Laserfiche WebLink
PROJECT Air Liquide <br />FOR Modula <br /> SHEET NO.2 <br />CALCULATED BY RF <br />DATE 2/27/2023 <br />SCOPE: <br />The purpose of this analysis is to ensure that the slab complies with the specifications set forth in the <br />2022 CBC. The base slab will be analyzed with respect to the most critical configuration and forces <br />resulting from both static and seismic forces. <br />PARAMETERS: <br />THE VERTICAL LIFT MODULES CONSIST OF TRAYS AND ROTARY MOTORS THAT TRANSPORT MATERIAL TO AN <br />OPERATOR WORKSTATION OPENING. <br />DL =12,333 LB <br />PL =49,612 LB <br />FULL LOADED =61,945 LB <br /> THE ANCHORS WILL BE JUSTIFIED TO RESIST UPLIFT AND SHEAR. <br />Fa =1.00 <br />Ss =1.267 <br />CODE -2022 CBC <br />SPECIFICATIONS: <br />-FIXTURE ML50 - 7100 <br />-ANCHORS 5/8"Ø Hilti KB TZ2 x 3-3/4" embedment MIN. EMBED. <br />(ESR - 4266) <br />-SLAB 5.5 IN x 3000 PSI <br />-SOIL Soil Bearing Pressure 1000 psf <br />Modulus Of Subgrade Reaction 50 pci <br />Note :Two L4x4x1/2 angle bolt to the column, one anchor per angle <br />MATERIAL HANDLING ENGINEERING <br />TEL: (909) 869-0989 / FAX: (909) 869-0981 <br />INC. <br />SEIZMIC