GENERAL NOTES <br />1. DRAWINGS HEREIN ARE THE PROPERTY OF ES ENGINEERING SOLUTIONS AND SHALL <br />NOT BE USED FOR ANY OTHER THAN THE LOCATION SHOWN HEREON NOR ALTERED, <br />COPIED, OR DUPLICATED WITHOUT ES ENGINEERING SOLUTIONS PERMISSION. <br />2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO <br />ORDERING ANY MATERIALS, AND NOTIFY ENGINEER IMMEDIATELY IF ANY DISCREPANCIES. <br />3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE TO CALIFORNIA BUILDING CODE 2022 (CBC 2022), AND <br />ALL APPLICABLE LOCAL CODES. <br />4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, AND SEQUENCE AND <br />FOR THE SAFETY OF THE WORKERS, CONSTRUCTION SITE AND THE BUILDING DURING CONSTRUCTION. <br />CONTRACTOR SHALL PROVIDE PROPER SHORING, BRACING, SCAFFOLDING AND ALL MEASURES REQUIRED BY <br />ALL NATIONAL, STATE AND LOCAL SAFETY PROVISIONS. <br />5. CONTRACTOR SHALL CAREFULLY STUDY THE PLANS, AND NOTIFY THE ENGINEER IN CASE OF UNCLEAR OR <br />ANY MISSING DETAILS BEFORE START OF THE CONSTRUCTION OR ORDERING ANY MATERIALS. <br />6. ENGINEER WILL NOT BE RESPONSIBLE FOR ANY WORK DONE NOT ACCORDING TO PLANS AND <br />SPECIFICATIONS HEREIN. <br />7. ALL MATERIALS SHALL CONFORM TO THE PLANS AND SPECIFICATIONS. <br />8. ALL MANUFACTURED MEMBERS OR HARDWARE SHALL BE INSTALLED PER MANUFACTURER REQUIREMENTS. <br />9. WHEN DRILLING IN EXISTING CONCRETE, CONTRACTOR SHALL VERIFY THAT ALL EXISTING REINFORCEMENT, <br />OR TENSION CABLES SHALL REMAIN UNDAMAGED. <br />10. PRIOR TO ANY EXISTING CONCRETE SAW CUTTING OR REMOVAL, CONTRACTOR SHALL CHECK IF EXISTING <br />CONCRETE CONTAINS ANY TENSION CABLES AND NOTIFY ENGINEER BEFORE STARTING THE CUTTING OR <br />REMOVAL PROCESS. <br />11. DURING THE EXISTING CONCRETE SAW CUTTING OR REMOVAL PROCESS, IF TENSION CABLES ARE <br />ENCOUNTERED, CONTRACTOR SHALL STOP THE PROCESS IMMEDIATELY AND CONSULT WITH THE ENGINEER <br />BEFORE PROCEEDING. <br />12. ANY WORK PERFORMED IN CONFLICT WITH PLANS, SPECIFICATIONS, OR ANY APPLICABLE CODE SHALL BE <br />CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE ENGINEER OR THE OWNER. ALSO, THE ENGINEER <br />WILL BE COMPENSATED FOR ANY ADDITIONAL DESIGN WORK RESULTED THEREOF. <br />13. DO NOT SCALE DRAWINGS, CONTRACTOR SHALL ONLY USE WRITTEN DIMENSIONS. <br />14. CONTRACTORS SHALL NOT START CONSTRUCTION UNLESS PLANS ARE APPROVED BY THE APPROVING <br />AGENCIES. CONTRACTOR SHALL ONLY USE APPROVED PLANS FOR CONSTRUCTION. <br />15. DETAILS DESIGNATED AS TYPICAL OR STANDARD SHALL BE APPLIED TO ALL SITUATIONS THAT ARE THE <br />SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. TYPICAL OR STANDARD DETAILS SHALL BE APPLIED <br />WETHER OR NOT THEY ARE REFERENCED ON THE PLANS. <br />16. CONTRACTOR SHALL COORDINATE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND <br />PLUMBING PLANS AND NOTIFY ENGINEER IF ANY CONFLICT BEFORE START OF THE CONSTRUCTION OR <br />ORDERING ANY MATERIALS. <br />17. CONTRACTOR SHALL CHECK THE BUILDING LOCATION WITH RESPECT TO PROPERTY LINES, AND VERIFY <br />ALL EXISTING CONDITIONS BEFORE EXCAVATION, AND NOTIFY ENGINEER IF ANY DISCREPANCIES. <br />18. IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS, AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE <br />MADE WITHOUT WRITTEN APPROVAL OF THE ENGINEER. <br />FOUNDATION NOTES <br />1. FOUNDATION DESIGN IS BASED ON 1500 PSF ALLOWABLE BEARING CAPACITY (PER <br />CBC TABLE 1806.2) <br />2. FOUNDATION SHALL BE PLACED A MINIMUM OF 24" (UNLESS NOTED OTHERWISE) <br />BELOW FINISH GRADE DIRECTLY ON UNDISTURBED VIRGIN SOIL, OR CERTIFIED <br />COMPACTED FILL. <br />3. ALL IMPORTED SOIL SHALL BE TESTED AND APPROVED BY THE SOIL ENGINEER <br />BEFORE BEING DELIVERED TO THE SITE. <br />4. CONTRACTOR SHALL PROVIDE PROPER SHORING, UNDERPINNING AND ALL MEASURES <br />REQUIRED BY ALL NATIONAL, STATE AND LOCAL SAFETY PROVISIONS TO PROTECT ANY ADJACENT <br />EXISTING FOUNDATIONS, PROPERTIES, STRUCTURES, STREETS, AND UTILITIES PRIOR TO <br />ANY EXCAVATION <br />5. FINISH GRADE IMMEDIATELY ADJACENT TO THE BUILDING SHALL BE SLOPED MINIMUM <br />2% AWAY FROM THE BUILDING UNLESS NOTED OTHERWISE. <br />6. CONTRACTOR SHALL NOT POUR THE CONCRETE UNLESS ALL REINFORCEMENT, <br />ANCHOR BOLTS, FRAMING HARDWARE, UTILITY CONDUITS AND PIPES, ETC., AND <br />FORMWORK ARE PROPERLY PLACED, SECURED, AND INSPECTED BY THE BUILDING <br />OFFICIAL OR BUILDING INSPECTOR. <br />7. FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 (VERTICAL) : 2 (HORIZONTAL) WHERE <br />NECESSARY. <br />8. WHEN WATER IS ENCOUNTERED, EXCAVATIONS SHALL BE DEWATERED TO ALLOW INSTALLATION OF <br />FOOTINGS IN DRY ATMOSPHERE. <br />STEEL REINFORCEMENT NOTES <br />1. ALL STEEL REINFORCEMENT SHALL BE DEFORMED, CLEAN, FREE OF RUST AND <br />CONFORM TO ASTM A615, GRADE 60. <br />2. WELDING OF STEEL REINFORCEMENT IS PROHIBITED (UNLESS NOTED OTHERWISE) <br />3. ALL WELDED WIRE MESH SHALL CONFORM WITH ASTM A185. <br />4. ALL STEEL REINFORCEMENT DETAILING SHALL CONFORM WITH ACI 318 CHAPTER 25. <br />5. ALL SPLICES SHALL BE CLASS "B". <br />6. ALL REINFORCEMENT BAR BENDS SHALL BE MADE COLD. HEATING BARS IS NOT <br />PERMITTED. <br />7. ALL REINFORCEMENT SHALL BE SECURED IN PLACE AND INSPECTED BY THE BUILDING <br />OFFICIAL OR BUILDING INSPECTOR BEFORE POURING THE CONCRETE. <br />REINFORCED CONCRETE NOTES : <br />1. CONCRETE WILL HAVE A MINIMUM COMPRESSIVE STRENGTH AS FOLLOWS: <br />A. SLAB ON GRADE......................2500 PSI 0 28 DAYS <br />B. SPREAD FOOTINGS...................2500 PSI ® 28 DAYS <br />C. CONTINUOUS FOOTINGS ..........2500 PSI ® 28 DAYS <br />DESIGN CALCULATIONS ARE BASED ON 2500 PSI CONCRETE AND FOOTINGS ARE <br />DESIGNED IN ACCORDANCE WITH CBC TABLE 1809.7; THEREFORE, SPECIAL INSPECTION <br />IS NOT REQUIRED. <br />2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE. <br />3. MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIO (W/CM RATIO) =0.55 <br />4. MAXIMUM CONCRETE SLUMP SHALL BE 4"f1" FOR SLAB ON GRADE, SPREAD <br />FOOTINGS, AND CONTINUOUS FOOTINGS. <br />5. ALL STEEL REINFORCEMENT SHALL BE PLACED TO PROVIDE MINIMUM CLEAR COVER <br />PER CBC SECTION 1808.8.2 AND ACI 318 SECTION 20.6 AS FOLLOWS <br />A. SLAB ON GRADE......................11" MINIMUM CLEAR COVER <br />B. SPREAD FOOTINGS...................3" MINIMUM CLEAR COVER <br />C. CONTINUOUS FOOTINGS ..........3" MINIMUM CLEAR COVER <br />6. ALL CONCRETE SHALL BE MIXED, TRANSPORTED, AND PLACED IN ACCORDANCE WITH <br />ACI STANDARDS 318, 3014, AND 301. <br />7. ALL STEEL REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. <br />8. WELDING OF STEEL REINFORCEMENT IS PROHIBITED (UNLESS NOTED OTHERWISE) <br />9. ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. <br />10. ALL CONCRETE WORK SHALL CONFORM WITH CBC CHAPTER 19 <br />11. ALL CEMENT SHALL BE PORTLAND CEMENT AND SHALL CONFORM WITH ASTM C150. <br />12. ALL AGGREGATE SHALL CONFORM WITH ASTM C33 <br />13. WATER SHALL CONFORM WITH ASTM C1602. <br />14. ADMIXTURE SHALL CONFORM WITH ASTM C494, ASTM C1017, ASTM C260, AND <br />ASTM C1582. <br />15. CONTRACTOR SHALL NOT POUR THE CONCRETE UNLESS ALL REINFORCEMENT, <br />ANCHOR BOLTS, FRAMING HARDWARE, UTILITY CONDUITS AND PIPES, ETC., AND <br />FORMWORK ARE PROPERLY PLACED, SECURED, AND INSPECTED BY THE BUILDING <br />OFFICIAL OR BUILDING INSPECTOR. <br />16. CONTRACTOR SHALL PROVIDE THE ENGINEER WITH THE LOCATION OF <br />CONSTRUCTION JOINTS AND CONTROL JOINTS (IF NOT SHOWN ON PLANS) FOR <br />APPROVAL PRIOR TO FORMING. <br />17. UNLESS SPECIFIED ON PLANS, CONTRACTOR SHALL NOT DRILL OR CORE IN <br />EXISTING OR NEW CONCRETE TO RUN UTILITY CONDUIT OR PIPES OR ANY OTHER <br />REASON WITHOUT THE ENGINEER'S APPROVAL. <br />18. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING, MAINTAINING, AND REMOVAL <br />OF FORM WORK, AND CONCRETE POURING IN ACCORDANCE TO ALL NATIONAL, STATE AND <br />LOCAL SAFETY PROVISIONS. <br />19. IN CASE OF EXPOSURE TO SULFATE, OR OTHER SPECIAL EXPOSURE AS DEFINED IN ACI 318 TABLE <br />19.3.1.1, CONCRETE DESIGN SHALL BE IN ACCORDANCE WITH ACI 318 TABLE 19.3.2.1. <br />20. BEFORE POURING NEW CONCRETE AGAINST EXISTING CONCRETE, EXISTING CONCRETE SURFACE SHALL BE <br />ROUGHENED TO f" AMPLITUDE. <br />FASTENER TABLE <br />FRAMING LUMBER NOTES : <br />1. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR -LARCH AND CONFORM TO WEST <br />COAST LUMBER INSPECTION BUREAU. <br />2. STRUCTURAL LUMBER SHALL CONFORM TO THE FOLLOWING GRADES UNLESS NOTED <br />OTHERWISE: <br />A. <br />STUDS............................................NO.2 <br />B. <br />JOISTS AND <br />RAFTERS....................NO.2 <br />C. <br />POSTS............................................NO.1 <br />D. <br />BEAMS AND <br />HEADERS...................NO.1 <br />E. <br />TOP PLATES..................................NO.2 <br />F. <br />SILL PLATES <br />..................................NO.2 PRESSURE TREATED <br />G. <br />BLOCKING.......................................CONSTRUCTION <br />GRADE <br />3. ALL WOOD MEMBERS IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE <br />TREATED WOOD. <br />4. ALL WOOD MEMBERS EXPOSED TO WEATHER SHALL BE PRESSURE TREATED AND <br />PAINTED WITH WEATHER PROOF PAINT. <br />5. MAXIMUM LATERALLY UNSUPPORTED STUD LENGTH, SIZE, AND SPACING SHALL BE <br />AS FOLLOWS <br />STUD SIZE LATERALLY UNSUPPORTED LATERALLY UNSUPPORTED <br />AND SPACING STUD HEIGHT (ONE STORY) STUD HEIGHT (TWO STORY) <br />2X4 @ 16" O.C. 10'-0" 10'-0" <br />2X6 ® 16" O.C. 16'-0" 16'-0" <br />6. PROVIDE CONTINUOUS DOUBLE BLOCKING OR DOUBLE JOISTS AS APPLICABLE UNDER <br />ANY NON -BEARING WALL BEARING ON FLOOR JOISTS (SEE PLANS FOR BEARING <br />WALLS). <br />7. ALL NAILING SHALL BE IN ACCORDANCE TO CALIFORNIA BUILDING CODE, CHAPTER <br />23. <br />8. BOLT HOLES SHALL BE T�" LARGER THAN BOLT DIAMETER. ALL BOLTS SHALL HAVE <br />WASHERS AND NUTS. <br />9. CONTRACTOR SHALL NOT CUT OR NOTCH EXISTING OR NEW WOOD MEMBERS UNLESS <br />SPECIFIED ON PLANS. <br />10. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE 0.229"X3"X3" <br />PLATE WASHER ON THE SUPPORTING MEMBER. HOLD-DOWN SHALL BE TIGHTENED TO <br />FINGER TIGHT PLUS ONE-HALF WRENCH TURN JUST PRIOR TO COVERING THE WALL <br />FRAMING. <br />11. ALL HOLD-DOWN, BOLTS, WASHER PLATES, NAILS, OR ANY STEEL FASTENER IN <br />CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT -DIPPED GALVANIZED. <br />12. ALL BEAM AND JOIST HANGERS SHALL BE THE FULL DEPTH OF THE SUPPORTED <br />MEMBER AND SHALL HAVE ALL HOLES FILLED IN WITH FASTENERS PER MANUFACTURER <br />REQUIREMENTS TO ACHIEVE THE MAXIMUM CAPACITY OF THE HANGER. <br />13. ALL STRAPS, HOLD-DOWN, AND ANY HARDWARE CONNECTION SHALL HAVE ALL <br />HOLES FILLED IN WITH FASTENERS PER MANUFACTURER REQUIREMENTS TO ACHIEVE <br />THE MAXIMUM CAPACITY. <br />14. ALL LUMBER SHALL BE DRY TO 19% AND PLYWOOD SHALL BE DRY TO 15% AT <br />TIME OF INSTALLATION AND WILL BE KEPT DRY AND PROTECTED AT ALL TIMES DURING <br />CONSTRUCTION. <br />15. ALL POSTS EXTENDING TO LOWER FLOOR SHALL BE CONTINUOUS BETWEEN UPPER <br />FLOOR BOTTOM PLATE AND BOTTOM FLOOR TOP PLATES WITH BLOCKING SAME SIZE <br />AS THE POST OR AS SPECIFIED ON PLAN. <br />16. IF NOT SHOWN ON PLANS, PROVIDE A POST UNDER EACH END OF ANY BEAM, <br />DOUBLE JOISTS, OR 3X MEMBER (SAME SIZE AS THE SUPPORTED MEMBER). <br />17. PROVIDE FULL DEPTH SOLID 2X BLOCKING AT 8'-0" O.C. MAXIMUM FOR FLOOR <br />JOISTS AND ROOF RAFTERS. <br />18. USE CBC TABLE 2304.10.1 FOR FASTENERS. <br />CONNECTION FASTENING REMARKS <br />ROOF <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE <br />4-81) BOX (2-1/2" X 0.113") <br />TOE NAIL <br />CEILING JOIST TO PLATE <br />4-81) BOX (2-1/2" X 0.113" <br />TOE NAIL <br />CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS <br />4-1 OD BOX 3" X 0.128" <br />FACE NAIL <br />COLLAR TIE RAFTER, FACE NAIL OR 1 X" 20-GAGE RIDGE STRAP <br />4-1 OD BOX 3 X 0.128 <br />FACE NAIL <br />RAFTER OR ROOF TRUSS TO PLATE <br />3-16D BOX NAILS (3-1/2" X 0.135 OR <br />3-10D COMMON NAILS 3" X 0.148" <br />2 TOE NAILS ON ONE SIDE AND 1 TOE NAIL <br />ON OPPOSITE SIDE OF EACH RAFTER OR TRUSS <br />ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS <br />OR ROOF RAFTER TO MINIMUM 2" RIDGE BEAM: <br />4-16D BOX (3-1/2- X 0.135 , OR <br />3-10D COMMON (3-1/2 "X 0.148" <br />TOE NAIL <br />3-16D BOX (3-1/2- X 0.135" , OR <br />2-16D COMMON (3-1/2" X 0.162" <br />END NAIL <br />WALL <br />STUD TO STUD (NOT BRACED WALL PANELS) <br />16D COMMON (3-1/2" X 0.162 <br />24" O.C. FACE NAIL <br />10D BOX 3" X 0.128" <br />16" O.C. FACE NAIL <br />STUD TO STUD AND ABUTTING STUDS AT INTERSECTING <br />WALL CORNERS (AT BRACED WALL PANELS) <br />16D BOX 3-1 2" X 0.135" <br />12" O.C. FACE NAIL <br />16D COMMON (3-1/2- X 0.162 <br />16" O.C. FACE NAIL <br />ABUTTING STUDS AT INTERSECTING WALL CORNERS, FACE NAIL <br />16D (3-1/2- X 0.135 " <br />12" O.C. <br />BUILT -UP HEADER (2" TO 2" HEADER WITH %" SPACER) <br />16D COMMON (3-1/2" X 0.162" <br />16" O.C. EACH EDGE FACE NAIL <br />16D BOX (3-1/2" X 0.135" <br />12" O.C. EACH EDGE FACE NAIL <br />CONTINUOUS HEADER TO STUD <br />5-81) BOX (2-1/2" X 0.113" <br />TOE NAIL <br />4 8D COMMON (2-1/2- X 0.131" <br />TOE NAIL <br />TOP PLATE TO TOP PLATE <br />16 COMMON (3-1/2 " X 0.162" <br />16" O.C. FACE NAIL <br />10D BOX 3 X 0.128 <br />12" O.C. FACE NAIL <br />DOUBLE TOP PLATE SPLICE <br />8-16D (3-1/2" X 0.135") <br />FACE NAIL ON EACH SIDE OF END JOINT <br />MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF JOINT <br />BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT <br />AT BRACED WALL PANELS) <br />16D COMMON (3-1/2" X 0.162" <br />16" O.C. FACE NAIL <br />16D BOX (3-1/2" X 0.135 " <br />12" O.C. FACE NAIL <br />BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR <br />BLOCKING AT BRACED WALL PANEL <br />3-16D BOX (3-1/2" X 0.135"), OR <br />2-16D COMMON (3-1/2" X 0.162" <br />3 EACH 16" O.C. FACE NAIL <br />2 EACH 16" O.C. FACE NAIL <br />TOP OR BOTTOM PLATE TO STUD <br />4-81) BOX (2-1/2" X 0.113"), OR <br />3-16D BOX (3-1 /2"X 0.135"), OR <br />4-81) COMMON (2-1/2" X 0.131)" <br />TOE NAIL <br />3-16D BOX 3-1 2 X 0.135 , OR <br />END NAIL <br />2-16D COMMON 3 3F X 0.135 , OR <br />2-10D (3" X 0.162"), OR <br />3-10D BOX 3" X 0.128" <br />END NAIL <br />TOP PLATES, LAP AT CORNERS AND INTERSECTIONS <br />3-10D BOX (3" X 0.128"), OR <br />2-16D COMMON 3 1 2" X 0.162" <br />FACE NAIL <br />FLOOR <br />JOIST TO SILL, TOP PLATE OR GIRDER <br />4-81) BOX (2-1/2- X 0.113 , OR <br />3-81) COMMON (2-1/2" X 0.131), OR <br />3-10D BOX 3" X 0.128" <br />TOE NAIL <br />RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE <br />(ROOF APPLICATIONS ALSO) <br />8D BOX (2-1/2- X 0.113" <br />4" O.C. <br />8D COMMON (2-1/2" X 0.131"), OR <br />10D BOX 3" X 0.128" <br />6" O.C. <br />BAND OR RIM JOIST TO JOIST <br />3-16D COMMON (3-1/2- X 0.162 , OR <br />4-10D BOX 3" X 0.128" <br />END NAIL <br />BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS <br />20D COMMON (4" X 0.192"), OR <br />NAIL EACH LAYER AS FOLLOWS: 32" O.C. AT <br />TOP AND BOTTOM AND STAGGERED. <br />10D BOX (3" X 0.128"), OR <br />24" O.C. FACE NAIL AT TOP AND BOTTOM <br />STAGGERED ON OPPOSITE SIDES <br />AND: <br />2-20D COMMON (4" X 0.192"), OR <br />3-10D BOX 3" X 0.128" , <br />FACE NAIL AT ENDS AND AT EACH SPLICE <br />LEDGER STRIP SUPPORTING JOISTS OR RAFTERS <br />4-16D BOX (3-1/2 "X 0.135"), OR <br />3-16D COMMON (3-1/2- X 0.162), OR <br />4-10D BOX 3" X 0.128" <br />AT EACH JOIST OR RAFTER, FACE NAIL <br />BRIDGING TO JOIST <br />2-10D 3" X 0.128" <br />EACH END, TOE NAIL <br />DESIGN CRITERIA: <br />1. BUILDING CODE : <br />PLANS ARE PREPARED IN ACCORDANCE TO CALIFORNIA BUILDING CODE 2022 (CBC 2022). <br />ALL WORK SHALL BE PERFORMED IN ACCORDANCE TO THIS CODE, AND LOCAL REQUIREMENTS. <br />2. GRAVITY LOADS: <br />ROOF DEAD LOAD = 17 PSF <br />ROOF LIVE LOAD = 20 PSF <br />FLOOR DEAD LOAD = 15 PSF <br />FLOOR LIVE LOAD = 40 PSF <br />3. SEISMIC DESIGN PARAMETERS (GOVERNING THE DESIGN) <br />RISK CATEGORY = II <br />SITE CLASS = D <br />SEISMIC DESIGN CATEGORY = D <br />SS = 1303g <br />S, = 0.464g <br />Fa = 1.2 <br />SpS = 1.042g <br />SEISMIC RESISTING SYSTEM = LIGHT -FRAME (WOOD) WALLS SHEATHED WITH WOOD STRUCTURAL <br />PANELS RATED FOR SHEAR RESISTANCE <br />R = 6.5 <br />CS = 0.16 <br />ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE <br />REDUNDANCY FACTOR = 1.3 <br />4. WIND LOAD PARAMETER (NOT GOVERNING THE DESIGN) <br />WIND RISK CATEGORY =11 <br />WIND EXPOSURE = C <br />WIND SPEED = 95 MPH <br />SPECIAL INSPECTION NOTES <br />SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING ITEMS) PER CBC CHAPTER 17 <br />1. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR ADHESIVE ANCHORS INSTALLED <br />IN HARDENED CONCRETE MEMBER (CBC TABLE 1705.3). <br />SYMBOL LEGEND <br />NUMBER OF DETAIL HORIZONTAL STRAP <br />S# # MSTXX <br />SHEET WHERE DETAIL IS <br />DETAIL REFERENCE LOCATED <br />® VERTICAL STRAP <br />10, SIMPSON HDU HOLDOWN <br /># NUMBER OF DETAIL <br />S# # SHEET WHERE DETAIL IS <br />SECTION CUT LOCATED ###- BEAM OR HEADER <br /># NUMBER OF DETAIL LIMIT OF JOISTS OR RAFTER <br />S# # SHEET WHERE DETAIL IS <br />ELEVATION VIEW LOCATED DIRECTION OF JOISTS OR RAFTERS <br />NUMBER OF DETAIL <br />S#. <br />SHEET WHERE DETAIL IS <br />LOCATED <br />-_j <br />DETAIL CALLOUT <br /># SHEAR WALL TYPE <br />Is (PER SCHEDULE) <br />SW SHEAR WALL LENGTH <br />;;;SHEAR WALL DESIGNA11ON <br />SHEARWALL SYMBOL <br />ABBREVIATIONS <br />LIMIT OF JOISTS OR RAFTER <br />DIRECTION OF EXISTING JOISTS OR <br />EXISTING RAFTERS <br />@ <br />AT <br />TOT <br />TOTAL <br />B.N. <br />BOUNDARY NAILING <br />LINO <br />UNLESS NOTED OTHERWISE <br />BM <br />BEAM <br />W/ <br />WITH <br />CENTER LINE <br />W/0 <br />WITHOUT <br />CLR <br />CLEAR <br />CBC <br />CALIFORNIA BUILDING CODE <br />DF <br />DOUGLAS-FIR LARCH <br />DIA <br />DIAMETER <br />EQ <br />EQUAL <br />E <br />EXISTING <br />FG <br />FINISH GRADE <br />FT <br />FOOT <br />HDR <br />HEADER <br />IN <br />INCH <br />Le <br />BOLT EMBEDMENT <br />MAX <br />MAXIMUM <br />N <br />NEW <br />MIN <br />MINIMUM <br />O.C. <br />ON CENTER <br />PSF <br />POUND PER SQUARE FOOT <br />PLF <br />POUND PER LINEAR FOOT <br />SQ.FT. <br />SQUARE FOOT <br />SIM <br />SIMILAR <br />TYP <br />TYPICAL <br />Ir <br />ningpffm� 8u <br />Om <br />A00ox - Aff <br />R I%VC <br />T <br />EXCEPT THE I,QRD GUILD THE NDUS <br />THEY LABC 14 VAIN TNAT 10110 17 <br />M ter 16" RIMPAU "[, SUITE 210 <br />CORONA, C A MN <br />Date,: lei. ( fl560-1385 <br />eolioeeriogsolutioos,info@lmoil.com <br />Drawings and written material appearing herein constitute <br />original and unpublished work of ES Egineering Solutions and <br />may not be duplicated used or disclosed without written <br />consent of ES Engineering Solutions. <br />eWESS/441 <br />� c <br />George F Endrawes <br />w m <br />O C915o6$ <br />1 1 <br />PROJECT: <br />GARAGE CONVERSION <br />TO ADUs <br />PROJECT ADDRESS: <br />1313 N SPURGEON ST. UNIT A-H, <br />SAN TA AN A, CA 92701 <br />1322 FRENCH ST, <br />SANTA ANA, CA 92701 <br />No. Date Issue <br />Project No. 282023 <br />scale NOTED <br />Drawing Title STRUCTURE NOTES <br />DESIGNED BY: G.E. <br />CHECKED BY: <br />DATE: <br />11/12/2025 <br />Drawing No <br />so"o <br />