My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2218 & 2220 N Richmond St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Richmond St
>
2218 N Richmond St
>
2218 & 2220 N Richmond St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:13 AM
Creation date
2/13/2026 5:00:58 AM
Metadata
Fields
Template:
Plan
Permit Number
101123779
101123780
Full Address
2218 N Richmond St
2220 N Richmond St
Street Number
2220
Street Direction
N
Street Name
Richmond
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />Planning and Building Agency <br />footings. <br />Approved <br />FOR PERMIT ISSUANCE <br />The above temporary excavation recommendations can be changed by the gpoechnW <br />consultant based on conditions to be exposed in the field during excavation aster <br />Date: <br />BUILDING FOUNDATION DESIGN GUIDELINES <br />Geotechnical Parameters For Structural Design <br />For conservative purposes, the following "lowest" code values should be used for <br />structural design, as needed. <br />a. Allowable vertical bearing earth pressure: 1,500 psf. <br />An increase of one-third is permitted when using the alternative load <br />combinations that include wind or earthquake loads. <br />b. Lateral bearing passive earth pressure: 100 ps£ per foot into competent materials <br />below the finished ground surface. <br />An increase of one third is permitted when using the alternative load <br />combinations that include wind or earthquake loads. <br />c. Lateral Sliding Resistance: cohesion = 130 psf. <br />The cohesion value is to be multiplied by the contact area. <br />In no case shall the lateral sliding resistance exceed one-half the dead load. <br />d. Soil unit weight: 120 pcf. <br />New Building Footings <br />In general, the foundation system for the proposed structures must be properly designed <br />by the civil/structural design engineer of record for this project and reviewed and <br />approved by the city prior to construction. <br />New building footings should be embedded minimum 24-inches below the adjacent <br />lowest finished grade. Minimum widths for isolated columns/pad footings, if any, should <br />be 24-inches, and for continuous wall footings should be 12-inches for one-story and 15- <br />inches for two-story portions. <br />Minimum reinforcement for new continuous footings should be two 95 re -bars at top and <br />two #5 re -bars at bottom. <br />Settlement <br />Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.