Laserfiche WebLink
PAGE <br />REV: A1 9/17/2024 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />KIM HA NGUYEN <br />1227 W RIVER LN, SANTA ANA, <br />CA, 92706 <br />PROJECT NUMBER: <br /> SC1800916342 <br />SHEET <br />DESIGNER: <br />FRENCE RETONE <br />CUSTOMER RESIDENCE: <br />TEL. (714) 675-1274 <br />APN: 00113716 <br />GILBERT CORREIA, C10, C46 <br />CA CL #750184 <br />(415) 580-6920 ex3 <br />SIGNAGE <br />PV-5.0 <br />#ESTAMP <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2013 CEC ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR <br />IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />WARNING! <br />SOURCES: UTILITY GRID <br />AND PV SOLAR ELECTRIC <br />SYSTEM <br />DUAL POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): CEC 2016: 705.12(D)(3), <br />NEC 2014: 705.12(D)(3), NEC 2011: <br />705.12(D)(4) <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2016: 690.31(G)(3), 690.31(G)(4), NEC <br />2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), <br />690.31(E)(4), IFC 2012: 605.11.1.4 <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH <br />RAPID SHUTDOWN <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12, IFC <br />2012: 605.11.1 <br />PHOTOVOLTAIC DC DISCONNECT <br />RATED MAXIMUM POWER-POINT CURRENT: <br />RATED MAXIMUM POWER-POINT VOLTAGE: <br />MAXIMUM SYSTEM VOLTAGE: <br />MAXIMUM SHORT CIRCUIT CURRENT: <br />ADC <br />VDC <br />VDC <br />ADC <br />25.96 <br />218.47 <br />280.32 <br />34.68 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): CEC 2016: 690.53, NEC 2014: 690.53, NEC <br />2011: 690.53 <br />INVERTER 1 <br />ELECTRICAL SHOCK HAZARD <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2016: 690.17(E), NEC <br />2014: 690.17(E), NEC 2011: 690.17(4) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH <br />PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12, <br />NEC 690.56, IFC 2012: 605.11.1 <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECTS. <br />PER CODE(S): CEC 2016: 690.35(F), NEC <br />2014: 690.35(F), NEC 2011: 690.35(F) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2016: <br />705.12(D)(2)(3)(c), NEC 2014: <br />705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 20 AMPS <br /> 240 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2016: 690.54, NEC 2014: 690.54, NEC <br />2011: 690.54 <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2016: <br />705.12(D)(2)(3)(b), NEC 2014: <br />705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) <br />POWER TO THIS BUILDING IS <br />ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH <br />DISCONNECTS AS SHOWN <br />CAUTION: <br />1227 W RIVER LN, SANTA ANA, CA, 92706 <br />SOLAR PANELS ON ROOF <br />SERVICE ENTRANCE AND PV <br />BREAKER DISCONNECT <br />AC DISCONNECT <br />SUNRUN METER <br />INVERTER (EXT) <br />RAPID SHUTDOWN SWITCH