My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1112 W 6th St & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sixth St
>
1112 W Sixth St Unit# 2
>
1112 W 6th St & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:10 AM
Creation date
2/13/2026 5:01:22 AM
Metadata
Fields
Template:
Plan
Permit Number
101120611
Full Address
1112 W Sixth St Unit# 2
Street Number
1112
Street Direction
W
Street Name
Sixth
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />Plan gijy�aWc wi 1png Agency <br />anta Ana CA 92703 <br />Drainage Approved <br />According to CBC 2022, Chapter 18, 1804.4, Site Grading, the ground immediate) aR9c1Pt4fIJ ISSUANCE <br />foundation shall be sloped away from the building at a slope of not less than one ur it vertical in 20 <br />units horizontal (5 percent slope) for a minimum distance of 10 feet measured peril icula tto the <br />face of the wall. If physical obstructions of lot lines prohibit 10 ft of horizontal dis cst a Spercent <br />slope shall be provided at an approved alternative method of diverting water away roam the <br />foundation. Swales used for this purpose shall be sloped a minimum of 2 percent, Vithin tO feet of the <br />building foundation. Impervious surfaces within 10 feet of the building foundation shall be sloped a <br />minimum of 2 percent away from the building. <br />Concrete Slab Construction <br />Footing Design <br />Exterior and interior footings for a single story structure should be founded 16 inches below the lowest <br />adjacent grade with a minimum width of 12 inches. <br />Two story structures shall have footings 24 inches below the lowest adjacent grade with a minimum <br />width of 15 inches. Reinforcement should consist of four #4 reinforcing bars placed two at the top and <br />two at the bottom of the footing. These reinforcing bars shall be positioned with minimum cover of 2 <br />inches at the center of all continuous footings, properly lapped and tied. Footings must be strengthened <br />for the remodel. <br />Foundation <br />Over excavate all building areas three feet and three feet beyond foundation dimension, or to compe- <br />tent insitu soils as determined by field test during excavation, whichever is deeper. Scarify exposed <br />subgrade 8 inches and moisturize to optimum moisture content. Compact to minimum 90% density <br />and replace soil in 8 inch lifts, moisturize and compact to minimum 90% of maximum density. <br />Paved Areas- General <br />Paved areas consist of concrete patios, sidewalks and driveways. There are different requirements for <br />the preparation of each of these areas. <br />Concrete patios are generally adjacent to the building itself. Proper preparation of the area for con- <br />crete patios is extremely important. Improper compaction or preparation will permit cracks and settle- <br />ment of the paving that are not acceptable. It is required that all areas for concrete patios be excavated <br />12 inches and recompacted to the proper density as described above. <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.