CITY OF SANTA ANC <br />v_K: <br />racy i <br />GENERAL: <br />1. <br />2. <br />3. <br />4. <br />5. <br />CONSTRUCTION NOTES: <br />All work performed shall be in accordance with the 2022 California <br />Building Code. <br />Where no specific detail, section or indication is given, typical or <br />approved standard practice details are to be used. <br />The contractor shall verify all dimensions shown on plans and <br />existing field conditions. In case of any discrepancies, the <br />engineer shall be contacted before proceeding with the work. <br />The contractor shall coordinate all structural work with the <br />architectural, mechanical, plumbing, and any other related drawings <br />and notifies the engineer of any discrepancies. <br />Contractor shall verify location and size of floor, roof and wall <br />openings with other drawings. Openings not shown on structural <br />drawings are not permitted. <br />FOUNDATION: <br />1. All site recommendations related to grading and foundations were <br />assumed using code minimums at the absence of a soils report. <br />2. All exterior continuous footings shall extend into firm natural soil or <br />approved compacted fill a minimum of 24". <br />3. All interior footings shall extend into firm natural soil or approved <br />compacted fill a minimum of 18". <br />M <br />5 <br />0 <br />7 <br />I <br />Q <br />10 <br />Garage slab should be poured separately from the residence footings. <br />A positive separation should be maintained with expansion joint materials <br />to permit relative movement (WHERE APPLIES). <br />All trench excavations should conform to CAL -OSHA and local safety <br />codes. All utilities trench backfill should be brought to near optimum <br />moisture content and then compacted to obtain a minimum relative <br />compaction of 90 percent of ASTM D-1 557-91 . <br />Excavations adjacent to existing buildings or walls shall not extend <br />below an angle of 45 degrees from the bottom of the footings of <br />these adjacent structures, or the contractor shall provide adequate <br />shoring for the excavations. <br />Where existing footings, concrete slabs, pipes, utilities or other buried <br />items are removed, the disturbed (loose) soil shall be removed and <br />recompacted to a minimum of 90% of maximum density. <br />All fills shall be compacted to a minimum of 90% of maximum density <br />in accordance with ASTM D-1 557-91 . Fill shall be placed under the <br />supervision of, tested and certified by, an approved soils engineer. <br />The soil engineer shall inspect all excavations, removal of superficial and <br />unsuitable soils, and utility trench backfill. <br />All residential foundation shall be setback from the descending slope <br />surface a minimum horizontal distance of H/3 but need not exceed 40 <br />f eet. <br />All new footing shall be 24" min. embedment and bellow adjacent <br />lower grade for without soil report. <br />CONCRETE: <br />1. All concrete shall be made with stone aggregate and shall attain <br />a minimum compressive strength at 28 days of 2500 psi. The <br />type V cement, 0.45 water cement ratio without soil report. <br />Maximum concrete slump shall be 3" - 4". <br />2. Special inspection by a certified inspector shall be provided for <br />structural concrete when the structural design is based on f'c in <br />excess of 2500 psi. <br />3. Cement for concrete. Mortar, and grout shall be Type V <br />conforming to ASTM C-150. Aggregates shall conform to ASTM C-33 <br />and shall not exceed 1 " in size. <br />4. The engineer shall approve location of all construction joints. <br />5. No pipes or ducts, other than conduits, shall be placed in structural <br />concrete unless specifically shown on plans. Aluminum conduit shall not <br />be used. <br />6. Drypack shall be 1:3 cement sand mix. <br />STRUCTURAL AND MISCELLANEOUS STEEL: <br />1. All detailing, erection, and fabrication shall conform to the <br />latest edition of AISC specifications. <br />2. Welding electrode shall be AWS E70XX or equal. Welding to <br />be <br />designed for half stresses. Non -continuous inspection by a <br />Deputy <br />Inspector is required. <br />3. All welding processes and inspection procedures shall conform <br />to <br />the American Welding Society Specification D1.0 latest edition. <br />Welding shall be performed by City of Los Angeles certified <br />welders <br />in a shop of an approved fabricator. All field welding shall <br />be <br />performed under continuous inspection or a Special Deputy <br />Inspector <br />approved by local building Department. <br />4. Steel fabricator shall submit shop drawings to the engineer <br />for <br />review prior to fabrication. <br />5. A certificate of fabrication from the fabricating shop or a <br />report from the special inspector must be furnished to the <br />local <br />Building Department prior to framing approval. <br />WOOD FRAMING: <br />1. Framing lumber shall be Douglas Fir -Larch, grade marked by <br />W.W. P.A. or W.C.L.I.B. as follows, unless noted on plans: <br />Vertical Framing <br />2" x 4" Standard Grade or Better <br />2" x 6" and Larger No. 2 Grade or Better <br />4" x 4" and Larger No. 1 Grade or Better <br />HORIZONTAL FRAMING: <br />a <br />3 <br />:1 <br />I <br />N <br />7. <br />K <br />10 <br />12 <br />13 <br />7. All anchor bolts, dowels and other inserts shall be placed before pouring14 <br />concrete. <br />REINFORCING STEEL: <br />2. <br />3. <br />N <br />5 <br />All detailing, erection, and fabrication of reinforcing and accessories sha1115 <br />conform to the Manual of Standard Practice of the Concrete Reinforcing <br />Steel Institute. <br />Reinforcing steel shall conform to ASTM A-615, Grade 60. <br />Reinforcing shown continuous shall be lapped 40 bar diameters 16 <br />(24" minimum) in concrete, unless noted otherwise. <br />Reinforcing shall have the following minimum cover: <br />Concrete poured against earth 3-inch 17 <br />Formed concrete -exterior face 2-inch <br />Welded wire mesh shall conform to ASTM A-1 85. Lap one full mesh 18 <br />plus 2" at splice. <br />2" x & 4" x No. 2 Grade or Better. <br />6" x and Larger No. 1 Grade or Better <br />Plywood roof and floor sheathing shall be as noted on plans. <br />Plywood for shear walls shall be a minimum Structural II. All sheets <br />shall conform to PS-1 -09 and shall be bonded with exterior glue. <br />Each plywood sheet shall have a minimum area of 8 square feet <br />and a minimum dimension of 2 feet in any direction. Plywood shall be <br />installed with joints staggered in adjacent sheets, with each sheet <br />continuous over 2 or more supports and the face grain <br />perpendicular to supports for floor and roof sheathing, and <br />parallel to supports for wall sheathing. <br />All nails shall be common wire nails with minimum nailing per Table <br />R602.3(1) of the California Residential Code, unless shown otherwise. <br />All framing hardware shown are strong -Tie Connectors as <br />manufactured by the Simpson Company, unless noted otherwise. All <br />hardware to be installed per manufacturer's recommendations. <br />Bolts shall conform to ASTM A-307. Provide washers under all <br />bolts, nuts, and screw heads. <br />Provide double joists under all parallel walls and solid blocking <br />under walls perpendicular to floor joists. <br />Anchor bolts shall be 5/8" in diameter by 10"long with 3"x3"x1/4" MIN. <br />washers embedded 7" minimum into concrete or masonry, unless <br />noted otherwise on plans. See shear wall schedule and plans for <br />spacing. Install a minimum of 2 bolts in each piece of pressure <br />treated sill plate, with the first bolt within 12" of the end of the <br />plate. <br />Joists or rafters framing from opposite sides of beams or walls <br />shall be lapped a minimum of 4" and spliced with 4-16d nails, unless <br />noted otherwise on plans. <br />Beams built-up with more than 2-2% members shall have all <br />pieces full length and shall have 1/2" bolts at 18" O.C. staggered <br />top and bottom 3" from the edges, with the first bolt 3-1/2" from <br />the end. <br />All flush framed 2% connections shall be made with Simpson "LUP" <br />series hangers, unless noted otherwise on the plans. <br />All flush framed 2% and larger connections shall be made with <br />Simpson "B" series hangers, unless noted otherwise on the plans. <br />Lap all 2x top plates a minimum of 4'-0" at splices and nail with <br />10-16d on each side of each splice, unless noted otherwise on the <br />plans. Where top or sill plates are cut, use a 1 /8" x 1-1/2" metal <br />strap with 10-16d on each side of cut. <br />Studs may be cut or notched to a maximum depth of 25% of the <br />width. Bored holes shall not be nearer than 5/8" to the edge of <br />a stud and shall not exceed 40% of stud width. <br />Joists or rafters may be notched at top or bottom a maximum <br />of one -sixth of depth, but not within middle third of span. Holes <br />bored in joists or rafters shall not be nearer than 2" to the <br />edge and shall not exceed one-third of the joist or rafter depth. <br />Notching of exterior and bearing/nonbearing walls shall not exceed <br />25%/40% respectively. Bored holes in bearing/nonbearing <br />walls shall not exceed 40%/60% respectively. <br />Roof diaphragm nailing to be inspected before covering. Face <br />grain of plywood shall be perpendicular to supports. <br />Floors shall have tongue and groove or blocked panel edges. <br />Plywood spans shall conform. <br />CRC TABLE R602.3(1) <br />FASTENER SCHEDULE FOR STRUCTURAL MEMBERS <br />NUMBER AND TYPE <br />SPACING OF <br />ITEM <br />DESCRIPTION OF BUILDING ELEMENTS <br />OF FASTENER a,b,c <br />FASTENERS <br />ROOF <br />1. <br />Blocking between joists or rafters to top plate, toe nail <br />3-8d (21 /2" x 0.1 13") <br />2. <br />Ceiling joists to plate, toe nail <br />3-8d (21 /2" x 0.1 13") <br />3. <br />Ceiling joists not attached to parallel rafter, laps over partitions, face nail <br />3-1Od <br />4. <br />Collar tie rafter, face nail or 11 14" X 20 gage ridge strop <br />3-10d (3" x 0.128") <br />5. <br />Rafter to plate, toe nail <br />Roof rafters to ridge, valley or hip rafters: <br />2-16d (3 1/2" x 0.135") <br />6. <br />toe nail <br />4-16d <br />x 0.135face <br />nail <br />�311/2" <br />3-16d 31 /2" x 0.135 <br />WALL <br />7. <br />Built-up corner studs <br />10d (3" x 0.128") <br />24" O.C. <br />8. <br />Built-up header, two pieces with 1/2" spacer <br />16d (3 1/2" x 0.135") <br />16" o.c. along <br />each edge <br />9. <br />Continued header, two pieces <br />16d (3 1/2" x 0.135") <br />16" o.c. along <br />each edge <br />10. <br />Continuous header to stud, toe nail <br />4-8d 2 1/2" x 0.113" <br />11. <br />Double studs, face nail <br />IOd (3" x 0.128") <br />24" O.C. <br />12. <br />Double top plates, face nail <br />IOd (3" x 0.128") <br />24" O.C. <br />13. <br />Double top plates, min. 48" offset of end joints, face nail in lapped area <br />8-16d 31 2 x 0.135 <br />14. <br />Sole plate to joist or blocking, face nail <br />16(3172T x 0.135 <br />16" O.C. <br />15. <br />Sole plate to joist or blocking at braced wall panels <br />3-16d (3 1/2" x 0.135") <br />16" O.C. <br />16. <br />Stud to sole plate, toe nail <br />3-8d (2 1/2" x 0.1 13") <br />- <br />or <br />2-16d 3 1/2" x 0.135" <br />17. <br />Top or sole plate to stud, end nail <br />2-16d 3 1/2" x 0.135" <br />18. <br />Top plates, laps at corners and intersections, face nail <br />2-10d (3"x 0.128") <br />19. <br />1" brace to each stud and plate, face nail <br />2-8d (2 1/2" x 0.113") <br />2 staples 1 3/4" <br />20. <br />1" x 6" sheathing to each bearing, face nail <br />2-8d (2 1/2" x 0.113") <br />2 staples 1 3/4" <br />21. <br />1" x 8" sheathing to each bearing, face nail <br />2-8d (2 1/2" x 0.1 13") <br />3 staples 1 3/4" <br />22. <br />Wider than 1" x 8" sheathing to each bearing, face nail <br />3-8d (2 1/2" x 0.113") <br />4 staples 1 3/4" <br />FLOOR <br />23. <br />Joist to sill or girder, toe nail <br />3-8d (2 1/2" x 0.113") <br />24. <br />1" x 6" subfloor or less to each joist, face nail <br />2-8d (2 1/2" x 0.1 13") <br />2 staples 1 3/4" <br />25. <br />2" subfloor to joist or girder, blind and face nail <br />2-16d (3 1/2" x 0.135") <br />26. <br />Rim joist to top plate, toe nail (roof applications also) <br />8d (21 1 t x 0.1 13") <br />6" O.C. <br />27. <br />2" planks (plank & beam -floor & roof) <br />2-16d (3 1/2" x 0.135") <br />At each bearing <br />Nail each layer as <br />follows: <br />32'o.c. at top an <br />28. <br />Built-up girders and beams, 2-inch lumber layers <br />lad (3" x 0.128") <br />bottom and <br />staggered.Two nail <br />at ends and at <br />each splice. <br />29. <br />Ledger strip supporting joists or rafters <br />3-16d (3 1 2" x 0.135")l <br />At ea joist or RR <br />For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 mis; Iksi = 6.895 MPa. <br />a. All nails are smooth -common, box or deformed shanks except where otherwise stated. nails used for framing and sheathing <br />connections shall have minimum average bending yield strengths as shown: 80 KSI for shank diameter of 0.192 inch (20d <br />common nail), 90 KSI for shank diameters larger than 0.142 inch but not larger than 0.177 inch, and 100 KSI for shank <br />diameters of 0.142 inch or less. <br />b. Nails are 16 gage wire and have a minimum 7/16-inch on diameter crown width. <br />c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. <br />d. Four-foot-by-8-foot or 4-foot-by-9-foot panels shall be applied \erticolly. <br />e. Spacing of fasteners not included in this table shall be based on table r602.3(2). <br />f. For regions having basic wind speed of 110 mph or greater, 8d deformed ( 2 Y2" x 0.120) nails shall be used for attaching <br />plywood and wood structural panel roof sheathing to framing within minimum 48-inch distance from gable end walls, if mean <br />roof height is more than 25 feet, up to 35 feet maximum. <br />g. For regions having basic wind speed of 100 mph or less, nails for attaching wood structural panel roof sheathing to gable <br />end wall framing shall be spaced 6 inches on center. when basic wind speed is greater than 100 mph, nails for attaching panel <br />roof sheathing to intermediate supports shall be spaced 6 inches on center for minimum 48-inch distance from ridges, eaves <br />and gable end walls; and 4 inches on center to gable end wall framing. <br />h. Gypsum sheathing shall conform to astm c 1396 and shall be installed in accordance with go 253. fiberboard sheathing shall <br />conform to ASTM C 208. <br />i. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required <br />blocking and at all floor perimeters only. spacing of fasteners on roof sheathing panel edges applies to panel edges supported by <br />framing members and required blocking. blocking of roof or floor sheath-ing panel edges perpendicular to the framing members <br />need not be provided except as required by other provisions of this code. floor perimeter shall be supported by framing members <br />or solid blocking. <br />Earthquake design data <br />Seismic importance factor. <br />and occupancy category <br />II-2 <br />Story Shear Vx <br />8.38(K) <br />Mapped spectral response <br />accelerations S.s. <br />1.51g <br />Total weight of building <br />45.89(K) <br />Mapped spectral response <br />accelerations S.1. <br />0.50 g <br />Seismic respponse coefficient(s). <br />Cs(max) <br />0.84 g <br />Site Class <br />D <br />Response modification factor(s). R <br />6.5 <br />Spectral response coefficient SDS. <br />1.19 <br />Redundancy Factor Used <br />1.3 <br />Spectral response coefficient SD1. <br />0.89 <br />Seismic design category <br />D <br />Design load bearing value of soils <br />1500psf <br />1 11 <br />Analysis Procedure Used <br />-Equivalent Lateral Force <br />Kl <br />FOR <br />Maste <br />Date: <br />Wind design data <br />Ultimate design wind speed <br />120 mph <br />NASD) ominal design speed <br />85 mph <br />Risk category <br />ll <br />Wind exposure <br />B <br />Internal pressure coefficient <br />0.18 <br />Cladding design wind <br />pressure qh <br />5.83 sf <br />P <br />SHEAR WALL SCHEDULE <br />MARK <br />MATERIAL <br />PANEL NAILING <br />BLK G TO DBL. <br />PLATE CONN. <br />SHEAR <br />CAPAC. <br />PLATE THK. <br />A. BOLTS <br />SILL PLATE <br />CONNECTION <br />PERIM. <br />FIELD <br />15/32"STRUC-1 PLY. <br />8d @ <br />8d © <br />S.S.T. "A35" @ <br />550 #/FT. <br />3x <br />5/8" @ 16"o.c. <br />16 d @ 6"o.c. <br />3' o. C. <br />12' o. c. <br />16' o. c. <br />15/32"STRUC-1 PLY. <br />8d @ <br />8d ® <br />12' <br />S.S.T. "A35" © <br />280 #/FT. <br />3x <br />5/8" @ 32"o.c. <br />16 d @ 6"o.c. <br />6' o. c. <br />o. c. <br />16' o. c. <br />1. THIS NAILING SCHEDULE IS IN ADDITION TO MIN. NAILING REQUIRED BY UBC. USE COMMON NAILS ONLY. <br />2* FRAMING AT BOUNDARY AND PANEL EDGES SHALL BE 3" NOMINAL OR WIDER AND NAILS SHALL <br />BE STAGGERED FOR ALL PLYWOOD. <br />SHEAR WALLS WITH SHEAR VALUES EXCEEDING 300#/FT. NAILING EDGE DISTANCE FOR 3x <br />BOUNDARY AND PANEL EDGE MEMBERS SHALL BE 1/2" MIN. <br />3. ANCHOR BOLTS SHALL HAVE MINIMUM EMBEDMENT OF 8" AND BEARING PLATE 2-1/2 x 2-1/2 x 1/4" <br />4. ALL INTERIOR WALLS SHALL HAVE HILTI ON WITH MINIMUM PENETRATION OF 1 1/8" INTO CONCRETE <br />SLAB @ 32" OC UNO, ICBO #2388. <br />5. THE MAX. ALLOWABLE SHEAR FOR 3-PLY PLYWOOD, LESS THAN 5/8" THICKNESS SHALL NOT <br />EXCEED 200#/FT. <br />6. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3" NOMINAL OR WIDER AND NAILS SHALL BE <br />STAGGERED WHERE 10d NAILS HAVING PENETRATION INTO FRAMING OF MORE THAN 1-5/8" <br />ARE SPACED 3" OR LESS ON CENTER. <br />7. FOR EXISTING FRAMING WITH SHEAR VALUE MORE THAN 300#/FT., 2x BLOCKING SHALL BE ADDED <br />ON TOP OF EXISTING 2x BOTTOM SILL PLATE WITH 16d NAILS @ 4"o.c. <br />8. ALL DIAPHRAGM AND SHEARWALL NAILING SHALL UTILIZE COMMON NAILS. <br />9. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. <br />ENGINIAIR, <br />Design & Development <br />Design & Development <br />3655 TORRANCE BLVD. STE 300 <br />TORRANCE, CA 90503 <br />Tel: 1-877-8211213 <br />E-Mail: info®enginiar.com <br />OQ�pF F E SS/O� <br />VEL9 q�F <br />C76091 T <br />Cr E X11 0630.2026 � <br />OWNER: <br />�IESUS ECPEL <br />PHONE: <br />ADDRESS: <br />2314 LARCHMONT AVE. <br />SANTA ANA, CA 92706 <br />SCALE: <br />N.T.S <br />DESIGN BY: <br />F. B. <br />DRAWN BY: <br />E.W <br />DATE: <br />REV.0 <br />05-24-24 <br />JOB No.: <br />18-SANA-24 <br />SHEET: <br />