Laserfiche WebLink
19 <br />' <br />- <br />5 <br />" <br />12'-10" <br />MASTER'S <br />BEDROOM <br />BEDROOM <br /> #1 <br />5' <br />REFD/W <br />5' <br />- <br />5 <br />" <br />11' <br />33'-7" <br />47'-3" <br />LIVING <br />13'-8" <br />10 <br />' <br />- <br />1 <br />0 <br />" <br />E <br />WH <br />A/C COND. <br />UNIT <br />#2121 <br />EXISTING <br />MAIN HOUSE <br />(NOT IN CONTRACT) <br />SD <br />CM <br />SD <br />SD <br />5' <br />CLOSET <br />CL <br />O <br />S <br />E <br />T <br />11'-4" <br />WASHER /DRYER <br />STORAGE <br />KITCHEN <br />/DINING <br />BATH <br />#1 <br />BATH <br />#2 <br />MAIN <br />ENTRANCE <br />CLOSET <br />6' <br />A/C <br />COND. UNIT <br />16 <br />' <br />- <br />3 <br />" <br />1' <br />4' <br />1' <br />RANGE <br />SD <br />CM <br />SD <br />CM <br />E <br />G <br />IAQ <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br /> <br />E <br />L <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />P <br />L <br />A <br />N <br />NO.REVISIONS DATE <br />CONSULTANT <br />JOB NO: <br />DATE: <br />1ST REV: <br />DRAWN: <br />PLOTTED: <br />SCALE:AS SHOWN <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />T: 323.470.0181 E: kmassociatesince@outlook.com <br />KM ASSOCIATES INC. <br />16202 ORION AVE CHINO CA 91708 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />LI <br />N <br />H <br /> <br />L <br />E <br /> <br />A <br />N <br />D <br /> <br />D <br />A <br />V <br />I <br />D <br /> <br />F <br />R <br />E <br />U <br />D <br />E <br />N <br />B <br />E <br />R <br />G <br />E <br />R <br />SHEET TITLE <br />SHEET NUMBER <br />21 <br />2 <br />1 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />2 <br />1 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br /> <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />6 <br />- <br />2 <br />2 <br />3 <br />6 <br />SCALE 1/4" = 1'-0" <br />PROPOSED ELECTRICAL PLAN (ADU)1 <br />05-E-102 <br />ELECTRICAL GENERAL NOTES: <br />1.GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITION BEFORE AND DURING <br />CONSTRUCTION. <br />2.ALL WORKS SHALL COMPLY WITH LOCAL AND APPLICABLE CODES AND REGULATIONS. <br />3.CONTRACTOR SHALL OBTAIN NECESSARY BUILDING PERMIT PRIOR TO CONSTRUCTION. THIS <br />PLAN IS A SCOPING PLAN FOR PERMITTING PURPOSES. ELECTRICAL CONTRACTOR CAN <br />PROPOSE ALTERNATE DESIGN IN LIEU OF THIS PLAN; BASED ON ACTUAL CONDITION. <br />CONSIDER CONTINGENCIES ON BID. NO CHANGE ORDER IS ALLOWED WITHIN THE SCOPE OF <br />THIS PROJECT. <br />ADDITIONAL NOTES: <br />1.OUTLETS AREA AFCI AND GFCI. <br />2.ALL LIGHTS ARE TO BE HIGH EFFICACY W/ NO EXCEPTION. <br />3.ALL LIGHTS ARE CONTROLLED BY DAYLIGHT CONTROL DIMMER, TIMER, MOTION SENSOR, <br />OCCUPANCY DETECTION PER CODE. <br />EXHAUST FAN NOTES: <br />1.FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE <br />OF THE BUILDING, MAX. OF 3 ZONES. <br />2.FANS NOT FUNCTIONING AS COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST <br />BE CONTROLLED BY A HUMIDITY CONTROLLER. <br />ELECTRICAL NOTES: <br />1.ALL BRANCH CIRCUITS SUPPLYING 120V 15-AMPERE AND 20-AMPEREOUTLETS IN DWELLING <br />KITCHEN, FAMILY ROOMS, DINING ROOMS , LIVING ROOMS, PARLORS, LIBRARIES, DENS, <br />BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS AND SIMILAR ROOMS <br />OR AREAS, SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER. SHOW ON <br />THE PLANS. (210.12(A) CEC). <br />2.ALL WALL SPACES 2' OR MORE IN WIDTH, SHALL HAVE RECEPTACLES INSTALLED SUCH THAT <br />NO POINT MEASURED HORIZONTALLY SIS MORE THAN 6' FROM A RECEPTACLE (12' MAXIMUM <br />SPACING). SHOW MINIMUM RECEPTACLES ON THE PLANS. (210.52 (A) (1) AND (2) CEC). <br />3.SERVICES SUPPLYING DWELLING UNITS SHALL HAVE TYPE 1 OR TYPE 2 SURGE PROTECTION <br />DEVICE, PER CEC SECTION 230.67. THIS ALSO INCLUDES ANY NEW SERVICE OR SERVICE <br />REPLACEMENTS/UPGRADES ON EXISTING PREMISES. <br />4.AT LEAST ONE RECEPTACLE AT GRADE LEVEL SHALL BE INSTALLED IN BOTH THE FRONT AND <br />BACK OF EACH DWELLING UNIT. SHOW GFCI WATERPROOFED RECEPTACLES ON THE PLANS. <br />(CEC 210.52 (E) (1)). <br />SD CM <br />GFCI <br />LEGEND: <br />SMOKE AN CARBON MONOXIDE DETECTOR <br />INTERCONNECTED HARDWIRED WITH <br />BATTERY BACKUP. <br />50CFM ENERGY STAR COMPLIANT AND BE <br />DUCTED TO TERMINATE TO THE OUTSIDE OF <br />THE BUILDING. FANS, NOT FUNCTIONING AS A <br />COMPONENT OF A WHOLE HOUSE <br />VENTILATION SYSTEM, MUST BE CONTROLLED <br />BY A HUMIDITY CONTROLLER. <br />LED DOWN LIGHT, RECESSED MOUNT. <br />DUPLEX RECEPTACLE, WALL MOUNTED. <br />GROUND FAULT CIRCUIT INTERRUPTED, <br />WALL MOUNTED. <br />WP, WATER-PROOFED. <br />IAQ EXHAUST FAN TYPE. 0.35 FAN <br />EFFICIENCY, 45 CFM AIRFLOW PER T24 <br />SUPPLY <br />DIFFUSER (SA) <br />RETURN <br />AIR GRILLE (RA)