My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 N Greenleaf St Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Greenleaf St
>
2017 N Greenleaf St Unit# 2
>
2017 N Greenleaf St Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:56 AM
Creation date
2/13/2026 5:01:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101124083
Full Address
2017 N Greenleaf St Unit# 2
Street Number
2017
Street Direction
N
Street Name
Greenleaf
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(N) <br />SLEEPING <br />AREA <br />(N) <br />BATH <br />SFD <br />GARAGE <br />PL PL PL PL PL PL PL <br />SFD <br />PL PL PL PL PL PL PL <br />(N) KITCHEN AREA <br />18'-11"13'-4" <br />5' <br />- <br />0 <br />" <br />8'-0" <br />13 <br />' <br />- <br />0 <br />" <br />8'-0" <br />5' <br />- <br />4 <br />" <br />40'-11" <br />13 <br />' <br />- <br />0 <br />" <br />HALL <br />18'-0" <br />8' <br />- <br />0 <br />" <br />18'-0" <br />3' <br />- <br />6 <br />" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />6'-0" <br />CLOSET <br />10 <br />' <br />- <br />5 <br />" <br />8' <br />- <br />0 <br />" <br />15" MIN.15" MIN. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />(N) <br />LIVING AREA(N) <br />ENTRY <br />W/D <br />EXISTING UN-PERMITTED PATIO <br />COVER TO BE DEMOLISHED <br />41'-7" <br />13 <br />' <br />- <br />8 <br />" <br />10'-0" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />(N) GAS STOVE <br />(N) GAS DRYER <br />(N) GAS TANKLESS <br />WATERHEATER <br />A <br />A-4 <br />A <br />A-4 <br />B <br />-- <br />(N) DINING AREA <br />2 <br />-- <br />1 <br />-- <br />(N) DUCTLESS <br />MINI-SPLIT HANDLER (N) DUCTLESS <br />MINI-SPLIT HANDLER <br />NOTE: AT LEAST ONE LEAF <br />TO HAVE 32" MIN. CLEAR OPENING <br />PER 2018 IBC SECTION 1010.1.5 EXCEPTION <br />1.1.1: "DOORS SERVING INDIVIDUAL <br />DWELLING UNITS IN GROUPS R-2 AND R-3. A <br />DOOR IS PERMITTED TO OPEN AT THE TOP <br />STEP OF AN INTERIOR FLIGHT OF STAIRS, <br />PROVIDED THAT THE DOOR DOES NOT <br />SWUNG OVER THE TOP STEP. <br />HALL <br />5'-6" <br />(N) LANDING <br />12" THRESHOLD <br />(N) DOOR(N) 2"X4" <br />STUD WALL <br />PER PLAN <br />3'-0" <br />6" <br />11" <br />MAX RISE: 7 34" <br />MIN. RUN: 11" <br />2 <br />2X STUDS @ <br />16" O.C., TYP. <br />58" TYPE "X" <br />GYP. BOARD <br />RESILIENT CHANNEL <br />@ 16" O.C. INSTALL <br /> ON EACH STUD <br />1. THE TYPE AND SPACING OF RESILIENT CHANNELS AND CLIPS <br />AND THE ATTACHENT OF GYPSUM BOARD OR LATH SHALL BE <br />AS REQUIRED FOR FIRE RATINGS. <br />2. THE MINERAL FIBER INSULATION SHALL HAVE ATHERMAL <br />RESISTANCE R VALUE OF 11 OR GREATER AS DETERMINED <br />BY FEDERAL SPECIFICATION RR-I-521B <br />1 HR FIRED / STC 50 WALL ASSEMBLY1 <br />STRUC. I PLY PER PLAN <br />SEE STRUCT. PLANS <br />R-15 INSULATION PER PLAN <br />2X STUDS @ <br />16" O.C., TYP. <br />58" TYPE "X" <br />GYP. BOARD <br />RESILIENT CHANNEL <br />@ 16" O.C. INSTALL <br /> ON EACH STUD <br />78" STUCCO <br />1. THE TYPE AND SPACING OF RESILIENT CHANNELS AND CLIPS <br />AND THE ATTACHENT OF GYPSUM BOARD OR LATH SHALL BE <br />AS REQUIRED FOR FIRE RATINGS. <br />2. THE MINERAL FIBER INSULATION SHALL HAVE ATHERMAL <br />RESISTANCE R VALUE OF 11 OR GREATER AS DETERMINED <br />BY FEDERAL SPECIFICATION RR-I-521B <br />1 HR FIRED / STC 50 WALL ASSEMBLY <br />STRUC. I PLY PER PLAN <br />SEE STRUCT. PLANS <br />R-15 INSULATION PER PLAN <br />58" TYPE "X" <br />GYP. BOARD <br />DR <br />A <br />W <br />I <br />N <br />G <br /> <br />D <br />A <br />T <br />E <br />: <br /> <br />S <br />e <br />p <br /> <br />1 <br />1 <br />, <br /> <br />2 <br />0 <br />2 <br />5 <br /> <br />( <br />1 <br />0 <br />: <br />1 <br />3 <br /> <br />A <br />M <br />) <br />SHEET #: <br />JO <br />B <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />20 <br />1 <br />7 <br /> <br />G <br />R <br />E <br />E <br />N <br />L <br />E <br />A <br />F <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />NO <br />. <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />: <br />DA <br />T <br />E <br />: <br /> <br />B <br />Y <br />: <br />EN <br />G <br />I <br />N <br />E <br />E <br />R <br />: <br />DE <br />S <br />I <br />G <br />N <br />E <br />D <br /> <br />B <br />Y <br />: <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />RE <br />V <br />I <br />E <br />W <br />E <br />D <br /> <br />B <br />Y <br />: <br />PE <br />R <br />M <br />I <br />T <br /> <br />N <br />O <br />. <br />-- <br />C. <br />S <br />. <br />C. <br />S <br />. <br />DE <br />S <br />I <br />G <br />N <br /> <br />G <br />R <br />O <br />U <br />P <br />: <br />ENGINEER OF RECORD: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br />CO <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />I <br />N <br />T <br />O <br />AD <br />U <br />SSDSTA <br />N <br />D <br />L <br />E <br />Y <br /> <br />S <br />T <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />CIVI <br />L <br />- <br /> <br />S <br />T <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />E <br />N <br />G <br />I <br />N <br />E <br />E <br />R <br />S <br />Located at: <br />18757 BURBANK BLVD. UNIT 109 <br />TARZANA, CA 91356 <br />Call: <br />(213) 373-4513 <br />A. <br />G <br />. <br />A. <br />G <br />. <br />A-3 <br />GREEN NOTES <br />1. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS <br />ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH <br />OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. <br />2. FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS <br />LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL <br />INSPECTION <br />3. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, <br />PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT <br />4. THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION <br />APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS <br />SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION <br />5. ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING <br />PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING <br />1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM <br />2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS <br />3. NSF/ANSI 140 AT THE GOLD LEVEL <br />4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE <br />6. 80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE <br />FOLLOWING <br />1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE <br />2. CERTIFIED UNDER UL GREENGUARD GOLD <br />3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE <br />4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS <br />7. THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL <br />J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE <br />WITH ANSI/ACCA 36-S MANUAL S-2004 <br />8. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE <br />SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE <br />SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME <br />9. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION <br />4.303.1 <br />10.THE HOT WATER SYSTEM SHALL NOT ALLOW MORE THAN 0.6 GALLONS OF WATER TO BE DELIVERED TO ANY <br />FIXTURES BEFORE HOT WATER ARRIVES OR SHALL COMPLY WITH EITHER LOS ANGELES PLUMBING CODE <br />SECTION 610.4.1.2 OR 610.4.1.3 <br />#SIZE(WXH)DESCRIPTION REMARKS <br />WINDOW SCHEDULE <br />1 8'-0" x 3'-0" SLIDER XOX <br />#SIZE (WXH)DESCRIPTION REMARKS <br />DOOR SCHEDULE <br />1 SINGLE-HINGED <br />2 3'-0" x 6'-8"SINGLE-HINGED <br />3 6'-0" x 6'-8"FRENCH DOOR <br />MECHANICAL <br />1. GROUND FAULT CIRCUIT-INTERRUPTION (GFCI) FOR PERSONNEL SHALL <br />BE RPOVIDED AND INSTALLED IN READILY ACCESSIBLE AREA <br />2. ARC-FAULT CIRCUIT INTERRUPTION SHALL BE INSTALLED TO PROVIDE <br />PROTECTION OF THE BRANCH CIRCUIT <br />3. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS <br />SPECIFIED IN 210.52, ALL NONLOCKING TYPE 12-VOLT; 15- AND <br />20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT <br />PLUMBING <br />1. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A <br />SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM <br />2. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY <br />TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT <br />AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY <br />3. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A <br />SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED <br />WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL <br />EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR <br />4. PROVIDE ULTRA FLUSH WATER CLOSET FOR ALL NEW CONSTRUCTION, <br />EXISTING SHOWERHEADS AND TOILETS MUST BE ADOPTED FOR LOW <br />WATER CONSUMPTION <br />5. MECHANICAL, ELECTRICAL, AND PLUMBING PLANS ARE NOT REVIEWED <br />AND ARE SUBJECT TO FIELD INSPECTION <br />6. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY <br />WITH THE MAXIMUM FLOW RATES SPECIFIED IN SECTION 4.303.1 <br />EXISTING FLOOR PLAN/DEMO PLAN <br />SHOWING AREA OF WORK SCALE: 1/4"=1'-0" <br />FL <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />S <br />LEGEND: <br />EXISTING WALLS: <br />NEW WALLS: 2X4 @ 16" O.C. <br />(USE 2X6 @ 16" O.C. FOR WALLS > 10'-0" IN HT. <br />WALLS TO REMOVE: <br />SMOKE DETECTOR: (WIRED W/ BATTERY BACK UP) <br />CARBON MONOXIDE ALARM: <br />(HARD-WIRED W/ BATTERY BACKUP) <br />EXHAUST FAN (MIN. 50 CFM) (DUCTED TO OUTSIDE OF <br />BUILDING)(ENERGY STAR W/ HUMIDISTAT) <br />SD <br />CO <br />PROPOSED FLOOR PLAN <br />SHOWING AREA OF WORK SCALE: 1/4"=1'-0" <br />U-FACTOR SHGC <br />0.30 0.23 <br />4 2'-8" x 6'-8"POCKET DOOR <br />2'-8" x 6'-8" <br />3 <br />2 <br />2 <br />TEMPERED <br />SD <br />CO <br />1 HR FIRE RATED EXTERIOR WALL PER DETAIL #1 <br />1 HR FIRE RATED INTERIOR WALL PER DETAIL #2 <br />KITCHEN EXHAUST FAN (MIN. 100 CFM) (DUCTED TO OUTSIDE OF <br />BUILDING)(ENERGY STAR W/ HUMIDISTAT) <br />SD <br />5 8'-0" x 6'-8"FRENCH DOOR 0.30 0.23 <br />5 <br />6 4'-0" x 6'-8"DBL. DOOR <br />NOTE: WINDOWS STYLE, MATERIAL AND COLOR TO <br />MATCH EXISTING SINGLE-FAMILY DWELLING. <br />U-FACTOR SHGC <br />0.230.30 <br />MATERIAL <br />TO MATCH EXISTING <br />SINGLE-FAMILY DWELLING <br />COLOR <br />BLACK <br />SECTION VIEW <br />SHOWING AREA OF WORK SCALE: 3/8"=1'-0"B <br />TEMPERED <br />TEMPERED
The URL can be used to link to this page
Your browser does not support the video tag.