Laserfiche WebLink
Drawn By: <br />Power & <br />Distribution <br />16450 Phoebe Avenue <br />La Mirada, CA 90638 <br />Phone: (714)-307-9198 <br />File Name: <br />Scale: <br />Date: <br />Drawing: <br />Sheet: <br />Customer Approval: <br />#Revision Date <br />Site Name/Location: <br />S: <br />\ <br />Z <br />- <br />P <br />o <br />w <br />e <br />r <br />_ <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br />s <br />\ <br />S <br />C <br />E <br /> <br />- <br /> <br />A <br />L <br />L <br />\ <br />S <br />C <br />E <br />_ <br />C <br />h <br />a <br />r <br />g <br />e <br />- <br />R <br />e <br />a <br />d <br />y <br />_ <br />A <br />L <br />L <br />\ <br />4 <br />4 <br />5 <br />0 <br /> <br />P <br />r <br />c <br />k <br /> <br />R <br />d <br /> <br />E <br />l <br /> <br />M <br />o <br />n <br />t <br />e <br /> <br />H <br />a <br />m <br />p <br />t <br />o <br />n <br /> <br />T <br />e <br />d <br />d <br />e <br />r <br /> <br />1 <br />5 <br />3 <br />5 <br />2 <br />PL <br />O <br />T <br /> <br />D <br />A <br />T <br />E <br />: <br />BY <br />: <br />CG <br />NTS <br />2208-3-15352B <br />SCE CHARGE READY - <br />Hampton Tedder <br />LA County Library <br />4550 Peck Rd <br />El Monte, CA 91732 <br />B1 <br />15352 <br />8/16/22 <br />8/ <br />1 <br />6 <br />/ <br />2 <br />0 <br />2 <br />2 <br /> <br />9 <br />: <br />0 <br />5 <br /> <br />A <br />M <br />CH <br />R <br />I <br />S <br />G <br />A <br />R <br />Z <br />A <br />40/2 <br />SEISMIC COMPLIANCE: <br />DEV MIN. SC RATING: <br />WIRE: <br />PHASE: <br />BUS BRACED: <br />BUS MATERIAL: <br />CURRENT RATING: <br />SERVICE VOLTAGE: <br />FINISH PAINT: <br />CONSTRUCTION: <br />SPECIFICATIONS <br />COMPLIANCE: <br />UL FILE E475911 <br />R <br />EQUIPMENT RATED: <br />UL TYPE 3R OUTDOOR <br />ANSI # 61 LIGHT GRAY, POWDER COATED <br />208Y/120VAC <br />3 PHASE <br />4 WIRE <br />225 Amp <br />PLATED COPPER 1000A PER SQ IN <br />10 KAIC <br />10 KAIC <br />EQUIPMENT SHALL BEAR THE UL 67 LABEL <br />SUITABLE FOR USE AS SERVICE EQUIPMENT <br />OSHPD #OSP-0308-10 <br />INCOMING <br />FROM TSB-EV <br />SINGLE LINE DIAGRAM <br />225/5 <br />MCB <br />32.00 <br />ACCESS <br />FRONT <br />DOOR <br />30.00 <br />PA <br />N <br />E <br />L <br />64.00 <br />32.00 <br />PNL <br />64.00 <br />FRONT ELEVATION <br />SHOWN W/O 3R DOOR <br />FOR CLARITY <br />SECTIONAL <br />SIDE VIEW <br />BASE PLAN <br />ACCESS DOOR <br />32.00 <br />21.88 <br />28.00 <br />CONDUIT <br />AREA <br />28.00 <br />6.13 <br />1.00 <br />30.00 <br />0.75" X 2" <br />ANCHOR HOLES <br />TYP (4) <br />2.38 <br />24.25 <br />2.37 <br />1.00 <br />40/2 <br />40/2 40/2 <br />40/2 40/2 <br />40/2 40/2 <br />40/2 <br />BY: Matt Stiebling, PE <br />SHOP DRAWING / SUBMITTAL REVIEW <br />NO EXCEPTIONS TAKEN <br />MAKE CORRECTIONS NOTED <br />Corrections or comments made relative to submittals during this reviewdo not relieve the contractor from compliance with the drawings andspecifications. This check is only for review of general conformance withthe design concept of the project and general compliance with the <br />information given in the contract document. The contractor is responsible <br />for confirming and correcting all quantities and dimensions; selecting <br />fabrication processes and techniques of construction; coordinating his <br />work with that of other trades and performing his work in a safe and <br />satisfactory manner. <br />REVISE AND RESUBMIT <br />REJECTED <br />DATE: 09/02/2022