My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1334 N Santiago St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Santiago St
>
1334 N Santiago St
>
1334 N Santiago St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:01 AM
Creation date
2/13/2026 5:01:13 AM
Metadata
Fields
Template:
Plan
Permit Number
101123059
Full Address
1334 N Santiago St
Street Number
1334
Street Direction
N
Street Name
Santiago
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PROJECT : PAGE : <br />CLIENT : DESIGN BY : <br />JOB NO. : DATE : REVIEW BY : <br />INPUT DATA <br />Exposure category (B, C or D)=C <br />Importance factor, pg 73, (0.87, 1.0 or 1.15)I =1.00 Category II <br />Basic wind speed (3 sec. gust wind) V = 95 mph <br />Topographic factor (Sec.6.5.7.2, pg 26 & 45)Kzt = 1 Flat <br />Height of top h = 8 ft <br />B = 10 ft <br />Dimension of return corner Lr = 0 ft <br />DESIGN SUMMARY <br />Max horizontal wind pressure p = 26 psf <br />Max total horizontal force at centroid of base F = 1.91 kips <br />Max bending moment at centroid of base M = 8.39 ft-kips <br />Max torsion at centroid of base T = 3.26 ft-kips <br />ANALYSIS <br />Velocity pressure <br />qh = 0.00256 Kh Kzt Kd V2 I =16.69 psf <br />where: qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27) <br />Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)= 0.85 <br />Kd = wind directionality factor. (Tab. 6-4, for building, page 80)= 0.85 <br />h = height of top = 8.00 ft <br />Wind Force Case A: resultant force though the geometric center (Sec. 6.5.14 & Fig. 6-20) <br />p = qh G Cf ==20 psf <br />F = p As =1.63 kips <br />M = F (h - 0.5s) for sign, F (0.55h) for wall =7.18 ft-kips <br />T ==0.00 ft-kips <br />where: G = gust effect factor. (Sec. 6.5.8, page 26).= 0.85 <br />Cf = net force coefficient. (Fig. 6-20, page 73)1.44 <br />As = B s = 80.0 ft2 <br />Wind Force Case B: resultant force at 0.2 B offset of the geometric center (Sec. 6.5.14 & Fig. 6-20) <br />p = Case A =20 psf <br />F = Case A =1.63 kips <br />M = Case A =7.18 ft-kips <br />T = 0.2 F B =3.26 ft-kips <br />Wind Force Case C: resultant force different at each region (Sec. 6.5.14 & Fig. 6-20) <br />p = qh G Cf <br />F = S p As <br />M = S [ F (h - 0.5s) for sign, F (0.55h) for wall ] <br />T = S Ts <br />s Distance Cf Pi Asi Fi Mi Ti <br />0 (ft) (Fig.6-20)2)(kips)(ft-kips)(ft-kips) <br />2.25 1 8.0 1.800 26 64 1.63 7.19 1.63 <br />1.50 2 <br />1.50 3 <br />1.50 4 <br />1.50 5 <br />1.50 10 <br />1.50 B 10.0 1.200 17 16 0.27 1.20 -1.09 <br />S 1.91 8.39 0.54 <== Case C may not be considered, footnote 3 of Fig. 6-20 <br />Moksudur <br />Rahman <br />GATE <br />Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-16
The URL can be used to link to this page
Your browser does not support the video tag.