My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1313 N Spurgeon St Unit A-H & 1322 N French St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spurgeon St
>
1313 N Spurgeon St Unit# A
>
1313 N Spurgeon St Unit A-H & 1322 N French St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:04:01 AM
Creation date
2/13/2026 5:01:15 AM
Metadata
Fields
Template:
Plan
Permit Number
20185200
20185201
20185202
20185203
20185204
20185205
20185206
20185207
20185208
30148417
30148418
30148419
30148420
30148421
30148422
30148423
30148424
30148425
40140047
40140048
40140049
40140050
40140051
40140052
40140053
40140054
40140055
101122523
101122524
101122525
101122526
101122527
101122528
101122529
101122531
101122532
101122533
101122534
Full Address
1313 N Spurgeon St Unit# A
1313 N Spurgeon St Unit# B
1313 N Spurgeon St Unit# C
1313 N Spurgeon St Unit# D
1313 N Spurgeon St Unit# E
1313 N Spurgeon St Unit# F
1313 N Spurgeon St Unit# G
1313 N Spurgeon St Unit# H
1322 N French St
1313 N Spurgeon St
Street Number
1313
Street Direction
N
Street Name
Spurgeon
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Standard CM U Block Wall Detail <br />The purpose of this Information Bulletin is to assist owners and builders who may choose to erect <br />simple freestanding concrete masonry unit (CM U) block walls using the Department's standard <br />detail. This Information Bulletin provides general requirements and specifications for the construc- <br />tion of standard CM U block walls of various height, thickness or footing configurations. These walls <br />are designed for the average condition and may not be suitable in all cases. Where the proposed <br />wall construction is located on a site with slope steeper than 10%, with adverse soil conditions (e.g., <br />expansive soil, liquefaction, flood hazard, etc.) or deviates from this Information Bulletin, a registered <br />design professional licensed in the State of California should be consulted. <br />TO DETERMINE HEIGHT FOR <br />BUILDING CODE PURPOSES, <br />"H" IS MEASURED FROM <br />TOP OF FOOTING TO TOP <br />OF WALL CAP. <br />TO DETERMINE HEIGHT FOR <br />ZONING CODE PURPOSES, <br />SEE GENERAL ZONING <br />REQUIREMENTS. <br />ALL UNIT CELLS THAT HAVE <br />HORIZONTAL OR VERTICAL <br />REBARS SHALL BE GROUTED <br />24" LAP <br />Llnl. (TYP) <br />U <br />101110W <br />�— MORTAR OR MASONRY CAP. �- <br />HORIZONTAL REBAR AT TOP. <br />SEE TABLE FOR REBAR SIZE. <br />IA LOCATE VERTICAL REBAR AT <br />CENTER OF WALL. SEE TABLE <br />FOR REBAR SIZE. <br />H WHERE H a 4'-G", HORIZONTAL H <br />REBAR AT MID -WALL HEIGHT <br />IS REQUIRED. SEE TABLE FOR ~` <br />REBAR SIZE. <br />NO. 4 VERTICAL DOWELS WITH I <br />I� ALTERNATE BENDS. 24" 1 AP <br />MIN. (TYP) <br />2d" LAP <br />1.11N. (TYP) <br />- - —Illy <br />UNDISTURBED' SOIL UNDISTURBED SOIL- III <br />1I11M ITI-III I...... <br />T D -'� �IT ID D <br />3" CLR. PAIN. I'f.— 3" CLR. MIN, L L 14 <br />j • 3" CLR. MIN. <br />W CONTINUOUS 4BARS W 1#4BAR W <br />CONTINUOUS <br />"L." TYPE FOUNDATION "T" TYPE FOUNDATION "I" TYPE FOUNDATION <br />GENERAL ZONING REQUIREMENTS: <br />For zoning code purposes, fence height shall be measured from grade adjoining the fence on the <br />public right-of-way side of the fence and/or from the average grade of both sides of the fence be- <br />tween two private properties. For lots that slope more than 5'-0" from front to rear, contact a Plan- <br />ning staff at the Development Services Center to help establish the fence height. A 6'-0" corner <br />cutoff may be required for fencing adjacent to driveways and sidewalks that obstruct visibility. <br />1 of 2 <br />Standard CM U Block Wall Detail <br />WALL <br />HEIGHT <br />T' TYPE FOUNDATION <br />"T" TYPE FOUNDATION <br />"I" TYPE <br />FOUNDATION <br />VERTICAL REBAR <br />HORIZ. <br />REBAR <br />W <br />D <br />T <br />W <br />D <br />T <br />W <br />D <br />3'- 6" <br />18" <br />18" <br />9" <br />14" <br />12" <br />6" <br />12" <br />22" <br />#4 Rebar @ 48" o.c. <br />#4 Rebar <br />4' - 6" <br />18" <br />18" <br />9" <br />18" <br />12" <br />6" <br />12" <br />26" <br />#4 Rebar @ 48" o.c. <br />#4 Rebar <br />5' - 6" <br />24" <br />24" <br />12" <br />22" <br />12" <br />6" <br />12" <br />30" <br />#4 Rebar @ 48" o.c. <br />#4 Rebar <br />6'- 6" <br />24" <br />24" <br />12" <br />26" <br />14" <br />6" <br />12" <br />36" <br />#4 Rebar @ 24" o.c. <br />#4 Rebar <br />GENERAL BUILDING REQUIREMENTS: <br />Wall over 4'-0" in height measured from the bottom of the footing to the top of the wall shall require <br />a building permit. Foundation must be poured against undisturbed soil with no appreciable slope of <br />sidewalls. All horizontal and vertical reinforcements shall maintain a min. 3" clearance from the bot- <br />tom and sides of the trench. Horizontal bond beam reinforcement is required to be located in the 2nd <br />course from the top of the wall. Prefabricated joint reinforcement in each two top mortar joints consist- <br />ing of two No. 9 gage galvanized wires with No. 9 gage steel welded cross wires spaced a max. 16" <br />o.c. may be substituted for the horizontal bond beam reinforcement in the top of walls 5'-6" or less in <br />heights. All wires shall be thoroughly embedded in the bed joint mortar and lapped a min. of 12". Units <br />shall be staggered (common bond are not permitted) and may be partially grouted with grout confined <br />to those cells that have horizontal and vertical reinforcing steel. <br />SPECIFICATIONS: <br />Min. 2,500 psi strength in 28 days. Mix for concrete footing to be 1 part ce- <br />Concrete: <br />ment to 2-1/2 parts sand to 3-1/2 parts gravel with a max. of 7-1/2 gallons of <br />water per sack of cement. <br />Block: <br />Grade "N" ASTM C 90-03. Nominal width of units shall be a min. 6". <br />Reinforcement: <br />Deformed steel bar conforming to ASTM A-615 Grade 40 or Grade 60. <br />Mortar (Type "S") <br />Mix to be 1 part cement to 1 /2 part lime to 3 parts damp loose sand. <br />Mix to be 1 part cement to 3 parts sand to max. 1 /10 part lime. Sufficient water <br />Grout: <br />should be added to produce consistency for pouring without segregation of the <br />constituents. May contain 2 parts pea gravel (max. size 3/8"). <br />INSPECTIONS: <br />Foundation Insp.: When trench is ready for concrete and all steel reinforcements are tied in place. <br />Pre -Grout Insp.: When first horizontal bar and all vertical bars are in place, but not grouted! <br />Final Insp.: After wall is grouted and cap is installed <br />COMMON PROPERTY FENCE WALL: <br />Where a common property fence wall is requested, a completed and signed "Common Property Wall <br />Line Agreement and Maintenance" form by all of the common property owners is required prior to ap- <br />proval of the 1 st inspection (i.e., foundation inspection). <br />2of2 <br />IN <br />nnui <br />EXCEPT 1il t10 BUILD THE HDUI <br />71'IFV I41i: 14 VAIN 44AT &UIID IT <br />genpy I <br />M ter Ib�� RIUPAU AVE, so"[ 110 <br />CORONA, C A 92819 <br />Date: 1eL �Hfl560-1385 <br />eogioeeriogsoluliaos.iofo@gmail.com <br />Drawings and written material appearing herein constitute <br />original and unpublished work of IS Egineering Solutions and <br />may not be duplicated used or disclosed without written <br />consent of IS Engineering Solutions. <br />eWESS/ONg1 <br />� c <br />r_- George F EndrawesOf <br />w m <br />C91685 <br />0 <br />PROJECT: <br />E111010.11-5101 <br />0 <br />GARAGE CONVERSION <br />TO ADUs <br />PROJECT ADDRESS: <br />1313 N SPURGEON ST. UNIT <br />SAN TA AN A, CA 92701 <br />1322 FRENCH ST, <br />SANTA ANA, CA 92701 <br />No. Date Issue <br />Project No. 282023 <br />scale NOTED <br />Drawing T i t I e: STRUCTURE DETAILS <br />DESIGNED BY: G.E. <br />CHECKED BY: <br />DATE: <br />11/12/2025 <br />Drawing No <br />S3(,2 <br />A- H, <br />
The URL can be used to link to this page
Your browser does not support the video tag.