My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 E St Andrew Pl Unit #100 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Andrew Pl
>
1610 E St Andrew Pl Unit# 100
>
1610 E St Andrew Pl Unit #100 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:59 AM
Creation date
2/13/2026 5:01:11 AM
Metadata
Fields
Template:
Plan
Permit Number
101121865
Full Address
1610 E St Andrew Pl Unit# 100
Street Number
1610
Street Direction
E
Street Name
St Andrew
Street Suffix
Pl
Unit Number
100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Customer S&H Systems <br />Project Collectors.com <br />Job Number 10010 <br />2 INFORMATION Page1.2 <br />SPECIFICATION <br />1. <br /> <br />2.COLIMNS SHALL BE A500 GRADE C 50KSI <br />ANGLE, S, AND C SECTIONS SHALL BE ASTM A36 MATERIAL <br />3. ALL BOLTS SHALL BE IN ACCORDANCE WITH ASTM A325N, OR A307 AT STAIRS AND BRIDGING <br />4. BRIDGING SHALL BE 2 X 2 X 1/8 STEEL ANGLE <br />5. <br /> <br />6. GUARD RAILING BY OTHERS <br />7. <br />8. <br />9. <br />10. CONFORMANCE WITH LOCAL CODES IS THE RESPONSIBILITY OF THE OWNER. <br />11. INSTALLATION DRAWINGS AND MANUAL SHALL BE PROVIDED BY STEELE SOLUTIONS, INC. <br />ERECTION, IF NOT INCLUDED IN CONTRACT, IS THE RESPONSIBILITY OF THE OWNER OR DEALER, AND SHALL BE IN <br />ACCORDANCE WITH MANUFACTURER’S SPECIFICATION. <br />ALL MATERIAL SHALL BE PAINTED WITH ONE COAT OF STEELE SOLUTIONS, INC. STANDARD PAINT, SEE DRAWINGS FOR COLOR. <br />BASE PLATE ANCHORS SHALL BE CONCRETE ANCHORS, SIZE INDICATED ON DRAWING, OR ENGINEER APPROVED EQUAL. <br />OWNER SHALL ADVISE STEELE SOLUTIONS, INC. OF CONCRETE FLOOR THICKNESS. OWNER SHALL ADVISE THE INSTALLERS OF <br />ANY EMBEDDED FLOOR OBSTACLES THAT MAY INTERFERE WITH INSTALLATION OF THE FLOOR ANCHORS. <br />SUPPORT COLUMNS SHALL BE STRUCTURAL STEEL TUBING MEETING THE REQUIREMENTS OF ASTM A500, GRADE C , Fy = 50 KSI, <br />OR AS INDICATED ON DRAWING. DESIGN IS IN ACCORDANCE WITH AISC SPECIFICATIONS. <br />DESIGN OF BAR GRATING IS IN ACCORDANCE WITH 'NAAMM METAL BAR GRATING MANUAL <br /> <br />COLD-FORMED STEEL SHALL MEET THE REQUIREMENTS OF ASTM A1011 GRADE 50 AND DESIGNED PER AISI DESIGN <br />OF COLD-FORMED STEEL STRUCTURAL MEMBERS <br />Steele <br />Solutions Inc. <br />DECK MATERIAL SHALL BE Bar Grating <br />6737 W. Washington St. West Allis, WI 53214 ]
The URL can be used to link to this page
Your browser does not support the video tag.