My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1144 S Clara St & 1142 S Clara St & #2 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Clara St
>
1142 S Clara St Unit# 2
>
1144 S Clara St & 1142 S Clara St & #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:11 AM
Creation date
2/13/2026 5:01:19 AM
Metadata
Fields
Template:
Plan
Permit Number
101119966
Full Address
1142 S Clara St Unit# 2
Street Number
1142
Street Direction
S
Street Name
Clara
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
12 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />DETAIL <br />DETAIL <br />DETAIL <br />DETAIL <br />CALIFORNIA PLUMBING CODE SECTION 507.2 REQUIRES THAT ALL WATER HEATERS SHALL BE <br />SUPPORTED AND STRAPPED TO PREVENT MOVEMENT DURING AN EARTHQUAKE <br />TWO METAL STRAP, NOT LESS THAN 22 GAUGE, NOT LESS THAN 5 <br />8 -INCH WIDE SHALL BE USED. <br />ONE STRAP SHALL BE PLACED WITHIN THE UPPER 1 <br />3 OF THE WATER HEATER'S VERTICAL <br />DIMENSION AND THE OTHER SHALL BE PLACED WITHIN THE BOTTOM 1 <br />3 OF THE WATER HEATER'S <br />VERTICAL DIMENSION. AT THE LOWER POINT, A MINIMUM DISTANCE OF 4 INCHES SHALL BE <br />MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING. THE PENETRATION OF 1-1/2-INCH <br />INTO A FRAMING MEMBER OF THE WALL.. A CUT WASHER SHALL BE USED BETWEEN THE HEAD <br />OF THE SCREW AND THE STRAP TO INSURE A POSITIVE SUPPORT <br />WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO THE STRUCTURE <br />18 <br />" <br />SAMPLE #1 <br />18 <br />" <br />SAMPLE #2 <br />STUD WALL <br />THIS 18-INCH STAND IS <br />REQUIRED FOR <br />HEATERS INSTALLED IN <br />A GARAGE LOCATION. <br />STUD WALL <br />THIS 18-INCH STAND IS <br />REQUIRED FOR <br />HEATERS INSTALLED IN <br />A GARAGE LOCATION. <br />DRILL PILOTS ON CENTERLINE <br />OF STUD; INSERT SCREWS <br />THROIGH PUNCHED HOLES IN <br />STRAP. <br />THESE TYPES OF SUPPORTS <br />ARE OVER-THE-COUNTER <br />PRODUCTS SOLD AS A <br />PACKAGES UNIT. <br />THIS STRAP IS INSTALLED 4 <br />INCHES ABOVE THE CONTROL <br />UNIT. <br />DRILL PILOTS ON CENTERLINE OF <br />STUD; INSERT SCREWS THROIGH <br />PUNCHED HOLES IN STRAP. <br />MINIMUM 22 GAUGE METAL <br />STRAP MATERIAL INSTALLED <br />WITHIN THE TOP 1 <br />3 OF THE <br />HEATER AND THE <br />BOTTOM 1 <br />3 OF THE HEATER. <br />THE LOWER STRAP IS INSTALLED <br />MINIMUM 4 INCHES ABOVE THE <br />CONTROL UNIT. MINIMUM <br />1/4-INCH SCREWS WITH <br />MINIMUM 1-1/2-INCH <br />PENETRATION ARE ALLOWED. <br />WATER HEATER STRAPPINGWATER HEATER HEAT PUMP <br />THIS WATER HEATER MUST BE INSTALLED INDOORS OUT OF THE WIND AND WEATHER. <br />THIS UNIT IS DESIGNED FOR ANY COMMON INDOOR INSTALLATION IN A SPACE WITH AT LEAST 10FT. x <br />10FT. x 7FT (700 FT³) INCLUDING: GARAGE, UTILITY ROOM, ATTIC, CLOSET, ETC. IT CAN BE INSTALLED IN <br />ROOMS SMALLER THAN 700 FT3 WITH THE INSTALLATION OF A LOUVERED DOOR, OR TWO LOUVERED <br />SECTIONS (ONE AT THE TOP AND ONE AT THE BOTTOM OF THE DOOR OR WALL FOR AIRFLOW). <br />TYPICAL INSTALLATION (DUCTLESS) <br />INSTALLATION WITH DUCTING KIT FOR A CONFINED SPACE <br />TO COMPLY WITH NSF REQUIREMENTS THIS WATER HEATER IS TO BE: <br />a)SEALED TO THE FLOOR WITH SEALANT, IN A SMOOTH AND EASILY CLEANABLE WAY, OR <br />b)INSTALLED WITH AN OPTIONAL LEG KIT THAT INCLUDES LEGS AND/OR EXTENSIONS THAT PROVIDE A <br />MINIMUM CLEARANCE OF 6” BENEATH THE WATER HEATER. <br />RECOMMENDED CLEARANCES <br />INSTALLATIONS IN A CONFINED SPACE, OR INSTALLATIONS WHERE THE RECOMMENDED SERVICE <br />CLEARANCES ARE NOT MET, WILL LEAD TO HIGHER POWER CONSUMPTION (INCREASED USE OF <br />RESISTANCE HEATING ELEMENTS AND/OR HEAT PUMP EFFICIENCY REDUCTION). <br />IT IS RECOMMENDED THAT THE REAR OF THE HEAT PUMP WATER HEATER BE FACED AWAY FROM ANY <br />WALLS TO ALLOW FOR EASIER INSTALLATION OF THE OUTLET ADAPTER AND OUTLET DUCT WORK. IN THE <br />EVENT THAT THIS IS NOT POSSIBLE, A MINIMUM OF 16” OF ADDITIONAL SPACE TO THE REAR OF THE <br />WATER HEATER AND 17” OF ADDITIONAL SPACE ABOVE THE WATER HEATER (NOT INCLUDING INLET AND <br />OUTLET) IS RECOMMENDED TO PROPERLY INSTALL THE DUCTING KIT. <br />TOTAL EQUIVALENT (STRAIGHT) DUCT WORK LENGTH OF THE INLET AND OUTLET DUCTING COMBINED MUST <br />BE LESS THAN 100 FEET. THE DIMENSION OF INSULATED FLEXIBLE DUCTING TO BE 8". <br />IT IS RECOMMENDED TO HAVE A 7” CLEARANCE BETWEEN ANY OBJECT AND THE REAR AND RIGHT SIDE OF <br />THE WATER HEATER IN THE EVENT SERVICE IS NEEDED. A MINIMUM 8” CLEARANCE ABOVE THE WATER <br />HEATER TO REMOVE THE FILTER FOR CLEANING AND FOR SERVICE ACCESS, AND CLEAR ACCESS TO THE <br />FRONT OF THE WATER HEATER, IS RECOMMENDED. <br />8" <br />7" <br />MODEL APPEARANCE MAY WAY <br />17" <br />6" <br />16" <br />A MINIMUM OF 17" OF <br />ADDITIONAL SPACE <br />ABOVE THE UNIT IS <br />RECOMMENDED. <br />A MINIMUM OF 16" <br />OF ADDITIONAL <br />SPACE TO THE <br />REAR OF THE UNIT <br />IS RECOMMENDED. <br />6" <br />MODEL APPEARANCE MAY WAY <br />6" <br />8" <br />Ø <br />8" <br />Ø <br />2" <br />MI <br />N <br />. <br />CORNER INSTALLATION (INDOOR) <br />2" <br /> <br />M <br />I <br />N <br />. <br />CLOSET INSTALLATION (OUTDOOR) <br />28" MIN. <br />INSTALLATIONS THAT REQUIRE LESS THAN 7” <br />CLEARANCE ON THE RIGHT SIDE OR REAR OF <br />THE WATER HEATER FOR EARTHQUAKE STRAPS <br />ARE ALSO ACCEPTABLE. IN THESE CASES, IT IS <br />RECOMMENDED TO PROVIDE ADDITIONAL <br />CLEARANCE ON THE OPPOSITE SIDE OF THE <br />UNIT TO ALLOW FOR SERVICE ACCESS. <br />±2 <br />5 <br />" <br />6" <br />LOUVER DOOR <br />WITH 240 IN² OF OPEN AIRFLOW AREA <br />STRAPPING SEE DETAIL 1 A-5.2. <br />STRAPPING SEE <br />DETAIL 1 A-5.2. <br />DETAIL <br />INTERIOR GYP. BOARD <br />BATT INSULATION <br />WOOD FRAMING <br />3 1 <br />2" MINIMUM <br />ATTACHMENT FLANGE <br />MORTAR SETTING BED <br />MORTAL JOINT <br />#26 G.I. SHEET WEEP SCREED <br />NOTE: WEEP SCREED NEEDS TO BE <br />INSTALLED 1" BELOW THE SILL PLATE. <br />2% SLOPE <br />4" (MIN.) = UNPAVED SURFACE <br />2" (MIN.) = PAVED SURFACE <br />STONE VENEER OVER WOOD FRAMING <br />CONCRETE SLAB / FOOTING <br />WEATHER RESISTIVE BARRIER REQUIRED <br />TO LAP THE WEEP SCREED ATTACHMENT <br />FLANGE <br />2" THICK (MAX) ADHERED STONE VENEER <br />MORTAR SCRATCH COAT <br />EXTERIOR SHEATHING <br />(2) LAYERS OF WRB <br />LATH FASTENERS - TYPE & <br />SPACING PER ASTM C1063 V E C O <br />d e s i g n - s t u d i o <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />SANCHEZ <br />RESIDENCE <br />23-022 <br />10-17-2024 <br />N.P. <br />714-474-3531 <br />1142 & 1144 S CLARA ST. <br />1142 UNIT 2, S CLARA ST. <br />SANTA ANA CA 92704 <br />d e s i g n e r <br />O s c a r V e g a <br />C e - -2 <br />O i e - 2 -5 <br />i n o e o d e s i g n s .o <br />5 C O A V E . <br />A A E C A 2 5 <br />APPROVED BY :O.V. <br />A-5.2 <br />ARCHITECTURAL <br />DETAILS
The URL can be used to link to this page
Your browser does not support the video tag.