Laserfiche WebLink
GENE <br />These plans are intended for use by only knowledgeable licensed contractors familiar with <br />all applicable building codes and other governmental requirements, and able and willing to <br />provide workmanship and materials of high quality. They shall be interpreted so as to <br />incorporate all applicable building codes and other governmental requirements. All ambiguities <br />and doubts shall be resolved, unless the Engineer Of Record specifies otherwise in writing, in <br />favor of the construction or material of the highest quality. <br />Written information and dimensions shall take precedence over graphic information. <br />Do not scale drawings. <br />All dimensions are to take precedence over scale shown on plans, elevations, sec— <br />tions and details. <br />Any discrepancies on the plans or any deviations from the plans which are necessi— <br />tated by field conditions or any condition different from those indicated on the <br />plans, shall be called to the attention of the Engineer Of Record prior to contin— <br />uing construction. All work is to be coordinated so that cooperation between the <br />trades, where required, is accomplished. <br />The Builder shall take full and final responsibility for constructing a final product of appropriate <br />quality and serviceability consistent with the information and requirements contained in the <br />construction documents or reasonably inferable therefrom, and/or contained in the requirements <br />of any governmental entity with jurisdiction over the project; and in this regard the Builder <br />shall take full responsibility for all construction means, methods, techniques, sequences or <br />procedures including without limitation demolition, excavation and erection procedures; for <br />safety precautions and programs in connection with the project; and for the timeliness or <br />quality of all the work performed pursuant to this agreement. In this regard, the Builder <br />shall indemnify to the fullest extent allowed by law the project's design team, and their <br />respective officers, directors, principals and employees, of and from any and all claims, <br />liability and/or losses which are caused or contributed to by the failure of the builder to <br />honor these obligations, including even liability claims and/or losses involving any indemnities' <br />actual or alleged active negligence or design defects, and excluding only any indemnity's <br />sole negligence or willful misconduct. <br />DISCREPANCIES <br />The Contractor shall compare the structural drawings with the existing site configurations and <br />architectural drawings. All discrepancies shall be reported to the Engineer Of Record and <br />the Owner for proper adjustment before proceeding with the work. <br />OMISSIONS <br />In the event that certain features of the construction are not fully shown on the <br />drawings or called for in the general notes, then their construction shall be of the <br />some character as for similar conditions that are shown or called for. <br />CODES <br />All materials and workmanship shall conform to the California Building Code 2022 Edition <br />and all applicable local codes and ordinances. <br />FASTENER TREATMENT: AS REQUIRED BY THE PRESERVATIVE MFR <br />Hardware and Fasteners in contact with preservative —treated wood shall be approved by the <br />preservative treatment manufacturer, including: silicon bronze or copper, stainless steel or <br />hot —dipped zinc —coated steel and shall be as recommended by the preservative treated lumber <br />manufacturers. Silicon bronze, copper and stainless steel fasteners are acceptable for all <br />ground contact and moisture situations. Hot —dipped zinc —coated nails may be used for <br />basement and crawl space wall construction where polyethylene sheeting is applied to the <br />below —grade portion of the exterior wall and for wood basement floor construction, provided <br />the polyethylene sheeting is placed in accordance with the 2022 CBC. Other types of steel or <br />metal fasteners shall be permitted only if adequate comparative tests for corrosion resistance, <br />including the effects associated with the wood treating chemicals, indicate an equal or better <br />performance. Zinc —coated fasteners shall be coated after manufacture to their final form, <br />including pointing, heating, threading or twisting as applicable. Electroga Ivan ized nails or staples <br />and hot —dipped zinc —coated staples shall not be used. Framing anchors shall be of <br />hot —dipped zinc —coated A-446 Grade A steel. Exception: Where approved, fasteners used in <br />contact with preservative— treated wood products when not below grade or exposed to weather. <br />NAI <br />Minimum connection of wood members shall be in conformance with 2022 CBC Table No. <br />2304.10.1. All nails to be common wire round head nails per ASTM F 1667, <br />U.O.N. Nails in exterior applications shall be corrosion resistant. See below for minimum <br />nails sizes. Where nails tend to split wood, predrill holes 7/8 nail diameter. Nailing not <br />shown in the drawings or noted in the above reference shall be at least two nails at all <br />contact points using 8d thru 1 x minimum and 16d thru 2x material. <br />FRAMING NAILS <br />Size Diameter Length Gauge Head Size Comments <br />8d 0.131 in 2 1 2 in 10.25 9 32 in <br />10d 0.148 in 3 in 9 5/16 in <br />12d 0.148 in 3 1 /4 in 9 5/16 in <br />16d 0.162 in 3 1 /2 in 8 11 /32 in <br />SHEATHING NAILS <br />Size Diameter Length Gauge Head Size Comments <br />8d 0.131 in 1 7 8 in 10.25 9 32 in 3 8 in Sheathing <br />10d 0.148 in 2 1 /4 in 9 5/16 in 1 /2 in Sheathing <br />10d 0.148 in 3 in 9 5/16 in 5/8 in & 3/4 in Sheathing <br />Bolts in wood are 3 4" diameter machine bolts A<S.T.M> A307 unless otherwise noted. Bolt holes <br />in wood shall be 1 16" diameter oversize. Unless otherwise noted, provide 2" o.d. x 9 GA, <br />standard cut washer under head and nut where bolt is bearing against wood. Bolt threads <br />shall not bear against wood. Tighten all nuts when installed and re —tighten prior to covering. <br />MACHINE APPLIED NAILING <br />Use of machine nailing is subject to a satisfactory job site demonstration for each project <br />and the approval by the Engineer Of Record. The approval is subject to continued <br />satisfactory performance. Machine nailing will not be approved in 5/16" plywood. If rail— <br />heads penetrate the outer ply more than would be normal for a hand hammer or if minimum <br />allowable edge distances are not maintained the performance will be deemed unsatisfactory. <br />The pneumatic nailing equipment shall be OSHA approved. <br />HARDWARE <br />Metal framing and premanufactured strong —wall devices shall be as manufactured by Simpson <br />Company, or ICC equivalent. Metal framing and premanufactured strong —wall devices as shown on <br />the drawings are as indicated in the Simpson Company catalog. All devices shall be installed per <br />manufacturer's recommendations. Submit any proposed substitutions to the Engineer Of Record <br />for review prior to construction. All fasteners shall be properly installed in all hardware WITH MAX <br />NAILING. All fasteners used for Simpson products shall be as specified by the manufacturer, U.O.N. <br />Use Simpson WB126 or construction bracing prior to installation of shearwall sheathing. Do Not <br />use let —in bracing. <br />LUMBER <br />Lumber Grades: Standard Grading Rules No. 16, West Coast Lumber Inspection Bureau <br />Light Framing, Studs, Blocking, and Misc. D<F.—L <9' Standard & Better — 550f—b <br />2x4 & 2x6 >9' No.2 & Better — 875f—b <br />Structural Joists & Rafters D.F.—L No.2 & Better — 875f—b <br />2" to 4" thick <br />4" thick and wider D.F.—L No.1 — 1350f—b <br />All framing lumber 6" nominal and larger in the least dimension shall be F.O.H.C. <br />All oists, rafters or beams shall not be notched or cut U.O.N. on the plans. Holes may be <br />drilled through joists and rafters only if the hole size and location is approved by the Engineer. <br />CONSTRUCTION ADHESIVE <br />Loctite T_ Premium Polyurethane construction adhesive at all contact areas with 1 /4" beads <br />in an 'S' pattern 0 3"o.c. <br />BOLTS IN STEEL <br />Bolts in steel are A>S.T.M. 307 x unless otherwise noted. Bolt holes shall be 1/16" diameter <br />oversize unless otherwise noted. Tighten all nuts to 40 ft—lb torque minimum. <br />LAG SCREWS <br />Lag screws are ASTM A307. Lag screws shall be screwed into predrilled holes of the some <br />diameter as the root of the thread. Enlarge hole to shank diameter for the length of the <br />shank. <br />STRUCTURAL STEEL — MISCELLANEOUS META <br />• Angles, channels, and plates: ASTM A36 <br />• Square tubing: ASTM A500 Grade B <br />• Wide flange sections: ASTM A992 — Fy = 50 KSI <br />• Machine bolts, anchor bolts and nuts ASTM A307 <br />• Electrodes for shielded metal arc welding AWS A5.5 E70XX <br />• Electrodes for submerged —arc welding AWS A5.17 F7X—XXX <br />• Welding filler material shall be specified to have a minimum V—Notch toughness of 20 <br />ft—lbs at 0 degrees. <br />• Metal primer shall conform with federal specification TT—P-645A for shop prime coat <br />paint. Apply one coat to all surfaces except at areas of field welding, and where <br />embedded in concrete. All butt welded joints shall be AWS and AISC complete penetration <br />welds. Submit shop and erection drawings for review prior to fabrication. Special Inspection <br />is required for all welding and high strength bolting. A welding sequence shall be planned <br />to minimize residual stresses and distortions of individual members and the building <br />frame. All detailing, fabrication, and erection shall comply with AISC, latest edition. <br />• All fastener nuts shall obtain full purchase with a minimum of one —quarter —inch exposed <br />thread. <br />STEEL SHOP DRAWINGS <br />Manufacturer is to supply shop drawings for all connections and frames. Connections and frames <br />to be fabricated by certified welders, and with special inspection when specified by these <br />drawings. Drawings shall contain the following information for each type of connection and <br />frame. <br />Detail of connections and frames, size and grade of material used, connectors, and fastener <br />sizes and orientation. Drawings shall be of sufficient detail to pass the municipal plan check. <br />Submit descriptive data to illustrate frame erection procedure including sequence of erection and <br />any temporary staging and bracing. Submit proofs of compliance of materials. Certify that <br />materials meet requirements specified. <br />Before submitting shop drawings to the Engineer Of Record, General Contractor shall; review shop <br />drawings for conformance with the means, methods, techniques, sequences and operations of <br />construction, and safety precautions and programs incidental thereto, all of which are the sole <br />responsibility of the General Contractor; approve shop drawings before submitting them; and so <br />stamp the shop drawings before submitting them. Engineer Of Record shall assume that no <br />shop drawing comprises a variation unless the General Contractor advises the Engineer Of Record <br />writing. Engineer Of Record shall return the shop drawings with comments provided that each <br />shop drawing is stamped by the General Contractor. Engineer Of Record shall return without <br />comment, shop drawings not previously approved by the General Contractor. <br />CONSTRUCTION LIABILITY <br />Construction contractor agrees that in accordance with generally accepted construction practices, <br />construction contractor will be required to assume sole and complete responsibility for job site <br />conditions during the course of construction of the project, including safety of all persons and <br />property: that this requirement shall be made to apply continuously and not be limited to <br />normal working hours, and construction contractor further agrees to defend, indemnify and hold <br />design professional harmless from any and all liability, real or alleged, in connection with the <br />performance of work on this project, excepting liability arising from the sole negligence of <br />design professional. <br />REQUESTS FOR INFORMATION <br />All questions, comments, alternate details, and requests for information, etc. are most <br />expeditiously processed by submittal to the Engineer of Record in writing or via <br />MkoontzOsvcse.com or Jtunison®svcse.com. Meeting, verbal, or telephone requests will be given <br />lowest priority, as they require the most administration and time to properly document. Upon <br />receipt of written requests for information, the Engineer of Record shall process the requests in <br />writing and copy the response to the design team. Alternate details requiring the Engineer of <br />Record's review and acceptance, supplemental calculations, drawing revisions, construction bulletins, <br />or other approvals may result in time delay as the owner's authorization for additional engineering <br />services will be required. <br />DRAWING INDEX <br />ISO.1 PROJECT INFO, MAPS, NOTES, & PICTURES <br />S0.2 SITE PLAN <br />S1.1 PARTIAL & LIMITED BALCONY GUARDRAIL END <br />ATTACHMENT REPAIR PLAN & DETAIL <br />CITY OF SANTA ANA <br />Planning dn1d10*b&bency <br />SCOPE OF WORK AlE HOA HAS VOLUNTARILY CHOSEN TO PERFORM PARTIAL & LIMITED REPAIRS FOR THE EXISTING BALCONY METAL GUARDRAIL /'1 <br />ENDS ATTACHMENT ONLY AT THE (33) SUBJECT PROJECT ADDRESS UNITS ONLY. THESE STRUCTURAL ELEMENTS HAVE BEEN FOTbk <br />NP E <br />TO BE DECAYED, DAMAGED, &COMPROMISED. <br />THE PURPOSE OF THESE STRUCTURAL DRAWINGS IS TO DEPICT REMEDIAL CONSTRUCTION THAT WILL INCREASE THE PERFOR ANCE <br />OF THE REPAIRED/REPLACED STRUCTURES & STRUCTURAL ELEMENTS ONLY. MOISTURE PROOFING, FLASHING, TEMPORARY SHORING, <br />VENTILATION AND DECAY PROTECTION ARE NOT A PART OF THESE DRAWINGS AND ARE THE RESPONSIBILITY OF OTHER . <br />LIST <br />REPAIRED <br />OF UNITS <br />TOTAL x <br />TO BE <br />33 UNITS <br />BUILDING <br />#1 <br />UNIT <br />2 <br />BUILDING <br />#1 <br />UNIT <br />6 <br />BUILDING <br />#2 <br />UNIT <br />2 <br />BUILDING <br />#2 <br />UNIT <br />7 <br />BUILDING <br />#3 <br />UNIT <br />2 <br />BUILDING <br />#3 <br />UNIT <br />7 <br />BUILDING <br />#4 <br />UNIT <br />2 <br />BUILDING <br />#4 <br />UNIT <br />6 <br />BUILDING <br />#5 <br />UNIT <br />1 <br />BUILDING <br />#5 <br />UNIT <br />2 <br />BUILDING <br />#5 <br />UNIT <br />4 <br />BUILDING <br />#6 <br />UNIT <br />1 <br />BUILDING <br />#6 <br />UNIT <br />2 <br />BUILDING <br />#6 <br />UNIT <br />4 <br />BUILDING <br />#7 <br />UNIT <br />1 <br />BUILDING <br />#7 <br />UNIT <br />2 <br />BUILDING <br />#7 <br />UNIT <br />4 <br />BUILDING <br />#8 <br />UNIT <br />1 <br />BUILDING <br />#8 <br />UNIT <br />2 <br />BUILDING <br />#8 <br />UNIT <br />4 <br />BUILDING <br />#9 <br />UNIT <br />1 <br />BUILDING <br />#9 <br />UNIT <br />2 <br />BUILDING <br />#9 <br />UNIT <br />4 <br />BUILDING <br />#10 <br />UNIT <br />1 <br />BUILDING <br />#10 <br />UNIT <br />2 <br />BUILDING <br />#10 <br />UNIT <br />4 <br />BUILDING <br />#11 <br />UNIT <br />1 <br />BUILDING <br />#11 <br />UNIT <br />2 <br />BUILDING <br />#11 <br />UNIT <br />4 <br />BUILDING <br />#12 <br />UNIT <br />1 <br />BUILDING <br />#12 <br />UNIT <br />2 <br />BUILDING <br />#12 <br />UNIT <br />4 <br />BUILDING <br />#12 <br />UNIT <br />5 <br />AREA OF WORK: <br />ni IAMMMAii AND <br />A�TAn"LAr KIT <br />PICTURES OF TYPICAL BALCONY <br />Trask Atie <br />COLONIA <br />MANZANILLA <br />Santa Ana College 0 <br />Hazard Ave <br />RIVERVIEW Fairview Village <br />WEST Top rated N <br />Q4 <br />It <br />McFadden Ave <br />Edinger Ave <br />m <br />0 <br />a <br />WINDSOR <br />VILLAGE <br />Edinger Ave <br />W 17th St <br />Date: <br />tsowers i <br />� 1 <br />4 <br />Downtown Santa <br />Ana Historic Dis!rirt <br />wlstSt Santa Ana <br />0 <br />m <br />N <br />HENINGER PARK <br />OHeritage Museum SANTA ANA <br />of Orange County MEMORIAL PARK <br />Mile Square <br />Regional Park <br />w Wainet p..,e <br />m THORNTON PARK 3 <br />In GREEN VALLEY ° Carl Thornton LL <br />q W Segerstrcm Ai,,, n-A, fn <br />GUARDRAIL <br />VICINITY MAP <br />rID: <br />r- <br />0 <br />The Engineer roaerves all rights; and it is <br />illegal to copy or otherwise duplicate, <br />describe, distribute, disseminate, disclose, <br />rouse, or create derivative works from these <br />documents in whole or in part. If you try to <br />My' <br />steal, or distribute all or arty part of <br />this information without our expressed, written <br />permission, our attorneys will contact you and <br />prow legal charges seeking monetary <br />reimbursement for your plagiarism. Likewise, <br />If you are a licensed construction professional <br />you will be reported to the State board, and <br />your license will be revoked due to your <br />plagiarism. We regularly and actively search <br />the industry and exercise our local rights <br />000 <br />CO <br />�21 <br />000 <br />� <br />o <br />LO <br />o <br />a� w00 <br />I <br />W <br />LO <br />r� <br />C0 <br />co <br />0 <br />Cn <br />W <br />W <br />J � <br />J W <br />a� <br />Z ED <br />0� <br />J J) <br />U <br />O <br />Z <br />Z 00 <br />0 arc <br />Z <br />Ifl <br />W <br />rn <br />Q <br />OU <br />p 04 <br />Z LLJ <br />0 <br />QCY <br />C) � <br />IV <br />_ <br />U <br />� z <br />N U) <br />2 <br />0 **� <br />U) o <br />Z Q <br />wWQ <br />HJ(L Qo0 <br />W O O <br />=°0rn <br />J�'-W SOU <br />�3QZ--) zOf <br />J o a=Q <br />Q = �.. � _ <br />H�CU z�-F <br />LL'ZQ V)oz <br />CLOCOQ cn <br />J o <br />m o <br />SCALE 1 /4" = V-0" <br />DATE 07/02/25 <br />PROJECT NO. 250512 <br />SHEET NO. S001 <br />CE <br />1 OF <br />H EETS <br />