Laserfiche WebLink
ACD <br />MSPUM <br />JB <br />CBINV <br />ACD <br />BA <br />T <br />ED <br />BA <br />T <br />~55.16' <br />~1 <br />0 <br />3 <br />. <br />3 <br />9 <br />' <br />~67.47' <br />~9 <br />0 <br />. <br />6 <br />5 <br />' <br />~19 <br />. <br />0 <br />8 <br />' <br />6'-0" <br />20 <br />' <br />- <br />1 <br />1 <br />" <br />4'-3" <br />22 <br />' <br />- <br />2 <br />" <br />3'-8" <br />SLC <br />SITE PLAN WITH ROOF PLAN <br />SHEET NAME <br />SHEET NUMBER <br />PV-1 <br />PROJECT NAME <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />V1.0.0 <br />REVDATEDESCRIPTION <br />VERSION <br />URINITIAL RELEASE <br />EMPOWER ELECTRIC SOLAR <br />683 N POLLASKY AVE <br />CLOVIS, CA 93611 <br />TEL: (800) 306 6953 <br />CSLB: 1057693 <br />Email : permits@mpwrsolar.com <br />05/22/2025 <br />KE <br />N <br />N <br />E <br />T <br />H <br /> <br />C <br />H <br />E <br />A <br />T <br />H <br />A <br />M <br />14 <br />2 <br />5 <br /> <br />W <br /> <br />R <br />I <br />V <br />E <br />R <br /> <br />L <br />N <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br /> <br />U <br />S <br />A <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />O <br />U <br />T <br />H <br />E <br />R <br />N <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />E <br />D <br />I <br />S <br />O <br />N <br />(S <br />C <br />E <br />) <br />AP <br />N <br />: <br /> <br />0 <br />0 <br />1 <br />- <br />2 <br />9 <br />2 <br />- <br />2 <br />0 <br />A08-07-2025REVISION <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 3/32" = 1'-0" <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE <br />PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR <br />DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />NOTE: <br />A.ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br />NOTE: • 3/4" OR GREATER IMC, RMC, FMC, LFMC, PVC, <br />HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT <br />RUN EXPOSED CONDUIT RUN SHALL BE MIN. 7/8" ABOVE <br />ROOF. * ROMEX RUN INSIDE ATTIC <br />NOTE: ESS SEPARATION OF 3' MINIMUM FROM DOORS <br />AND WINDOWS DIRECTLY ENTERING THE DWELLING <br />UNIT AS PER CRC R328.4 <br />LEGEND <br />JB JUNCTION BOX <br />UM UTILITY METER <br />ACD VISIBLE OPEN LOCKABLE AC <br />DISCONNECT <br />MSP MAIN SERVICE PANEL <br />CB ENPHASE IQ COMBINER BOX 5 <br />BAT ENPHASE BATTERY <br />ED EMERGENCY DISCONNECT <br />INV (E) INVERTER <br />ACD (E) AC DISCONNECT <br />EXISTING MODULE <br />FENCE <br />GATE <br />PROPERTY LINE <br />CONDUIT <br />TREES <br />VENT, ATTIC FAN <br />(ROOF OBSTRUCTION) <br />CHIMNEY <br />PHOTOVOLTAIC MODULES <br />JA SOLAR JAM54S31-405/MR (405W) <br /> 67.8" <br /> <br />4 <br />4 <br />. <br />6 <br />5 <br />" <br />W RIVER LN <br />N <br />P <br />A <br />C <br />I <br />F <br />I <br />C <br /> <br />A <br />V <br />E <br />ONE - STORY <br />HOUSE <br />ROOF ACCESS POINT <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />EXISTING <br />DRIVEWAY <br />(N) 3/4" OR GREATER EMT CONDUIT <br />RUN (7/8 INCHES ABOVE ROOF) <br />(E) 22 KYOCERA KU265-6ZPA (265W) <br />PV MODULES <br />SLC SOLAR LOAD CENTER A <br />A <br />07 Aug 2025 <br />EXP : 30 Sep 2025 <br />STRUCTURAL ONLY