Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.0.94 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />4 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Masonry - May 5, 2024 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />4 <br />5/14/2024 <br />3 Shear load <br />Load [lb]Capacity [lb]Utilization bV [%]Status <br /> Steel 1,838 8,730 22 OK <br /> Pryout bond 1,838 3,564 52 OK <br /> Masonry crushing strength 1,838 4,141 45 OK <br /> Masonry breakout in direction y-1,838 2,561 72 OK <br />3.1 Steel strength <br />Vsa = ESR value refer to ICC-ES ER-547 <br />f Vsa ³ Vua AC58 Table 3.2 + ACI 318-19 Table 17.5.2 <br />Vsa [lb]f f Vsa [lb]Vua [lb] <br />14,549 0.600 8,730 1,838 <br />Page 39