My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2121 N Lewis St & Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Lewis St
>
2121 N Lewis St Unit# 2
>
2121 N Lewis St & Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:55 AM
Creation date
2/13/2026 5:00:58 AM
Metadata
Fields
Template:
Plan
Permit Number
101122606
Full Address
2121 N Lewis St Unit# 2
Street Number
2121
Street Direction
N
Street Name
Lewis
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
D4 <br />15 <br />" <br />15 <br />" <br />19 <br />' <br />- <br />5 <br />" <br />12'-10" <br />MASTER'S <br />BEDROOMBEDROOM <br /> #1 <br />5' <br />36 <br />" <br />CL <br />E <br />A <br />R <br />24''W X 24''H <br />SD WINDOW <br />W3 <br />REFD/W <br />5' <br />- <br />5 <br />" <br />11' <br />33'-7" <br />47'-3" <br />LIVING <br />13'-8" <br />10 <br />' <br />- <br />1 <br />0 <br />" <br />E <br />(E) ELECTRIC <br />METER <br />(N) A/C <br />CONDENSER <br />(E) A/C <br />CONDENSER <br />WH <br />A/C COND. <br />UNIT <br />#2121 <br />EXISTING <br />MAIN HOUSE <br />(NOT IN CONTRACT) <br />SD <br />CM <br />SD <br />SD <br />50CFM <br />EXHAUST <br />FAN. <br />DUCTED <br />OUTSIDE <br />THE BLDG. <br />5' <br />CLOSET <br />D4 <br />D4 <br />38 <br />15 <br />" <br />15 <br />" <br />30" <br />30 <br />" <br />30 <br />" <br />CL <br />O <br />S <br />E <br />T <br />11'-4" <br />D3 <br />W1 <br />W3 <br />W1 <br />48''W X 48''H <br />SD WINDOW <br />W1 <br />WASHER <br />/DRYER <br />STORAGE <br />30" <br />24''W <br />X 24''H <br />SLIDING <br />WDW <br />KITCHEN <br />/DINING <br />W2 <br />36" <br />CLEAR <br />36" <br />CLEAR <br />BATH <br />#1 <br />BATH <br />#2 <br />48''W X 48''H <br />SLIDING <br />WINDOW30 <br />" <br />9' <br />- <br />6 <br />" <br />MAIN <br />ENTRANCE <br />D1 <br />48''W X 48''H <br />SD WINDOW <br />48''W X 48''H <br />SLIDING <br />WINDOW <br />W1W1 <br />60" <br />48 <br />" <br />CLOSET <br />6' <br />5'W X 80''H <br />FRENCH-TYPE <br />SWING DOOR <br />D2 <br />8' <br />W <br /> <br />X <br /> <br />8 <br />0 <br />' <br />' <br />H <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />D <br />O <br />O <br />R <br />D3 <br />50CFM EXHAUST <br />FAN. DUCTED <br />OUTSIDE THE BLDG. <br />A/C <br />COND. UNIT <br />30''W X 36''H <br />SD WINDOW <br />16 <br />' <br />- <br />3 <br />" <br />B <br />A <br />C <br />1' <br />1' <br />EXISTING SFD <br />(EAVES PROJECTION) <br />7.75" <br />(THRESHOLD) <br />PROVIDE 130 CFM (MIN) <br />EXHAUST RATE <br />KITCHEN HOOD OVER <br />E-RANGE. <br />LOCAL EXHAUST <br />SYSTEM VENTED TO <br />OUTDOORS <br />1-HR <br />FIRE-RATED <br />WALL <br />2 <br />01-A-230 <br />RANGE <br />SD <br />CM <br />SD <br />CM <br />E <br />G <br />2 <br />01-A-230 <br />NOTE: <br />ELECTRIC RANGE, <br />NO GAS HOOK ON <br />STOVE. <br />(N) WATER HEATER, <br />NEEA HEAT PUMP <br />65 GAL TANK <br />RHEEM BRAND <br />(E) FENCE <br />10 <br />' <br />PU <br />E <br />SCE EASEME <br />N <br />T <br /> <br />L <br />I <br />N <br />E <br /> <br />SC <br />E <br /> <br />E <br />A <br />S <br />E <br />M <br />E <br />N <br />T <br /> <br />L <br />I <br />N <br />E <br /> <br />PROPERTY L <br />I <br />N <br />E <br />10' <br />PUE <br />5'-11" <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PROVIDE IAQ <br />EXHAUST FAN TYPE <br />0.35 FAN EFFICIENCY <br />45 CFM AIRFLOW <br />PER T24 <br />30'' WIDE X <br />22'' DEPTH <br />ATTIC <br />ACCESS <br />IPL <br />PROPOSED ADU <br />(EAVES PROJECTION)2' <br />2' <br />1-HR FIRE-RATED <br />WALL PER CRC <br />TABLE R302.1(1) <br />15 <br />02-S3.1 <br />1-HR FIRE-RATED <br />EAVES PER CRC <br />TABLE R302.1(1) <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />NO.REVISIONS DATE <br />CONSULTANT <br />JOB NO: <br />DATE: <br />1ST REV: <br />DRAWN: <br />PLOTTED: <br />SCALE:AS SHOWN <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />T: 323.470.0181 E: kmassociatesince@outlook.com <br />KM ASSOCIATES INC. <br />16202 ORION AVE CHINO CA 91708 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />LI <br />N <br />H <br /> <br />L <br />E <br /> <br />A <br />N <br />D <br /> <br />D <br />A <br />V <br />I <br />D <br /> <br />F <br />R <br />E <br />U <br />D <br />E <br />N <br />B <br />E <br />R <br />G <br />E <br />R <br />SHEET TITLE <br />SHEET NUMBER <br />21 <br />2 <br />1 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />2 <br />1 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br /> <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />6 <br />- <br />2 <br />2 <br />3 <br />6 <br />SCALE 1/4" = 1'-0" <br />PROPOSED FLOOR PLAN (ADU)1 <br />NOTES: <br />1.FINISH MATERIAL INCLUDING SEALANTS, CAULK, <br />PAINTS AND COATINGS, ADHESIVES, CARPET <br />SYSTEMS, ETC.SHALL MEET THE (VOC) EMISSION <br />LIMITS PER LAC GBSC CHAPTER 4. <br />2.OPENING SHALL HAVE CORROSION-RESISTANT <br />WIRE MESH OR OTHER APPROVED MATERIAL WITH <br />1/16'' MINIMUM AND 1/4'' MAXIMUM OPENING. <br />3.A MINIMUM OF 1'' AIRSPACE SHALL BE PROVIDED <br />BETWEEN INSULATION AND ROOF SHEATHING. <br />4.CLOTHES DRYER MOISTURE EXHAUST DUCT MUST <br />BE 4" IN DIAMETER AND LENGTH SHALL BE <br />REDUCED BY 2' FOR EVERY ELBOW IN EXCESS OF <br />TWO. <br />ADDITIONAL NOTES ON ALARMS: <br />1.THE ALARM SHALL PROVIDE AN AUDIBLE <br />WARNING WHEN THE DOOR OR ITS SCREEN, <br />IF PRESENT, ARE OPENED. <br />2.THE ALARM(S) SHALL BE LISTED AND <br />LABELED IN ACCORDANCE WITH UL 2017 AND <br />INDEPENDENTLY CERTIFIED TO THE ASTM <br />STANDARD F2208. <br />3.THE ALARMS SHALL BE EQUIPPED WIT H A <br />DEACTIVATION SWITCH LOCATED IN <br />ACCORDANCE 54" ABOVE THE FLOOR FOR <br />UNITS NOT REQUIRED TO BE ACCESSIBLE, <br />AND BETWEEN 48 AND 54 INCHES FOR UNITS <br />REQUIRED TO BE ACCESSIBLE. <br />01-A-201 <br />1.SHOWER FLOORS AND WALLS ABOVE <br />BATHTUBS WITH INSTALLED SHOWER HEAD <br />SHALL BE FINISHED WITH NON-ABSORBENT <br />SURFACE TO HEIGHT NOT LESS THAN 6' ABOVE <br />FLOOR. <br />2.REINFORCEMENT FOR GRAB BARS MUST BE <br />INSTALLED IN ONE BATHROOM ON THE ENTRY <br />LEVEL IN ACCORDANCE WITH SECTION <br />R327.1.1. <br />3. REINFORCEMENT SHALL BE LOCATED <br />BETWEEN 32-INCHES AND 39 1/4-INCHES <br />ABOVE THE FINISHED FLOOR FLUSH WITH THE <br />WALL. <br />4. WATER CLOSET REINFORCEMENT SHALL BE <br />INSTALLED ON BOTH SIDE WALLS OF THE <br />FIXTURE, OR ON ONE SIDE WALL AND THE <br />BACK WALL. <br />5.ELECTRICAL RECEPTACLE OUTLETS, <br />SWITCHES AND CONTROLS (INCLUDING <br />CONTROLS FOR HEATING, VENTILATION AND <br />AIR CONDITIONING) INTENDED TO BE USED BY <br />OCCUPANTS SHALL BE LOCATED NO MORE <br />THAN 48-INCHES MEASURED FROM THE TOP OF <br />THE OUTLET BOX AND NOT LESS THAN <br />15-INCHES MEASURED FROM THE BOTTOM OF <br />THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />(CRC R327.1.2). <br />6.DOORBELL BUTTONS OR CONTROLS, WHEN <br />INSTALLED, SHALL NOT EXCEED 48-INCHES <br />ABOVE EXTERIOR FLOOR OR LANDING, <br />MEASURED FROM THE TOP OF THE DOORBELL <br />BUTTON ASSEMBLY. (CRC R327.1.4). <br />CMSD <br />LEGEND: <br />PROPOSED SHEAR WALL <br />PROPOSED WALL. <br />"SMOKE ALARM" SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP AND SHALL BE <br />INSTALLED IN ACCORDANCE WITH NFPA 72. <br />"CARBON MONOXIDE ALARM" SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP. <br />50CFM ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. <br />FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE <br />CONTROLLED BY A HUMIDITY CONTROLLER. <br />SUPPLY <br />DIFFUSER (SA) <br />RETURN <br />AIR GRILLE (RA) <br />BATHROOM NOTES: <br />ADDITIONAL NOTES: <br />1 "ALL DUCT AND OTHER RELATED AIR DISTRIBUTION <br />COMPONENT OPENINGS SHALL BE COVERED WITH <br />TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL <br />STARTUP OF THE HEATING, COOLING AND <br />VENTILATING EQUIPMENT." <br />(4.504.1) <br />2."ARCHITECTURAL PAINTS AND COATINGS, <br />ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY <br />WITH THE VOLATILE ORGANIC COMPOUND (VOC) <br />LIMITS LISTED IN TABLES 4.504.1-4.504.3." <br />4.504.2.1-4.504.2.3 <br />3.LACRC SECTION T327 AGING-IN PLACE DESIGN AND <br />FALL PREVENTION INCORPORATED IN THE DESIGN <br />REQUIREMENTS. <br />ANNULAR SPACED AROUND PIPES, ELECTRIC CABLES, <br />CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM <br />PLATES AT EXTERIOR WALLS SHALL BE PROTECTED <br />AGAINST THE PASSAGE OF RODENTS BY CLOSING <br />SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE <br />MASONRY OR SIMILAR METHODS (4.406.1) <br />MATERIAL CONSERVATION AND RESOURCE <br />EFFICIENCY NOTES :
The URL can be used to link to this page
Your browser does not support the video tag.