1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING <br />CONSTRUCTION. THE CITY OF SANTA ANA AND STRUCTURAL ENGINEER <br />SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. <br />2. ALL DRAWINGS ARE CONSIDERED TO BE A PART OF THE CONTRACT <br />DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW <br />AND COORDINATION OF ALL DRAWINGS AND SPECIFICATIONS PRIOR TO THE <br />START OF CONSTRUCTION. ANY DISCREPANCIES THAT OCCUR SHALL BE <br />BROUGHT TO THE ATTENTION OF THE CITY OF SANTA ANA AND <br />STRUCTURAL ENGINEER PRIOR TO START OF CONSTRUCTION SO THAT A <br />CLARIFICATION CAN BE ISSUED. ANY WORK PERFORMED IN CONFLICT WITH <br />THE CONTRACT DOCUMENTS OR ANY CODE REQUIREMENTS SHALL BE <br />CORRECTED BY THE CONTRACTOR AT THEIR OWN EXPENSE AND AT NO <br />EXPENSE TO THE OWNER OR STRUCTURAL ENGINEER. <br />3. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER <br />GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, <br />CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. <br />4. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT <br />THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH <br />MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING <br />FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION <br />VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE <br />INSPECTION OF THE ABOVE ITEMS. <br />5. ASTM SPECIFICATIONS ON THE DRAWINGS SHALL BE OF THE LATEST <br />REVISION. <br />6. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IF PLACED ON FRAMED <br />ROOF OR FLOOR. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER <br />SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE <br />STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. <br />7. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE THAT OCCURS DUE <br />TO NOT FULLY LOCATING EXISTING UTILITIES. <br />8. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING <br />CONDITIONS IS BASED ON AVAILABLE KNOWLEDGE OF EXISTING <br />STRUCTURE. CONTRACTOR SHALL VERIFY IN FIELD ALL EXISTING <br />CONDITIONS RELATIVE TO THE SCOPE OF THIS PROJECT. WHERE ACTUAL <br />CONDITIONS ARE NOT IN ACCORDANCE WITH THE DRAWINGS PROVIDED, <br />THE CITY OF SANTA ANA AND STRUCTURAL ENGINEER SHALL BE NOTIFIED <br />IMMEDIATELY. CONTRACTOR SHALL ALIGN FOR SUFFICIENT BUDGET AND <br />SCHEDULE CONTINGENCY TO ADDRESS EXISTING HIDDEN CONDITIONS. <br />9. ALL DEMOLITION SHALL BE PERFORMED IN SUCH A WAY AS NOT TO <br />DAMAGE THE EXISTING STRUCTURAL ELEMENTS THAT ARE TO REMAIN IN <br />THE FINISHED STRUCTURE. ANY PORTIONS OF STRUCTURE TO REMAIN <br />THAT ARE DAMAGED DURING DEMOLITION SHALL BE REPLACED AT NO <br />ADDITIONAL COST. EXISTING STRUCTURAL ELEMENTS SHALL BE <br />PROTECTED TO THE FULLEST EXTENT POSSIBLE, IN ORDER TO MITIGATE <br />DAMAGE. CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND <br />REPLACEMENT OF ALL EXISTING STRUCTURAL ELEMENTS THAT ARE <br />NECESSARY FOR THE COMPLETION OF ALL NEW WORK. <br />1. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE <br />FOLLOWING CODES: <br />2022 CALIFORNIA BUILDING CODE AND LATEST REVISIONS <br />REFERRED TO HERE AS "THE CODE", AND ANY OTHER REGULATING <br />AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK, <br />INCLUDING THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, AND <br />THOSE CODES & STANDARDS LISTED IN THESE NOTES AND SPECIFICATIONS. <br />2. DESIGN LOADS: <br />LIVE LOADS: <br />ROOF 20 PSF REDUCIBLE <br />KPFF WILL PROVIDE STRUCTURAL OBSERVATION SERVICES AS DEFINED IN THE <br />CODE. SITE VISIT REPORTS WILL BE SUBMITTED IN WRITING TO THE OWNER'S <br />REPRESENTATIVE, SPECIAL INSPECTOR AND THE BUILDING OFFICIAL. PERIODIC <br />STRUCTURAL OBSERVATIONS WILL BE MADE AT SIGNIFICANT CONSTRUCTION <br />STAGES AS DEFINED BELOW. THE STRUCTURAL OBSERVATION WILL CONSIST OF <br />A VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM FOR GENERAL <br />CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL <br />OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE <br />INSPECTIONS REQUIRED BY THE CODE. THE CONTRACTOR SHALL PROVIDE KPFF <br />WITH A CONSTRUCTION SCHEDULE AND (5) WORKING DAYS NOTICE SO THAT <br />THE OBSERVATION VISITS CAN BE PLANNED IN ADVANCED. <br />SITE VISITS <br />1. CONTRACTOR SHALL NOTIFY STRUCTURAL ENGINEER FIVE (5) WORKING <br />DAYS PRIOR TO THE FOLLOWING CONSTRUCTION MILESTONES: <br />PLYWOOD ROOF DIAPHRAGM FRAMING: <br />AFTER PLACEMENT OF NAILING AND/OR SCREWS, TENSION TIES AND <br />STRAPS PRIOR TO PLACING OF ROOFING MATERIAL. <br />2. FAILURE TO NOTIFY THE CITY OF SANTA ANA/ENGINEER OF ANY <br />CONSTRUCTION MILESTONES MAY RESULT IN CONTRACTOR HAVING TO <br />REMOVE WORK FOR THE PURPOSE OF REVIEW AT THE CONTRACTOR'S <br />EXPENSE. <br />1. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR, VISUALLY GRADED OR <br />MACHINE GRADED UNDER THE STANDARD GRADING RULES, NO. 17 OF THE <br />WEST COAST LUMBER INSPECTION BUREAU. ALL FRAMING MEMBERS SHALL <br />BE AS FOLLOWS: <br />USE GRADE <br />2x4 TOP PLATES DF STUD <br />2x4 STUDS ( ≤ 10'-0"), 2x4 BLOCKING DF STUD <br />2x4 STUDS ( > 10'-0") DF NO. 2 <br />2x6 TOP PLATES DF NO. 2 <br />2x6 STUDS ( ≤ 10'-0"), 2x6 BLOCKING DF STUD <br />2x6 STUDS ( > 10'-0") DF NO. 2 <br />6x BEAMS AND POST DF NO. 1 <br />ALL OTHER SAWN LUMBER DF NO. 2 <br />2. ALL NEW WOOD BEARING ON CONCRETE OR MASONRY IN DIRECT CONTACT <br />WITH EARTH SHALL BE PRESSURE TREATED DOUGLAS FIR IN ACCORDANCE <br />WITH CODE SECTION 2303.1.9 AND 2304.12. ALL CUTS, HOLES & NOTCHES BE <br />TREATED WITH A PRESERVATIVE APPROVED BY THE STRUCTURAL <br />ENGINEER. <br />3. FASTENERS FOR PRESSURE-PRESERVATIVE TREATED WOOD SHALL BE HOT- <br />DIPPED ZINC COATED GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR <br />COPPER PER CODE SECTION 2304.10.5. <br />4. ALL STRUCTURAL PLYWOOD SHEATHING SHALL BE DOUGLAS FIR STANDARD <br />GRADE STRUCTURAL I WITH EXTERIOR GLUE CONFORMING TO THE LATEST <br />EDITION OF PS 1 UNO. ALL STRUCTURAL COMPOSITE SHEATHING SHALL BE <br />DOUGLAS FIR STANDARD GRADE STRUCTURAL I WITH EXTERIOR GLUE <br />CONFORMING TO THE LATEST EDITION OF PS 2 UNO. ALL PANELS SHALL <br />BEAR LEGIBLE DFPA STAMPS. <br />5. ALL ROOF SHEATHING SHALL BE LAID FACE GRAIN PERPENDICULAR TO <br />FRAMING UNO. ALL SHEATHING SHALL BE APPROVED BY THE BUILDING <br />INSPECTOR BEFORE COVERING. <br />6. UNLESS NOTED OTHERWISE, ALL WOOD SILL PLATE UNDER BEARING, <br />EXTERIOR, OR SHEAR WALLS IN CONTACT WITH CONCRETE OR MASONRY <br />SHALL BE BOLTED TO CONCRETE OR MASONRY WITH 5/8"Ø ANCHOR RODS <br />W/ 7" MIN CONCRETE/MASONRY EMBED AT 6'-0" OC FOR STRUCTURES TWO <br />STORIES OR LESS AND 4'-0" OC FOR STRUCTURES OVER TWO STORIES IN <br />HEIGHT BEGINNING AT 4" MIN AND 12" MAX FROM EACH END OF THE PLATES. <br />7. ALL BOLT HEADS AND NUTS WHICH BEAR AGAINST THE FACE OF WOOD <br />MEMBERS SHALL BE PROVIDED WITH 2"x2"x3/16" STEEL PLATE WASHERS <br />UNO. ALL ANCHOR BOLTS FOR SHEAR WALLS SHALL BE PROVIDED WITH A <br />3"x3"x0.229" MIN STEEL PLATE WASHER UNLESS NOTED OTHERWISE. <br />8. ALL NAILS FOR CONNECTING WOOD MEMBERS SHALL BE COMMON NAILS. <br />MINIMUM NAILING REQUIREMENTS OUTLINED IN TABLE 2304.10.1 SHALL BE <br />FOLLOWED UNLESS NOTED OTHERWISE. <br />9. RETIGHTEN BOLTS BEFORE CLOSING-IN. <br />10. USE OF MACHINE NAILING IS SUBJECT TO A SATISFACTORY JOBSITE <br />DEMONSTRATION FOR EACH PROJECT AND THE APPROVAL BY THE <br />STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT. THE APPROVAL IS <br />SUBJECT TO CONTINUED SATISFACTORY PERFORMANCE. MACHINE NAILING <br />WILL NOT BE APPROVED IN 5/16" SHEATHING. IF NAIL HEADS PENETRATE THE <br />OUTER PLY MORE THAN WOULD BE NORMAL FOR A HAND HAMMER OR IF <br />MINIMUM ALLOWABLE EDGE DISTANCES ARE NOT MAINTAINED, THE <br />PERFORMANCE WILL BE DEEMED UNSATISFACTORY. <br />11. ALL WOOD HARDWARE CONNECTORS SHALL BE SIMPSON STRONG-TIE <br />UNLESS NOTED OTHERWISE. <br />12. PROVIDE FULL DEPTH BLOCKING AT 4'-0" OC BETWEEN ADJACENT JOISTS <br />UNDER ALL PERPENDICULAR PARTITIONS. PROVIDE DOUBLE JOIST UNDER <br />ALL PARALLEL PARTITIONS UNLESS NOTED OTHERWISE. <br />13. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, CONDUIT, ETC. <br />UNLESS SPECIFICALLY NOTED OR DETAILED FOR SUCH ALTERATIONS. <br />14. ROOF SHEATHING SHALL BE INSPECTED PRIOR TO PLACING INSULATION AND <br />ROOFING. <br />15. SOLID BLOCKING (2x MIN) SHALL BE PLACED BETWEEN JOISTS OR RAFTERS <br />AT ALL SUPPORTS. <br />16. ALL ANCHOR RODS SHALL CONFORM TO ASTM F1554. ALL BOLTS SHALL <br />CONFORM TO ASTM A307. <br />17. HOLES FOR BOLTS SHALL BE BORED 1/32" TO 1/16" LARGER THAN NOMINAL <br />BOLT DIAMETER. (THIS INCLUDES HOLES FOR ANCHOR RODS IN SILL PLATE). <br />18. JOIST CONNECTIONS SHALL BE SIMPSON 'LUS' UNLESS NOTED OTHERWISE. <br />19. ALL POST CONNECTIONS LOCATED DIRECTLY ON CONCRETE SHALL BE <br />SIMPSON 'CB' UNLESS NOTED OTHERWISE. <br />20. FILL ALL NAIL HOLES OF WOOD CONNECTION HARDWARE (STRAPS, <br />HANGERS, ETC.). <br />1. THE MANUFACTURE AND FABRICATION OF STRUCTURAL GLUE-LAMINATED <br />TIMBER SHALL BE IN CONFORMANCE WITH THE CURRENT EDITION OF THE <br />AMERICAN NATIONAL STANDARD / AMERICAN INSTITUTE OF TIMBER <br />CONSTRUCTION "STRUCTURAL GLUE LAMINATED TIMBER" (ANSI/AITC A190.1). <br />2. ALL GLUE-LAMINATED MEMBERS SHALL BE DOUGLAS FIR COMBINATION <br />24F-V4. ALLOWABLE STRESS REQUIREMENTS ARE AS FOLLOWS: <br />Fbxx = 2400 PSI (TENSION IN TENSION ZONE) <br />= 1850 PSI (TENSION IN COMPRESSION ZONE) <br />Fc┴= 650 PSI <br />Fc//= 1650 PSI <br />Fv = 265 PSI <br />Exx = 1.8x 106/ <br />3. THE MANUFACTURER SHALL SUBMIT COMPLETE SHOP DRAWINGS TO THE <br />ARCHITECT/ ENGINEER FOR APPROVAL PRIOR TO ANY FABRICATION. <br />4. PROVIDE CAMBERS AS NOTED ON THE DRAWINGS. <br />5. TEMPERATURE OF GLUE-LAMINATED TIMBER IS NOT TO EXCEED 150°F IN <br />SERVICE. <br />6. GLUE-LAMINATED MEMBERS SHOWN ON THESE PLANS ARE FOR DRY <br />CONDITIONS OF USE. WHERE GLUE-LAMINATED MEMBERS ARE EXPOSED TO <br />WEATHER, THE EXPOSED MEMBERS SHALL BE PRIMED AND PAINTED. <br />7. GLB CONNECTIONS SHALL BE SIMPSON 'HGLT, HGLS' UNLESS NOTED <br />OTHERWISE. EXTERIOR CONNECTIONS SHALL BE STAINLESS STEEL, HOT <br />DIPPED GALVANIZED, OR PRIMED AND PAINTED. <br />1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED <br />BY AN APPROVED AND LICENSED FABRICATOR IN ACCORDANCE WITH <br />THE AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS <br />(LATEST EDITION), AND WITH CHAPTERS 17 AND 22 OF THE CODE. <br />2. ALL STRUCTURAL STEEL SHALL CONFORM TO THE ASTM <br />DESIGNATION AS INDICATED BELOW (UNO): <br />ANGLES, CHANNELS, PLATES, BARS, <br />CONNECTION PLATES, AND MISC A36 <br />BOLTS F3125, GRADE A325 <br />TWIST-OFF TYPE BOLTS F3125, GRADE F1852 <br />3. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP <br />DRAWINGS OF ALL STEEL TO THE CITY OF SANTA ANA AND <br />STRUCTURAL ENGINEER'S REVIEW AND APPROVAL BEFORE <br />FABRICATION. <br />4. BOLT HOLES USED IN STEEL SHALL BE 1/16" LARGER IN DIAMETER <br />THAN NOMINAL SIZE OF BOLT USED, EXCEPT AS NOTED. <br />5. ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN <br />CONCRETE, MASONRY OR SPRAY ON FIREPROOFING, OR ARE <br />ENCASED BY BUILDING FINISH, SHALL BE LEFT UNPAINTED. <br />6. ALL WELDING IS TO BE DONE BY CERTIFIED WELDERS USING FILLER <br />METALS TO MATCH MATERIAL STRENGTH (UNO). ALL WELDS SHALL <br />BE IN CONFORMITY WITH THE PROJECT SPECIFICATIONS AND THE <br />CODE FOR WELDING IN BUILDING CONSTRUCTION (AWS D1.1 LATEST <br />REVISION) OF THE AMERICAN WELDING SOCIETY. SEE SPECIAL <br />INSPECTIONS SECTION FOR WELDING INSPECTION REQUIREMENTS. <br />USE OF E70T-4 WIRE IS NOT PERMITTED. <br />7. WHERE FABRICATION OF STRUCTURAL, LOAD-BEARING OR LATERAL <br />LOAD-RESISTING MEMBERS OR ASSEMBLIES IS BEING CONDUCTED <br />ON THE PREMISES OF FABRICATOR'S SHOP, SPECIAL INSPECTION OF <br />THE FABRICATED ITEMS SHALL BE PERFORMED DURING FABRICATION, <br />EXCEPT WHERE THE FABRICATOR HAS BEEN APPROVED TO <br />PERFORM WORK WITHOUT SPECIAL INSPECTIONS IN ACCORDANCE <br />WITH SECTION 1704.2.5.1 OF THE CODE. <br />8. WELD LENGTHS CALLED FOR ON PLANS ARE THE NET EFFECTIVE <br />LENGTH REQUIRED. WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT <br />INDICATION OF SIZE, USE MINIMUM SIZE WELDS AS SPECIFIED IN AISC <br />360-16 SECTION J2.2b. <br />9. ALL EXPOSED STRUCTURAL STEEL AND MISCELLANEOUS METAL <br />SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. <br />10. THE SPECIAL INSPECTIONS FOR STEEL ELEMENTS OF BUILDINGS AND <br />STRUCTURES SHALL BE AS REQUIRED BY SECTION 1705.2 OF THE <br />CODE AND CONSTRUCTION DOCUMENTS. <br />EXCEPTIONS: <br />SPECIAL INSPECTIONS OF THE STEEL FABRICATION PROCESS SHALL <br />NOT BE REQUIRED WHERE THE FABRICATION PROCESS FOR THE <br />ENTIRE BUILDING OR STRUCTURE DOES NOT INCLUDE ANY WELDING, <br />THERMAL CUTTING OR HEATING OPERATION OF ANY KIND. IN SUCH <br />CASES, THE FABRICATOR SHALL BE REQUIRED TO SUBMIT A DETAILED <br />PROCEDURE FOR MATERIAL CONTROL THAT DEMONSTRATES THE <br />FABRICATOR'S ABILITY TO MAINTAIN SUITABLE RECORDS AND <br />PROCEDURES SUCH THAT, AT ANY TIME DURING THE FABRICATION <br />PROCESS, THE MATERIAL SPECIFICATION AND GRADE FOR THE MAIN <br />STRESS-CARRYING ELEMENTS ARE CAPABLE OF BEING DETERMINED. <br />MILL TEST REPORTS SHALL BE IDENTIFIABLE TO THE MAIN STRESS- <br />CARRYING ELEMENTS WHERE REQUIRED BY THE APPROVED <br />CONSTRUCTION DOCUMENTS. <br />ADHESIVE ANCHORING SYSTEMS <br />1. ADHESIVES USED FOR SETTING DOWELS AND ANCHORS SHALL BE IN <br />CONFORMANCE WITH ASTM C-881, TYPE IV. ACCEPTABLE MANUFACTURERS <br />FOR ADHESIVES ARE AS FOLLOWS: <br />MASONRY: <br />HILTI HIT-HY 100 (ICC ESR-3574) <br />SIMPSON SET (ICC ESR-1772) <br />CONCRETE: <br />SIMPSON SET-XP (ICC ESR-2508) <br />HILTI HIT-RE 500-SD (ICC ESR-2322) <br />HILTI HIT-HY 200 (ICC ESR-3187) <br />2. ANCHORS OR DOWELS EMBEDDED IN ADHESIVES SHALL BE INSTALLED PER <br />THE MANUFACTURER'S INSTRUCTIONS. <br />3. HOLES RECEIVING ADHESIVE ANCHORS SHALL BE PREPARE PER <br />MANUFACTURE'S RECOMMENDATION PRIOR TO APPLYING ADHESIVE. <br />4. HOLES DRILLED INTO REINFORCED CONCRETE OR MASONRY SHALL NOT <br />DAMAGE OR CUT EXISTING REINFORCING STEEL. LOCATE EXISTING <br />REINFORCING STEEL AND/OR TENDONS USING NON-DESTRUCTIVE METHODS <br />PRIOR TO DRILLING. <br />5. ALL ANCHORS INSTALLED WITH ADHESIVES SHALL HAVE CONTINUOUS SPECIAL <br />INSPECTION IN ACCORDANCE WITH THE EVALUATION REPORT (ICC-ER) AND <br />CODE SECTIONS 1705.3 AND 1705.4. <br />6. ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN THE UNDERSIDE OF FLOORS <br />OR ROOFS. <br />THE FOLLOWING DESIGN ELEMENTS WILL HAVE A DEFERRED <br />APPROVAL. THE CONTRACTOR IS RESPONSIBLE TO SUBMITTING DESIGN <br />OR SHOP DRWAINGS TO THE CITY OF SANTA ANA FOR REVIEW AND <br />APPROVAL. THE DRAWINGS SHALL BE COORDINATED WITH THE CITY OF <br />SANTA ANA AND ENGINEERS DRAWINGS. THE DESIGN SHALL, AT A <br />MIMIMUM, COMPLY WITH THE BUILDING CODE. THE TIME TO COMPLTE <br />THE PROCESS SHALL BE INCORPORATED INTO THE CONTRACTORS <br />SCHEUDLED. <br />WEATHER PROTECTION, WATERPROOFING, ROOFING, SIDING, <br />MECHANICAL, ELECTRICAL, PLUMNBING REPAIRS AND/OR <br />REPLACEMENT ARE BY OTHERS AND SHALL BE CONSIDRED DIFERRED <br />APPROVAL ITMES, IF REQUIRED. <br />N <br />I <br />R <br />No. S3866 <br />Exp. 3/31/26 <br />G <br />T <br />R <br />E <br />TATSS <br />E OFILACFO <br />UCTURA <br />R <br />L <br />R <br />STEREDP L <br />OFESSIONA <br />N <br />ER <br />AI <br />E <br />ENGI <br />WILLI <br />H.THORP <br />................ <br />. <br />. <br />. <br />............................... <br />. <br />. <br />. <br />............... <br />E <br />AM <br />18400 Von Karman Ave., Suite 600 <br />Irvine, CA 92612 <br />O: 949.252.1022 <br />F: 949.252.8082 <br />www.kpff.com <br />PRINCIPAL CIVIL ENGINEER <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />RCE NO.: <br />FILE NO.: <br />CITY OF SANTA ANA <br />PUBLIC WORKS AGENCY <br />REVISIONS REFERENCES <br />NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED <br />CONSTRUCTION COMPLETED: <br />www.DigAlert.org <br />TWO WORKING DAYS <br />BEFORE YOU DIG <br />Underground Service Alert <br />NOTICE TO CONTRACTOR <br />of Southern California <br />PURSUANT TO ASSEMBLY BILL 4216 NO EXCAVATION PERMIT <br />IS VALID UNLESS THE CONTRACTOR CONTACTS AND OBTAINS <br />A DIG ALERT TICKET NUMBER. CALL 811 AT LEAST TWO <br />WORKING DAYS PRIOR TO COMMENCING EXCAVATION. <br />KPFF OC STRUCTURAL ENGINEER <br />DATE <br />DESIGNED: DRAWN: CHECKED: <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />REVIEWED FOR <br />CONSTRUCTABILITY: <br />PREPARED UNDER <br />THE SUPERVISION <br />OF: <br />STEVEN DILLON 05/13/2024 <br />Know what's below. <br />before you dig.Call <br />R <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />3 <br />0 <br />0 <br />5 <br />5 <br />3 <br />: <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />T <br />I <br />T <br />L <br />E <br />: <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />Z <br />O <br />O <br /> <br />T <br />IC <br />K <br />E <br />T <br /> <br />B <br />O <br />O <br />T <br />H <br />FA-07161 <br />S0.1 <br />SDGY <br />1801 E. CHESTNUT AVE, SANTA ANA, CA 92701 <br />SANTA ANA ZOO TICKET BOOTHMW/MV <br />GENERAL NOTES <br />GENERAL NOTES <br />DESIGN CRITERIASTRUCTURAL OBSERVATION WOOD NOTES <br />GLULAM NOTES <br />STRUCTURAL STEEL NOTES <br />ADHESIVE ANCHORAGE SYSTEM NOTES <br />SHEET 2 OF 7 <br />DEFFERED APPROVAL <br />1. THE MANUFACTURE AND FABRICATION OF STRUCTURAL GLUE-LAMINATED <br />TIMBER SHALL BE IN CONFORMANCE WITH THE CURRENT EDITION OF THE <br />AMERICAN NATIONAL STANDARD / AMERICAN INSTITUTE OF TIMBER <br />CONSTRUCTION "STRUCTURAL GLUE LAMINATED TIMBER" (ANSI/AITC A190.1). <br />2. ALL GLUE-LAMINATED MEMBERS SHALL BE DOUGLAS FIR COMBINATION <br />24F-V4. ALLOWABLE STRESS REQUIREMENTS ARE AS FOLLOW S: <br />Fbxx = 2400 PSI (TENSION IN TENSION ZONE) <br />= 1850 PSI (TENSION IN COMPRESSION ZONE) <br />Fc┴= 650 PSI <br />Fc//= 1650 PSI <br />Fv = 265 PSI <br />Exx = 1.8x 106/ <br />3. MEMBERS LEFT EXPOSED TO WEATHER SHALL BE ALASKA YELLOW CEDAR <br />20F-V12 AC/AC COMBINATION. FINISH OF THE MEMBERS SHALL BE <br />INDUSTRIAL APPEARANCE GRADE UNLESS NOTED OTHERWISE IN <br />CONFORMANCE WITH THE STANDARD APPEARANCE GRADES OF THE AITC. <br />4. THE MANUFACTURER SHALL SUBMIT COMPLETE SHOP DRAWINGS TO THE <br />ARCHITECT/ ENGINEER FOR APPROVAL PRIOR TO ANY FABRICATION. <br />5. PROVIDE CAMBERS AS NOTED ON THE DRAWINGS. <br />6. TEMPERATURE OF GLUE-LAMINATED TIMBER IS NOT TO EXCEED 150°F IN <br />SERVICE. <br />7. GLUE-LAMINATED MEMBERS SHOWN ON THESE PLANS ARE FOR DRY <br />CONDITIONS OF USE. <br />8. GLB CONNECTIONS SHALL BE SIMPSON 'HGLT, HGLS' UNLESS NOTED <br />OTHERWISE. <br />9. FOR CANTILEVERED MEMBERS, PROVIDE 24F-V8 FOR DOUGLAS FIR OR <br /> 20F-V13 AC/AC FOR ALASKA YELLOW CEDAR. <br />106 PSI <br />DOUGLAS FIR GLB MEMBERS SHOWN ON THESE PLANS SHALL BE <br />PRIMED AND PAINTED. ALASKA YELLOW CEDAR NEED NOT BE PAINTED.