD OVER NATURAL GA5 <br />% GE OR 250 GFM <br />(E) MAIN FRONT HOUSE - <br />TO REMAIN - NO CHANGE) <br />(E) AG <br />(E) 24X36 FLR CONDENSER <br />ACCESS A (N) TANKLE55 RELOCATE (N) <br />(GRG R405.4) WH <br />(E) AMP <br />PANEL X <br />I� lil i I <br />�Ll <br />(E) BATH #2 (E) BEDROOM #3 <br />_ (E) 6-0" CL. HT. (I-) V-O" CL. HT. <br />1[�DI I <br />rz U <br />W w o0 w <br />.c <br />[GARAGE CONVERT INTO ADU UNIT] <br />ELECTRICAL PLAN <br />SCALE: 1 /4" = 1'-0" <br />CITY OF SANTA ANA <br />PI nni ilding A ency <br />z N UEN <br />v C7i ::GN + ASSOCIATES <br />FO 'i-GI�❑VE,•CAV <br />E CE <br />TEL: (714) 4613-71 63 <br />WEBSITE: WWW,WIX.COM/ <br />NGUYENADESIGN/ANTHONY <br />THE DRAWINGS, IDEAS, <br />Ma <br />St <br />ARGEMENTS <br />AND <br />I I[ ATI❑NS CONTAINED IN <br />H <br />E.D❑CUMENTS ARE THE <br />Dale, <br />PROPERTY AND COPYRIGHT OF <br />NGUYEN DESIGN + ASSOCIATES <br />AND SHALL NOT BE USED ON <br />ANY OTHER WORK EXCEPT BY <br />AGREEMENT WITH NGUYEN <br />DESIGN + ASSOCIATES. <br />WRITTEN DIMENSIONS SHALL <br />TAKE PREFERENCE OVER SCALED <br />DIMENSIONS AND SHALL BE <br />VERIFIED ON THE JOB SITE. <br />ANY DISCREPANCY SHALL BE <br />BROUGHT TO THE NOTICE OF <br />NGUYEN DESIGN + ASSOCIATES. <br />PRIOR TO THE COMMENCEMENT <br />OF ANY WORK. <br />1. PROVIDE APPROVED SMOKE ALARMS, SMOKE ALARMS SHALL BE <br />INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL <br />ACTIVATE ALL ALARMS. <br />2. SMOKE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED <br />WITH BATTERY BACK-UP @ ALL NEW BEDROOMS. <br />3. BATTERY OPERATED SMOKE DETECTOR PERMITTED IN EXISTING <br />CONSTRUCTION. <br />4. FOR SINGLE-FAMILY DWELLINGS AND DUPLEXES ARE NOT CHECKED <br />FOR PLUMBING, MECHANICAL AND ELECTRICAL CODE COMPLIANCE. <br />THESE DISCIPLINES ARE SUBJECT TO FIELD INSPECTION. <br />5. THE RESIDENCE SHALL CONFORM TO THE STATE ENERGY STANDARDS. <br />6. WALLS 2 FT. OR GREATER SHALL HAVE AN OUTLET. OUTLETS SHALL BE <br />SPACED MAX. 1.2 FT. APART, AND A MAXIMUM OF 6 FT. FROM END OF <br />WALL5 OR OPENING (GEC 2 1 0-52A) <br />7. ALL RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTAND <br />RECEPTACLE PER GEG 406.1 1. <br />5. BATHROOM RECEPTACLES SHALL BE SERVED BY A DEDICATED 20 <br />AMP CIRCUIT PER GEG 2 1 0-52(D). <br />ENERGY LIGHTING <br />A. KITCHENS. AT LEAST HALF THE INSTALLED WATTAGE OF LUMINARIES IN <br />KITCHENS SHALL BE HIGH EFFICACY AND THE ONES THAT ARE NOT MUST <br />BE SWITCHED SEPARATELY. <br />B. LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY <br />ROOMS. ALL LUMINARIES SHALL EITHER BE HIGH EFFICACY OR SHALL BE <br />CONTROLLED BY AN OCCUPANT SENSOR. <br />C. OTHER ROOMS. ALL LUMINARIES SHALL EITHER BE HIGH EFFICACY OR <br />SHALL BE CONTROLLED BY AN OCCUPANT 5EN50R OR DIMMER. <br />CLOSETS THAT ARE LESS THAN 70 SQUARE FOOT ARE EXEMPT FROM <br />THI5 REQUIREMENT. <br />FOR ALTERATIONS, REPAIRS AND ADDITIONS OF EXISTING DWELLINGS <br />EXCEEDING $ 1,000 CARBON MONOXIDE ALARMS ARE REQUIRED IN THE <br />SPECIFIC PERMITTED DWELLINGS OR SLEEPING UNITS THAT HAVE <br />ATTACHED GARAGES OR FUEL -BURNING APPLIANCES. THE CARBON <br />MONOXIDE ALARMS MAY BE BATTERY OPERATED AND NOT <br />INTERCONNECTED. (CRC R3 1 4.5.1 ) <br />- ALARMS WILL BE BATTERY OPERATED. <br />- ALARMS SHALL BE LOCATED OUTSIDE OF EACH SEPARATE DWELLING <br />UNIT SLEEPING AREA NEAR THE BEDROOMS) AND ON EVERY LEVEL <br />INCLUDING BASEMENTS. (GRG R315.3) <br />- LISTING $ APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHAL <br />FOR COMBINED CARBON MONOXIDE & SMOKE ALARMS ARE ALLOWED. <br />ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS, <br />OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS <br />OF $ 1,000, AN APPROVED CARBON MONOXIDE ALARM SHALL BE <br />INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH <br />FUEL -BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT <br />HAVE ATTACHED GARAGES SHALL BE PROVIDED WITH CARBON <br />MONOXIDE ALARMS (CRC R3 1 5) <br />- CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE <br />5PEGIFIG DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WA5 <br />OBTAINED. CARBON MONOXIDE ALARMS REQUIRED BY SECTIONS <br />(CRC, R3 15.1 AND R5 1 5.2) SHALL BE INSTALLED. UL 2034/2075 <br />-IN NEW BUILDING, CARBON MONOXIDE ALAM5 SHALL BE <br />INTERCONNECTED AND HARDWIRED. (CRC R3 15.1 AND R3 15.2) <br />- ALARMS SHALL BE LOCATED OUTSIDE OF EACH SEPARATE DWELLING <br />UNIT SLEEPING AREA NEAR THE BEDROOM(5) AND ON EVERY LEVEL <br />INCLUDING BASEMENTS. (CRC R3 15.3) <br />- WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO <br />BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT <br />THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT <br />ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN <br />THE INDIVIDUAL UNIT. <br />EXCEPTION: <br />INTERCONNECTION 15 NOT REQUIRED IN EXISTING DWELLING UNITS WHERE <br />REPAIRS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED, <br />THERE 15 NO ACCESS BY MEANS OF ATTIC, BASEMENT OR GRAWL SPACE, <br />AND NO PREVIOUS METHOD FOR INTERCONNECTION EXISTED. <br />QROF E^SS ,, <br />IOAn <br />G/ c <br />j9/01 /2025 <br />CONSULTANT: <br />F� <br />W " <br />UO�� <br />z W <br />L7A�oT <br />Z��z� <br />dw�Lu <br />� Z �Lu <br />O ` <br />v <br />ELECTRICAL <br />PLAN <br />DRAYNING TITLE: <br />PLAN CHECK: <br />PLAN GHEGK# 1 01 123252 <br />C56# 4504613 <br />REV151ON5: <br />DATE <br />Z1 <br />OS- 1 1 -2025 <br />0 <br />09-0 1 -2025 <br />DRAWN BY: ANTHONY NGUYEN <br />5GALE: <br />AS NOTED <br />DATE: <br />09-0 1 -2025 <br />PROJECT NO: <br />N2403 1 03 <br />SHEET NO. 07 OF <br />15 SHEETS <br />