One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com <br />© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. <br />DSX1-LED <br />Rev. 01/28/25 <br />Page 4 of 10 <br />COMMERCIAL OUTDOOR <br />Performance Data <br />Current (A) <br />Performance <br />Package <br />LED <br />Count <br />Drive <br />Current (mA)Wattage 120V 208V 240V 277V 347V 480V <br />Forward Optics <br />(Non-Rotated) <br />P1 30 530 51 0.42 0.24 0.21 0.18 0.15 0.11 <br />P2 30 700 68 0.56 0.33 0.28 0.24 0.20 0.14 <br />P3 30 1050 104 0.85 0.49 0.43 0.37 0.29 0.21 <br />P4 30 1250 125 1.03 0.60 0.52 0.45 0.36 0.26 <br />P5 30 1400 142 1.15 0.66 0.58 0.50 0.40 0.29 <br />P6 40 1250 167 1.38 0.79 0.69 0.60 0.48 0.34 <br />P7 40 1400 188 1.54 0.89 0.77 0.67 0.53 0.38 <br />P8 60 1100 216 1.80 1.04 0.90 0.78 0.62 0.45 <br />P9 60 1400 279 2.31 1.33 1.15 1.00 0.80 0.58 <br />Rotated Optics <br />(Requires L90 <br />or R90) <br />P10 60 530 101 0.84 0.49 0.42 0.37 0.29 0.21 <br />P11 60 700 135 1.12 0.65 0.56 0.49 0.39 0.28 <br />P12 60 1050 206 1.72 0.99 0.86 0.74 0.59 0.43 <br />P13 60 1400 279 2.30 1.33 1.15 1.00 0.79 0.57 <br />Electrical Load <br />Motion Sensor Default Settings <br />Option Unoccupied Dimmed Level High Level <br />(when occupied)Phototcell Operation Dwell Time Ramp-up Time Dimming Fade Rate <br />PIR 30%100%Enabled @ 2FC 7.5 min 3 sec 5 min <br />NLTAIR2 PIRHN 30%100%Enabled @ 2FC 7.5 min 3 sec 5 min <br />Lumen Ambient Temperature (LAT) Multipliers <br />Use these factors to determine relative lumen output for average ambient temperatures <br />from 0-40°C (32-104°F). <br />Ambient Lumen Multiplier <br />0°C 32°F 1.04 <br />5°C 41°F 1.04 <br />10°C 50°F 1.03 <br />15°C 50°F 1.02 <br />20°C 68°F 1.01 <br />25°C 77°C 1.00 <br />30°C 86°F 0.99 <br />35°C 95°F 0.98 <br />40°C 104°F 0.97 <br />Projected LED Lumen Maintenance <br />Data references the extrapolated performance projections for the platforms noted in a 25°C <br />ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per <br />IESNA TM-21-11). <br />To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of <br />operating hours below. For other lumen maintenance values, contact factory. <br />Operating Hours Lumen Maintenance Factor <br />0 1.00 <br />25,000 0.95 <br />50,000 0.90 <br />100,000 0.81 <br />Controls Options <br />Nomenclature Description Functionality Primary control device Notes <br />FAO Field adjustable output device installed inside the <br />luminaire; wired to the driver dimming leads. <br />Allows the luminaire to be manually dimmed, <br />effectively trimming the light output. <br />FAO device Cannot be used with other controls options that need the <br />0-10V leads <br />DS (not available on DSX0)Drivers wired independently for 50/50 luminaire <br />operation <br />The luminaire is wired to two separate circuits, <br />allowing for 50/50 operation. <br />Independently wired drivers Requires two separately switched circuits. Consider nLight <br />AIR as a more cost effective alternative. <br />PER5 or PER7 Twist-lock photocell receptacle Compatible with standard twist-lock photocells for <br />dusk to dawn operation, or advanced control nodes <br />that provide 0-10V dimming signals. <br />Twist-lock photocells such as DLL Elite or <br />advanced control nodes such as ROAM. <br />Pins 4 & 5 to dimming leads on driver, Pins 6 & 7 are <br />capped inside luminaire. Cannot be used with other <br />controls options that need the 0-10V leads. <br />PIR Motion sensor with integral photocell. Sensor suitable <br />for 8' to 40' mounting height. <br />Luminaires dim when no occupancy is detected.Acuity Controls rSBG Cannot be used with other controls options that need the <br />0-10V leads. <br />NLTAIR2 PIRHN nLight AIR enabled luminaire for motion sensing, <br />photocell and wireless communication. <br />Motion and ambient light sensing with group <br />response. Scheduled dimming with motion sensor <br />over-ride when wirelessly connected to the nLight <br />Eclypse. <br />nLight Air rSBG nLight AIR sensors can be programmed and commissioned <br />from the ground using the ClAIRity Pro app. Cannot be used <br />with other controls options that need the 0-10V leads. <br />BL30 or BL50 Integrated bi-level device that allows a second control <br />circuit to switch all light engines to either 30% or 50% <br />light output <br />BLC device provides input to 0-10V dimming leads on <br />all drivers providing either 100% or dimmed (30% or <br />50%) control by a secondary circuit <br />BLC UVOLT1 BLC device is powered off the 0-10V dimming leads, thus <br />can be used with any input voltage from 120 to 480V <br />70 CRI 80CRI 90CRI <br />Lumen Multiplier Availability Lumen Multiplier Availability Lumen Multiplier Availability <br />5000K 102%Standard 92%Extended lead-time 71%(see note) <br />4000K 100%Standard 92%Extended lead-time 67%(see note) <br />3500K 100%(see note)90%Extended lead-time 63%(see note) <br />3000K 96%Standard 87%Extended lead-time 61%(see note) <br />2700K 94%(see note)85%Extended lead-time 57%(see note) <br />LED Color Temperature / Color Rendering Multipliers <br />Note: Some LED types are available as per special request. Contact Technical Support for more information.*Note: Calculated values are based on original performance <br />package data. When calculating new values for given FAO position, <br />use maximum published values by package listed on specification <br />sheet (input watts and lumens by optic type). <br />FAO Position % Wattage % Lumen Output <br />8 100%100% <br />7 93%95% <br />6 80%85% <br />5 66%73% <br />4 54%61% <br />3 41%49% <br />2 29%36% <br />1 15%20% <br />FAO Dimming Settings