Laserfiche WebLink
1'-7"8'-6"1'-3"36'-2" <br />3' <br />- <br />6 <br />" <br />5'-6" <br />3' <br />- <br />2 <br />" <br />2' <br />- <br />4 <br />" <br />3'-0" <br />2'-4" <br />4' <br />- <br />0 <br />" <br />2'-4" <br />3' <br />- <br />4 <br />" <br />4" <br />5' <br />- <br />8 <br />" <br />1' <br />- <br />4 <br />" <br />5' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />2" <br />B <br />A <br />O <br /> <br /> <br />P <br />H <br />A <br />M <br /> <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br /> <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />LICENSED ARCHITECT <br />STATEOF C ALIFORNIA <br />C-39025 <br />REN. 08/31/25 <br />BAO PHAM <br />ARCHITECT OF RECORD: <br />BAO PHAM, RA <br />1310 <br />N H <br />AR <br />B <br />OR <br /> <br />B <br />LVD <br />. <br /> <br />SA <br />N <br />TA A <br />N <br />A C <br />A <br />9 <br />2 <br />7 <br />0 <br />3 <br /> <br />| b <br />a <br />o@b <br />pdo-ar <br />c <br />hi <br />tect <br />s <br />. <br />c <br />om <br /> | <br /> <br /> <br />7 <br />1 <br />4 <br />. <br />457.0436 <br />SF <br />R <br /> <br />RE <br />M <br />O <br />D <br />E <br />L <br />/ <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br />1 <br />ISSUANCE <br />Designed plans and specifications <br />represented by these drawings are <br />properties of BPDO and were <br />developed for use in connection with <br />each particular project. None of these <br />plans and ideas shall be used, <br />duplicated, disclosed, in part or in <br />whole, without written permission of <br />BPDO. <br />10 <br />2 <br />5 <br /> <br />W <br /> <br />C <br />A <br />R <br />L <br />T <br />O <br />N <br /> <br />P <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />2024.06.25 PLANNING SUBMITTAL <br />2024.08.06 CYCLE 1 SUBMITTAL <br />DEMOLITION PLAN <br />D1.1 <br />1.VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. BRING ANY <br />DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE ARCHITECT <br />IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK <br />SHALL NOT JUSTIFY AN ADDITIONAL COST. <br />2.REMOVAL OF EXISTING FIXTURES AND EQUIPMENT WILL REQUIRE <br />ISOLATING THE PIPING RISERS OR MAINS VIA SHUT-OFF VALVES. INSTALL <br />NEW ISOLATION VALVES WHERE REQUIRED FOR COMPLETION OF WORK. <br />3.REMOVAL OF EXISTING PLUMBING FIXTURES AND EQUIPMENT, ETC. WILL <br />REQUIRE CAPPING AND SEALING EXISTING MAINS OR BRANCHES AS <br />NECESSARY AND REQUIRED TO ALLOW THE REMAINING SYSTEMS TO FULLY <br />OPERATE WITHOUT DEGRADATION. CONTRACTOR SHALL PROVIDE <br />PROTECTIVE PLASTIC DROP CLOTHS TO PROTECT THE EXISTING OCCUPIED <br />AREAS AND EQUIPMENT FROM DUST AND DEBRIS DURING THE <br />CONSTRUCTION WORK, AND SHALL CLEAN THE AREAS OF ALL <br />CONSTRUCTION DIRT DAILY, AND UPON COMPLETION OF THE WORK. REFER <br />TO GENERAL CONDITIONS AND DIVISION 1 SECTIONS IN THE <br />SPECIFICATIONS. <br />4.ALL DRAINED PIPING RISERS AND MAINS SHALL BE REFILLED WITH PROPER <br />FLUID AND PROPERLY VENTED BY THIS CONTRACTOR, ONCE NEW WORK <br />HAS BEEN INSTALLED. <br />5.COORDINATE WITH GENERAL CONTRACTOR THE REMOVAL AND <br />REPLACEMENT OF ALL EXISTING CEILINGS, WALLS, ETC. AS REQUIRED FOR <br />MECHANICAL DEMOLITION WORK. <br />6.EXISTING PIPING AND EQUIPMENT, ETC., NOT TO BE UTILIZED IN THE <br />COMPLETED BUILDING SHALL BE DISCONTINUED OR REMOVED AS <br />REQUIRED. ALL ENDS OF DISCONTINUED PIPING SHALL BE CAPPED IN THE <br />NEAREST WALL, CEILING OR FLOOR SO THAT THEY ARE COMPLETELY <br />CONCEALED. OPENINGS LEFT IN WALLS, CEILINGS, ETC., WHERE <br />EQUIPMENT AND PIPE, ETC., ARE REMOVED AND NOT REPLACED, SHALL BE <br />PATCHED NEATLY WITH SIMILAR MATERIAL TO ADJACENT CONSTRUCTION. <br />REFER TO DRAWINGS DELINEATING NEW WORK FOR ADDITIONAL <br />INFORMATION REGARDING SYSTEMS OR PORTIONS OF SYSTEMS WHERE <br />USE IS TO BE DISCONTINUED. <br />7.EXISTING PIPING, FIXTURES AND EQUIPMENT THAT ARE NOT TO BE REUSED <br />SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE OWNER IF <br />THEY WISH TO RETAIN OWNERSHIP OF SAME. IF NOT, EQUIPMENT SHALL <br />BECOME THE PROPERTY OF THIS CONTRACTOR AND SHALL BE REMOVED <br />FROM THE SITE AS SOON AS PRACTICAL AND DISPOSED OF IN ACCORDANCE <br />WITH APPLICABLE LAWS AND REGULATIONS. <br />8.ALL CUTTING AND CHANNELING OF EXISTING BUILDING SHALL BE <br />ACCOMPLISHED IN A NEAT AND WORKMANLIKE MANNER WITHOUT REMOVAL <br />OF EXCESS MATERIALS. THIS CONTRACTOR SHALL PATCH AND REPLACE <br />WITH MATERIAL SIMILAR TO ADJACENT CONSTRUCTION. <br />9.WHERE EXISTING PIPING AND EQUIPMENT, ETC., THAT ARE TO BE UTILIZED <br />IN THE COMPLETED PROGRAM CONFLICT WITH NEW CONSTRUCTION AND <br />THE REQUIRED DEMOLITION, THEY SHALL BE RELOCATED AND <br />RECONNECTED TO MAINTAIN THE DESIRED SERVICE. <br />10.PORTIONS OF EXISTING SYSTEMS MAY BE SHOWN FOR CLARITY EVEN <br />THOUGH IT MAY NOT BE NECESSARY TO MODIFY OR REVISE THEM. ALL <br />EXISTING SYSTEMS ARE SHOWN BASED ON ORIGINAL OR REMODEL <br />BUILDING DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS. <br />11.ALL WORK MUST BE COORDINATED AND SCHEDULED WITH THE OWNER AND <br />OCCUPANTS OF THIS BUILDING SO AS TO PROVIDE THE LEAST AMOUNT OF <br />DISRUPTION OF BUILDING ACTIVITIES AS POSSIBLE. <br />12.ALL ACCESSIBLE ABANDONED PIPING AND DUCTWORK SHALL BE REMOVED <br />AND PROPERLY DISPOSED OF. <br />GENERAL NOTES <br />WALL LEGEND <br />EXTERIOR WALL <br />2X4 WALL STUDS @ 16" O.C | SIDING EXTERIOR <br />1/2" GWB INTERIOR <br />EXISTING WALL <br />2X4 WALL STUDS @ 16" O.C | 1/2" GWB INTERIOR <br />8 <br />A3.0 <br />1,9 <br />A3.0 <br />INTERIOR WALL <br />2X4 WALL STUDS @ 16" O.C | 1/2" GWB INTERIOR <br />PLUMBING WALL <br />2X WALL STUDS @ 16" O.C | 1/2" GWB INTERIOR 4 <br />A3.1 <br />8 <br />A3.0 <br />1 HR RATED EXTERIOR WALL <br />W/ 5/8" TYPE X GWB ON INTERIOR SIDE. EXTERIOR FINISH PER <br />ELEVATION | UL 309 <br />4,12 <br />A3.0 <br />1 <br />SCALE:10 EXISTING & DEMOLITION PLAN <br />1/4" = 1'-0" <br />REMOVE EXISTING SIDING AND WOOD STUD. PATCH AND REPAIR AS <br />NEEDED. PREPARE FOR NEW CONSTRUCTION. <br />REMOVE EXISTING WINDOW AND FRAME FROM EXTERIOR WALL TO <br />ACCOMMODATE NEW VINYL REPLACEMENT WINDOW INSTALLATION. <br />EXISTING JAMBS ARE TO BE RE-USED AND NEW WOOD HEADS AND JAMB <br />ARE TO BE FURNISHED AND INSTALLED. FIELD VERIFY WINDOW OPENING <br />BEFORE PROCURING NEW REPLACEMENT WINDOWS. PATCH AND REPAIR <br />AS NEEDED. <br />1 <br />2 <br />REMOVE EXISTING WOOD FLOOR AND ANY FLOOR FINISH AS REQUIRED <br />TO ACCOMMODATE NEW CONSTRUCTION <br />4 <br />DISCONNECT EXISTING PLUMBING FIXTURES AND CAP AS REQUIRED TO <br />ACCOMMODATE NEW CONSTRUCTION <br />KEY NOTES <br />5 <br />DISCONNECT EXISTING GAS WATER HEATER AND CAP AS REQUIRED TO <br />ACCOMMODATE NEW CONSTRUCTION <br />6 <br />DISCONNECT EXISTING WALL HEATER AND CAP AS REQUIRED TO <br />ACCOMMODATE NEW CONSTRUCTION <br />7 <br />DISCONNECT EXISTING CONDENSER UNIT AND CAP AS REQUIRED TO <br />ACCOMMODATE NEW CONSTRUCTION <br />REMOVE EXISTING CONCRETE LANDING. PATCH AND REPAIR AS NEEDED. <br />PREP FOR NEW CONSTRUCTION. <br />8 <br />REMOVE EXISTING INTERIOR WOOD STUD WALL. PATCH AND REPAIR AS <br />NEEDED. PREPARE FOR NEW CONSTRUCTION. <br />3 <br />9 <br />REMOVE EXISTING DOOR AND FRAME FROM EXTERIOR WALL TO <br />ACCOMMODATE NEW CONSTRUCTION. PATCH AND REPAIR AS NEEDED. <br />10 <br />11 <br />REMOVE EXISTING KITCHEN AND ASSOCIATED CABINETS AND FIXTURES. <br />PATCH AND REPAIR AS NEEDED. PREP FOR NEW CONSTRUCTION. <br />3 <br />4A <br />2 <br />SCALE:20 DEMOLITION & PROPOSED OVERLAY <br />1/4" = 1'-0" <br />PROPOSED WALL <br />WALLS TO BE DEMOLISH <br />EXISTING WALL TO REMAIN <br />4A REMOVE EXISTING WINDOW AND FRAME FROM EXTERIOR WALL - PATCH <br />AND REPAIR AS NEEDED. <br />PROPOSED WALL <br />WALLS TO BE DEMOLISH <br />EXISTING WALL TO REMAIN <br />EXISTING CEILING BEAM TO REMAIN12 <br />3 <br />3 3 <br />1 1 <br />22 <br />4A4A4A4A <br />4A <br />2 <br />55 <br />7 <br />8 <br />9 <br />3 <br />11 <br />10 <br />GC NOTE: CONFIRM ALL ON SITE DIMENSION PRIOR TO <br />DEMOLITION