Laserfiche WebLink
REF <br />10'-0" CLG HT. <br />(N) BEDROOM #1 <br />(118 SQ. FT.) <br />10'-0" CLG HT. <br />(N) BEDROOM #2 <br />(150 SQ. FT.) <br />(N) BATHROOM <br />(N) CLOSET <br />(N) CLOSET <br />(N) LIVING AREA <br />(N) KITCHEN <br />N (N) ADU FLOOR PLAN <br />W/D <br />10'-0" CLG HT. <br />10'-0" CLG HT. <br />(N) WINDOW SCHEDULE <br />SYMBOLS <br />A <br />DESCRIPTIONSIZE <br />B 3'-0"x3'-0" <br />6'-0"x4'-0" <br />C 2'-8"x1'-4" <br />(N) DOOR SCHEDULE <br />SYMBOLS <br />1 <br />DESCRIPTIONSIZE <br />5'-0"x6'-8"EXTERIOR SOLID CORE DOUBLE DOORS <br />VINYL SLIDER (LOW E) <br />2 <br />VINYL SLIDER (LOW E) <br />VINYL SLIDER (LOW E) <br />U-FACTOR SHGC <br />0.32 0.25 <br />0.32 0.25 <br />0.32 0.25 TEMPERED GLAZED <br />NOTES: <br />TEMPERED GLAZED <br />TEMPERED GLAZED <br />2'-8"x6'-8"INTERIOR HOLLOW DOOR <br />3 7'-0"x6'-8"CLOSET MIRRORED INTERIOR SLIDER DOORS <br />N N) ADU ROOF PLAN <br />4:12 4:12 <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />TVAFCI <br />TV <br />AF <br />C <br />I <br />TV <br />AF <br />C <br />I <br />WP GFCI <br />EXTERIOR HOSE-BIB <br />EXTERIOR HOSE-BIB <br />1 <br />2 <br />2 <br />2 <br />3 <br />3 <br />4 5'-0"x6'-8"EXTERIOR GLASS SLIDER DOOR <br />4 B <br />D <br />AA <br />A <br />C <br />D 5'-0"x3'-0"VINYL SLIDER (LOW E)0.32 0.25 TEMPERED GLAZED <br />7' <br />- <br />1 <br />0 <br />" <br /> <br />x <br /> <br />3 <br />' <br />- <br />0 <br />" <br />CO <br />N <br />C <br />R <br />E <br />T <br />E <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br />E 3'-0"x4'-0"VINYL SLIDER (LOW E)0.32 0.25 TEMPERED GLAZED <br />E <br />EAVE <br />EAVE <br />EAVE <br />EAVEEAVE <br />EAVE <br />EAVE <br />EAVE <br />FR <br />A2.2 <br />22"x30"ATTIC ACCESS <br />EAVE VENT <br />ROOF VENT <br />SHOWER SHALL MAINTAIN A MINIMUM FINISH INTERIOR OF <br />1024 SQ. IN. AND SHALL ALSO BE CAPABLE OF <br />ENCOMPASSING A 30" CIRCLE. <br />FLOOR PLAN KEY NOTES <br />DOOR LANDING MINIMUM 36" DEEP x WIDTH OF DOOR. A <br />DOOR MAY SWING OVER LANDING THAT IS NOT MORE THAN <br />1-1/2" BELOW THE THRESHOLD. (CRC R311.3) FLOOR <br />ELEVATION AT THE REQUIRED EGRESS WITH 1-1/2" OF <br />THRESHOLD. EXCEPTION: AT DOORS OTHER THAN THE MAIN <br />EGRESS DOOR, THE EXTERIOR LANDING OR FLOOR SHALL <br />NOT BE MORE THAN 7-3/4" BELOW THE TOP OF THE <br />THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER <br />THE LANDING OR FLOOR. <br />A MINIMUM RATE OF 725 CFM IS REQUIRED FOR THE KITCHEN <br />EXHAUST VENTILATION. MIN 4" DUCT SIZE SHALL MEET THE <br />MINIMUM REQUIREMENTS OF ASHRA STANDARD 62.2 AND <br />MAXIMUM SOUND RATING OR 3 SONE FOR INTERMITTENT <br />OPERATION (KITCHEN SHALL BE VENTED TO THE OUTSIDE) <br />MINI SPLIT CONDENSERS (2.5 TON) <br />(FOUR ZONE DUCTLESS MINI-SPLIT HEAT PUMP SYSTEM) <br />BATHTUB & SHOWER FLOORS & WALLS ABOVE BATHTUBS WITH <br />INSTALLED SHOWER HEADS & IN SHOWER COMPARTMENTS SHALL <br />BATHROOM & SHOWER NOTES: <br />a.BATHTUB & SHOWER FLOORS & WALLS ABOVE BATHTUBS WITH <br />INSTALLED SHOWER HEADS & IN SHOWER COMPARTMENTS SHALL BE FINISHED <br />WITH NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A <br />HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. CRC R307.2 <br />b. GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT <br />EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. <br />CRC R702.3.8.1 <br />10 <br />0 <br /> <br />A <br />M <br />P <br />SU <br />B <br />- <br />P <br />A <br />N <br />E <br />L <br />TA <br />N <br />K <br />L <br />E <br />S <br />S <br />WA <br />T <br />E <br />R <br /> <br />H <br />E <br />A <br />T <br />E <br />R <br />WP <br /> <br />G <br />F <br />C <br />I <br />5' <br />- <br />0 <br />" <br /> <br />x <br /> <br />3 <br />' <br />- <br />0 <br />" <br />CO <br />N <br />C <br />R <br />E <br />T <br />E <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br />TANKLESS WATER HEATER <br />WILL BE ENCLOSED & PAINTED <br />TO MATCH STRUCTURE <br />CONDENSERMINI-SPLIT <br />FR <br />A2.2 <br />DETAIL DRAWING No. <br />A2.2 <br />SC <br />O <br />P <br />E <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />: <br /> <br />DA <br />T <br />E <br />: <br />1 2 3 <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />SI <br />T <br />E <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DR <br />A <br />W <br />I <br />N <br />G <br />NA <br />M <br />E <br />: <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />OW <br />N <br />E <br />R <br />' <br />S <br /> <br />N <br />A <br />M <br />E <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />AR <br />K <br /> <br />D <br />I <br />S <br />T <br />R <br />I <br />C <br />T <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />S <br />E- <br />M <br />A <br />I <br />L <br />: <br />A <br />R <br />K <br />D <br />I <br />S <br />T <br />R <br />I <br />C <br />T <br />D <br />E <br />S <br />I <br />G <br />N <br />S <br />@ <br />G <br />M <br />A <br />I <br />L <br />. <br />C <br />O <br />M <br />PH <br />: <br /> <br />( <br />3 <br />2 <br />3 <br />) <br /> <br />3 <br />0 <br />4 <br />- <br />5 <br />5 <br />8 <br />1 <br />71 <br />7 <br />1 <br /> <br />W <br />A <br />R <br />N <br />E <br />R <br /> <br />A <br />V <br />E <br />. <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />B <br /> <br /># <br />1 <br />0 <br />5 <br />HU <br />N <br />T <br />I <br />N <br />G <br />T <br />O <br />N <br /> <br />B <br />E <br />A <br />C <br />H <br />, <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />6 <br />4 <br />7 <br />VI <br />C <br />E <br />N <br />T <br />E <br /> <br />M <br />A <br />R <br />Q <br />U <br />E <br />Z <br />(9 <br />4 <br />9 <br />) <br />5 <br />6 <br />6 <br />- <br />7 <br />1 <br />3 <br />1 <br />PRJ.No.:242603 <br />20 <br />6 <br />9 <br />- <br /> <br />2 <br />0 <br />7 <br />1 <br /> <br />S <br />. <br /> <br />E <br />V <br />E <br />R <br />G <br />R <br />E <br />E <br />N <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />& <br /> <br />R <br />E <br />A <br />R <br /> <br />P <br />A <br />T <br />I <br />O <br /> <br />L <br />E <br />G <br />A <br />L <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />FLOOR PLAN NOTES: <br />1. Electrical receptacle outlets, switches, and controls (including controls for heating, ventilation and air conditioning) <br />intended to be used by occupants shall be located no more than 48” measured from the top of the outlet box and not less <br />than 15” measured from the bottom of the outlet box above the finish floor. [CRC R327.1.2] Exceptions: <br />b) Receptacle outlets required by the California Electrical Code on a wall space where the distance between the finished <br />a) Dedicated receptacle outlets; floor receptacle outlets; controls mounted on ceiling fans and ceiling lights; and controls <br />located on appliances. <br />floor and a built-in feature above the finish floor, such as a window, is less than 15 inches (381 mm). <br />2. Effective July 1, 2024, at least one bathroom and one bedroom on the entry level shall provide a doorway with a net clear <br />opening of not less than 32 inches, measured with the door positioned at an angle of 90 degrees from the closed position; <br />or, in the case of a two- or three-story singlefamily dwelling, on the second or third floor of the dwelling if a bathroom or <br />bedroom is not located on the entry level. [CRC R327.1.3] 3. Doorbell buttons or controls, when installed, shall not <br />the top of the doorbell button assembly. Where doorbell buttons integrated with other features are required to be installed <br />above 48 inches measured from the exterior floor or landing, a standard doorbell button or control shall also be provided <br />at a height not exceeding 48 inches above exterior floor or landing, measured from the top of the doorbell button or <br />control. [CRC R327.1.4] <br />3. Doorbell buttons or controls, when installed, shall not exceed 48 inches above exterior floor or landing, measured from <br />ADA NOTES: