Laserfiche WebLink
(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />4 <br /> <br />G <br />L <br />B <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />4 <br /> <br />G <br />L <br />B <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />4 <br /> <br />G <br />L <br />B <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />4 <br /> <br />G <br />L <br />B <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />7 <br /> <br />G <br />L <br />B <br />, <br /> <br />T <br />Y <br />P <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />7 <br /> <br />G <br />L <br />B <br />, <br /> <br />T <br />Y <br />P <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />7 <br /> <br />G <br />L <br />B <br />, <br /> <br />T <br />Y <br />P <br />(E) 6 3/4x43 1/2 GLB, TYP (E) 6 3/4x30 GLB, TYP (E) 6 3/4x36 GLB, TYP <br />(E) 6 3/4x43 1/2 GLB, TYP (E) 6 3/4x30 GLB, TYP (E) 6 3/4x36 GLB, TYP <br />(E) 4x12 @ 8"OC, TYP(E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP (E) 4x12 @ 8"OC, TYP <br />(E) 2x @ 24"OC. TYP <br />(E) 1/2" PLYWOOD ROOF <br />SHEATHING, VIF <br />RTU <br />8 <br />MAX OP <br />WT=586# <br />RTU <br />2 <br />MAX OP <br />WT=455# <br />RTU <br />13 <br />MAX OP <br />WT=586# <br />1 <br />S2.00TYP <br />(E) DUCT <br />OPENING, TYP <br />(E) UNIT WHERE <br />OCCURS, TYP <br />(E) SCREEN WALL, <br />TYP <br />(NEW) <br />(NEW) <br />(NEW) <br />62 <br />' <br />- <br />0 <br />" <br />± <br />(E <br />) <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />x <br />2 <br />7 <br /> <br />G <br />L <br />B <br />, <br /> <br />T <br />Y <br />P <br />3 <br />4 <br />5 <br />6 <br />7 <br />48 <br />' <br />- <br />0 <br />" <br />± <br /> <br />V <br />I <br />F <br />42 <br />' <br />- <br />0 <br />" <br />± <br /> <br />V <br />I <br />F <br />42 <br />' <br />- <br />0 <br />" <br />± <br /> <br />V <br />I <br />F <br />45 <br />' <br />- <br />0 <br />" <br />± <br /> <br />V <br />I <br />F <br />A B C <br />60'-0"± VIF 60'-0"± VIF <br />SCALE:S2.00 <br />ROOF INFILL AT EXISTING OPENING (WHERE OCCURS)2 <br />1 1/2" = 1'-0" <br />(E) SIMPSON <br />HANGER, TYP VIF <br />(E) OPENING <br />(9'-6" MAX) <br />(E <br />) <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />(4 <br />' <br />- <br />6 <br />" <br /> <br />M <br />A <br />X <br />) <br />NOTE: <br />PROVIDE 10d NAILS @ 6"OC AT ALL (N) PLY <br />EDGES & @ 12"OC EN <br />(E) 2x JOIST PER <br />PLAN, TYP <br />(E) JOIST <br />PER PLAN <br />(E) ROOF <br />SHEATHING <br />PER PLAN <br />(E) SHEATHING (N) SHEATHING <br />EN <br />ROOF <br />SHEATHING <br />PER PLAN <br />SECTION A-A <br />A <br />A <br />2x PER PLAN <br />2x BLKG PER <br />PLAN <br />2x6 @ 24"OC MAX <br />SIMPSON LU26 FACE <br />HANGER EA END, TYP <br />2x6 BLKG W/ (4)-10d <br />NAILS TO (E) JOIST, <br />TYP <br />(E) (2)-2x <br />1/2" STRUC PLY SHTG <br />2x6 BLKG W/ <br />10d NAILS <br />@ 6"OC, TYP <br />SCALE:S2.00 <br />LINE OF SITE 3 <br />NONE <br />6' <br />- <br />0 <br />" <br />300'-0" <br />29 <br />' <br />- <br />0 <br />" <br />62'-0"± <br />4' <br />- <br />7 <br />" <br />MA <br />X <br />SECTION (WHERE SCREEN WALL OCCURS) <br />2' <br />- <br />0 <br />" <br />4' <br />- <br />7 <br />" <br /> <br />M <br />A <br />X <br />NOTE: <br />LINE OF SITE IS ADEQUATE FOR THE <br />NEW UNIT BEING REPLACED THAT IS <br />NOT CURRENTLY BEHIND A SCREEN <br />WALL BASED ON THE EXISTING <br />FIELD DIMENSIONS AS SHOWN. <br />BELOW PARAPET <br />SCALE:S2.00 <br />RTU UNIT ANCHORAGE 1 <br />1/2" = 1'-0" <br />PLAN VIEW AT BASE <br />L2 <br /> <br />M <br />I <br />N <br />W2 MIN <br />L3x3x3/16 x0'-4" LONG W/ (3)-#12 <br />SMS TO UNIT & 1/2"Ø LAG <br />SCREW (3" MIN PEN) TO 4x <br />BELOW, TYP EA CORNER AS <br />SHOWN (4 TOTAL) <br />6" <br />MA <br />X <br />TY <br />P <br />8" <br />MA <br />X <br />H <br />M <br />A <br />X <br />W1±L1± <br />(E) PLYWOOD ROOF <br />SHEATHING PER PLAN <br />(E) 2x JOIST PER <br />PLAN, TYP <br />SIMP A35, SLEEPER TO <br />SLEEPER, EA CORNER <br />(E) 4x MEMBER <br />WHERE OCCURS <br />PER PLAN <br />4x SLEEPER (FIELD <br />VERIFY DEPTH), TYP <br />ALL 4 SIDES <br />1/2" PLYWOOD W/ <br />10d @ 6",6",12 <br />(BN,EN,FN) <br />ANCHOR PER <br />PLAN VIEW, TYP <br />A <br />A <br />RTU UNIT PER PLAN, <br />MAX OP WT=SEE SCHED <br />SIMP A34, TYP <br />EA SIDE, EA END <br />2 3/4" MIN <br />8" MAX <br />TYP <br />2" <br />TYP <br />4x6 BLKG W/ SIMP A35 <br />EA SIDE, EA END, TYP <br />AT SLEEPER ANGLES <br />4x6 W/ SIMP A34 EA <br />SIDE, EA END, TYP AT <br />ANGLES AS SHOWN <br />2x6 @ 16"OC W/ <br />SIMP A34 EA SIDE, <br />EA END, TYP UNO <br />L3x3x12GA x0'-6" BENT PL W/ <br />(2)-1/2"Ø LAG SCREWS (3" MIN <br />PEN) TO SLEEPER & (2)-1/2"Ø <br />LAG SCREWS (4" MIN PEN) TO <br />4x BLOCK, TYP EA END OF <br />SLEEPER AS SHOWN <br />SECTION A-A <br />8'-0" MAX <br />TYP <br />EQ <br />TYP EQ <br />TYP <br />EQ TYP <br />NEOPRENE PAD PER MECH, <br />TYP UNDER EA ANCHOR <br />(E) GLB WHERE <br />OCCURS PER PLAN <br />EQUIPMENT SCHEDULE <br />UNIT MAX OP WT H W1 L1 W2 L2 <br />RTU-2 455#49"44"48"47"36" <br />RTU-8, 13 586#34"46"74"49"62" <br />SCALE:S2.00 <br />ROOF INFILL AT EXISTING OPENING (WHERE OCCURS)2 <br />1 1/2" = 1'-0" <br />(E) SIMPSON <br />HANGER, TYP VIF <br />(E) OPENING <br />(9'-6" MAX) <br />(E <br />) <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />(4 <br />' <br />- <br />6 <br />" <br /> <br />M <br />A <br />X <br />) <br />NOTE: <br />PROVIDE 10d NAILS @ 6"OC AT ALL (N) PLY <br />EDGES & @ 12"OC EN <br />(E) 2x JOIST PER <br />PLAN, TYP <br />(E) JOIST <br />PER PLAN <br />(E) ROOF <br />SHEATHING <br />PER PLAN <br />(E) SHEATHING (N) SHEATHING <br />EN <br />ROOF <br />SHEATHING <br />PER PLAN <br />SECTION A-A <br />A <br />A <br />2x PER PLAN <br />2x BLKG PER <br />PLAN <br />2x6 @ 24"OC MAX <br />SIMPSON LU26 FACE <br />HANGER EA END, TYP <br />2x6 BLKG W/ (4)-10d <br />NAILS TO (E) JOIST, <br />TYP <br />(E) (2)-2x <br />1/2" STRUC PLY SHTG <br />2x6 BLKG W/ <br />10d NAILS <br />@ 6"OC, TYP <br />SCALE:S2.00 <br />LINE OF SITE 3 <br />NONE <br />6' <br />- <br />0 <br />" <br />300'-0" <br />29 <br />' <br />- <br />0 <br />" <br />62'-0"± <br />4' <br />- <br />7 <br />" <br />MA <br />X <br />SECTION (WHERE SCREEN WALL OCCURS) <br />2' <br />- <br />0 <br />" <br />4' <br />- <br />7 <br />" <br /> <br />M <br />A <br />X <br />NOTE: <br />LINE OF SITE IS ADEQUATE FOR THE <br />NEW UNIT BEING REPLACED THAT IS <br />NOT CURRENTLY BEHIND A SCREEN <br />WALL BASED ON THE EXISTING <br />FIELD DIMENSIONS AS SHOWN. <br />BELOW PARAPET <br />SCALE:S2.00 <br />RTU UNIT ANCHORAGE 1 <br />1/2" = 1'-0" <br />PLAN VIEW AT BASE <br />L2 <br /> <br />M <br />I <br />N <br />W2 MIN <br />L3x3x3/16 x0'-4" LONG W/ (3)-#12 <br />SMS TO UNIT & 1/2"Ø LAG <br />SCREW (3" MIN PEN) TO 4x <br />BELOW, TYP EA CORNER AS <br />SHOWN (4 TOTAL) <br />6" <br />MA <br />X <br />TY <br />P <br />8" <br />MA <br />X <br />H <br />M <br />A <br />X <br />W1±L1± <br />(E) PLYWOOD ROOF <br />SHEATHING PER PLAN <br />(E) 2x JOIST PER <br />PLAN, TYP <br />SIMP A35, SLEEPER TO <br />SLEEPER, EA CORNER <br />(E) 4x MEMBER <br />WHERE OCCURS <br />PER PLAN <br />4x SLEEPER (FIELD <br />VERIFY DEPTH), TYP <br />ALL 4 SIDES <br />1/2" PLYWOOD W/ <br />10d @ 6",6",12 <br />(BN,EN,FN) <br />ANCHOR PER <br />PLAN VIEW, TYP <br />A <br />A <br />RTU UNIT PER PLAN, <br />MAX OP WT=SEE SCHED <br />SIMP A34, TYP <br />EA SIDE, EA END <br />2 3/4" MIN <br />8" MAX <br />TYP <br />2" <br />TYP <br />4x6 BLKG W/ SIMP A35 <br />EA SIDE, EA END, TYP <br />AT SLEEPER ANGLES <br />4x6 W/ SIMP A34 EA <br />SIDE, EA END, TYP AT <br />ANGLES AS SHOWN <br />2x6 @ 16"OC W/ <br />SIMP A34 EA SIDE, <br />EA END, TYP UNO <br />L3x3x12GA x0'-6" BENT PL W/ <br />(2)-1/2"Ø LAG SCREWS (3" MIN <br />PEN) TO SLEEPER & (2)-1/2"Ø <br />LAG SCREWS (4" MIN PEN) TO <br />4x BLOCK, TYP EA END OF <br />SLEEPER AS SHOWN <br />SECTION A-A <br />8'-0" MAX <br />TYP <br />EQ <br />TYP EQ <br />TYP <br />EQ TYP <br />NEOPRENE PAD PER MECH, <br />TYP UNDER EA ANCHOR <br />(E) GLB WHERE <br />OCCURS PER PLAN <br />EQUIPMENT SCHEDULE <br />UNIT MAX OP WT H W1 L1 W2 L2 <br />RTU-2 455#49"44"48"47"36" <br />RTU-8, 13 586#34"46"74"49"62" <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />E <br />N <br />G <br />I <br />N <br />E <br />E <br />R <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />N <br />F <br />O <br />R <br />M <br />A <br />T <br />I <br />O <br />N <br />RTU Unit <br />Replacement <br />1951 Carnegie Ave <br />Santa Ana, <br />CA, 92705 <br />24-0417-00 <br />SH <br />E <br />E <br />T <br /> <br />N <br />U <br />M <br />B <br />E <br />R <br />SH <br />E <br />E <br />T <br /> <br />T <br />I <br />T <br />L <br />E <br />SH <br />E <br />E <br />T <br /> <br />I <br />N <br />F <br />O <br />JOB NUMBER: <br />DRAWN: <br />DESIGNED: <br />CHECKED: <br />ST <br />A <br />M <br />P <br />AP <br />P <br />R <br />O <br />V <br />A <br />L <br />RR <br />GD <br />RLB <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />S <br /> <br />A <br />N <br />D <br /> <br />R <br />E <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />ISSUE DATE: <br />NO DATEDESCRIPTION <br />SCALE: <br />H: <br />\ <br />2 <br />0 <br />2 <br />4 <br />\ <br />2 <br />4 <br />0 <br />4 <br />1 <br />7 <br />\ <br />3 <br />_ <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />D <br />w <br />g <br />s <br />- <br />0 <br />0 <br />\ <br />2 <br />4 <br />- <br />0 <br />4 <br />1 <br />7 <br />- <br />0 <br />0 <br />_ <br />S <br />2 <br />. <br />0 <br />0 <br /> <br />P <br />A <br />R <br />T <br />I <br />A <br />L <br /> <br />R <br />O <br />O <br />F <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br /> <br />P <br />L <br />A <br />N <br />, <br /> <br />S <br />E <br />C <br />T <br />I <br />O <br />N <br />S <br />, <br /> <br />A <br />N <br />D <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S <br />. <br />d <br />w <br />g <br /> <br /> <br /> <br /> <br />P <br />L <br />O <br />T <br />T <br />E <br />D <br /> <br />B <br />Y <br />: <br /> <br /> <br />Ru <br />b <br />e <br />n <br /> <br />R <br />u <br />i <br />z <br /> <br /> <br /> <br /> <br />O <br />N <br />: <br /> <br /> <br />Fe <br />b <br />r <br />u <br />a <br />r <br />y <br /> <br />5 <br />, <br /> <br />2 <br />0 <br />2 <br />5 <br />10-14-2024 <br />S2.00 <br />PARTIAL ROOF <br />FRAMING PLAN, <br />SECTIONS, AND <br />DETAILS <br />AS NOTED <br />LONG BEACH • SAN DIEGO <br />LONG BEACH OFFICE <br />3900 Cover Street, Long Beach <br />CA 90808 • 562.985.3200 <br />S T R U C T U R A L E N G I N SREE <br />No.3503 <br />L <br />I <br />GNE <br />L <br />S NO <br />B A <br />LAE <br />A L I OFRNIA <br />N <br />E <br />ER <br />I <br />E <br />ET <br />ORPD <br />F E <br />R IR <br />L.KC <br />E <br />TS <br />AT <br />CFO <br />RE <br />G <br />S <br />I <br />S <br />URALTSRUCTPRO <br />G <br />R <br />E <br />S <br />S <br /> <br />- <br />NO <br />T <br /> <br />F <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />REV <br />I <br />E <br />W <br />SCALE:S2.00 <br />PARTIAL ROOF FRAMING PLAN A <br />1/8" = 1'-0" <br />1.SEE GENERAL NOTES SHEET(S) FOR APPLICABLE NOTES & <br />ABBREVIATIONS. SEE PROJECT SPECIFICATIONS WHERE <br />APPLICABLE FOR ADDITIONAL INFORMATION. <br />2.EXISTING CONSTRUCTION IS SHOWN FADED AND IS LABELED <br />AS EXISTING OR (E). NEW CONSTRUCTION IS SHOWN DARK AND <br />IS SPECIFICALLY REFERENCED BY DETAILS AND NOTES. <br />3.EXISTING CONDITIONS ARE SHOWN TO THE BEST OF OUR <br />KNOWLEDGE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING <br />ACTUAL CONDITIONS. DISCREPANCIES BETWEEN ACTUAL FIELD <br />CONDITIONS AND THOSE SHOWN ON THESE DRAWINGS SHALL <br />BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO <br />PROCEEDING. <br />4.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS <br />SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED <br />WITH ACTUAL EQUIPMENT TO BE INSTALLED. <br />5.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF <br />ALL EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO <br />INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO <br />NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS <br />PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND <br />AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. <br />6.DO NOT CUT ANY NEW OPENINGS OR ENLARGE ANY EXISTING <br />OPENINGS IN THE ROOF OR WALLS (FOR DUCTS, PIPES, ETC.) <br />UNLESS SPECIFICALLY SHOWN ON THESE STRUCTURAL <br />DRAWINGS. <br />7.MAXIMUM OPERATING WEIGHTS NOTED ON THE PLANS INCLUDE <br />THE WEIGHT OF UNIT PLUS ALL ACCESSORIES, CURBS, <br />ISOLATORS, ETC. THAT ARE ASSOCIATED WITH THE UNIT. <br />FRAMING PLAN NOTES <br />No.3503 <br />L <br />I <br />GNE <br />L <br />S NO <br />B A <br />LAE <br />A L I OFRNIA <br />N <br />E <br />ER <br />I <br />E <br />ET <br />ORPD <br />F E <br />R IR <br />L.KC <br />E <br />TS <br />AT <br />CFO <br />RE <br />G <br />S <br />I <br />S <br />URALTSRUCT <br />Exp. 3/31/2026