8070 8070 8070 <br />W03W03W01W01 <br />W02W02 D01D01 <br />W01W01 <br />D02D02 <br />D02D02 <br />UP <br />UP <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />CO/SD <br />SD <br />S1 <br />A-4 <br />S1 <br />A-4 <br />S1 <br />A-4 <br />S1 <br />A-4 <br />S2 <br />A-4 <br />S2 <br />A-4 <br />S2 <br />A-4 <br />S2 <br />A-4 <br />46'-4 1/4" <br />11'-4" <br />14'-1" <br />4'-7" <br />9' <br />9'-2"10'10'10' <br />19' <br />1'-6" <br />7'-2" <br />KITCHEN <br />BEDROOM <br />LIVING ROOM <br />BATHROOM <br />CL <br />GARAGE GARAGE GARAGE <br />55 <br />44 <br />44 <br />11 22 33 <br />88 <br />77 E2E2 <br />E1E1 <br />1 <br />A-3 <br />1 <br />A-3 <br />WH <br />MINI-SPLIT CONDENSER <br />UNDER STAIRS <br />MS <br />MS <br />WH WH <br />36"x36" LANDING <br />MAX 7 3/4" BELOW <br />THRESHOLD <br />2 <br />A-3 <br />2 <br />A-3 <br />ADD RED-GARD VAPOR AND <br />MOISTURE BARRIER (ICC ESR-1413) <br />2 <br />A-3 <br />2 <br />A-3 <br />2 <br />A-4 <br />2 <br />A-4 <br />2 <br />A-4 <br />2 <br />A-4 <br />INSPECTOR TO VERIFY <br />WINDOWS ARE EXISTING. <br />INSPECTOR TO VERIFY <br />WINDOWS ARE EXISTING. <br />INSPECTOR TO VERIFY <br />WINDOWS ARE EXISTING. <br />DOOR SCHEDULE <br />NUMBER WIDTH HEIGHT THICKNESS EX/IN <br />D01 36"80"1 3/4"EX <br />D02 32"80"1 3/8"IN <br />WINDOW SCHEDULE <br />NUMBER TYPE WIDTH HEIGHT TOP U-FACTOR SHGC <br />W01 LEFT SLIDING 51"40"80"0.3 0.3 <br />W02 LEFT SLIDING 84"53"80"0.3 0.3 <br />W03 LEFT SLIDING 30"30"80"0.3 0.3 <br />SHEET INDEX: <br />A-1 COVER SHEET & SITE PLAN <br />A-2 ELEVATIONS & WINDOW DETAILS <br />A-3 ADU FLOOR PLAN <br />A-4 ADU ELEVATIONS & SECTION VIEWS <br />T-1 STAIR REPLACEMENT SITE PLAN <br />SN-1 STRUCTURAL NOTES <br />SP-1 SPECIAL INSPECTIONS <br />S-1 STAIR FLOOR PLANS <br />S-2 STAIR ELEVATIONS <br />SD-1 STAIR DETAILS <br />SD-2 STAIR DETAILS <br />SD-3 STAIR DETAILS <br />BUILDING & SAFETY APPROVAL STAMP: <br />ALL EXISTING CONDITIONS & <br />MEASUREMENTS TO BE FIELD VERIFIED <br />11721 WHITTIER BOULEVARD, NO. 301 <br />WHITTIER, CA 90601 <br />(562) 457-0311 <br />WWW.URBANAXIS.NET <br />WINDOW & STAIR REPLACEMENT <br />ADU CONVERSION <br />1724 1/2, A, B, C N. SPURGEON STREET <br />SANTA ANA, CA 92706 <br />LEGEND: <br />SYMBOL DESCRIPTION <br />NEW 2x4 STUDS @ 16" O.C. <br />EXISTING STUD WALL <br />EXISTING CMU BLOCK WALL <br />CEILING FAN <br />SURFACE MOUNTED WALL LT FIXTURE <br />RECESSED LIGHT FIXTURE <br />MINI SPLIT UNIT – 2-ZONE <br />SMOKE DETECTOR (UL217) / CARBON MONOXIDE <br />DETECTOR (UL2034/2075) HARD WIRED 120 AC <br />W/BATTERY BACK-UP (TYP). <br />EXHAUST FAN CAPABLE OF AIR CHANGES EVERY 5 <br />MINUTES. MIN 50 CFM CAPACITY. SHALL BE <br />ENERGY STAR COMPLIANT AND BE HUMIDITY <br />CONTROLLED. <br />EXHAUST FAN - 280 CFM, NON-RECIRCULATING. <br />FANS SHALL BE ENERGY STAR COMPLIANT AND <br />BE DUCTED TO TERMINATE TO THE OUTSIDE OF <br />THE BUILDING. <br />30 GAL. WATER HEATER <br />KEY NOTES: <br />72" HIGH NON-ABSORBENT FINISH SHOWER WALL. <br />WINDOWS AT SHOWERS AND TUBS SHALL BE TEMPERED IF <br />LESS THAN 60" ABOVE A STANDING SURFACE & DRAIN INLET <br />PROVIDE ACCESS PANEL TO TRAP SLIP JOINT CONNECTION OR <br />USE RIGID TYPE CONNECTION. SHOWER SHALL HAVE MIN. <br />AREA OF NOT LESS THAN 1,024 SQ INCHES AND SHALL BE <br />CAPABLE OF ENCOMPASSING A 30" MIN AREA AND DIMENSIONS <br />SHALL BE MAINTAINED TO A POINT OF 72" ABOVE THE SHOWER <br />DRAIN INLET. <br />WALL COVERING SHALL BE CEMENT PLASTER, TILE, OR <br />APPROVED EQUAL T0 72" ABOVE INLET AT SHOWER OR TUB <br />WITH SHOWER. MATERIALS OTHER THAN STRUCTURAL <br />ELEMENTS TO BE MOISTURE RESISTANT. <br />WATER CLOSETS SHALL HAVE 30" CLEARANCE WIDTH & <br />24" CLEARANCE IN FRONT. <br />LOCATE HARD-WIRED, WITH BATTERY BACK-UP SMOKE <br />DETECTORS IN BEDROOMS AND HALLWAYS OR ADJACENT <br />ROOMS LEADING TO BEDROOMS. SMOKE DETECTOR SHALL BE <br />INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILL <br />ACTIVATE ALL ALARMS. <br />LOCATE HARD-WIRED, WITH BATTER BACK-UP CARBON <br />MONOXIDE DETECTORS OUTSIDE BEDROOMS. DETECTOR <br />SHALL BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE <br />ALARM WILL ACTIVATE ALL ALARMS. <br />30"X30" ATTIC ACCESS WITH 30" MIN. HEAD CLEARANCE. <br />MECHANICAL VENTILATION CONNECTED DIRECTLY TO <br />OUTSIDE CAPABLE OF PROVIDING FIVE AIR CHANGES. MIN. 50 <br />CFM CAPACITY. <br />BEDROOM WINDOWS TO PROVIDE A MINIMUM NET CLEAR <br />OPENING OF 5.7 SF AND 24" NET CLEAR OPENABLE HEIGHT & 20" <br />MIN. WIDTH. WINDOW SILL SHALL BE LOCATED A MAXIMUM OF <br />44" ABOVE FINISHED FLOOR. <br />GENERAL NOTES: <br />BATHROOM EXHAUST FANS SHALL BE ENERGY STAR (CBC <br />SECTION 4.506.1). <br />ALL 120-VOLT RECEPTACLE OUTLETS SHALL BE LISTED AS <br />TAMPER-RESISTANT (CEC 406.12). <br />ALL NEW SEWER/WATER FIXTURES SHALL CONNECT TO <br />EXISTING ONSITE FACILITIES. <br />ALL EXISTING NON-CONFORMING PLUMBING FIXTURES SHALL BE <br />UPGRADED TO NEW WATER CONSERVING FIXTURES PER SB407. <br />EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE <br />PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR <br />GLAZED OPENINGS IN ACCORDANCE WITH SECTION 1205.2 OR <br />SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE <br />TO PROVIDE AN AVERAGE ILLUMINATION OF 10 FOOT-CANDLES <br />OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE <br />FLOOR LEVEL. (1205.1 AND 1205.3). <br />INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILINGS <br />SHALL BE TESTED AS SPECIFIED IN SECTION 803. SPECIFY THE <br />CLASSIFICATIONS PER TABLE 803.11 AND SECTION 803.1. <br />ELECTRICAL NOTES: <br />PROVIDE ONE MIN SEPARATE 20-AMP CIRCUIT TO LAUNDRY <br />APPLIANCES WHERE APPLICABLE. <br />ALL LIGHTING SHALL INCLUDE HIGH EFFICIENCY FIXTURES TO <br />COMPLY WITH 2013 T-24 ENERGY REQUIREMENTS. <br />ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, <br />15 AND 20 AMPERE OUTLETS SHALL BE PROTECTED BY AN ARC- <br />FAULT CIRCUIT INTERRUPTER(S). REQUIREMENT IS FOR ENTIRE <br />CIRCUIT, NOT JUST THE OUTLETS. <br />KITCHEN COUNTER-TOP OUTLETS SHALL NOT BE SPACED MORE <br />THAN 24" APART. <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES, AND <br />EQUIPMENT CONTROLS SHALL BE LOCATED NO MORE THAN 48” <br />ABOVE FINISHED FLOOR, MEASURED TO THE TOP OF THE <br />FIXTURE, AND NO LESS THAN 15” ABOVE FINISHED FLOOR, <br />MEASURED TO THE BOTTOM OF THE FIXTURE. <br />WINDOW NOTES: <br />ALL WINDOWS SHALL BE DUAL GLAZED. <br />EVERY BEDROOM SHALL HAVE ONE EGRESS WINDOW WITH A <br />FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE FINISHED <br />FLOOR. <br />SEE ELEVATIONS FOR WINDOW SHAPE, GRID PATTERN AND <br />TRIM TYPE. <br />ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE <br />U.S. CONSUMER PRODUCT SAFETY COMMISSION. NEW <br />GLAZED OPENINGS WILL BE LABELED TO INDICATE THE <br />REQUIREMENTS OF THE TITLE 24 REPORT OR CERTIFIED U- <br />FACTOR OF 0.30 AND SOLAR HEAT GAIN COEFFICIENT OF 0.21 <br />PER PACKAGE D. <br />DOOR NOTES: <br />EXIT DOORS SHALL HAVE A CLEAR OPENING WIDTH OF 32" <br />OR PER SECTION 1005.1, WHICHEVER IS GREATER. <br />MIN. DOOR HEIGHT OF 6'-8". <br />SHALL BE CAPABLE OF OPENING 90 DEGREES. <br />THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE <br />48" NOMINAL. <br />EXIT DOOR SHALL BE PIVOTED OR SIDE-HINGED SWINGING <br />TYPE (1010.1.2). <br />11 <br />22 <br />33 <br />44 <br />55 <br />66 <br />77 <br />88 <br />LL <br />RR <br />MSMS <br />C/SC/S <br />E1E1 <br />E2E2 <br />CFCF <br />WHWH <br />PROPOSED ADU FLOOR PLAN1SCALE: 1/4" = 1' <br />EMERGENCY EGRESS2SCALE: N.T.S. <br />1-HOUR/STC 50 ASSEMBLY <br />SCALE: N.T.S. <br />2 <br />A-3 <br />2 <br />A-3 <br />A-3 <br />PLUMBING CALCS3SCALE: N.T.S. <br />PARTITION WALL DETAIL <br />SCALE: N.T.S. <br />1 <br />A-3 <br />1 <br />A-3 <br />1724 A, B & C N. SPURGEON STREET <br />VERTICALLY SLOTTED <br />CLIP CONNECTOR <br />EXISTING METER: 5/8" <br />PRESSURE:60 PSI+ <br />LENGTH FROM METER TO FURTHEST FIXTURE: 132' <br />REQUIRED BUILDING SUPPLY PIPE DIAMETER: 1" <br />REQUIRED METER SIZE PER CPC TABLE 610.4: 3/4"