www.hilti.com <br />Hilti PROFIS Engineering 3.0.89 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Masonry Lateral Spurgeon <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />12/10/2023 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: HY 270 + threaded rod 5.8 1/2, HIT-SC 18x50 <br /> Item number: 385422 HAS 5.8 1/2"x3-1/8" (element) / 2194247 HIT-HY <br /> 270 (adhesive) / 360485 HIT-SC 18x50 (sieve sleeve) <br /> Effective embedment depth: hef = 2.000 in. <br /> Material: 5.8 <br /> Evaluation Service Report: Hilti Technical Data <br /> Issued I Valid: - | - <br /> Proof: Design Method ASD Masonry <br /> Stand-off installation: <br /> Profile: <br /> Base material: Hollow CMU, L x W x H: 16.000 in. x 8.000 in. x 8.000 in.; <br /> Joints: vertical: 0.375 in.; horizontal: 0.375 in. <br /> Base material temperature: 68 °F <br /> Installation: Face installation <br /> Seismic loads no <br />Geometry [in.] <br />STAIR 1 AND 3SEGMENT A-B <br />Page 16