Laserfiche WebLink
SHEET REFERENCE: <br />SHEET: OF <br />SHEET INFO: <br />REVISION DATE: <br />ME <br />R <br />C <br />U <br />R <br />Y <br /> <br />I <br />N <br />S <br />U <br />R <br />A <br />N <br />C <br />E <br />, <br /> <br />I <br />N <br />C <br />. <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />CL <br />I <br />E <br />N <br />T <br />: <br />CA <br />H <br />O <br />- <br />0 <br />0 <br />2 <br />5 <br />0 <br />9 <br />9 <br />4 <br />SHEET TITLE: <br />JE <br />R <br />R <br />Y <br /> <br />N <br />G <br />O <br />JOB NO. <br />SCALE: <br />DATE: <br />DESIGNER: BS <br />25-0001 <br />01/17/25 <br />DRAFTER: AG <br />PR <br />O <br />P <br />E <br />R <br />T <br /> <br />C <br />L <br />A <br />I <br />M <br />S <br /> <br />A <br />D <br />J <br />U <br />S <br />T <br />E <br />R <br />10 <br />4 <br />8 <br /> <br />I <br />R <br />V <br />I <br />N <br />E <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />1 <br />0 <br />8 <br />7 <br />NE <br />W <br />P <br />O <br />R <br />T <br /> <br />B <br />E <br />A <br />C <br />H <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />6 <br />0 <br />PH <br />O <br />N <br />E <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />2 <br />5 <br />9 <br />- <br />6 <br />0 <br />8 <br />0 <br />BR <br />Y <br />A <br />N <br />@ <br />S <br />T <br />R <br />E <br />G <br />E <br />S <br />T <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br />. <br />C <br />O <br />M <br />ST <br />R <br />E <br />G <br />E <br />S <br />T <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br />. <br />C <br />O <br />M <br />12 <br />2 <br />2 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />L <br />I <br />N <br />D <br />A <br /> <br />W <br />A <br />Y <br />213 <br />S-3 <br />SPECIFICATIONS <br />SHEET 3 <br />CONCRETE <br />REINFORCEMENT <br />WOOD (CONTINUED) <br />WOOD FRAMING CONNECTORS <br />1. ALL WOOD FRAMING CONNECTORS SHALL BE SIMPSON "STRONG-TIE" OR <br />MITEK/USP (OR EQUIVALENT). INSTALLATION PROCEDURES AHALL BE IN <br />ACCORDANCE WITH MANUFACTURED PRODUCT AND CURRENT <br />INSTRUCTION MANUAL/CATALOG. <br />CONNECTOR CODE REPORT REFERENCE: <br />SIMPSON PRODUCT MITEK.USP PRODUCT SUBSTITION <br />ITEM ICC-ES IAPMO LARR- ITEMESR-IAPMO LARR-ESR- <br />ICC-ES <br />A35/LTP4 2606 - 25716 MPA1/MP_F 3455 - 25745 <br />LTP5 - ER-112 25814 MP_F 3455 - 25745 <br />CBSQ - - - - - -LEGACY <br />ER-5952 <br />CCQ/ECCQ/AC/ACE <br />CMST/CMSTC/CS/ST/ <br />MST/MSTA <br />HTT <br />IUS <br />MASA <br />PA/HPA/PAI/MPAI <br />U/HU/HUC <br />HUCQ <br />HDU/HDQ/HHDQ <br />SDS <br />SSTB <br />PB <br />PC <br />2604 <br />2330 <br />- <br />2552 <br />2555 <br />2604 <br />2236 <br />2611 <br />2549 <br />2552 <br />2105 <br />LEGACY <br />ER-5708 <br />LEGACY <br />NER-443 <br />- <br />- <br />- <br />- <br />- <br />ER-130 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />25713 <br />- <br />- <br />25714 <br />25720 <br />25818 <br />25801 <br />25851 <br />25714 <br />25711 <br />25827 <br />25807 <br />25801 <br />KCCQ/KECCQ/PBS/PBES <br />PHDA/PHD/UPHD <br />HTT <br />THF MAX <br />FA4 <br />CMST/CMSTC/RS/ST/ <br />KST/MSTA <br />PCM <br />WS <br />STB <br />SUH/HD/HDIF <br />3449 <br />3455 <br />3847 <br />3445 <br />2787 <br />3449 <br />2761 <br />2266 <br />3445 <br />- <br />ER-0200 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />25779 <br />25954 <br />26048 <br />25843 <br />26017 <br />25779 <br />25850 <br />25992 <br />25843 <br />25745 <br />2. MINIMUM NAILING TO CONNECT WOOD MEMBERS SHALL BE AS <br />SPECIFIED IN CBC TABLE 2304.10.1. <br />3. PLATE NAILING FROM BLOCKING TO WALL TOP PLATE SHALL BE 16D <br />COMMON AT 8 INCHES ON-CENTER MAXIMUM UNLESS NOTED <br />OTHERWISE ON SHEAR WALL SCHEDULE. <br />4. A COPY OF THE JURISDICTION RESEARCH REPORT AND/OR CONDITIONS <br />OF LISTING, IF ANY SHALL BE MADE AVAILABLE AT THE JOB SITE. <br />5. SOLE PLATE NAILING FROM WALL SOLE PLATE TO JOIST OR BLOCKING <br />BELOW SHALL BE 16D COMMON AT 8 INCHES ON-CENTER MAXIMUM <br />UNLESS NOTED OTHERWISE ON SHEAR WALL SCHEDULE. <br />6. DEPUTY INSPECTION IS REQUIRED FOR ALL HOLD DOWN ANCHOR BOLTS. <br />7. ALL HOLD DOWN ANCHOR NUTS SHALL BE TIGHTENED JUST PRIOR TO <br />COVERING WALL FRAMING. (LEAVE ENOUGH SPACE BETWEEN THE SILL <br />AND THE HD TO ALLOW FOR SOME SLIP AT POST CONNECTION WHEN <br />TIGHTENING). HOLD DOWN CONNECTOR BOLTS INTO WOOD FRAMING <br />REQUIRE APPROVED PLATE WASHER THAT IS IN ACCORDANCE WITH THE <br />LOCAL JURISDICTION. <br />8. FOR LAG BOLTS: PROVIDE LEAD HOLES 40% TO 70% OF SHANK DIA. AND <br />FULL DIA, FOR SHANK PORTION. SOAP, PARAFFIN, OR OTHER APPROVED <br />LUBRICANT SHALL BE USED ON THREADS. INSTALLATION SHALL BE BY <br />SCREWING, NO HAMMERING. CARE SHALL BE TAKEN TO AVOID OVER <br />TORQUING OF THE BOLT. <br />9. ALL MULTI-STUDS ARE TO BE LAMINATED WITH 16D AT 8" O.C. <br />10. ALL BALLOON FRAMED WALLS SHALL BE BRACED TO CONFORM TO CBC <br />TABLE 2308.5.1. <br />11. PROVIDE PRE-DRILLING WHERE NECESSARY TO AVOID SPLITTING. <br />12. ONLY COMMON NAILS SHALL BE USED FOR ALL WOOD SHEAR WALLS <br />AND SHEAR TRANSFER CONNECTIONS. NAIL GUNS USING "CLIPPED <br />HEADS" OR "SINKER" NAILS ARE NOT ACCEPTABLE. <br />13. PROVIDE MINIMUM OF 1/2" EDGE DISTANCE FOR ALL PLYWOOD <br />BOUNDARY NAILING IN SHEAR WALLS, ALL PLYWOOD EDGES SHALL BE <br />BLOCKED. MIN. WIDTH OF BLOCKING TO RECEIVE PLYWOOD NAILING <br />MUST NOT BE LESS THAN THE THICKNESS OF BOUNDARY MEMBER AS <br />SPECIFIED ON SHEAR WALL SCHEDULE. <br />14. OMIT SHEATHING B.N. UNDER CMST STRAP. INSTALL CMST OVER <br />SHEATHING, U.N.O. <br />15. TOE NAILING SHALL NOT BE USED IN A SHEAR CONNECTION. <br />16. HOLD DOWN ANCHORS MUST BE TIED IN PLACE PRIOR TO FOUNDATION <br />INSPECTION. <br />STRUCTURAL STEEL & METAL <br />1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE LATEST AISC SPECIFICATIONS AND THE CODE <br />OF STANDARD PRACTICE. LICENSED FABRICATORS SHALL BE APPROVED <br />BY THE JURISDICTION. <br />2. ALL STEEL EXCEPT PIPE, TUBE & W ASTM A-36 <br />PIPE ASTM A-53, TYPE E / S, GRADE B <br />ROUND HSS ASTM A-500, GRADE B <br />RECTANGULAR HSS ASTM A-500, GRADE B <br />W-SHAPE ASTM A-992 <br />3. BOLTS <br />x HIGH STRENGTH BOLTS ASTM A325 <br />x ALL OTHER BOLTS ASTM A307 <br />4. THREADED RODS <br />x HIGH STRENGTH RODS ASTM A193 GR. B7 OR A449 <br />x ALL OTHER RODS ASTM A36 <br />5. ANCHOR RODS <br />x HIGH STRENGTH ASTM A193 GR. B7 OR ASTM A449 <br />x ALL OTHER RODS ASTM A307 OR ASTM F1554 GR.36 <br />6. BOLT HOLES <br />x MINIMUM EDGE DISTANCE AISC TABLE J3.5 <br />x MINIMUM SPACING 3 BOLT DIAMETER <br />x HIGH STRENGTH BOLTS FRICTION TYPE W/ CLASS A <br />FAYING SURFACE <br />7. MINIMUM FILLET WELD AISC TABLE J2.4 <br />8. ALL FIELD WELDING TO BE CONTINUOUSLY INSPECTED BY A SPECIAL <br />INSPECTOR QUALIFIED IN WELDING. FIELD WELDERS MUST BE <br />APPROVED BY THE JURISDICTION. <br />9. ALL SHOP WELDS SHALL BE PERFORMED BY A LICENSED FABRICATOR'S <br />SHOP APPROVED BY THE JURISDICTION. <br />10. ALL UNEXPOSED STEEL STEEL STRUCTURES PAINTING <br />COUNCIL SPECIFICATION 15-687 <br />11. EXPOSED STEEL GALVANIZED <br />12. EXPANSION BOLTS (RED HEAD) ICC RESEARCH <br />RECOMMENDATION #1821 <br />13. SELF-DRILLING ANCHORS ICC RESEARCH <br />RECOMMENDATION #1372 <br />14. POWDER ACTUATED FASTENERS 0.145" DIAM. PER ICC-ES <br />ESR-2379 (COLA RR#25708) <br />(HILTI OR APPROVED EQ.) <br />0.157" DIAM. PER ICC-ES <br />ESR-2269 (COLA RR#25675) <br />(HILTI OR APPROVED EQ.) <br />15. ALL WALLS SHALL HAVE FASTENERS PLACED AT 6" FROM ENDS OF SILL <br />PLATES. INSTALL PER ICC REPORT REQUIREMENTS & MANUFACTURER'S <br />RECOMMENDATIONS. <br />16. LIGHT GAGE COLD-FORMED STEEL MEMBERS SHALL CONFORM TO <br />ASTM-A-441, U.N.O. <br />17. WHERE HIGH-STRENGTH (H.S.) BOLTS ARE SPECIFIED ON THE PLANS, <br />THEY SHALL BE FRICTION TYPE CONFORMING TO ASTM A 325 (SC) WITH A <br />CLASS A FAYING SURFACE. THERE SHALL BE NO PAINT, OIL, LACQUER OR <br />GALVANIZING ON THE CONTACT SURFACES. <br />18. ALL GROUT UNDER STEEL BEARING PLATES SHALL BE SOLID DRYPACK <br />OR NON-SHRINK GROUT. F'c=4,000 PSI. <br />19. METAL FLOOR DECK: FLOOR:PLN (CATALOG VF2-P.90) <br />ROOF:PLN-24 (CATALOG VR1-P.29) <br />MFR. BY VERCO MANUFACTURING CO. <br />(ASTM A-653, LARR #23789) <br />STRUCTURAL STEEL & METAL (CONTINUED) <br />CONCRETE QUALITY: SHALL BE AS SHOWN BELOW: <br />CONCRETE USE (MIN.) <br />- <br />STRENGTH <br />(KSI) AT 28 <br />DAYS <br />SLUMP W/C RATIO <br />(MAX.) <br />FLY ASH <br />(% MAX.) <br />MAX <br />AGGREGATE <br />MAX. <br />SHRINKAGE <br />% <br />- - - - - - <br />GENERAL NOTES: <br />*USE f 'c=4500 PSI TYPE V CONCRETE WITH WATER CEMENT RATIO=0.45 IF <br />CONCRETE IS PLACED IN EXPOSURE CLASS S2 OR S3 <br />**SHRINKAGE CHARACTERISTIC SHALL MEET OR EXCEED SLAB LEVEL MIX <br />DESIGN. <br />CONCRETE WEIGHT: ALL CONCRETE SHALL BE REGULAR WEIGHT OF 145 <br />POUNDS PER CUBIC FOOT UNLESS NOTED OTHERWISE. MAXIMUM IN-PLACE <br />DENSITY OF NON-STRUCT. LIGHTWEIGHT CONCRETE FLOOR TOPPING IS TO BE <br />100#/CU.FT. <br />AGGREGATE: SIZE OF AGGREGATE SHALL CONFORM TO ASTM C33-85 <br />3/4" ASTM SIZE #67 <br />1" ASTM SIZE #57 <br />1.1/2" ASTM SIZE #4 <br />CEMENT: PORTLAND CEMENT SHALL CONFORM TO ASTM C150 TYPE II, U.N.O. <br />CONCRETE AGE: NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN <br />CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY <br />TESTING AGENCY. <br />WET SET: REINFORCEMENT MAY NOT BE WET SET IN CONCRETE POURS. <br />INSERTS: ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, <br />DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY <br />POSITIONED IN THE FORMS BEFORE PLACING OF CONCRETE. <br />ROUGHENED SURFACES: WHERE INDICATED ON THE DRAWINGS, ROUGHENED <br />SURFACES SHALL BE PROVIDED BY MEANS OF HEAVY RAKING OR GROOVING. <br />OTHER METHODS MAY BE ACCEPTABLE PENDING WRITTEN DIRECTION BY THE <br />ENGINEER. ALL INTERFACING SURFACES MUST BE CLEAN AND FREE OF LOOSE <br />MATERIALS. <br />ADMIXTURES: NO ADMIXTURES SHALL BE ADDED TO THE CONCRETE MIX <br />WITHOUT THE WRITTEN DIRECTION OF THE ENGINEER, UNLESS NOTED <br />OTHERWISE. <br />CHLORIDES: GROUT OR CONCRETE CONTAINING CHLORIDES SHALL NOT BE <br />USED. <br />DEBRIS: REMOVE ALL DEBRIS FROM FORMS BEFORE POURING. <br />SEGREGATION OF AGGREGATES: CONCRETE SHALL NOT BE DROPPED <br />THROUGH REINFORCING STEEL (AS IN WALLS, COLUMNS AND DROP CAPITALS) <br />SO AS TO CAUSE SEGREGATION OF AGGREGATES. USE HOPPERS, CHUTES OR <br />TRUNKS OF VARYING LENGTH SO THAT THE FREE UNCONFINED FALL OF <br />CONCRETE SHALL NOT EXCEED SIX FEET, AND A SUFFICIENT NUMBER SHALL <br />BE USED TO ENSURE THAT THE CONCRETE IS KEPT LEVEL AT ALL TIMES. <br />CONSTRUCTION JOINTS: THE CONTRACTOR SHALL OBTAIN THE ENGINEER'S <br />APPROVAL OF CONSTRUCTION JOINT LOCATION IN SLABS AND BEAMS. <br />SPLICES: SPLICE BARS IN MEMBERS SUCH AS SPANDRELS, BEAMS, ETC., AS <br />FOLLOWS: TOP BARS AT CENTERLINE OF SPAN, BOTTOM BARS AT THE <br />SUPPORT. ALL REINFORCING STEEL SHALL BE SECURELY WIRED AND <br />PROPERLY SUPPORTED ABOVE GROUND AND AWAY FROM THE FORMS. DRAG <br />REINF TO HAVE TYPE II MECH CONNECTOR, U.N.O. ON PLANS. <br />TEMPERATURE AND SHRINKAGE REINFORCEMENT: SHALL HAVE A LAP OF <br />THIRTY (30) BAR DIAMETERS, BUT NOT LESS THAN 18 INCHES, AND THE <br />SPLICES IN ADJACENT BARS SHALL BE OFFSET NOT LESS THAN FIVE (5) FEET <br />APART. <br />REBAR GRADES: ALL REINFORCING STEEL SHALL BE NEW STOCK DEFORMED <br />BARS CONFORMING TO ASTM A615 AS FOLLOWS: <br />#3 & SMALLER BARS GRADE 40, U.N.O. <br />#4 & LARGER BARS GRADE 60, U.N.O. <br />REBAR COVER: MINIMUM REBAR COVER FOR CONCRETE SHALL BE AS SHOWN <br />IN THIS TABLE, U.N.O. <br />REINFORCEMENT (CONTINUED) <br />TOLERANCE (±)MINUMUM <br />COVEREXPOSURE CONDITION <br />CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3.0 3/8" <br />EXPOSED TO EARTH OR WEATHER: <br />NO. 5 AND SMALLER BARS <br />NO. 6 AND LARGER BARS <br />1.1/2" <br />2" <br />1/4" <br />1/4" <br />NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND: <br />ROOF SLAB <br />STRUCTURAL SLABS & WALLS <br />STRUCTURAL SLABS (RATED ASSEMBLY) <br />MID SPAN <br />END SPAN <br />BEAMS AND COLUMNS (COVER TO TIES, STIRRUPS & SPIRALS) <br />SLAB ON GRADE 1.1/2" 1/4" <br />1" <br />1" <br />SEE SLAB <br />NOTES <br />1.1/2" <br />1/8" <br />1/8" <br />1/8" <br />1/8" <br />1/8" <br />1/8" <br />TOLERANCES FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF <br />REINFORCEMENT SHALL BE ± TWO (2) INCHES, EXCEPT AT DISCONTINUOUS <br />ENDS OF MEMBERS WHERE TOLERANCES SHALL BE ± 1/2 INCH. <br />STRUCTURAL OBSERVATION <br />1. WHEN REQUIRED BY THE CODE, OWNER OR THE OWNER'S AUTHORIZED <br />AGENT SHALL EMPLOY A REGISTERED DESIGN PROFESSIONAL TO <br />PERFORM STRUCTURAL OBSERVATIONS AS DEFINED IN CBC SECTION <br />1702 AND 1704.6. <br />2. STRUCTURAL OBSERVER SHALL PERFORM VISUAL OBSERVATION OF THE <br />STRUCTURAL SYSTEM AT SIGNIFICANT CONSTRUCTION STAGES AND AT <br />COMPLETION OF THE STRUCTURAL SYSTEM. <br />3. AT THE CONCLUSION OF THE WORK INCLUDED IN THE PERMIT, THE <br />STRUCTURAL OBSERVER SHALL SUBMIT TO THE BUILDING OFFICIAL A <br />WRITTEN STATEMENT THAT THE SITE VISITS HAVE BEEN MADE AND <br />IDENTIFY ANY REPORTED DEFICIENCIES THAT, TO THE BEST OF THE <br />STRUCTURAL OBSERVER'S KNOWLEDGE, HAVE NOT BEEN RESOLVED. <br />4. STRUCTURAL OBSERVATION PROGRAM <br />WOOD CONSTRUCTION - PRIOR TO COVERING TO WOOD FRAMING, <br />REPRESENTATIVE SECTIONS OF THE FOLLOWING ARES TO BE <br />OBSERVED: <br />x CONCRETE EMBEDS SUCH AS HOLD DOWN ANCHORS AND ANCHOR <br />BOLTS <br />x SHEAR WALL <br />x HOLD DOWN CONNECTIONS BETWEEN FLOORS <br />x BLOCKED FLOOR/ROOF DIAPHRAGM NAILING <br />CONCRETE AND MASONRY CONSTRUCTION - PRIOR TO CONCRETE <br />PLACEMENT, REPRESENTATIVE SECTIONS OF THE FOLLOWING AREAS TO <br />BE OBSERVED: <br />x GRADE BEAM AND ITS REINFORCEMENT <br />x CONCRETE/MASONRY SHEAR WALL REINFORCEMENT <br />x P.T. LAYOUT/SLAB REINFORCEMENT <br />SPECIAL INSPECTION <br />1. REFER TO SECTION 1702 OF BUILDING CODE FOR DEFINITION OF WORDS <br />AND TERMS. <br />2. OWNER'S RESPONSIBILITY <br />THE OWNER AND THE OWNER'S AUTHORIZED AGENT, OTHER THAN <br />THE CONTRACTOR (THE CONTRACTOR IS PERMITTED WHERE THE <br />CONTRACTOR IS ALSO THE OWNER), SHALL EMPLOY ONE OR MORE <br />APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND <br />TESTS DURING CONSTRUCTION ON THE TYPES OF WORK <br />SPECIFIED BELOW AND IDENTIFY THE APPROVED AGENCIES TO <br />THE BUILDING OFFICIAL. <br />3. CONTRACTOR'S RESPONSIBILITY <br />a. NOTIFY THE SPECIAL INSPECTOR IN ADVANCE FOR INDIVIDUAL <br />INSPECTIONS FOR ITEMS SPECIFIED ON THE APPROVED PLAN AND <br />ITEMS LISTED IN SECTIONS 1704 AND 1705. <br />b. RETAIN SPECIAL INSPECTION RECORDS AT JOB SITE AND PROVIDE <br />THESE RECORDS FOR REVIEW BY THE BUILDING DEPARTMENT <br />INSPECTOR UPON REQUEST. <br />c. SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY IN <br />ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN SECTION <br />1704.4, TO THE BUILDING OFFICIAL AND THE OWNER OR THE <br />OWNER AUTHORIZED AGENT PRIOR TO THE COMMENCEMENT OF <br />WORK. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY <br />SHALL CONTAIN ACKNOWLEDGEMENT OF AWARENESS OF THE <br />SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF <br />SPECIAL INSPECTIONS AND THE MINIMUM REQUIREMENT <br />SPECIFIED IN CBC CHAPTER 17. <br />4. APPROVED AGENCY'S RESPONSIBILITY <br />a. PERFORM ON-SITE PERIODIC AND CONTINUOUS INSPECTIONS FOR <br />CONFORMANCE WITH THE BUILDING DEPARTMENT APPROVED <br />PLANS AND PER THE REQUIREMENT SPECIFIED IN SECTION 1704 <br />AND 1705. <br />b. PERFORM PERIODIC AND CONTINUOUS INSPECTION FOR OFFSITE <br />FABRICATION OF STRUCTURAL MEMBERS. <br />EXCEPTION: SPECIAL INSPECTIONS ARE NOT REQUIRED FOR <br />OFF-SITE FABRICATION WORK PERFORMED ON PREMISES OF <br />A FABRICATOR REGISTERED AND APPROVED TO PERFORM <br />SUCH WORK WITHOUT SPECIAL INSPECTION. <br />c. MAINTAIN SPECIAL INSPECTION AND TEST RECORDS AND FURNISH <br />RECORDS TO CONTRACTOR, OWNER AND DESIGN PROFESSIONAL <br />IN RESPONSIBLE CHARGE. <br />d. BRING DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE <br />CONTRACTOR FOR CORRECTIONS. IF NOT CORRECTED IN A TIMELY <br />MANNER, BRING TO THE ATTENTION OF THE BUILDING OFFICIAL <br />AND THE DESIGN PROFESSIONALS PRIOR TO THE COMPLETION OF <br />THAT PHASE OF THE WORK. <br />e. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS <br />AND TESTS, AND CORRECTIONS OF ANY DISCREPANCIES NOTED IN <br />THE INSPECTIONS OR TESTS, SHALL BE SUBMITTED AT A POINT IN <br />TIME AGREED UPON PRIOR TO THE START OF WORK BY THE <br />OWNER OR THE OWNER'S AUTHORIZED AGENT TO THE BUILDING <br />OFFICIAL. <br />5. THE FOLLOWING WORK/ITEMS, IF CHECKED, MUST BE INSPECTED/ <br />VERIFIED BY THE APPROVED AGENCIES TO ENSURE THAT THE <br />WORKMANSHIP AND QUALITY OF WORK/ITEMS IS A CONFORMANCE WITH <br />THE DESIGN INTENT AND THE CORRESPONDING REFERENCED <br />STANDARD LISTED IN CHAPTER 17 OF THE BUILDING CODE. <br />CONCRETE CONSTRUCTION <br />TYPE SPECIAL <br />CONTINUOUS <br />INSPECTION <br />SPECIAL <br />PERIODIC <br />INSPECTION <br />INSPECT REINFORCEMENT, INCLUDING PRESTRESSING <br />TENDONS, AND VERIFY PLACEMENT X <br />REINFORCING BAR WELDING <br />x VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN <br />ASTM A706 <br />x INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16" <br />x INSPECT ALL OTHER WELDS <br />X <br />X <br />X <br />INSPECT ANCHORS CAST IN CONCRETE <br />INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE <br />MEMBERS: <br />x ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR <br />UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED <br />TENSION LOADS <br />x MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT <br />DEFINED AS ABOVE. <br />X <br />X <br />VERIFY USE OF REQUIRED DESIGN MIX X <br />PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR <br />STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, <br />AND DETERMINE THE TEMPERATURE OF THE CONCRETE. <br />X <br />INSPECT CONCRETE AND/OR SHOTCRETE PLACEMENT FOR <br />PROPER APPLICATION TECHNIQUES.X <br />VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND <br />TECHNIQUES.X <br />INSPECT PRE-STRESSED CONCRETE FOR: <br />x APPLICATION OF PRESTRESSING FORCES <br />x GROUTING OF BONDED PRESTRESSING TENDONS <br />X <br />X <br />VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF <br />TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO <br />REMOVAL OF SHORES AND FORMS FROM BEAMS AND <br />STRUCTURAL SLABS. <br />INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF <br />THE CONCRETE MEMBER BEING FORMED. <br />X <br />X <br />SPECIAL INSPECTION (CONTINUED) <br />SOILS INSPECTION <br />TYPE SPECIAL <br />CONTINUOUS <br />INSPECTION <br />SPECIAL <br />PERIODIC <br />INSPECTION <br />XVERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE <br />TO ACHIEVE THE DESIGN BEARING CAPACITY <br />XVERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE <br />REACHED PROPER MATERIAL <br />PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL <br />MATERIALS X <br />VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT <br />THICKNESSES DURING PLACEMENT AND COMPACTION OF <br />COMPACTED FILL <br />PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE <br />AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY X <br />X <br />WOOD FRAMING <br />TYPE SPECIAL <br />CONTINUOUS <br />INSPECTION <br />SPECIAL <br />PERIODIC <br />INSPECTION <br />(*) NAILING, BOLTING, ANCHOR AND OTHER FASTENING OF: <br />XxSHEAR WALL <br />XxBLOCKED FLOOR AND ROOF DIAPHRAGM <br />XxDRAG STRUT <br />XxSEISMIC BRACE <br />XxSHEAR PANEL <br />XxHOLD DOWN ASSEMBLY <br />X <br />HIGH LOAD DIAPHRAGM <br />x INSPECT THE WOOD STRUCTURAL PANEL SHEATHING TO <br />ASCERTAIN WHETHER GRADE AND THICKNESS IS AS SHOWN ON <br />APPROVED CONSTRUCTION DOCUMENTS. <br />x VERIFY THE NOMINAL SIZE OF FRAMING MEMBERS AT <br />ADJOINING PANEL EDGES, NAIL DIAMETER AND LENGTH, THE <br />NUMBER OF FASTENER LINES AND THAT THE SPACING <br />BETWEEN FASTENERS IN EACH LINE AND AT EDGE MARGINS <br />AGREES WITH THE APPROVED CONSTRUCTION DOCUMENTS. <br />(*) SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS <br />MORE THAN 4 INCHES ON CENTER. <br />(*) SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE SEISMIC FORCE-RESISTING SYSTEMS OF <br />STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY A OR B. <br />OTHER COMPONENTS <br />TYPE SPECIAL <br />CONTINUOUS <br />INSPECTION <br />SPECIAL <br />PERIODIC <br />INSPECTION <br />(**) ARCHITECTURAL COMPONENTS (INSTALLED 30' ABOVE GRADE <br />PLANE) ERECTION AND FASTENING OF: <br />XxEXTERIOR CADDING (IF > 5 PSF) <br />XxVENEER (IF > 5 PSF) <br />XxNON BEARING WALL (IF > 15 PSF) <br />MECHANICAL COMPONENTS - SEE MECHANICAL DRAWINGS AND <br />SPECS. <br />ELECTRICAL COMPONENT - SEE ELECTRICAL DRAWINGS AND SPECS. <br />(**) SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE SEISMIC FORCE-RESISTING SYSTEMS OF <br />STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY A, B, OR C. <br />GE <br />R <br />A <br />L <br />D <br /> <br />N <br />O <br />R <br />M <br />A <br />N <br />FI <br />E <br />L <br />D <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />C <br />L <br />A <br />I <br />M <br />S <br /> <br />S <br />P <br />E <br />C <br />I <br />A <br />L <br />I <br />S <br />T <br />NBG <br />#C 82777 <br />E