CITY OF SANTA ANA <br />nmir��,genco <br />GENERAL CONDITIONS <br />1. GENERAL CONTRACT SHALL VISIT THE BUILDING SITE AND SHALL VERIFY <br />ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING ANY WORK AND <br />SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK AND <br />MATERIALS, INCLUDING THOSE FURNISHED BY SUB -CONTRACTORS. <br />ENGINEERS SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES. <br />2. ALL ASTM, ACI AND AISC DESIGNATIONS SHALL BE AMENDED TO MOST <br />RECENT DATE, UNLESS NOTED OTHERWISE. <br />3. GENERAL DETAILS ON THIS SHEET SHALL BE USED WHERE APPLICABLE, <br />UNLESS OTHERWISE NOTED. <br />4. ALL OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE <br />WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO <br />THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH ANY <br />WORK IN QUESTION. <br />5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE <br />FINISHED STRUCTURE.. THEY DO NOT INDICATE THE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE STRUCTURE, WORKERS AND PEDESTRIANS <br />DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE <br />LIMITED TO BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION <br />EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY COMPLETED <br />WORK, ETC. OBSERVATION VISITS TO THE SITE BY THE <br />ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTION OF SUCH ITEMS. <br />6. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT <br />UNIFORM BUILDING CODE AND ALL LOCAL CODE REQUIREMENTS. <br />7. IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, <br />SECTIONS OR DETAILS ON THE STRUCTURAL DRAWINGS. <br />8. REFER TO ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS <br />FOR MOULDS, ORNAMENTS, GROOVES, CUPS, GROUNDS, DROPPED SLABS, <br />CURBS, ETC,. OR ANY OTHER ITEMS NOT SHOWN ON STRUCTURAL <br />DRAWINGS. <br />9. NOTES, DETAILS, AND DRAWINGS SHALL TAKE PRECEDENCE OVER <br />GENERAL NOTES. <br />10. NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN <br />SLABS, BEAMS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED, <br />NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. <br />UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR <br />APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. <br />11. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE <br />RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF <br />CONSTRUCTION OF THIS PROJECT INCLUDING THE SAFETY OF ALL <br />PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY <br />CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND <br />THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE <br />CLIENT AND THE ARCHITECT/ENGINEER HARMLESS FROM AND ALL <br />LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE <br />OF WORK ON THIS PROJECT, EXCEPT FOR LIABILITY ARISING FROM THE <br />SOLE NEGLIGENCE OF THE CLIENT OR THE ARCHITECT/ENGINEER. <br />12. THESE NOTES SHALL BE CONSIDERED A PART OF OF THE WRITTEN <br />SPECIFICATIONS. <br />13. DESIGN CRITERIA: <br />CODE: <br />2022 CALIFORNIA BUILDING CODE <br />DEAD LOADS: <br />ROOF: 16 PSF <br />LIVE LOADS: <br />ROOF: 20 PSF <br />LATERAL LOADS: <br />WIND <br />SPEED = 95 MPH <br />EXPOSURE C <br />RISK CATEGORY TYPE - II <br />EARTHQUAKE <br />SEISMIC IMPORTANCE FACTOR = 1.0 <br />SEISMIC USE GROUP II <br />SS=1.283g, S1=0.459g <br />SITE CLASS=D <br />SDS=0.855g, SD1=0.872g <br />- <br />SEISMIC DESIGN CATEGORY=D <br />EQUIVALENT LATERAL FORCE PROCEDURE FOR BUILDING <br />STRUCTURE WAS USED. <br />SEISMIC RESPONSE COEFF. Cs=0.155 <br />R=5.5 <br />BASIC SEISMIC -FORCE -RESISTING SYSTEM <br />=LIGHT -FRAME WALLS <br />DESIGN BASE SHEAR V=0.141 W <br />V=6,932 LBS <br />Geo Report <br />Geotechnical Engineering Investigation Report by <br />Pacific Geotech, Inc. (Project No: 2157-S, <br />8-14-2024) <br />STRUCTURAL NOTES <br />1. CONCRETE USED IN THE WORK SHALL HAVE THE FOLLOWING ULTIMATE <br />COMPRESSIVE STRENGTH AT AGE OF 28 DAYS: <br />LOCATION IN ULTIMATE <br />STRUCTURE STRENGTH f'c <br />A. SLAB ON GRADE ......................................... ................ 2,500 PSI <br />B. WALL FOOTINGS.......................................................... 2,500 PSI <br />2. ALL CONCRETE SHALL BE STONE CONCRETE UTILIZING AGGREGATE <br />CONFORMING TO ASTM C33. CEMENT SHALL BE TYPE V CONFORMING TO <br />ASTM C150 MAXIMUM WATER -CEMENT RATIO SHALL BE .45 BY WIEGHT. <br />3. REINFORCING STEEL SHALL HAVE MINIMUM PROTECTIVE CONCRETE <br />COVERING AS FOLLOWS, UNLESS SPECIFICALLY DETAILED: <br />CONCRETE CAST AGAINST AND EXPOSED TO WEATHER OR EARTH ........3" <br />FORMED SURFACES EXPOSED TO WEATHER OR EARTH <br />A. #5 BAR OR SMALLER AND WIRE MESH ............................11 /2" <br />B. #6 TO #18 BARS.....................................................................2" <br />FORMED SURFACES NOT EXPOSED TO WEATHER OR EARTH <br />A. SLABS, WALLS, AND JOISTS...............................................3/4" <br />B. BEAMS AND COLUMNS.....................................................1 1 /2„ <br />4. BEFORE CONCRETE IS PLACED, THE CONTRACTOR SHALL COORDINATE AND <br />CHECK ALL TRADES TO ENSURE THE PROPER PLACEMENT OF ALL <br />OPENINGS, SLEEVES, INSERTS, CURBS, DEPRESSIONS, ETC. RELATING TO <br />THE WORK, AS SHOWN IN THE DRAWINGS. ANY CHANGE OR DISCREPANCY <br />SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. <br />5. ALL CONCRETE WITH A COMPRESSIVE STRENGTH IN EXCESS OF 2,500 PSI <br />AT 28 DAYS SHALL BE PLACED UNDER SUPERVISION OF A DEPUTY <br />INSPECTOR LICENSED BY THE LOCAL BUILDING OFFICIAL. <br />6. PLACEMENT DRAWINGS FOR THE REINFORCING STEEL SHALL BE PROVIDED <br />AT THE SITE A MINIMUM OF ONE WORKING DAY PRIOR TO PLACING OF <br />REINFORCING STEEL. <br />7. CONCRETE QUALITY: INSPECTIONS AND TESTS SHALL CONFORM TO THE <br />LOCAL BUILDING CODE REQUIREMENTS FOR CONCRETE DESIGNED BY THE <br />ULTIMATE STRENGTH METHOD. <br />8. ALL CONCRETE MIXES SHALL CONFORM TO THE PROPORTIONS ESTABLISHED <br />BY THE CODE FOR THE VARIOUS CONCRETE STRENGTHS REQUIRED FOR <br />WORK. CONTRACTOR SHALL ENGAGE A CERTIFIED INDEPENDENT TESTING <br />LABORATORY TO PREPARE 6 DESIGNS FOR THE WORK. COPIES OF THE MIX <br />DESIGN, AS WELL AS 7-DAY AND 28-DAY CYLINDER TEST RESULTS SHALL <br />BE SENT TO THE STRUCTURAL ENGINEER AND THE LOCAL BUILDING <br />OFFICIAL TO OBTAIN APPROVAL PRIOR TO ITS USE IN THE WORK. <br />9. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 318-05 <br />AND THE SPECIFICATION FOR CAST -IN -PLACE CONCRETE. <br />REINFORCING STEEL <br />1. ALL REINFORCING STEEL SHALL BE AS FOLLOWS: <br />A. NO.4 BARS AND SMALLER-INTERMIDIATE GRADE CONFORMING TO A615-40 <br />B. NO.5 BARS AND LARGER- HARD GRADE CONFORMING TO A615-60 <br />C. ALL MASONRY WALL REINFORCING, INCLUDING MASONRY WALL FOOTINGS, <br />SHALL BE INTERMEDIATE GRADE CONFORMING TO A615-60 <br />D. ALL BARS EXCEPT FOR N0.2 BARS SHALL BE DEFORMED AS PER ASTM <br />A305 <br />E. WIRE MESH SHALL CONFORM TO ASTM A185 <br />2. ALL BARS SHALL BE CLEAN OR RUST, GREASE OR OTHER MATERIALS LIKELY <br />TO IMPAIR BOND. <br />3. ALL BENDS SHALL BE MADE COLD. <br />4. SPLICING OF BARS SHALL HAVE LAPPING OF 48 BAR DIAMETERS OR 24" <br />MINIMUM IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND CONCRETE <br />WALLS, AND 48 BAR DIAMETER OR 24" MINIMUM IN MASONRY WALLS. UNLESS <br />OTHERWISE DETAILED, REINFORCING STEEL IN CONTINUOUS BEAMS AND <br />SPANDRELS SHALL HAVE TOP STEEL SPLICED AT MID -SPAN AND THE BOTTOM <br />STEEL SPLICED OVER SUPPORTS. <br />5. ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED <br />BEFORE POURING CONCRETE OR APPLYING MORTAR OR GROUT. <br />6. WELDING OF REINFORCING STEEL SHALL BE PERFORMED BY THE ELECTRIC ARC <br />PROCESS UTILIZING E70XX ELECTRODES, AND PERFORMED BY WELDERS <br />CERTIFIED BY THE CITY. <br />7. ALL WELDING TO BE DONE UNDER THE CONTINUOUS INSPECTION OF A DEPUTY <br />INSPECTOR REGISTERED BY THE CITY OR AS OTHERWISE REQUIRED BY THE <br />ENGINEER. <br />8, REINFORCING STEEL CAST AGAINST AND EXPOSED TO EARTH SHALL HAVE 3" <br />OF CLEAR COVER UNLESS SPECIFICALLY DETAILED OTHERWISE. <br />9. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, DEFORMED <br />UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM <br />A165 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES CLASS <br />"B" AND ALL HOOKS SHALL BE STANDARD UNLESS NOTED OTHERWISE. <br />10. A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF <br />CONCRETE U.N.O. IN ACCORDANCE WITH ACI 301. <br />STRUCTURAL LUMBER <br />(ALL LUMBER TO BE DOUGLAS FIR LARCH) <br />1. ALL STRUCTURAL WOOD MEMBERS SHALL BE IN THE BEST SELECTION OF <br />DOUGLAS FIR PER WCUB GRADING RULE #16. UNLESS NOTED OTHERWISE. EACH <br />PIECE OF LUMBER SHALL BE GRADE MARKED, AND COMPLY WITH THE FOLLOWING; <br />A. 2X STUDS, D.F. NO.2 U.N.O. <br />B. POSTS, 10' OR SHORTER, D.F. NO.2 U.N.O. <br />C. 2X AND 4X R/J, C/J, F/J, BEAMS HEADERS <br />D.F. NO.2 Fb=900 PSI / Fv=180 PSI / E=1,600,00 PSI <br />D.F. NO.1 Fb=1,000 PSI / Fv =180 PSI / E=1,700,000 PSI <br />D.F. NO.1 OR BTR Fb=1,200 PSI / Fv=180 PSI / E=1,800,000 PSI <br />D. 6X AND WIDER BEAMS AND HEADERS <br />D.F. NO.1 Fb=1,350 PSI / Fv=170 PSI / E=1,600,000 PSI <br />D.F.S.S. Fb=1,600 PSI / Fv=170 PSI / E=1,600,000 PSI <br />2. ALL STRUCTURAL PLYWOOD SHALL BE APA GRADE STAMPED, WITH EXTERIOR <br />GLUE AND AS SPECIFIED BY THE AMERICAN PLYWOOD ASSOCIATION, UNLESS <br />NOTED OTHERWISE ON PLANS. <br />3. SILLS AND PLATES RESTING IN CONCRETE OR MASONRY SHALL BE PRESSURE <br />TREATED DOUGLAS FIR. BOLTS SHALL BE 5/8" MINIMUM DIAMETER EMBEDDED <br />AT LEAST 7" INTO THE CONCRETE OR MASONRY AND SPACED NOT MORE THAN <br />6 FEET APART. THERE SHALL BE A MINIMUM OF 2 BOLTS PER PIECE WITH 1 <br />BOLT LOCATED WITHIN 12" OF EACH END OF EACH PIECE. <br />4. PRE -DRILL ALL HOLES FOR 20d NAIL OR LARGER AND LAG BOLTS. <br />5, DOUBLE TOP PLATES ON ALL EXTERIOR AND BEARING PARTITIONS (NOT <br />OTHERWISE DETAILED) SHALL LAP 4'-0" MINIMUM AT SPLICES AND HAVE 8-16d <br />MINIMUM THRU EACH SIDE OF SPLICE PLATES. <br />6. BOLT HEADS AND NUTS BEARING ON WOOD SHALL HAVE METAL WASHERS (SEE <br />SCHEDULE). BOLT HOLES IN WOOD SHALL BE DRILLED 1 /32" TO 1 /16" <br />DIAMETER LARGER THAN THE NOMINAL BOLT DIAMETER. <br />7. LAG BOLTS SHALL HAVE LEAD HOLES BORED BEFORE DRIVING. HOLE DIAMETER <br />TO BE AS FOLLOWS: <br />A. SHANK PORTION - SAME DIAMETER AND LENGTH AS SHANK <br />B. THREAD PORTION - .60 TO .75 DIAMETER OF THREAD AND SAME LENGTH. <br />8. ALL WOOD EXPOSED TO WEATHER OR MOISTURE SHALL BE PRESSURED TREATED <br />DOUGLAS FIR. <br />NAILING SCHEDULE <br />ALL NAILING SHALL BE COMMON WIRE NAILS CONFORMING TO THE LATEST C.B.0 <br />WHERE AUTOMATIC NAILING IS USED. NAIL HEADS SHALL NOT PENETRATE <br />SHEATHING. CONNECTIONS LISTED ARE THE MINIMUM PERMISSIBLE. DETAILS GOVERN <br />OVER THE SCHEDULE. <br />A. <br />JOIST TO SILL GIRDER, TOE NAILS EACH SIDE......................................3-8d <br />B. <br />BRIDGING TO JOIST RAFTER, TOE NAIL EACH END................................2-8d <br />C. <br />SUBFLOOR SHEATHING ALL BEARING <br />1 X6 OR LESS, FACE NAIL .................... ........................ ........................... 2-8d <br />1 X8 OR WIDER, FACE NAIL.............:.......................................................3-8d <br />2XBLIND AND FACE NAIL......................................................................2-16d <br />D. <br />SOLE PLATE TO JOIST OR BLOCKING <br />FACE NAIL......................._.........................................................16d @16" <br />O.C. <br />AT BRACE WALL...................................................................3-16d @16" <br />O.C. <br />F. <br />STUD TO SOLE PLATE, TOE NAIL - ........................ ......................... ...... 4-16d <br />G. <br />DOUBLE STUDS, FACE NAIL.....................................................16d @24" <br />O.C. <br />H. <br />TOP PLATE TO STUD, END NAIL...........................................................2-16d <br />I. <br />TOP PLATES, EACH END OF LAP SPLICE............................................8-16d <br />AT CORNER INTERSECTION........................................................... ........ 2-16d <br />J. <br />RIM JOIST TO TOP PLATE, TOE NAIL.........................................8d @16" <br />O.C. <br />K. <br />CONTINUOUS HEADER, TWO PIECES, ALONG EACH SIDE ......... 16d @ 16" <br />O.C. <br />L. <br />CONTINUOUS HEADER TO STUD, TOE NAIL ....... ..................................... 4-8d <br />M. <br />CEILING JOIST TO PARALLEL RAFTER, FACE NAIL ................... ......3 <br />16d <br />N. <br />CEILING JOISTS LAPS OVER PARTITIONS, FACE NAIL ............... .....3-16d <br />0. <br />CEILING JOIST OR RAFTERS TO ALL BEARINGS, TOE NAIL.....................3 <br />8d <br />P. <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOE NAIL ..... 3-8d <br />Q. <br />1" BRACE TO EACH STUD AND PLATE, FACE NAIL................................2-8d <br />R. <br />BUILT-UP CORNER STUDS.....................................................16d @24" <br />O.C. <br />S. <br />JOIST OR RAFTER TO SIDES OF STUDS UP TO AND INCLUDING 8" DEPTH. <br />........ ......................... ......................... ......................... . ........................... 3-16 <br />d <br />T. <br />CEILING STRIPS 1 %4" TO UNDERSIDE OF JOIST <br />- EACH BEARING ONE SLANT AND STRAIGHT......................................2-8d <br />- 2"x3" TO UNDERSIDE OF JOIST EACH BEARING ONE SLANT AND <br />STRAIGHT................................................. ............................................. 2-16d <br />USE STRONG HOLD ANGULARLY GROOVED AT GYPSUM BOARD AND PLASTER <br />CEILINGS. STRIPS SUPPORTING PLASTER CEILINGS SHALL BE WIRED IN PLACE <br />IN ADDITION TO NAILING. <br />U. <br />BUILT UP BEAMS <br />2-2x.....................................16d @ 12" O.C. EACH SIDE, 4-16d @ EACH <br />END <br />3 (OR MORE)........................1 /2"0 M.B. @ 24" O.C. STAGGERED <br />& 18d @ 12" O.C. PROGRESSIVE <br />WASHER SCHEDULE <br />1. WASHERS SHALL BE USED UNDER HEADS AND <br />NUTS OF ALL BOLTS BEARING ON WOOD. <br />2. THE <br />WASHERS LISTED BELOW SHALL BE USED <br />IN THE FOLLOWING LOCATIONS: <br />A. <br />SOLE PLATES TO FOUNDATIONS <br />B. <br />WOOD LEDGERS AND CAPS TO CONCRETE <br />AND MASONRY WALLS. <br />C. <br />AGAINST THE 2X MEMBER WHEN 2X MEMBER IS BOLTED AGAINST A HEAVIER MEMBER <br />D. <br />STANDARD CUT WASHERS MAY BE USED <br />ELSEWHERE, UNLESS OTHERWISE NOTED ON <br />THE DRAWING. <br />BOLT <br />SQUARE PLATE <br />SIZE WASHER SIZE <br />%2" <br />2"x2"xO.299" THICK <br />5/8" <br />3"x3"x0.299" THICK <br />3/4" <br />3"x3"X5/6 THICK <br />/8" <br />3"x3"x5/6" THICK <br />1" <br />3.5%3.5"x3/8" THICK <br />FOUNDATIONS <br />1. <br />FOUNDATIONS DESIGN IS BASED ON 2022 CBC. <br />40 <br />Al <br />2. <br />ALLOWABLE SOIL PRESSURE: 1,500 PSF FOR CONTINUOUS FOOTING & FOR SPREAD <br />FOOTING <br />FOR <br />PE <br />3. <br />FOOTINGS SHALL BE POURED AGAINST FIRM UNDISTURBED NATURAL SOIL OR ENGINEERED, <br />COMPACTED FILL. <br />4. <br />FILL AT RAMP WALLS AND RETAINING WALLS SHALL BE CLEAN OF NON-EXPAN <br />IVE <br />MATERIAL FREE OF ORGANICS AND PLACED UNDER CONTROLLED COMPACTION TC <br />90% OF <br />MAXIMUM DENSITY, U.N.O. <br />Master <br />ID: <br />5. <br />ALL WATER SHALL BE REMOVED FROM FOUNDATION EXCAVATIONS PRIOR TO PL <br />C�. '-Le: <br />• <br />6. <br />PROVIDE ADEQUATE DRAINAGE BEHIND ALL RETAINING WALLS AWAY FROM BOIL <br />ING. <br />7. <br />HOLD DOWNS: BOLT HOLES SHALL BE Y6" (MAX.) OVERSIZED @ THE CONNECTIONS OF THE <br />HOLD DOWNS TO THE POST. <br />8. <br />HOLDOWNS TO BE INSTALLED INACCORDANCE WITH APPROVED ICBO SPECIFICATIONS. <br />VERIFY LOCATIONS OF HOLDOWNS AND ANCHOR BOLTS WITH ROUGH FRAMING AND <br />MANUFACTURED TEMPLATE TO ASSURE ACCURATE INSTALLATION. <br />9. <br />FOUNDATION EXCAVATION, UTILITY TRENCH EXCAVATION, SOIL BACK FILL, SUBGRADE <br />PREPARATION, SOIL RECOMPACTION AND INSPECTIONS TO BE PER SOIL REPORT AS <br />REQUIRED. IN THE ABSENCE OF SOIL REPORT, PROCEDURE TO BE CONFORMED TO THE <br />GOVERNING BUILDING CODE. <br />10. <br />ALL METAL ANCHORS, FASTENERS AND CONNECTORS SPECIFIED ON PLANS SHALL BE <br />FROM SIMPSON OR AN APPROVED EQUAL IN STRUCTURAL DESIGN LOAD VALUES. <br />11. <br />ALL ISOLATED POSTS TO HAVE SIMPSON CB'S U.N.O. <br />12. <br />TYPICAL A.B. TO BE 5/8"0 W/ MIN. 7" EMBED INTO CONCRETE FOOTING, MIN EDGE <br />DISTANCE TO CONCRETE EDGE = 13/4" MIN 2X P.T. SILL PL REQ'D W/ <br />3"X3"X%4" PL <br />WASHER. A.B. SPACING PER SHEAR WALL SCH'D. MINIMUM @ 6'-0" <br />O.C. AT ALL <br />EXTERIOR WALLS AND INTERIOR BEARING WALLS. MIN. (2)-A.B. PER <br />SILL PL AND (1) <br />A.B. @WITHIN 12" FROM END OF SILL PL. <br />13. <br />CONCLUSIONS AND RECOMMENDATIONS OF GEOTECHNICAL REPORTS ARE INCORPORATED <br />INTO THE DESIGN. <br />14. <br />ALL EXCAVATIONS AND FILL MATERIALS SHALL BE APPROVED BY THE <br />GEOTECHNICAL <br />ENGINEER PER THE SOILS REPORT. <br />15. <br />IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION <br />SHALL BE SLOPED <br />A MINIMUM OF 2 PERCENT AWAY FROM THE BUILDING, ACCORDING TO <br />THE SOILS <br />REPORT. <br />16. CONSTRUCTION SHOULD BE OBSERVED AND/OR TESTED AT THE FOLLOWING STAGES BY <br />PACIFIC GEOTECH. <br />1) SHORING EXCAVATIONS <br />2) GRADING AND COMPACTION <br />3) ALL FOOTING EXCAVATIONS BEFORE PLACEMENT OF STEEL <br />4) TRENCH BACKFILLS <br />5) WHEN ANY UNUSUAL CONDITIONS ARE ENCOUNTERED. <br />SPECIAL INSPECTION <br />1. SPECIAL INSPECTION SHALL BE DONE ACCORDING TO CBC 1704.3, "STATEMENT OF <br />SPECIAL INSPECTION" <br />2. THE STATEMENT OF SPECIAL INSPECTION SHALL IDENTIFY THE FOLLOWING: <br />2.1 THE MATERIALS, SYSTEMS, COMPONENTS AND WORK REQUIRED TO HAVE SPECIAL <br />INSPECTION OR TESTING BY THE BUILDING OFFICIAL OR BY THE <br />REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR EACH PORTION OF THE <br />WORK <br />2.2 THE TYPE AND EXTENT OF EACH SPECIAL INSPECTION <br />2.3 THE TYPE AND EXTENT OF EACH TEST <br />2.4 ADDITIONAL REQUIREMENT FOR SPECIAL INSPECTION OR TESTING FOR SEISMIC OR <br />WIND RESISTANCE AS SPECIFIED IN SECTION 1705.10, 1705.11 AND 1705.12. <br />2.5 FOR EACH TYPE OF SPECIAL INSPECTION, IDENTIFICATION AS TO WHETHER IT <br />WILL BE CONTINUOUS SPECIAL INSPECTION OR PERIODIC SPECIAL INSPECTION. <br />ANCHOR BOLTS <br />2 <br />I. ALL EXTERIOR WALLS TO BE SECURED WITH 5/8"Ox12" A.B. AT 60" O.C. WITH 7" OF <br />EMBEDMENT, U.N.O. AND EACH ANCHOR BOLT SHALL HAVE MINIMUM 2.5"x2.5"x1 /4" THICK <br />PLATE WASHER. <br />2. ALL INTERIOR WALLS WITH SHOT PINS: RAMSET #3348 OR EQUIVALENT AT 36" O.C. AT <br />BEARING WALLS AND 48" O.C. AT NON -BEARING WALLS, U.N.O. NO SHOT PIN IS ALLOW <br />AT SHEAR WALLS. <br />3, HOLES TO RECEIVE EXPANSION/WEDGE ANCHORS SHALL BE 1 /8" LARGER IN DIAMETER <br />THAN THE ANCHOR BOLT, DOWEL OR ROD AND SHALL CONFORM TO MANUFACTURER'S <br />RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. LOCATE <br />AND AVOID CUTTING EXISTING REBAR WHEN DRILLING HOLES IN ELEVATED CONCRETE <br />SLABS. <br />4. USE AND INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER ICBP <br />& MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES. <br />0 10-20-23 YJ <br />For Approval <br />8-19-24 Perl YJ <br />GEO REPORT <br />ISS�J,� <br />hITN0- <br />U <br />Z <br />z_ <br />� <br />co <br />W <br />Z <br />co <br />w <br />z <br />� o <br />0 <br />N <br />O <br />wzm <br />W <br />�,�� <br />z <br />U <br />`Cy'i <br />U) <br />z z <br />(0W <br />� <br />' <br />O <br />U <br />r t� <br />(3) <br />L o <br />N <br />o <br />W <br />QC) <br />Z <br />J <br />o_ C6 <br />W N <br />T <br />J <br />J � <br />H W <br />c�0 <br />a� <br />�Q o <br />C) U) <br />� <br />0 <br />It J N <br />Lu <br />0 <br />Z:) W N <br />Q Q 6' <br />U Q <br />® U) U <br />W w Q <br />c/) z <br />O �a <br />O co ~ <br />//�� //Z <br />T VJ <br />C0 <br />U C0 <br />Q <br />oQRpPESSIYJ <br />ONq��� <br />ct� o.0 3 ;;o <br />* xp. 05 S0/ 6 <br />T <br />0 <br />F <br />OF <br />C <br />F <br />CO <br />W <br />O <br />Z <br />J <br />Q <br />Z) <br />U <br />CL' <br />U) <br />Date <br />10-24-23 <br />Scale <br />AS NOTED <br />Drawn <br />YJ <br />Job <br />2023-31 <br />Sheet <br />S-1 <br />1 <br />