My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1401 N Tustin Ave Unit# 170 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tustin Ave
>
1401 N Tustin Ave Unit# 170
>
1401 N Tustin Ave Unit# 170 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:19 AM
Creation date
2/13/2026 5:01:14 AM
Metadata
Fields
Template:
Plan
Permit Number
40139977
101122378
Full Address
1401 N Tustin Ave Unit# 170
Street Number
1401
Street Direction
N
Street Name
Tustin
Street Suffix
Ave
Unit Number
170
Document Relationships
101122378 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\1401 N Tustin Ave Unit# 170
40139977 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\1401 N Tustin Ave Unit# 170
Text box
ID:
1
Creator:
Import Agent
Created:
2/13/2026 5:02 AM
Modified:
2/12/2026 7:41 AM
Text:
www.hilti.com
ID:
2
Creator:
Import Agent
Created:
2/13/2026 5:02 AM
Modified:
2/12/2026 7:41 AM
ID:
3
Creator:
Import Agent
Created:
2/13/2026 5:02 AM
Modified:
2/12/2026 7:41 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.10 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />SimonMed Santa Ana Mech'l Yrd Fence Post <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />2/24/2025 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: Kwik Bolt TZ2 - SS 304 3/4 (4 3/4) hnom3 <br /> Item number: 2210288 KB-TZ2 3/4x7 SS304 <br /> Specification text: Hilti Æ 3/4 in Kwik Bolt TZ2 - SS 304 with 5.5 in <br /> nominal embedment depth per ICC-ES <br /> ESR-4266 , Hammer drilled installation per <br /> MPII <br /> Effective embedment depth: hef,act = 4.750 in., hnom = 5.500 in. <br /> Material: AISI 304 <br /> Evaluation Service Report: ESR-4266 <br /> Issued I Valid: 12/1/2023 | 12/1/2025 <br /> Proof: Design Method ACI 318-19 / Mech <br /> Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) <br /> Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. <br /> Anchor plateR : lx x ly x t = 10.000 in. x 10.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) <br /> Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x 0.250 in. <br /> Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in. <br /> Installation: Hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: > No. 4 bar <br /> Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) <br /> Shear load: yes (17.10.6.3 (c)) <br />R - The anchor calculation is based on a rigid anchor plate assumption. <br />Geometry [in.] & Loading [lb, in.lb] <br />10 <br />1
The URL can be used to link to this page
Your browser does not support the video tag.