|
UNIFORM AND POINT LOAD ON CONTINUOUS FOOTING
<br />Footing Width (FW) =
<br />Footing Depth (FD) =
<br />Soil Bearing (SB) =
<br />Max . Soil Bearing =
<br />Plain Concrete Design:
<br />F'c=
<br />Tension Fb =
<br />Procedures :
<br />12 in
<br />12 in
<br />1 ,500 psf
<br />1,500 psf
<br />2 ,500 psi
<br />80 psi
<br />Fsoil = ((D-FD)/12*1D)+SB
<br />F'soil = Fsoii-(D/12*(150-110))
<br />w = W*F'soi l/12
<br />w (")
<br />12 X
<br />12 X
<br />15 X
<br />18 X
<br />21 X
<br />24 X
<br />12 X
<br />15 X
<br />18 X
<br />21 X
<br />24 X
<br />12 X
<br />15 X
<br />18 X
<br />21 X
<br />24 X
<br />12 X
<br />15 X
<br />18 X
<br />21 X
<br />24 X
<br />12 X
<br />15 X
<br />18 X
<br />21 X
<br />24 X
<br />30 X
<br />M = Fb *W*d"2/12"/6
<br />L = (2*M/w)"1/2
<br />Pmax = 2*L*w
<br />D (") Fsoil (psf) F'soil (psf)
<br />5 1 ,500 1,483
<br />12 1,500 1 ,460
<br />12 1 500 1,460
<br />12 1,500 1,460
<br />12 1,500 1,460
<br />12 1 ,500 1 ,460
<br />15 1,500 1,450
<br />15 1,500 1,450
<br />15 1,500 1 ,450
<br />15 1 ,500 1,450
<br />15 1,500 1,450
<br />18 1,500 1 ,440
<br />18 1,500 1,440
<br />18 1,500 1,440
<br />18 1,500 1,440
<br />18 1,500 1,440
<br />21 1 ,500 1,430
<br />21 1,500 1,430
<br />21 1,500 1,430
<br />21 1,500 1,430
<br />21 1,500 1,430
<br />24 1 ,500 1,420
<br />24 1,500 1,420
<br />24 1,500 1,420
<br />24 1,500 1,420
<br />24 1,500 1,420
<br />24 1,500 1,420
<br />Soil Density =
<br />Concrete Density=
<br />Inc. Width (IW) =
<br />Inc. Depth (ID) =
<br />w (#/ft} M ('#)
<br />1,483 333
<br />1 ,460 1,920
<br />1 ,825 2,400
<br />2,190 2 ,880
<br />2 ,555 3 360
<br />2 ,920 3 ,840
<br />1,450 3 ,000
<br />1,813 3 ,750
<br />2 ,175 4 ,500
<br />2 ,538 5 ,250
<br />2 ,900 6,000
<br />1,440 4 ,320
<br />1,800 5 ,400
<br />2,160 6,480
<br />2 ,520 7 ,560
<br />2,880 8 ,640
<br />1,430 5 ,880
<br />1,788 7 ,350
<br />2 ,145 8 ,820
<br />2 ,503 10,290
<br />2 ,860 11,760
<br />1,420 7 680
<br />1 ,775 9 ,600
<br />2 ,130 11 ,520
<br />2,485 13,440
<br />2 ,840 15 ,360
<br />3 ,550 19 ,200
<br />110 pcf
<br />150 pcf
<br />0 psf
<br />0 psf
<br />L (ft) Pmax (#}
<br />0 .67 1,989
<br />1.62 4 ,736
<br />1.62 5,919
<br />1.62 7 ,103
<br />1.62 8,287
<br />1.62 9 ,471
<br />2 .03 5 ,899
<br />2 .03 7 ,374
<br />2 .03 8,849
<br />2 .03 10,324
<br />2 .03 11,7~
<br />2.45 /7,05~
<br />2.45 ~18
<br />2.45 10 ,582
<br />2.45 12 ,345
<br />2.45 14,109
<br />2 .87 8 ,202
<br />2.87 10,252
<br />2 .87 12 ,302
<br />2.87 14 ,353
<br />2.87 16 ,403
<br />3.29 9 ,340
<br />3 .29 11 ,676
<br />3 .29 14 ,011
<br />3 .29 16,346
<br />3 .29 18 ,681
<br />3.29 23,351
<br />Note: For point loads on footings with uniform loads , take the difference
<br />between "w" above and the uniform load , then multiply by two and by
<br />"L" above for P'max .
|