My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1333 W Park Ln - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Ln
>
1333 W Park Ln
>
1333 W Park Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:20 AM
Creation date
2/13/2026 5:01:14 AM
Metadata
Fields
Template:
Plan
Permit Number
20185933
101123805
Full Address
1333 W Park Ln
Street Number
1333
Street Direction
W
Street Name
Park
Street Suffix
Ln
Document Relationships
101123805 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\1333 W Park Ln
20185933 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\1333 W Park Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air <br />2 Inverter Input (4) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 Load center Output (2) 3 AWG <br />THHN/THWN-2 <br />(1) 3 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT <br />E EXISTING <br />PAGE <br />REV: A 2/14/2025 <br />DIM NICHOLS <br />1333 W PARK LN, SANTA ANA, <br />CA, 92706 <br />PROJECT NUMBER: <br /> 109R-333NICH <br />SHEET <br />DESIGNER: <br />AMAL A PILLAI <br />CUSTOMER RESIDENCE: <br />TEL. (714) 916-7978 <br />APN: 001-301-06 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 09 26 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />#ESTAMP <br />ELECTRICAL CONT. <br />PV-4.1 <br />RAIL <br />6-12 AWG BARE <br />COPPER WIRE <br />5/16"-18 SS BOLT <br />SS SPLIT LOCK WASHER <br />(TORQUE TO 16 FT-LBS) <br />SNAPNRACK <br />GROUND LUG <br />BONDING <br />CHANNEL NUT <br />SS BONDING <br />PINS <br />NOTE: <br /> ALL HARDWARE IS INCLUDED FROM MANUFACTURER <br /> A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY <br />CONTINUOUS ROW OF MODULES <br /> GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL <br /> GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS <br />PARALLEL OR PERPENDICULAR TO RAIL <br /> ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER <br />WIRE <br />SNAPNRACK GROUNDING SCALE: NTS <br />POWER CONTROL SYSTEM (PCS): <br />SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR <br />SUPPLIED BY THE POWER PRODUCTION SOURCES <br />MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. <br />240.6(C). <br />SETPOINTS: <br /> - 180A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL <br /> - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) <br />ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO <br />BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A <br />2-POLE OCPD BREAKER PER CEC 210.4(B,D). <br />IF THE RELOCATED LOADS EXTEND MORE THAN 6 <br />FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 <br />INSTALLER MUST CHECK THE CONDITION, <br />INSTALLABILITY AND CODE COMPLIANCE OF <br />EXISTING EQUIPMENT. <br />GENERAL NOTES: <br />COLD WATER GAS BOND <br />MODULE CHARACTERISTICS <br />LONGI GREEN ENERGY <br />TECHNOLOGY CO LTD: <br />LR5-54HABB-400M <br />400 W <br />OPEN CIRCUIT VOLTAGE 37.05 V <br />MAX POWER VOLTAGE 30.94 V <br />SHORT CIRCUIT CURRENT 14.88 A