My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 E Dyer Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
1700 E Dyer Rd
>
1700 E Dyer Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:16 AM
Creation date
2/13/2026 5:01:11 AM
Metadata
Fields
Template:
Plan
Permit Number
20186841
101124762
Full Address
1700 E Dyer Rd
Street Number
1700
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
Document Relationships
101124762 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\1700 E Dyer Rd
20186841 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Dyer Rd\1700 E Dyer Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
partition partition <br />(a) <br />elevation <br />adult <br />(b) <br />elevation <br />children <br />FIGURE 11B-604.8.1.4 <br />WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT <br />TOE CLEARANCE <br />FIGURE 11B-604.8.1.2 <br />WHEELCHAIR ACCESSIBLE <br />TOILET COMPARTMENT DOORS <br />FIGURE 11B-604.8.1.4 <br />WHEELCHAIR ACCESSIBLE TOILET <br />COMPARTMENT TOE CLEARANCE <br />(c) <br />plan <br />ALTERNATE <br />DOOR <br />LOCATION <br />6 min <br />152 <br />9 min <br />229 <br />6 min <br />152 <br />12 min <br />305 <br />4 max <br />102 <br />4 <br />m <br />a <br />x <br />10 <br />2 <br />6 min <br />152 <br />6 min <br />152 <br />(b) <br />ambulatory <br />accessible water <br />closets <br />Fig. 11B-604.2 <br />11B-604.8.2 <br />AMBULATORY ACCESSIBLE TOILET <br />COMPARTMENT <br />CLEARANCE <br />DOOR PERMITTED <br />TO SWING OVER <br />HATCHED <br />PORTION <br />OF MANEUVERING <br />SPACE <br />FIGURE 11B-604.3.1 - SIZE OF CLEARANCE AT WATER CLOSETS <br />(a) <br />out-swinging <br />door <br />clearance <br />(b) <br />in-swinging <br />door <br />clearance <br />door permitted <br />to swing over <br />hatched portion <br />of maneuvering <br />space <br />FIGURE 11B-604.8.1.1.2 - MANEUVERING SPACE WITH SIDE-OPENING DOOR <br />clearance <br />(a) <br />out-swinging <br />door <br />maneuvering <br />space <br />FIGURE 11B-604.8.1.1.3 - MANEUVERING SPACE WITH END-OPENING DOOR <br />(b) <br />in-swinging <br />door <br />maneuvering <br />space <br />when door <br />swings in <br />clearance <br />door permitted to <br />swing over hatched <br />portion of <br />maneuvering space <br />17-19 <br />432-4 <br />83 <br />℄ <br />35-37 <br />889-940 <br />60 <br /> <br />m <br />i <br />n <br />15 <br />2 <br />4 <br />44 <br /> <br />m <br />i <br />n <br />11 <br />1 <br />8 <br />60 <br /> <br />m <br />i <br />n <br />15 <br />2 <br />4 <br />56 min <br />1422 <br />48 min <br />1219 <br />60 <br /> <br />m <br />i <br />n <br />15 <br />2 <br />4 <br />60 min <br />1524 <br />@ side door <br />maneuvering <br />space <br />59 min @ floor mounted <br />1499 water closet <br />56 min @ wall mounted <br />1422 water closet <br />60 <br /> <br />mi <br />n <br />15 <br />2 <br />4 <br />59 min @ floor mounted <br />1499 water closet <br />56 min @ wall mounted <br />1422 water closet <br />36 min <br />914 <br />when door <br />swings in <br />60 min maneuvering <br />1524 space <br />59 min @ floor mounted <br />1499 water closet <br />56 min @ wall mounted <br />1422 water closet <br />60 <br /> <br />m <br />i <br />n <br />15 <br />2 <br />4 <br />48 min <br />1219 <br />59 min @ floor mounted <br />1499 water closet <br />56 min @ wall mounted <br />1422 water closet <br />48 min <br />1219 <br />60 <br /> <br />m <br />i <br />n <br />15 <br />2 <br />4 <br />36 min <br />914 <br />SINK / URINAL <br />(a) <br />elevation <br />(b) <br />plan <br />FIGURE 11B-306.2 - TOE CLEARANCE <br />(a) <br />elevation <br />FIGURE 11B-306.3 - KNEE CLEARANCE <br />(b) <br />plan <br />(c) <br />elevation @ lavatory <br />(a) <br />wall hung type <br />(b) <br />stall type <br />FIGURE 11B-605.2 - HEIGHT AND DEPTH OF URINALS <br />PLAN <br />DRINKING FOUNTAINS <br />SPOUT HEIGHT AND KNEE CLEARANCE AT <br />DRINKING FOUNTAINS <br />DRINKING FOUNTAIN SPOUT LOCATION <br />FIGURE 11B-602.5 <br />FIGURE 11B-305.7.1 <br />MANEUVERING CLEARANCE IN AN <br />ALCOVE, FORWARD APPROACH <br />"HI" FOUNTAIN <br />"LOW" FOUNTAIN <br />PLAN OF "HI-LOW" DRINKING FOUNTAIN <br />NOTE: <br />IF X = 18 MIN. ALCOVE DEPTH, THEN Y = 32" MIN. <br />IF ALCOVE DEPTH (X) IS GREATER THAN 24", THEN <br />ALCOVE WIDTH (Y) MUST BE MINIMUM OF 36" CLEAR. <br />CLEAR FLOOR SPACE <br />AT "HI-LOW" DRINKING FOUNTAIN ALCOVES <br />11B-602.6 WATER FLOW. <br />THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM AND <br />SHALL BE LOCATED 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT. THE <br />ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO <br />THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3 <br />INCHES OF THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL <br />BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES <br />AND 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE <br />WATER STREAM SHALL BE 15 DEGREES MAXIMUM. <br />11B-602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. <br />SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE THE FINISH FLOOR <br />OR GROUND. <br />11B-602.9 PEDESTRIAN PROTECTION. <br />ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE <br />POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 <br />INCHES WIDE MINIMUM AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED, WING WALLS OR BARRIERS SHALL <br />PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. <br />6 max <br />152 <br />9 <br />229 <br />17-25 <br />432-635 <br />30 <br /> <br />m <br />i <br />n <br />76 <br />2 <br />27 <br /> <br />m <br />i <br />n <br />68 <br />6 <br />11 min <br />279 <br />8 min <br />203 <br />9 min <br />229 <br />25 max <br />635 <br />30 <br /> <br />m <br />i <br />n <br />76 <br />2 <br />11 min <br />279 <br />9 min <br />22929 <br /> <br />m <br />i <br />n <br />73 <br />7 <br />27 <br /> <br />m <br />i <br />n <br />68 <br />6 <br />8 min <br />203 <br />13-1/2 MIN <br />343 <br />17 max <br />432 <br />18" Min <br />48" MIN <br />36" Min <br />MORE THAN 24" <br />18" TO 19" <br />9" <br /> <br />M <br />I <br />N <br />27 <br />" <br /> <br />M <br />I <br />N <br />36 <br />" <br /> <br />M <br />A <br />X <br />8" MIN - KNEE <br />CLEARANCE <br />6" MAX - TOE CLEARANCE <br />17" MIN DEPTH <br />25" MAX (FIGURE 11B-306.2) <br />48" MIN <br />5" MAX 15" MIN <br />℄ <br />EQ <br />EQ <br />℄ <br />X <br />Y <br />X <br />> <br /> <br />2 <br />4 <br />" <br />36" MIN <br />Y <br />EQ <br />EQ <br />℄ <br />X <br />13-1/2 MIN <br />343 <br />Doors shall not swing into the clear floor space or clearance required for any fixture. Other than the door to the accessible water closet compartment, a door in <br />any position, may encroach into the turning space by 12 inches maximum. (11B-603.2.3) <br />Exceptions:(2)Where the toilet room or bathing room is for individual use and a clear floor space complying with Section 11B-305.3 is provided within the room <br />beyond the arc of the door swing,doors shall be permitted to swing into the clear floor space or clearance required for any fixture. <br />ACCESSIBILITY DETAILS FOR <br />RESTROOMS AND DRINKING FOUNTAINS <br />FLUSH <br />ACTIVATOR <br />ON WIDE <br />SIDE <br />SINGLE-ACCOMMODATION TOILET FACILITY ACCESSIBLE WATER CLOSET COMPARTMENT WITHIN <br />A MULTIPLE-ACCOMMODATION TOILET FACILITY <br />FLUSH <br />ACTIVATOR ON <br />WIDE SIDE <br />ALL DISPENSERS <br />40" MAX TO <br />HIGHEST <br />OPERABLE PART <br />TOP OF GRAB BAR <br />GRIPPING SURFACE <br />TRANSFER <br />SIDE <br />FIGURE 11B-604.7 <br />DISPENSER OUTLET LOCATION <br />FIGURE 11B-604.5.1SIDE WALL GRAB BAR AT WATER CLOSETS <br />FIGURE 11B-604.5.2 <br />REAR WALL GRAB BAR AT WATER CLOSETS <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY AS AN AID <br />FOR BUILDING DESIGN AND CONSTRUCTION. <br />18" <br />MIN. <br />32" MIN <br />CLEAR <br />60" <br />M <br />I <br />N <br />. <br />DIA. <br /> <br />C <br />L <br />E <br />A <br />R <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />CL <br />E <br />A <br />R <br />24 <br />" <br />MI <br />N <br />. <br />54 <br />" <br /> <br />M <br />I <br />N <br />. <br />12 <br />" <br />MA <br />X <br />. <br />60" MIN <br />17"-18"18" <br />MIN. <br />CL <br />12 <br />" <br />MA <br />X <br />. <br />54 <br />" <br /> <br />M <br />I <br />N <br />. <br />17"-18" <br />60" MIN <br />24 <br />" <br />MI <br />N <br />. <br />60" MIN. <br />18" <br />MIN. <br />32" MIN. <br />CLEAR <br />48 <br />" <br />MI <br />N <br />. <br /> <br />C <br />L <br />E <br />A <br />R <br />4" MAX. <br />54" MIN. <br />12" <br />MAX <br />42" MIN <br />GRAB BAR <br />24" MIN <br />7"-9" <br />℄ <br />19 <br />" <br /> <br />M <br />I <br />N <br />17 <br />" <br />- <br />1 <br />9 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />17"-18" <br />36" MIN <br />GRAB BAR <br />12" <br />MIN <br />24" MIN <br />℄ <br />CL <br />20 <br />2 <br />4 <br /> <br /> <br />D <br />X <br />U <br />- <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />A <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br />© <br />SEAL <br />PROJECT TEAM <br />MUNICIPAL APPROVAL STAMP <br />THESE DRAWINGS ARE CONFIDENTIAL AND SHALL BE IN THE <br />POSSESSION OF AUTHORIZED INDIVIDUALS ONLY. THESE DOCUMENTS <br />ARE THE EXCLUSIVE PROPERTY OF DxU ARCHITECTS AND SHALL NOT <br />BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION <br />SHEET TITLE & NUMBER <br />CLIENT <br />PROJECT <br />PROJECT NUMBER: <br />APPROVED BY: KKDRAWN BY: LO <br />NO.DATE ISSUE <br />OWNER <br />METHOD ART CORP <br />CONTACT: BRYNN MINER <br />(P) 714.599.1112 <br />EMAIL: MYCAVALIERS@HOTMAIL.COM <br />G1-101 <br />ACCESSIBILITY <br />DETAILS <br />7-ELEVEN WIN <br />COFFEE <br />1700 E DYER ROAD <br />SANTA ANA, CA. 92705 <br />STORE# 33155 <br />24-675 <br />Project Status <br />11/15/2024 CLIENT REVISION
The URL can be used to link to this page
Your browser does not support the video tag.