My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2129 S Wright St - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Wright St
>
2129 S Wright St
>
2129 S Wright St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:13 AM
Creation date
2/13/2026 5:00:58 AM
Metadata
Fields
Template:
Plan
Permit Number
20185319
101122714
Full Address
2129 S Wright St
Street Number
2129
Street Direction
S
Street Name
Wright
Street Suffix
St
Document Relationships
101122714 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Wright St\2129 S Wright St
20185319 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Wright St\2129 S Wright St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CLIENT APPROVAL <br />x_________________ <br />Client Initials <br />To scale on 24x36 paper <br />X___________________________ <br />VICINITY MAP:PROJECT SCOPE:DRAWING INDEX PERMITTING / PLANNING NOTES: <br />PROJECT ADDRESS AERIAL PHOTO:PROJECT TEAM: <br />THIS INSTALLATION CONSISTS OF A NEW ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM. <br />THE PV SYSTEM IS STATIC MOUNTED. <br />THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE OPERATED IN PARALLEL WITH <br />THE PG&E ELECTRIC GRID PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE <br />AND UTILITY INTERCONNECT AGREEMENT <br />CONDITIONS OF APPROVAL: <br />1. ALL CONSTRUCTION SHALL OCCUR BETWEEN THE HOURS OF 7AM & 7PM, EXCEPT FOR <br />THE PURPOSE OF EMERGENCIES. <br />1. THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE AUTHORITY HAVING JURISDICTION AND <br />FIRST EDISON <br />2. THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS: <br />2022 CALIFORNIA BUILDING CODE (CBC 2022) <br />2022 CALIFORNIA ELECTRIC CODE (CEC 2022) <br />2022 CALIFORNIA FIRE CODE (CFC 2022) <br />2022 CALIFORNIA ENERGY CODE (CEnC 2022) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG 2022) <br />2022 CALIFORNIA PLUMBING CODE (CPC 2022) <br />2022 CALIFORNIA MECHANICAL CODE (CMC 2022) <br />AUTHORITY HAVING JURISDICTION <br />3. SYSTEM UTILIZES GROWATT INVERTERS AND APS RSD WHICH MEET 690.12 MODULE <br />LEVEL RAPID SHUTDOWN REQUIREMENTS. <br />4. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A <br />NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL <br />SAFETY HEALTH ADMINISTRATION. <br />5. ELECTRICAL EQUIPMENT SHALL BE LISTED OR CERTIFIED BY A RECOGNIZED ELECTRICAL TESTING <br />LABORATORY OR APPROVED BY THE DEPARTMENT. <br />6. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES, TRANSFORMERS, <br />VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ECT.) OR TO THE LOCATION OF THE HOOK-UP. THE <br />CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE <br />LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR <br />ADDITIONAL EXPENSES. <br />7. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE <br />AVAILABLE AT THE JOB SITE. <br />8. INSTALLATION OF THE PV SYSTEM IN PARALLEL WITH THE UTILITY POWER SHALL BE <br />INSTALLED ONLY BY QUALIFIED PERSONS. 705.6. <br />9. THE OUTPUT CHARACTERISTICS OF THE PV SYSTEM SHALL BE COMPATIBLE WITH THE <br />VOLTAGE, WAVE SHAPE, AND FREQUENCY OF THAT OF THE UTILITY OUTPUT. 705.14. <br />10. INTERCONNECTED ELECTRIC POWER PRODUCTION SOURCES SHALL BE GROUNDED IN <br />ACCORDANCE WITH ARTICLE 250. 705.50. <br />SITE CONTACT: <br />CONTRACTOR: <br />Confidentiality Statement: <br />8/29/2024 11:58:12 PM <br />Title Sheet <br />Mu <br />i <br />r <br /> <br />C <br />h <br />a <br />s <br />e <br /> <br />P <br />l <br />u <br />m <br />b <br />i <br />n <br />g <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />( <br />M <br />C <br />P <br />) <br />21 <br />2 <br />9 <br /> <br />S <br /> <br />W <br />r <br />i <br />g <br />h <br />t <br /> <br />S <br />t <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />92 <br />7 <br />0 <br />5 <br />T101 <br />Muir Chase Plumbing Santa Ana (MCP) <br />2129 S Wright St Santa Ana, CA 92705 <br />SOLAR ELECTRIC SYSTEM PROJECT - 32.4kW DC STC RATING / 29.536kW AC CEC RATING <br />---- <br />SOLAR ELECTRIC SYSTEM <br />THIS PROJECT ENTAILS THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM AT Muir Chase <br />Plumbing Santa Ana (MCP) THE SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO THE <br />UTILITY GRID. <br />This drawing is the property of SOL <br />IRVINE. This information is <br />confidential and is to be used only <br />in connection with work described <br />by SOL IRVINE. No part is to be <br />disclosed to others without written <br />permission from SOL IRVINE <br />SOL IRVINE <br />LIC # C46 - 1050892 <br />EXP: 3/31/25 <br />SOL IRVINE <br />SOL IRVINE <br />16200 SCIENTIFIC WAY, IRVINE, CA <br />92618 <br />TEL: 925-548-4924 <br />LIC # C46 - 1050892 <br />SOL IRVINE <br />925-548-4924 <br />16200 SCIENTIFIC WAY, <br />IRVINE, CA 92618 <br />Sheet #Sheet Name <br />T101 Title Sheet <br />T102 Notes <br />A101 Site Plan <br />A102 Array Layout <br />S1.0 Sollega Layout <br />S1.1 Sollega Layout <br />S2.0 Drawing Info <br />S3.0 Roof Framing <br />E101 Array Wiring <br />E201 Single Line Diagram <br />SP101 Signage / Spec Sheets <br />SP102 Spec Sheets <br />SP103 Spec Sheets <br />SP104 Spec Sheets <br />MODULE: <br />(72) VIETNAM SUNERGY JOINT STOCK COMPANY, <br />VSUN450-144BMH, 450W <br />PTC: 418.6ptc <br />INVERTER: <br />(2) SHENZHEN GROWATT NEW ENERGY CO., LTD., <br />MIN 11400TL-XH-US [240V] <br />PV LOCATION <br />SITE LOCATION <br />SITE LOCATION <br />APN: 014-262-31 <br />No. <br />Descriptio <br />n <br />Date <br />Bldg #101122714 & 201820185319 <br />APPROVALS: <br />PLNG - C. Santans <br />BLDG - A. So <br />PUBLIC WORKS - Y. Soto <br />ELECT - M. Smith
The URL can be used to link to this page
Your browser does not support the video tag.