My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1144 S Clara St & 1142 S Clara St & #2 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Clara St
>
1142 S Clara St Unit# 2
>
1144 S Clara St & 1142 S Clara St & #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:11 AM
Creation date
2/13/2026 5:01:19 AM
Metadata
Fields
Template:
Plan
Permit Number
101119966
Full Address
1142 S Clara St Unit# 2
Street Number
1142
Street Direction
S
Street Name
Clara
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NEW BATH <br />CEILING HT.= 8'-0" <br />DOORWAY WITH A NET <br />CLEAR OPENING OF <br />NOT LESS THAN 32", <br />MEASURED WITH THE <br />DOOR POSITIONED AT <br />AN ANGLE OF 90 <br />DEGREES FROM THE <br />CLOSED POSITION <br />32 <br /> <br />M <br />I <br />N <br />. <br />30" <br />MIN. <br />15" <br />MIN. <br />15" <br />MIN. <br />3'-0" <br />2' <br />- <br />0 <br />" <br />22 <br />" <br /> <br />M <br />I <br />N <br />. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />TEMP. <br />GLASS <br />GRAB BAR <br />REINFORCEMENT <br />AREA. <br />SEE AGING-IN PLACE <br />REQUIREMENTS <br />DETAIL IN SHEET G-3 <br />CONTROL VALVES AND SHOWER <br />HEADS SHALL BE LOCATED ON THE <br />SIDEWALL OF SHOWER <br />COMPARTMENT OR OTHERWISE <br />ARRANGED SO THAT THE <br />SHOWERHEAD DOES NOT <br />DISCHARGE DIRECTLY AT THE <br />ENTRANCE TO THE COMPARTMENT <br />AND THE BATHER CAN ADJUST THE <br />VALVES PRIOR TO STEPPING INTO <br />THE SHOWER SPRAY (CPC 408.9). <br />SHOWER STALL TO BE 1024 <br />SQUARE INCHES MINIMUM AND <br />CAPABLE OF ENCOMPASSING <br />A 30" DIAMETER CIRCLE. <br />SHOWER VALVE CONTROL SHOWER "UNOBSTRUCTED" <br />OPENING (DOOR) SHALL <br />BE 22" MIN. GLASS DOOR <br />MUST BE TEMP. GLASS <br />ENLARGED BATHROOM 1 <br />SCALE: 3/8" = 1'-0"4 <br />ADDITIONAL NOTES: <br />·WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED <br />EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERS OR TUB WITH <br />SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO <br />BE MOISTURE RESISTANT. (CRC R307.2). <br />·LOCATION SMOKE DETECTORS (CRC R314): <br />- A MINIMUM OF 3 FT. FROM BATHROOM. <br />- SMOKE DETECTORS SHALL BE LISTED FOR CLOSE PROXIMITY TO <br />COOKING APPLIANCES WHEN LOCATED LESS THAN 6' FROM SAID <br />APPLIANCE. <br />SHOWER HEAD <br />EF <br />NEW BEDROOM 1 NEW BEDROOM 2 <br />NEW FRONT <br />PORCH <br />NEW LIVING AREA <br />NEW <br />BATH <br />A.WALK-IN CLOSET WITH AN AREA GREATER THAN 70 FT² WILL BE PROVIDED WITH <br />DIMMER SWITCHES FOR LIGHTING [CRnC 150.0(k)J]. <br />B.OUTDOOR LUMINARIES SHALL BE CONTROLLED BY PHOTOCELL AND MOTION <br />SENSOR, OR OTHER METHOD AS PERMITTED BY [CEnC 150.0(k)3A]. <br />C.CEILING RECESSED LED DOWNLIGHTS SHALL BE REQUIRED TO BE APPENDIX JA8 <br />COMPLIANT [CEnC 150.0(k)1]. <br />D.ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING <br />OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, LIVING ROOMS, <br />BEDROOMS, CLOSETS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE <br />AFCI PROTECTED BY ANY OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6). <br />E.IN EACH ATTACHED GARAGE WITH ELECTRIC POWER, AT LEAST ONE RECEPTACLE <br />OUTLET SHALL BE INSTALLED IN EACH VEHICLE BAY AND NOT MORE THAN 1.7 M (5 <br />½ FT.) ABOVE THE FLOOR. CEC 210.52 (G) (1) <br />F.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE <br />USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48” MEASURED FROM <br />THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />G.DOORBELL CONTROLS TO NOT EXCEED 48” ABOVE EXTERIOR FLOOR, MEASURED <br />FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. <br />H.ALL LIGHTING TO BE HIGH EFFICACY. CENERGYC 150.0(K)1(A). <br />I.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY AN OCCUPANCY <br />OR VACANCY SENSOR. CENC §150.0(K)2I. <br />J.LUMINAIRES THAT ARE OR CONTAIN LIGHT SOURCES THAT MEET REFERENCE JOINT <br />APPENDIX JA8 REQUIREMENTS FOR DIMMING, AND THAT ARE NOT CONTROLLED BY <br />OCCUPANCY OR VACANCY SENSORS MUST HAVE DIMMING CONTROLS EXCEPT IN <br />CLOSETS LESS THAN 70 SQUARE FEET OR HALLWAYS. CENC §150.0(K)2J. <br />K.FOR SINGLE-FAMILY RESIDENTIAL BUILDINGS, OUTDOOR LIGHTING PERMANENTLY <br />MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT <br />MUST MEET THE REQUIREMENT IN ITEM A AND THE REQUIREMENTS IN ITEM A AND <br />THE REQUIREMENTS IN EITHER ITEM B OR ITEM C: <br />1.CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT PERMITS THE <br />AUTOMATIC ACTIONS OF ITEMS B OR C BELOW; AND <br />2.CONTROLLED BY PHOTOCELL AND EITHER A MOTION SENSOR OR AN AUTOMATIC <br />TIME SWITCH; OR <br />3.CONTROLLED BY AN ASTRONOMICAL TIME CLOCK CONTROL. CENC §150.0(K)3A. <br />L.IN ADDITION TO THE LOCAL EXHAUST FANS IN THE BATHROOMS AND KITCHENS, AN <br />EXHAUST FAN SHALL BE SIZED TO PROVIDE VENTILATION FOR THE WHOLE HOUSE. <br />THE MINIMUM VENTILATION RATE FOR THE IAQ FAN SHALL BE CALCULATED <br />ACCORDING TO ASHRAE STANDARD 62.2 AND 150.0(o)C / 160.2. ONE OF THE <br />LOCAL EXHAUST FAN IN THE BATHROOMS OF KITCHENS MAY BE USED TO MEET THE <br />WHOLE-BUILDING VENTILATION, PROVIDED THE EXHAUST FAN MEETS THE MINIMUM <br />VENTILATION RATED FOR BOTH THE LOCAL EXHAUST AND IAQ REQUIREMENTS. THE <br />DUCTING FOR THE WHOLE BUILDING EXHAUST FAN SHALL BE SIZED ACCORDING TO <br />TABLE 150.0-H / 160.2-H, AND THIS EXHAUST FAN SHALL OPERATE CONTINUOUSLY. <br />ELECTRICAL LEGEND <br />ELECTRICAL & MECHANICAL NOTES:TABLE 150.0-G <br />KITCHEN RANGE HOOD AIRFLOW RATES (CFM) AND ASTM E3087 <br />CAPTURE EFFICIENCY (CE) RATINGS ACCORDING TO DWELLING <br />UNIT FLOOR AREA AND KITCHEN RANGE FUEL TYPE <br />DWELLING UNIT FLOOR AREA (FT²)HOOD OVER ELECTRIC RANGE <br />> 1500 50% CE or 110 CFM <br />> 1000 - 1500 50% CE or 110 CFM <br />750 - 1000 50% CE or 130 CFM <br />> 750 50% CE or 160 CFM <br />ASHRAE STANDARD 62.2 TABLE 7.1 <br />PRESCRIPTIVE DUCT SIZING REQUIREMENTS <br />DUCT TYPE FLEX DUCT SMOOTH DUCT <br />FAN RATING CFM <br />@0.25 IN. W.G.50 80 100 125 50 80 100 125 <br />MAXIMUM ALLOWABLE DUCT LENGTH (FT) <br />DIAMETER (IN)FLEX DUCT SMOOTH DUCT <br />3 X X X X 5 X X X <br />4 70 3 X X 105 35 5 X <br />5 NL 70 35 20 NL 135 85 55 <br />6 NL NL 125 95 NL NL NL 145 <br />7 AND ABOVE NL NL NL NL NL NL NL NL <br />THIS TABLE ASSUMES NO ELBOWS. DEDUCT 15 FT. OF ALLOWABLE DUCT LENGHT FOR EACH <br />TURN, ELBOW, OR FITTING. <br />NL= NO LIMIT ON DUCT LENGTH OF THIS SIZE <br />X= NOT ALLOWED, ANY LENGTH OF DUCT OF THIS SIZE WITH ASSUMED TURNS, ELBOWS, <br />FITTINGS WILL EXCEED THE RATED PRESSURE DROP. <br />NEW DUPLEX RECEPTACLE WITH GFCI PROTECTION <br />NEW SWITCH <br />"UL LISTED " NEW LED RECESSED LIGHT (HIGH-EFFICACY) <br />NEW LED PENDANT LIGHT (HIGH-EFFICACY) <br />NEW SWITCH W/ OCCUPANCY SENSOR <br />NEW AFCI DUPLEX RECEPTACLE OUTLET <br />NEW SWITCH 3 WAY <br />NEW EXTERIOR WATER PROOF OUTLET <br />OS <br />GFCI <br />AFCI <br />3 <br />WP <br />S <br />S <br />S <br />NEW LED WALL MOUNT LIGHT WITH PHOTOCELL SENSOR (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS. <br />NEW SWITCH W/DIMMER COMPLY WITH NEMA SSL 7A. (CAL. ENERGY <br />CODE SECTION 150.0 (K) 2F)D <br />NEW LED WALL MOUNT LIGHT <br />(HIGH-EFFICACY) <br />NEW SWITCH W/ MOTION SENSORMS <br />S <br />PS <br />NEW LED WALL MOUNT LIGHT WITH MOTION SENSOR (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS. <br />S <br />MS <br />NOTE:RECESSED LUMINARIES SHALL FIXTURES BE LISTED <br />FOR ZERO CLEARANCE INSULATION CONTACT (IC) <br />NEW LED RECESSED LIGHT (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS <br />DUCTLESS MINI-SPLIT AIR CONDITIONER INDOOR UNIT WALL MOUNTED <br />CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68° F <br />SEE ADDITIONAL SPECIFICATION IN TITLE REPORT <br />SYMBOL LEGEND <br />WHOLE-BUILDING IAQ VENTILATION EXHAUST FAN THAT WILL OPERATE <br />CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A <br />MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY A <br />STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED <br />CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT: "THIS <br />SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE <br />HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE <br />OUTDOOR AIR QUALITY IS VERY POOR." [150.0(O)J]. <br />CFM SHALL BE : 80 (PER ENERGY REPORT) <br />SCALE: 1/4" = 1'-0" <br />1 1ST. FLOOR ELECTRICAL PLAN <br />SCALE: 1/4" = 1'-0" <br />2 2ND. FLOOR ELECTRICAL PLAN <br />SD <br />CM <br />SD SD <br />SD CM <br />22"x30" <br />ATTIC <br />ACCESS <br />EF <br />RH <br />PS <br />EF <br />DUAL ZONE MINI-SPLIT <br />OUTDOOR CONDENSER UNITWP <br />WP <br />3S <br />S <br />S3 3S 3S <br />S S <br />S <br />OS <br />S <br />S <br />S <br />3SS <br />OS <br />S <br />S <br />S <br />3S <br />3S <br />3S <br />D D <br />DD <br />AFCI <br />AFCI <br />AFCI AFCI <br />GFCI GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />AFCI AFCI AFCI AFCI <br />AFCI AFCI <br />AFCI <br />AFCI <br />AFCI <br />GFCI <br />LI <br />N <br />E <br /> <br />O <br />F <br /> <br />2 <br />N <br />D <br />. <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />A <br />B <br />O <br />V <br />E <br />A TYPE 1 CLOTHES DRYER EXHAUST DUCT (MIN. 4" DIA. & <br />0.016" THICK RIGID METAL) TO THE OUTSIDE OF THE <br />BUILDING AND EQUIPPED WITH A BACK-DRAFT DAMPER <br />SHALL BE PROVIDED. EXHAUST DUCT LENGTH IS LIMITED <br />TO 14'. WITH 2 ELBOWS <br />NOTE: EXHAUST DUCT FOR DRYER MUST BE TERMINATED <br />NOT LESS THAN 3 FEET FROM OPERABLE WINDOW/DOOR <br />OPENINGS. (CMC 502.2.1) <br />PROVIDE A DEDICATED 125 VOLT, 20 AMP <br />ELECTRICAL GFCI RECEPTACLE CONNECTED TO <br />THE ELECTRICAL PANEL WITH A 120/240 VOLT 3 <br />CONDUCTOR 10 AWG COPPER BRANCH CIRCUIT, <br />WITHIN 3 FT OF THE WATER HEATER AND <br />ACCESSIBLE TO THE WATER HEATER <br />NEW BATH <br />CEILING HT.= 8'-0" <br />DOORWAY WITH A NET <br />CLEAR OPENING OF <br />NOT LESS THAN 32", <br />MEASURED WITH THE <br />DOOR POSITIONED AT <br />AN ANGLE OF 90 <br />DEGREES FROM THE <br />CLOSED POSITION <br />32 <br /> <br />M <br />I <br />N <br />. <br />30" <br />MIN. <br />15" <br />MIN. <br />15" <br />MIN. <br />3'-0" <br />2' <br />- <br />0 <br />" <br />22 <br />" <br /> <br />M <br />I <br />N <br />. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />TEMP. <br />GLASS <br />GRAB BAR <br />REINFORCEMENT <br />AREA. <br />SEE AGING-IN PLACE <br />REQUIREMENTS <br />DETAIL IN SHEET G-3 <br />CONTROL VALVES AND SHOWER <br />HEADS SHALL BE LOCATED ON THE <br />SIDEWALL OF SHOWER <br />COMPARTMENT OR OTHERWISE <br />ARRANGED SO THAT THE <br />SHOWERHEAD DOES NOT <br />DISCHARGE DIRECTLY AT THE <br />ENTRANCE TO THE COMPARTMENT <br />AND THE BATHER CAN ADJUST THE <br />VALVES PRIOR TO STEPPING INTO <br />THE SHOWER SPRAY (CPC 408.9). <br />SHOWER STALL TO BE 1024 <br />SQUARE INCHES MINIMUM AND <br />CAPABLE OF ENCOMPASSING <br />A 30" DIAMETER CIRCLE. <br />SHOWER VALVE CONTROL SHOWER "UNOBSTRUCTED" <br />OPENING (DOOR) SHALL <br />BE 22" MIN. GLASS DOOR <br />MUST BE TEMP. GLASS <br />ENLARGED BATHROOM 1 <br />SCALE: 3/8" = 1'-0"4 <br />ADDITIONAL NOTES: <br />·WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED <br />EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERS OR TUB WITH <br />SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO <br />BE MOISTURE RESISTANT. (CRC R307.2). <br />·LOCATION SMOKE DETECTORS (CRC R314): <br />- A MINIMUM OF 3 FT. FROM BATHROOM. <br />- SMOKE DETECTORS SHALL BE LISTED FOR CLOSE PROXIMITY TO <br />COOKING APPLIANCES WHEN LOCATED LESS THAN 6' FROM SAID <br />APPLIANCE. <br />NOTE: NO GAS HOOK <br />UP AT STOVE <br />WASHER <br />& DRYER <br />POWDER <br />RM. <br />31 Sq. Ft. <br />ENLARGED BATHROOM 2 <br />SCALE: 3/8" = 1'-0"3 <br />ADDITIONAL NOTES: <br />·WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED <br />EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERS OR TUB WITH <br />SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO <br />BE MOISTURE RESISTANT. (CRC R307.2). <br />·LOCATION SMOKE DETECTORS (CRC R314): <br />- A MINIMUM OF 3 FT. FROM BATHROOM. <br />- SMOKE DETECTORS SHALL BE LISTED FOR CLOSE PROXIMITY TO <br />COOKING APPLIANCES WHEN LOCATED LESS THAN 6' FROM SAID <br />APPLIANCE. <br />15" <br />MIN. <br />15" <br />MIN. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />DOORWAY WITH A NET CLEAR <br />OPENING OF NOT LESS THAN 32", <br />MEASURED WITH THE DOOR <br />POSITIONED AT AN ANGLE OF 90 <br />DEGREES FROM THE CLOSED POSITION <br />32 <br /> <br />M <br />I <br />N <br />. <br />3'-0" <br />2' <br />- <br />0 <br />" <br />GENERAL CONTRACTOR <br />SHALL PROVIDE <br />HOOKUPS FOR <br />WASHER AND DRYER <br />SHOWER HEAD <br />NE <br />W <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />NE <br />W <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />POWDER <br />RM. <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />S <br />EF <br />EF <br />EF <br />EXHAUST DUCT TERMINATION. <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM <br />PROPERTY LINE AND 3’-0” FROM OPENINGS <br />INTO THE BUILDING. CMC 504.5 <br />EF <br />NEW WATER HEATER HEAT PUMP <br />40 GAL, BRAND: RHEEM W/ SEISMIC STRAPPING <br />·STRAPPING SHALL BE AT POINTS WITHIN <br />THE UPPER ONE THIRD AND LOWER <br />ONE-THIRD OF THE W/H. <br />·AT THE LOWER POINT, A MINIMUM DISTANCE <br />OF FOUR INCHES SHALL BE MAINTAINED <br />ABOVE THE CONTROLS WITH THE STRAPPING <br /> NOTE: LOCATION PER GENERAL CONTRACTOR <br />·LIGHTING IN HABITABLE SPACES, INCLUDING BUT NO LIMITED TO LIVING ROOMS, DINING ROOMS, <br />KITCHENS AND BEDROOMS, SHALL HAVE READILY ACCESSIBLE WALL-MOUNTED DIMMING CONTROLS <br />THAT ALLOW THE LIGHTING TO BE MANUALLY ADJUSTED UP AND DOWN. FORWARD PHASE CUT <br />DIMMERS CONTROLLING LED LIGHT SOURCES IN THESE SPACES SHALL COMPLY WITH NEMA SSL 7A. <br />(CAL. ENERGY CODE SECTION 150.0(K)2F). <br />·FOR NEW CONSTRUCTION, PROVIDE ENERGY STORAGE SYSTEM READY SHALL MEET THE FOLLOWING: <br />(CEnC SECTION 150.0(s)): <br />A)AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br /> 1) ESS-READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED UP CAPACITY OF 60 AMPS <br /> AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS. <br /> 2) A DEDICATED RACEWAY FROM MAIN SERVICE TO SUB PANEL THAT SUPPLIES BRANCH CIRCUITS. <br />B)FOUR OR MORE BRANCH CIRCUITS FROM A SINGLE PANEL BOARD SUITABLE TO BE SUPPLIED BY THE <br />ESS: AT LEAST ONE CIRCUIT MUST SUPPLY THE REFRIGERATOR, LIGHTING CIRCUIT NEAR THE PRIMARY <br />EGRESS, AND A SLEEPING ROOM RECEPTACLE OUTLET. <br />C)A MAIN PANEL BOARD WITH A MINIMUM BUS BAR RATING OF 225 AMPS. <br />D)SUFFICIENT SPACE RESERVED TO ALLOW FUTURE INSTALLATION OF SYSTEM ISOLATION EQUIPMENT <br />OR A TRANSFER SWITCH WITHIN 3 FT. OF THE MAIN PANEL BOARD. <br />ADDITIONAL NOTES: <br />NEW 100 AMPS ELECTRICAL <br />PANEL FOR PROPOSED ADU <br />WITH TYPE 1 SURGE PROTECTIVE <br />DEVISE (SPD) WITH MAIN <br />BREAKER DISCONNECT. <br />NOTE: FINAL LOCATION PER <br />EDISION <br />D <br />D <br />DD <br />NEW KITCHEN <br />ELECTRIC <br />STOVE <br />N <br />EXHAUST DUCT TERMINATION <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM <br />PROPERTY LINE AND 3’-0” FROM OPENINGS <br />INTO THE BUILDING. CMC 504.5 <br />DUCTING FOR EXHAUST FAN SHALL BE SIZED <br />ACCORDING TO ASHRAE STANDARD 62.2 <br />TABLE 7.1 <br />EXHAUST DUCT TERMINATION. <br />AIR DUCTS SHALL EXHAUST <br />3’-0” FROM PROPERTY LINE <br />AND 3’-0” FROM OPENINGS <br />INTO THE BUILDING. CMC <br />504.5 <br />WASHER <br />& DRYER <br />POWDER <br />RM. <br />31 Sq. Ft. <br />ENLARGED BATHROOM 2 <br />SCALE: 3/8" = 1'-0"3 <br />ADDITIONAL NOTES: <br />·WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED <br />EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERS OR TUB WITH <br />SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO <br />BE MOISTURE RESISTANT. (CRC R307.2). <br />·LOCATION SMOKE DETECTORS (CRC R314): <br />- A MINIMUM OF 3 FT. FROM BATHROOM. <br />- SMOKE DETECTORS SHALL BE LISTED FOR CLOSE PROXIMITY TO <br />COOKING APPLIANCES WHEN LOCATED LESS THAN 6' FROM SAID <br />APPLIANCE. <br />15" <br />MIN. <br />15" <br />MIN. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />DOORWAY WITH A NET CLEAR <br />OPENING OF NOT LESS THAN 32", <br />MEASURED WITH THE DOOR <br />POSITIONED AT AN ANGLE OF 90 <br />DEGREES FROM THE CLOSED POSITION <br />32 <br /> <br />M <br />I <br />N <br />. <br />3'-0" <br />2' <br />- <br />0 <br />" <br />GENERAL CONTRACTOR <br />SHALL PROVIDE <br />HOOKUPS FOR <br />WASHER AND DRYER <br />EF <br />EF <br />V E C O <br />d e s i g n - s t u d i o <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />SANCHEZ <br />RESIDENCE <br />23-022 <br />10-17-2024 <br />N.P. <br />714-474-3531 <br />1142 & 1144 S CLARA ST. <br />1142 UNIT 2, S CLARA ST. <br />SANTA ANA CA 92704 <br />d e s i g n e r <br />O s c a r V e g a <br />C e - -2 <br />O i e - 2 - <br />i n o e o d e s i g n s .o <br /> C O A V E . <br />A A E C A 2 <br />APPROVED BY :O.V. <br />A-2.2 <br />ELECTRICAL <br />PLAN A.D.U.
The URL can be used to link to this page
Your browser does not support the video tag.