UNIFORM AND POINT LOAD ON CONTINUOUS FOOTING <br />Footing Width (FW) = <br />Footing Depth (FD) = <br />Soil Bearing (SB) = <br />Max. Soil Bearing = <br />Plain Concrete Design : <br />F'c = <br />Tension Fb = <br />Procedures : <br />12 in <br />12 in <br />1,500 psf <br />1,500 psf <br />2 ,500 psi <br />80 psi <br />Fsoil = ((D-FD)/12*1D)+SB <br />F'soil = Fsoii-(D/12*(150-11 0)) <br />w = W*F'soil/12 <br />W(") <br />12 X <br />12 X <br />15 X <br />18 X <br />21 X <br />24 X <br />12 X <br />15 X <br />18 X <br />21 X <br />24 X <br />12 X <br />15 X <br />18 X <br />21 X <br />24 X <br />12 X <br />15 X <br />18 X <br />21 X <br />24 X <br />12 X <br />15 X <br />18 X <br />21 X <br />24 X <br />30 X <br />M = Fb*W*d"2/12"/6 <br />L = (2*M/w)"1/2 <br />Pmax = 2*L*w <br />D (") Fsoil (psf) F'soil (psf) <br />5 1,500 1,483 <br />12 1,500 1,460 <br />12 1,500 1,460 <br />12 1,500 1,460 <br />12 1,500 1,460 <br />12 1,500 1,460 <br />15 1,500 1,450 <br />15 1,500 1,450 <br />15 1,500 1,450 <br />15 1,500 1,450 <br />15 1,500 1,450 <br />18 1,500 1,440 <br />18 1,500 1,440 <br />18 1 ,500 1,440 <br />18 1 ,500 1,440 <br />18 1 ,500 1,440 <br />21 1,500 1,430 <br />21 1,500 1,430 <br />21 1,500 1,430 <br />21 1,500 1,430 <br />21 1,500 1,430 <br />24 1,500 1,420 <br />24 1,500 1,420 <br />24 1,500 1,420 <br />24 1,500 1,420 <br />24 1,500 1,420 <br />24 1 ,500 1,420 <br />Soil Density = <br />Concrete Density = <br />Inc. Width (IW) = <br />Inc. Depth (ID) = <br />w {#/ft} M ('#) <br />1,483 333 <br />1,460 1,920 <br />1,825 2,400 <br />2 ,190 2 ,880 <br />2 ,555 3,360 <br />2 ,920 3,840 <br />1,450 3 ,000 <br />1,813 3 ,750 <br />2,175 4 ,500 <br />2 ,538 5 ,250 <br />2 ,900 6 ,000 <br />1,440 4 ,320 <br />1,800 5,400 <br />2 ,160 6,480 <br />2,520 7,560 <br />2 ,880 8,640 <br />1,430 5 ,880 <br />1,788 7 ,350 <br />2 ,145 8 ,820 <br />2 ,503 10,290 <br />2 ,860 11,760 <br />1 ,420 7 ,680 <br />1,775 9,600 <br />2 ,130 11 ,520 <br />2,485 13,440 <br />2 ,840 15,360 <br />3 ,550 19,200 <br />110 pcf <br />150 pcf <br />0 psf <br />0 psf <br />L (ft) Pmax {#} <br />0.67 1,989 <br />1.62 4 ,736 <br />1.62 5 ,919 <br />1.62 7 ,103 <br />1.62 8 ,287 <br />1 .62 9 ,471 <br />2 .03 5 ,899 <br />2 .03 7 ,374 <br />2 .03 8 ,849 <br />2 .03 10 ,324 <br />2.03 11 ,798 <br />2.45 7 ,055 <br />2.45 8,818 <br />2.45 10 ,582 <br />2.45 12 ,345 <br />2 .45 14,109 <br />2 .87 8 ,202 <br />2 .87 10,252 <br />2.87 12 ,302 <br />2.87 14,353 <br />2.87 16,403 <br />3.29 9,340 <br />3 .29 11 ,676 <br />3.29 14 ,011 <br />3 .29 16,346 <br />3 .29 18 ,681 <br />3 .29 23 ,351 <br />Note : For point loads on footings with uniform loads , take the difference <br />between "w" above and the uniform load , then multiply by two and by <br />"L" above for P'max .