1401 N Tustin Ave Unit# 170 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tustin Ave
>
1401 N Tustin Ave Unit# 170
>
1401 N Tustin Ave Unit# 170 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:19 AM
Creation date
2/13/2026 5:01:14 AM
Metadata
Fields
Template:
Plan
Permit Number
40139977
101122378
Full Address
1401 N Tustin Ave Unit# 170
Street Number
1401
Street Direction
N
Street Name
Tustin
Street Suffix
Ave
Unit Number
170
Document Relationships
101122378 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\1401 N Tustin Ave Unit# 170
40139977 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\1401 N Tustin Ave Unit# 170
Text box
ID:
1
Creator:
Import Agent
Created:
2/13/2026 5:02 AM
Modified:
2/12/2026 7:41 AM
Text:
www.hilti.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.10 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />6 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />SimonMed Santa Ana - Chiller <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />6 <br />2/27/2025 <br />4.3 Concrete edge failure in direction y- <br />Vcb = (AVc <br />AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) <br />f Vcb ³ Vua ACI 318-19 Table 17.5.2 <br />AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b)* <br />AVc0 = 4.5 c2 <br />a1 ACI 318-19 Eq. (17.7.2.1.3) <br />y ed,V = 0.7 + 0.3(ca2 <br />1.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b) <br />y h,V = √1.5ca1 <br />ha <br />³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) <br />Vb = (7 (le <br />da)0.2 <br />√da)l a √f' <br />c c1.5 <br />a1 ACI 318-19 Eq. (17.7.2.2.1a) <br />Variables <br />ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] <br />3.000 3.000 1.200 6.000 2.000 <br />l a da [in.]f' <br />c [psi]y parallel,V <br />1.000 0.500 2,500 2.000 <br />Calculations <br />AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] <br />33.75 40.50 1.000 1.000 1,697 <br />Results <br />Vcb [lb]f concrete f Vcb [lb]Vua [lb] <br />3,394 0.700 2,376 1 <br /> *Anchor row defined by: Anchor 1; Case 3 controls <br /> When the input edge distance is set to "infinity", edge breakout verification is not performed in that direction <br />5 Combined tension and shear loads, per ACI 318-19 section 17.8 <br />bN bV z Utilization bN,V [%]Status <br />0.001 0.001 5/3 1 OK <br />bNV = bz <br />N + bz <br />V <= 1 <br />34 <br />1