Docusign Envelope ID: 244D77F2-FOA2-4894-B44B-1CO03F256B68 <br />CAST -IN -PLACE -CONCRETE <br />2.2 SLUMP: <br />B. <br />PLACING CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301 AND ACI 304 AND <br />SHALL BE CARRIED OUT AT SUCH A RATE THAT THE CONCRETE PREVIOUSLY <br />PART <br />1: GENERAL <br />A. <br />THE MAXIMUM SLUMP SHALL NOT EXCEED 3" EXCEPT FOR CONCRETE TO BE <br />PLACED IS STILL PLASTIC AND INTEGRATED WITH THE FRESHLY PLACE CONCRETE. <br />PLACED IN FORMS 8" WIDE OR LESS, WHERE THE MAXIMUM SLUMP SHALL BE 4". <br />CONCRETING, ONCE STARTED, SHALL BE CARRIED ON AS A CONTINUOUS <br />OPERATION UNTIL THE SECTION IS COMPLETED. NO COLD JOINTS SHALL BE <br />1.1 SUMMARY: <br />B. <br />THE DETERMINATION OF SLUMP SHALL CONFORM TO ASTM C143. <br />ALLOWED. <br />A. <br />FURNISH AND INSTALL ALL CAST -IN -PLACE CONCRETE, REINFORCING AND <br />2,3 MIXING: <br />C. <br />CONSTRUCTION JOINTS: USE KEYWAYS, CONTINUE REINFORCEMENT THROUGH JOINT. <br />ACCESSORIES, AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. <br />1.2 SUBMITTALS: <br />A. <br />THE CONTRACTOR SHALL USE READY -MIXED CONCRETE, MIXED AND DELIVERED IN <br />D. <br />EXPANSION JOINTS: FOR EXTERIOR WORK, LOCATE AT 30'-0" O.C. MAXIMUM, AT <br />CONFORMANCE WITH ASTM C94. <br />APPROVED LOCATIONS. PROVIDE SMOOTH DOWELS ACROSS JOINT WHICH PERMIT 1" <br />A. <br />PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA AND INSTALLATION <br />HORIZONTAL MOVEMENT AND NO VERTICAL SHEAR MOVEMENT. <br />INSTRUCTIONS FOR EACH MATERIAL AND PRODUCT USED. <br />2.4 MIXTURES: <br />E. <br />ISOLATION JOINTS: PROVIDE BETWEEN SLABS AND VERTICAL ELEMENTS SUCH AS <br />B. <br />SHOP DRAWINGS: SUBMIT SHOP DRAWINGS INDICATING MATERIAL CHARACTERISTICS, <br />A. <br />THE CONCRETE SHALL CONTAIN AN AIR -ENTRAINING ADMIXTURE COMPLYING WITH <br />COLUMNS AND STRUCTURAL WALLS. <br />DETAILS OF CONSTRUCTION, CONNECTIONS, AND RELATIONSHIP WITH ADJACENT <br />THE REQUIREMENTS OF ASTM C-260 AND ACI 212.1 R AND A WATER -REDUCING <br />CONSTRUCTION. <br />ADMIXTURE COMPLYING WITH THE REQUIREMENTS OF ASTM C-494 AND ACI <br />F. <br />CONTROL JOINTS: PROVIDE SAWN OR TOOLED JOINTS OR REMOVABLE INSERT <br />212.1R. ADMIXTURES SHALL BE PURCHASE AND BATCHED IN LIQUID SOLUTION. <br />STRIPS; DEPTH EQUAL TO 1/4" SLAB THICKNESS. SPACING SHALL BE AS <br />1. SHOP DRAWINGS SHALL BE PREPARED AND STAMPED BY A QUALIFIED <br />THE USE OF CALCIUM CHLORIDE OR AN ADMIXTURE CONTAINING CALCIUM <br />REQUIRED AND APPROVED. <br />ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT. <br />CHLORIDE IS PROHIBITED. <br />G. <br />ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED AND COMPACTED BY <br />C. <br />MIX DESIGN: SUBMIT FOR APPROVAL MIX DESIGN PROPOSED FOR USE. <br />B. <br />ADMIXTURES SHALL BE OF THE SAME MANUFACTURER TO ASSURE COMPATIBILITY. <br />VIBRATION, SPADING, RODDING, OR FORKING DURING THE OPERATION OF PLACING <br />AND DEPOSITING IN ACCORDANCE WITH ACI 309. THE CONCRETE SHALL BE <br />1.3 QUALITY <br />ASSURANCE: <br />C. <br />ACCEPTABLE MANUFACTURERS ARE: <br />WORKED AROUND REINFORCEMENT, EMBEDDED ITEMS, AND INTO THE CORNERS OF <br />THE FORMS SO AS TO ELIMINATE ALL AIR AND STONE POCKETS. <br />A. <br />COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF <br />1. W.R. GRACE 3. MASTER BUILDERS <br />ACCEPTABLE MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR <br />2• SIKA GROUP 4. EUCLID CHEMICAL CO <br />SERVICE FOR A MINIMUM OF THREE YEARS. USE EXPERIENCED INSTALLERS. <br />DELIVER, HANDLE, STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S <br />2.5 CURING <br />COMPOUNDS <br />3.5 FINISHING: <br />B. <br />TESTING: EMPLOY AN INDEPENDENT TESTING AGENCY ACCEPTABLE TO OWNER TO <br />A. <br />CURING COMPOUNDS SHALL CONFORM TO ASTM C309, TYPE 1, ID, CLASS A <br />AND B AND ASTM C171 AS APPLICABLE <br />A. <br />FINISHING OF ALL SLABS SHALL BE IN ACCORDANCE WITH ACI 302.1; SECTION 7.2 <br />DESIGN CONCRETE MIXES AND TO PERFORM MATERIAL EVALUATION TESTS. PROVIDE <br />WITH A MINIMUM OF THREE TROWELINGS. <br />4 AND 28 DAY CYLINDER TESTS. COMPLY WITH ASTM C 143, C 173, C 31 AND <br />PART <br />3: EXECUTION <br />C 39. <br />1. INTERIOR SLAB FINISH TOLERANCE AS MEASURED IN ACCORDANCE WITH ASTM <br />E 1155, SHALL HAVE AN OVERALL TEST F NUMBER FOR FLATNESS, FF=20 <br />C. <br />STANDARDS <br />. <br />31 GENERAL <br />AND FOR LEVEL, FL=15. THE MINIMUM LOCAL NUMBER FOR FLATNESS, FF=15 <br />AND FOR LEVEL, FL=10. <br />1. ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. <br />A. <br />CONSTRUCT AND ERECT FORMWORK IN ACCORDANCE WITH ACI 301 ACI 347. <br />2• EXTERIOR SLAB FINISH SHALL BE FLAT (FF=20) AND SHALL BE SLOPED A <br />2. ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AND <br />B. <br />COLD -WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306. <br />MINIMUM OF 1/8" PER FOOT TO A MAXIMUM OF 1/4" PER FOOT TO PREVENT <br />CRSI MANUAL OF STANDARD PRACTICE. <br />C. <br />HOT -WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305. <br />PONDING WATER. <br />PART <br />2: PRODUCTS <br />3.2 INSERTS. <br />EMBEDDED COMPONENTS AND OPENINGS: <br />B. <br />SURFACES OF SLABS SHALL RECEIVE TWO COATS OF CLEAR SEALER/HARDENER. <br />2.1 MATERIALS <br />A. <br />CONTRACTOR SHALL CHECK ALL CIVIL, ARCHITECTURAL, STRUCTURAL, AND <br />C. <br />ABOVE GRADE WALL SURFACES SHALL HAVE A SMOOTH FORM FINISH AS DEFINED <br />ELECTRICAL DRAWINGS FOR OPENINGS, SLEEVES, ANCHOR BOLTS, INSERTS AND <br />IN CHAPTER 10 OF ACI 301. <br />A. <br />MATERIALS SHALL CONFORM TO THE RESPECTIVE PUBLICATIONS AND OTHER <br />OTHER ITEMS TO BE BUILT INTO THE CONCRETE WORK. <br />REQUIREMENTS SPECIFIED HEREIN. <br />3.6 CURING: <br />B. <br />CEMENT: CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. CEMENT MAY BE <br />B. <br />COORDINATE THE WORK OF OTHER SECTIONS FORMING AND SETTING OPENINGS, <br />RECESSES, SLOTS, CHASES, ANCHORS, INSERTSS AND OTHER ITEMS TO BE <br />A. <br />FRESHLY DEPOSITED CONCRETE SHALL BE PROTECTED FROM PREMATURE DRYING <br />BAGGED OR BULK. CEMENT SHALL BE USED FROM ONLY ONE MILL THROUGHOUT <br />EMBEDDED. <br />AND EXCESSIVELY HOT OR COLD TEMPERATURES AND SHALL BE MAINTAINED WITH <br />PROJECT. <br />MINIMAL MOISTURE LOSS AT A RELATIVELY CONSTANT TEMPERATURE FOR A PERIOD <br />C. <br />EMBEDDED ITEMS SHALL BE SET ACCURATELY IN LOCATION, ALIGNMENT, ELEVATION, <br />OF TIME NECESSARY FOR THE HYDRATION OF THE CEMENT AND PROPER <br />C. <br />FINE AGGREGATE: FINE AGGREGATE SHALL CONFORM TO ASTM C33-08 AND SHALL <br />AND PLUMBNESS. LOCATE AND MEASURE FROM ESTABLISHED SURVEYED <br />HARDENING OF THE CONCRETE. <br />BE UNIFORMLY GRADED, CLEAN, SHARP, WASHED MATERIAL OR CRUSHED SAND, <br />REFERENCE BENCHMARKS. <br />FREE FROM ORGANIC IMPURITIES. <br />B. <br />CURING SHALL IMMEDIATELY FOLLOW THE FINISH OPERATION. CONCRETE SHALL BE <br />D. <br />EMBEDDED ITEMS SHALL BE ANCHORED INTO PLACE AS REQUIRED TO PREVENT <br />KEPT CONTINUOUSLY MOIST AT LEAST OVERNIGHT, IMMEDIATELY FOLLOWING THE <br />D. <br />COURSE AGGREGATE: COURSE AGGREGATE SHALL CONFORM TO ASTM C33-08 AND <br />MOVEMENT DURING CONCRETE PLACEMENT AND CONSOLIDATION. COMPONENTS <br />INITIAL CURING. BEFORE THE CONCRETE HAS DRIED, ADDITIONAL CURING SHALL BE <br />SHALL BE NATURAL WASHED GRAVEL OR WASHED CRUSHED ROCK HAVING HARD, <br />FORMING A PART OF A COMPLETE ASSEMBLY SHALL BE ALIGNED BEFORE <br />ACCOMPLISHED BY ONE OF THE FOLLOWING MATERIALS OR METHODS: <br />STRONG, DURABLE PIECES, FREE FORM ADHERENT COATINGS, THE MAXIMUM SIZE <br />ANCHORING. PROVIDE TEMPORARY BRACING, ANCHORAGE, AND TEMPLATES AS <br />OF COARSE AGGREGATE SHALL BE 3/4" IN ACCORDANCE WITH THE REQUIREMENTS <br />REQUIRED TO MAINTAIN THE SETTING AND ALIGNMENT. <br />1. PONDING OR CONTINUOUS SPRINKLING <br />OF ASTM C33-08; GRADATION SIZE NO. 67. <br />3.3 REINFORCEMENT <br />PLACEMENT: <br />2. ABSORPTIVE MAT OR FABRIC KEPT CONTINUOUSLY WET <br />E. <br />WATER: WATER USED IN THE CONCRETE MIX SHALL BE POTABLE, CLEAN, AND <br />FREE FROM OILS, ACIDS, SALTS, CHLORIDES, ALKALI, SUGAR, VEGETABLE, OR <br />A. <br />REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH CHECKED AND RELEASED <br />3. NON -ABSORPTIVE FILM (POLYETHYLENE) OVER A PREVIOUSLY SPRINKLED <br />OTHER INJURIOUS SUBSTANCES. <br />DRAWINGS AND ACI 301 AND ACI 315; SECURELY WIRE -TIE REINFORCEMENT AT <br />SURFACE <br />ALL INTERSECTIONS. <br />F. <br />REINFORCING STEEL: ALL BARS ARE TO BE NEW BILLET STEEL CONFORMING TO <br />4. SAND OR OTHER COVERING KEPT CONTINUOUSLY WET <br />ASTM A615, GRADE 60. BENDING DETAILS ARE TO CONFORM TO THE STANDARDS <br />B. <br />ACCURATELY POSITION, SUPPORT AND SECURE REINFORCEMENT AGAINST <br />OF ACI 318. <br />DISPLACEMENT FROM FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT AND <br />5. CONTINUOUS STEAM (NOT EXCEEDING 150 DEGREES F) OR VAPOR MIST BATH. <br />CONSOLIDATION. REINFORCING SHALL BE SUPPORTED ON METAL CHAIRS, RUNNERS, <br />G. <br />G <br />FORMS: THE FORMS SHALL BE TRUE AND RIGID AND CONFORM TO SHAPE, LINE <br />H <br />BOLSTERS, SPACERS, AND HANGERS. <br />6. SPRAYED -ON CURING COMPOUND APPLIED IN TWO COATES, SPRAYED IN <br />AND DIMENSIONS AS SHOWN ON THE DRAWINGS. ALL FORMS SHALL RIGIDLY <br />PERPENDICULAR DIRECTIONS. <br />CONSTRUCTED, BRACED AND TIED TO PREVENT ANY DEFLECTION OR DISPLACEMENT <br />C. <br />SPLICES OF REINFORCING BARS SHALL BE CLASS B UNLESS SHOWN OTHERWISE. <br />DURING PLACING OF CONCRETE. ALL EXPOSED CORNERS AND EDGES SHALL HAVE <br />SPLICES SHALL BE STAGGERED. FULL DEVELOPMENT LENGTH SHALL BE PROVIDED <br />C. <br />THE FINAL CURING SHALL CONTINUE UNTIL THE CUMULATIVE NUMBER OF DAYS OR <br />3/4" FILLETS. ALL JOINTS SHALL BE MORTAR TIGHT; OPEN JOINTS SHALL BE <br />ACROSS JOINTS. <br />FRACTION THEREOF, NOT NECESSARILY CONSECUTIVE, DURING WHICH TEMPERATURE <br />SEALED AS REQUIRED. <br />OF THE AIR IN CONTACT WITH CONCRETE IS ABOVE 50 DEGREES F HAS TOTALED <br />D. <br />LOCATE REINFORCING TO PROVIDE CONCRETE COVER AND SPACING SHOWN ON <br />SEVEN (7) DAYS. CONCRETE SHALL NOT BE PERMITTED TO FREEZE DURING THE <br />H. <br />CONCRETE: <br />THE DRAWINGS. MINIMUM COVER SHALL BE AS REQUIRED BY ACI 318. <br />CURING PERIOD. RAPID DRYING AT THE END OF THE CURING PERIOD SHALL BE <br />PREVENTED. <br />1. PROPORTIONING: CONCRETE SHALL CONFORM TO THE FOLLOWING: <br />E. <br />WELDING OF AND TO ANY REINFORCING MATERIALS INCLUDING TACK WELDING OF <br />CROSSING BARS IS STRICTLY PROHIBITED. BARS SHALL BE FREE OF FLAKY OR <br />END OF SECTION <br />a. CEMENT-6 SACKS PER CUBIC YARD, MINIMUM <br />SCALY RUST AT THE TIME THE CONCRETE IS PLACED. <br />b. WATER SHALL BE KEPT TO AN ABSOLUTE MINIMUM TO MAINTAIN SLUMP AS <br />3.4 CONCRETE <br />PLACEMENT: <br />SPECIFIED <br />A. <br />PRIOR TO PLACING CONCRETE, FORMS AND REINFORCEMENT SHALL BE <br />c. AGGREGATE; SAND FACTOR SHALL BE AS REQUIRED TO GIVE THE BEST <br />THOROUGHLY INSPECTED. ALL WOOD CHIPS, DIRT, ETC., AS WELL AS ALL <br />WORKABLE MIX WITHIN THE RANGE OF 46% TO 52% OF TOTAL AGGREGATE. <br />TEMPORARY BRACING, TIES, AND CLEATS REMOVED, AND ALL OPENINGS FOR <br />UTILITIES PROPERLY BOXED, ALL FORMS SHALL BE PROPERLY SECURED IN THEIR <br />d. STRENGTH-4,000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE <br />CORRECT POSITION AND MADE TIGHT. ALL REINFORCING AND EMBEDDED ITEMS <br />SHALL BE SECURED IN THEIR PROPER LOCATIONS.. ALL OLD AND DRY CONCRETE <br />e. ALL CONCRETE SHALL CONTAIN A WATER -REDUCING AGENT AND SHALL <br />AND DIRT SHALL BE CLEANED AND ALL STANDING WATER AND OTHER FOREIGN <br />HAVE THREE (3) TO FIVE (5) PERCENT ENTRAINED AIR. <br />MATTER REMOVED. <br />JIHiV <br />Y: <br />Planning and Building Ager <br />Q� usio <br />NC <br />terOO999 <br />V <br />� <br />F <br />ENGINEERING LICENSE: <br />STATE OF CALIFORNIA <br />ENGINEER: PE#: DISCIPLINE: <br />SDK SHELTON D KEISLING 24647 ELECTRICAL E <br />DJW DAVID J WALDRON 25608 ELECTRICAL E <br />THE TERRANCE M. SUPER 17150 ELECTRICAL E <br />Leadarbo!3r <br />PLANS PREPARED FOR: <br />AGI l <br />PLANS PREPARED BY: <br />�SSC <br />DRAWING NOTICE: <br />THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE SOLE <br />PROPERTY OF SSC, IN AND IS LENT TO THE BORROWER FOR <br />THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF <br />THE LOAN OF THIS DRAWING, THE BORROWER PROMISES AND <br />AGREES TO RETURN IT UPON REQUEST AND AGREES THAT IT <br />WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE <br />DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY <br />PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED. <br />SUBMITTALS: <br />DESCRIPTION <br />DATE <br />BY <br />REV <br />ISSUED FOR REVIEW <br />11/22/24 <br />ART <br />0 <br />REVISED PER CLIENT COMMENTS <br />12/13/24 <br />ART <br />1 <br />REVISED PER CLIENT COMMENTS <br />01/28/25 <br />DWO <br />2 <br />REVISED PER CLIENT COMMENTS <br />09/05/25 <br />TJM <br />3 <br />REVISED PER AHJ COMMENTS <br />11/07/25 <br />EDA <br />4 <br />APPLICANT SITE NAME: <br />CLEAN HARBORS (SANTA ANA) <br />APPLICANT SITE NUMBER: <br />AGI-EV-0006 <br />SITE ADDRESS. <br />2120 S YALE STREET <br />SANTA ANA, CA 92704 <br />SHEET DESCRIPTION: <br />SHEET#: <br />SPECIFICATIONS <br />SP-1.1 <br />(2 OF 5) <br />