My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2314 N Larchmont Ave #2 - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Larchmont Ave
>
2314 N Larchmont Ave Unit# 2
>
2314 N Larchmont Ave #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:54 AM
Creation date
2/13/2026 5:00:55 AM
Metadata
Fields
Template:
Plan
Permit Number
101121195
Full Address
2314 N Larchmont Ave Unit# 2
Street Number
2314
Street Direction
N
Street Name
Larchmont
Street Suffix
Ave
Unit Number
2
Document Relationships
101121195 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Larchmont Ave\2314 N Larchmont Ave Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2022 Single -Family Residential Mandatory Requirements <br />CITY OF SANTA ANA <br />?nning and Building Agency <br />Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use u4 fo��ypXu 0A C E <br />a hole for the placement of a static pressure probe, or a permanently installed static pressure probe i th sa(i�y I o <br />§ 150.0(m)13: be >_ 350 CFM per ton of nominal cooling capacity, and an air -handling unit fan efficacy 5 0.45 watts r CFM for gas furnace air <br />handlers ands 0.58 watts per CFM for all others. Small duct high velocity systems must provide an ai flow z 250 CFM per ton of nominal <br />cooling capacity, and an air -handling unit fan efficacy 5 0.62 watts per CFM. Field verification testing F0iiq fcordance with <br />Reference Residential ADDendix RA3.3. * <br />�611111PPV11 PIIV 11 <br />Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, <br />§ 150.0(o)l: <br />Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * <br />Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- <br />§ 150.0(o)1 B: <br />dwelling unit ventilation airflow required per §150.0(o)1 C. A motorized damper(s) must be installed on the ventilation duct(s) that <br />prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)l Biii&iv. CFI <br />ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for <br />compliance with §150.0 0 1C. <br />Whole -Dwelling Unit Mechanical Ventilation for Single -Family Detached and townhouses . Single-family detached dwelling units, <br />§ 150.0(o)lC: <br />and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial <br />spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. <br />§ 150.0(o)1G: <br />Local Mechanical Exhaust Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand - <br />controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand -controlled or <br />continuous exhaust meeting §150.0(o)1 Giii-iv. Airflow must be measured by the installer per §150.0(o)1 Gv, and rated for sound per <br />150.0 0 1 Gvi. * <br />§ 150.0(o)lH&I: <br />Airflow Measurement and Sound Ratings of Whole -Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must <br />be measured by using a flow hood, flow grid, or other airflow measuring device at the fan's inlet or outlet terminalslgriIles per Reference <br />Residential Appendix RA3.7. Whole -Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the <br />minimum airflow rate required by §150.0 0 1C. <br />Field Verification and Diagnostic Testing. Whole -Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, <br />§ 150.0(o)2: <br />and HRV and ERV fan efficacy must be verged in accordance with Reference Residential Appendix RA3.7. Vented range hoods <br />must be verged per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow <br />rates and sound requirements per §150.0(o)l G <br />r VVI PIIV V <br />Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance <br />§ 110.4(a): <br />with the Appliance Efficiency Regulations and listing in MAEDbS; an on -off switch mounted outside of the heater that allows shutting off <br />the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not <br />use electric resistance heating. * <br />Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or <br />§ 110.4(b)l: <br />dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. <br />§ 110.4(b)2: <br />Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. <br />Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time <br />§ 110.4(b)3: <br />switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. <br />§ 110.5: <br />Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. <br />Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump <br />§ 150.0(p): <br />sizing, flow rate, piping, filters, and valves. <br />LI II1111 <br />Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable <br />§ 110.9: <br />requirements of § 110.9. * <br />§ 150.0(k)1A: <br />Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaustfans, kitchen <br />range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen <br />closets with an efficacy of at least 45 lumens per watt. <br />§ 150.0(k)1B: <br />Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. <br />Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, <br />§ 150.0(k)1C: <br />and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. <br />Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 <br />§ 150.0(k)1D: <br />elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. <br />Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a <br />§ 150.0(k)1E: <br />luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor <br />control, low voltage wiring, or fan speed control. <br />Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust <br />§ 150.0(k)1F: <br />hoods) must meet the applicable requirements of § 150.0(k). <br />5/6/22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.