ELECTRICAL <br />DETAILS <br />SHEET <br />E-10 EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />T <br />A <br />M <br />P <br />Electrical Mechanical Plumbing <br />333 City Blvd. West, Suite 300 <br />Orange CA 92826 <br />office <br />fax <br />(714) 449-1646 <br />(714) 449-1946 <br />Consulting Engineers <br />3042.07Project Number: <br />Sheet Number <br />Sheet Title <br />PRINT DATE <br />DATE <br />CHECKED <br />DRAWN <br />cad <br />01.08.25 <br />Sorin A. Brie <br />REVISIONS <br />DESCRIPTION DATE <br />SENVENTH <br />FLOOR <br />USABLE: <br />PROJECT <br />TENANT <br />SQUARE FOOTAGE <br />23,000 U.S.F. <br />INTERIOR PLANNING & <br />DESIGN <br />P&D INC. <br />3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 <br />949.724.1499 / www.spaces-oc.com <br />Ma <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />a <br />c <br />e <br />1 <br />M <br />a <br />c <br /> <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />a <br />c <br />e <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />NEW <br />AMERICAN <br />FUNDING <br />WITH ELEVATOR LOBBY <br />AND REST ROOMS <br />SUITE 700/7TH FLR <br />1 <br />M <br />a <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />8 <br />0 <br />0 <br /> <br />( <br />N <br />e <br />w <br /> <br />A <br />m <br />e <br />r <br />i <br />c <br />a <br />n <br /> <br />F <br />u <br />n <br />d <br />i <br />n <br />g <br />) <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br /> <br />1 <br />M <br />a <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />8 <br />0 <br />0 <br /> <br />( <br />N <br />e <br />w <br /> <br />A <br />m <br />e <br />r <br />i <br />c <br />a <br />n <br /> <br />F <br />u <br />n <br />d <br />i <br />n <br />g <br />) <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br /> <br />GENERAL NOTES: <br />2 <br />1 <br />6 <br />CABLE <br />BASKET <br />5 <br />SUSPENDED CEILING <br />GENERAL NOTES: <br />1 <br />NOTES: <br />1. METAL SUPPORT UNIT (DO NOT EXCEED MORE THAN 40% FILL). <br />2. WIRE SUSPENDED FROM STRUCTURE ABOVE. <br />2 <br />3. 18" CLEAR TO SIDE OF CABLE BASKET. <br />4. WALL TERMINATION KIT. <br />5. THREADED ROD ANCHORED TO STRUCTURE ABOVE (SIZED FOR <br />STRUCTURAL SUPPORT). <br />6. 18" MIN. CLEARANCE BETWEEN TOP OF CABLE BASKET AND STRUCTURES <br />RUNNING PARALLEL ABOVE. <br />WALL <br />TERMINATION <br />KIT <br />3 <br />A. REFER TO FLOOR PLANS FOR CABLE BASKET SIZE(S) AND ROUTING. <br />B. TRAPEZE SUPPORT BRACKET MAY VARY. SHOWN HERE AS EXAMPLE ONLY. <br />C. DETERMINE SPAN BETWEEN CABLE BASKET SUPPORTS ACCORDING <br />TO MANUFACTURER'S REQUIREMENTS OR GUIDELINES AND LOCAL <br />SEISMIC CODES. <br />D. ALSO DETERMINE BRACING REQUIREMENTS BASED ON LOCAL SEISMIC <br />CODES. <br />E. SUPPORT CABLE BASKET WITHIN 24" ON BOTH SIDES OF ANY TWO <br />JOINED SECTIONS. <br />F. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE AND HEIGHT. <br />SHOWN HERE FOR CLARITY ONLY. <br />NOTES: <br />1. 6" BETWEEN TOP OF DROP CEILING AND BOTTOM OF CABLE BASKET. <br />2. TRAPEZE SUPPORT BRACKET OR CONSTRUCTION CHANNEL. <br />NOTES: <br />1. OWNER FURNISHED, OWNER INSTALLED MOUNTING BRACKET AND <br />WIRELESS ACCESS POINT. <br />2. TELECOMMUNICATIONS OUTLET BOX. <br />3. OMIT FACEPLATE AND TERMINATE TO 8P8C PLUGS WHEN BRACKET MOUNTS <br />DIRECTLY TO BACKBOX. <br />4. BACKBOX WITH CONDUIT TO ACCESSIBLE CEILING (UON). <br />INACCESSIBLE CEILING <br />1 <br />3 <br />4 <br />2 1 <br />T6.01 <br />NOTES: <br />1. CONNECTOR/MODULE. QUANTITIES/TYPES AS SHOWN ON <br />REFERENCING DETAILS. <br />2. 1 OR 2 GANG FACEPLATE AS REQUIRED. WITH <br />QUANTITIES/TYPES OF CONNECTORS/MODULES AS <br />SHOWN ON REFERENCING DETAILS. <br />3. PROVIDE MUD RING (1 OR 2 GANG OPENING AS <br />REQUIRED). PROVIDE APPROPRIATE LENGTH COLLAR FOR <br />FLUSH INSTALLATION WITH FINISHED WALL SURFACE. <br />4. PROVIDE (1) PULL STRING. <br />5. PROVIDE 4-11/16" SQUARE, 2-1/8" DEEP OUTLET BOX. <br />6. PROVIDE COMPRESSION TYPE STEEL CONNECTOR. <br />7. 1" EMT TO ACCESSIBLE CEILING (UON). <br />8. HORIZONTAL CABLING (PERMANENT LINK). <br />QUANTITIES/TYPES OF CABLES AS SHOWN ON <br />REFERENCING DETAILS. <br />5 <br />4 <br />2 <br />3 <br />6 <br />7 <br />8 <br />1 <br />GENERAL NOTES: <br />5 <br />STRUCTURAL SLAB <br />WALL STUD <br />GYPSUM (TYP) <br />4 <br />3 <br />CABLE BASKET <br />3 <br />5 <br />4 NOTES: <br />18" MIN <br />CLEARANCE <br />2 <br />1 <br />1 <br />2 <br />ACCESSIBLE CEILING <br />SUSPENDED CEILING <br />GENERAL NOTES: <br />A. SECURE CANTILEVER BRACKET TO WALL USING FASTENERS APPROPRIATE TO STUD TYPE. <br />B. DETERMINE CANTILEVER BRACKET SEPARATION ACCORDING TO CABLE BASKET LOAD AND SPAN AND TYPE OF STUD. <br />C. ALSO DETERMINE SUPPORT REQUIREMENTS BASED ON LOCAL SEISMIC CODES. <br />D. SUPPORT CABLE BASKET WITHIN 24" ON BOTH SIDES OF ANY CONNECTION TO A FITTING. <br />E. REFER TO TELECOM FLOOR PLANS FOR CABLE BASKET SIZE(S) AND ARCHITECTURAL PLANS FOR DROP CEILING HEIGHT. <br />F. REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPE AND CEILING TYPE. SHOWN HERE FOR CLARITY ONLY. <br />NOTES: <br />1. CANTILEVER/WALL ATTACH BRACKET ATTACHED TO WALL STUD. <br />2. 6" BETWEEN TOP OF DROP CEILING AND BOTTOM OF CABLE BASKET. <br />3. BUNDLE OF CABLES (EXAMPLE). <br />4. 18" MIN. CLEARANCE BETWEEN TOP OF CABLE BASKET AND STRUCTURES <br />RUN PARALLEL ABOVE. <br />GENERAL NOTES: <br />A. LOCATE CLEARANCES AT MIN. OF 15 FEET INTERVALS. <br />B. LOCATE CLEARANCES AT EVERY BEND, "T", AND CROSS. <br />C. LOCATE CLEARANCES AT EVERY ELEVATION CHANGE. <br />NOTES: <br />1. 8" MIN BETWEEN TOP OF DROP CEILING AND <br />2. 18" CLEARANCE OFF SIDE OF TRAY. <br />3. 24" WIDE CLEARANCE ABOVE TRAY. <br />4. 12" MIN CLEARANCE BETWEEN TOP OF CABLE BASKET. <br />2 <br />1 2 <br />4 <br />4 <br />3 8 <br />7 <br />6 <br />5 <br />3 <br />NOTES: <br />1.(4) 8P8C MODULES. <br />2. LABEL (TYP). <br />3 <br />3. BACKBOX WITH CONDUIT TO <br />ACCESSIBLE CEILING (UON). <br />4. PROVIDE (4) HORIZONTAL <br />CABLES FROM THE OUTLET <br />TO THE NEAREST TR. <br />5. PROVIDE (1) PULL STRING.4 4 <br />1 <br />2 <br />5 <br />4 <br />TELECOMMUNICATIONS <br />CABLES <br />1. CAT425 FABRIC CRADLE. <br />2. CAT425 METAL SUPPORT. <br />3. 3/8" THREADED ROD. <br />4. DRILL FLOOR AND INSTALL EXPANSION INSERT. <br />5. BOTTOM OF DECK. <br />1 <br />NOTES: <br />ACCESSIBLE CEILING <br />NOTES: <br />WIRELESS ACCESS POINT <br />OWNER FURNISHED, <br />OWNER INSTALLED. <br />1. PROVIDE AND INSTALL PATCH CORD TO WAP. <br />2. SECURE SURFACE MOUNT OUTLET TO ACCESSIBLE CEILING. <br />3. SURFACE MOUNT TELECOMMUNICATIONS OUTLET. <br />4. PROVIDE CABLING TO NEAREST TO NEAREST CABLE TRAY. <br />1 <br />2 <br />- <br />---3 <br />2 <br />3 <br />4 <br />CABLE TRAY <br />4 <br />3 <br />1 <br />NOTES: <br />2 <br />3 <br />1 <br />4 <br />GENERAL NOTES: <br />A. REFER TO PLANS FOR TRAY SIZE AND ROUTE. <br />B. USE CABLE SUPPORT OR BASKET TRAY IN <br />NOTES: <br />1. NEATLY COIL 15 FEET OF SLACK. SECURE BELOW BASKET <br />TRAY WITH VELCRO ABOVE WAP LOCATION SHOWN IN DRAWING. <br />2. HORIZONTAL CABLING ROUTE THROUGH UNDERSIDE OF <br />3. CABLE DROP-OUT. <br />4. SURFACE MOUNT BOX (SEPARATE OUTLET BOX FOR EACH <br />1 <br />NOTES: <br />1. WHERE DEVICES SHOWN ON PLANS ARE "BACK TO BACK", <br />INSTALL THE DEVICES IN SEPARATE STUD BAYS TO LIMIT <br />SOUND TRANSFER BETWEEN ROOMS. <br />2. WHERE SPACE CONSTRAINTS AND WALL CONSTRUCTIONS <br />REQUIRE DEVICES TO BE INSTALLED "BACK TO BACK" WITHIN <br />THE SAME STUD BAY, PROVIDE FIRE-STOPPING ACOUSTICAL <br />PADS AROUND BACKBOXES. <br />3. DEVICES IN "BACK TO BACK" CONFIGURATIONS SHALL HAVE <br />SEPARATE CONDUIT PATHWAYS AND SHALL NOT "DAISY- <br />CHAIN". <br />4.IN ADDITION TO DEVICES INSTALLED "BACK TO BACK", <br />PROVIDE AND INSTALL FIRE-STOPPING PADS AROUND ALL <br />BACKBOXES WHERE INSTALLED IN FIRE-RATED WALLS. <br />2 4 <br />WALL <br />BAS <br />K <br />E <br />T <br /> <br />T <br />R <br />A <br />Y <br />DROP C <br />E <br />I <br />L <br />I <br />N <br />G <br />DROP C <br />E <br />I <br />L <br />I <br />N <br />G <br />12 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />12 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />TH <br />I <br />S <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br /> <br />W <br />I <br />L <br />L <br /> <br />V <br />A <br />R <br />Y <br /> <br />P <br />E <br />R <br /> <br />F <br />I <br />E <br />L <br />D <br /> <br />C <br />O <br />N <br />D <br />I <br />T <br />I <br />O <br />N <br />S <br /> <br />A <br />N <br />D <br /> <br />D <br />W <br />G <br />S <br />9 <br />4 <br />TBB 1 <br />14PBB <br />BC <br />6 <br />2 <br />15 <br />3 PNL <br />BC 13 PBB <br />BC 2 <br />6 <br />2 <br />12 <br />PPGC 5 <br />3BC <br />TBC <br />15 <br /># <br />10 <br />NEUTRAL BUS <br />MAIN BONDING <br />JUMPER <br />GROUNDING <br />ELECTRODE <br />CONDUCTOR <br />G <br />GROUND BUS <br />GROUNDING ELECTRODE <br />SYSTEM <br />N 8MSB <br />5 <br />PNL <br />BET <br />7 <br />15 <br />15 <br />12 <br />6 <br />BC 2 <br />BC 3 <br />BC <br />15 11 <br />4 <br />4 <br />4 <br />TYPICAL TELECOMMUNICATIONS OUTLET43SINGLE OUTLET CABLE HANGER1 <br />WIRELESS ACCESS POINT OUTLET INSTALLATION DETAIL <br />(INACCESSIBLE CEILINGS)2 BASKET TRAY SUPPORT - TRAPEZE AND WALL MOUNT BRACKET <br />TELECOMMUNICATIONS OUTLET - TWO PORT87BASKET TRAY WALL SUPPORT5 <br />WIRELESS ACCESS POINT OUTLET INSTALLATION DETAIL <br />(ACCESSIBLE CEILINGS)6 MULTI-OUTLET CABLE HANGER <br />TELECOMMUNICATIONS OUTLET - FOUR PORT13 <br />12 <br />BASKET TRAY WALL SUPPORT9 <br />TYPICAL POWER REQUIREMENTS FOR <br />RACKS/ENCLOSURESWAP OUTLET CONFIGURATION ON BASKET TRAY10 <br />BOTTOM OF CABLE BASKET. <br />ACCESSIBLE CEILING AREAS.BASKET TRAY. <br />CABLING). <br />TYPICAL OUTLET INSTALLATION IN WALLS14 <br />1.TYPICAL RACK SHOWN FOR REFERENCE ONLY. SEE THE DRAWINGS AND SPECIFICATIONS FOR SPECIFIC <br />RACK QUANTITIES, TYPE, STYLE, WIRE MANAGEMENT AND ADDITIONAL ACCESSORIES. <br />2.VERTICAL PDU MOUNTED ON REAR RACK RAILS. PROVIDE (1) ON EACH SIDE OF THE RACK (TYP). <br />3.STRUCTURAL SUPPORT (UNISTRUT P1001 OR EQUAL) PROVIDE MOUNTING HARDWARE AS REQUIRED TO <br />MOUNT RECEPTACLES TO RACEWAY. <br />4.VERTICAL WIRE MANAGERS (TYPE/SIZE AS SHOWN ON THE DRAWINGS AND SPECIFICATIONS)(TYP). <br />5.CABLE TRAY (TYPE/SIZE AS SHOWN ON THE DRAWINGS AND SPECIFICATIONS). <br />6.THREADED ROD (SUSPENDED FROM CEILING)(TYP). <br />7.120VAC OUTLETS. COORDINATE WITH DIV 26 TO PROVIDE ONE (1) DEDICATED 1P-20A CIRCUIT PER RACK, <br />WITH TWO (2) RECEPTACLES, MOUNTED ABOVE THE REAR RAILS (TYP). <br />8.TWIST-LOCK 208/230V OUTLET. COORDINATE WITH DIV 26 TO PROVIDE ONE (1) DEDICATED 2P-30A <br />CIRCUIT PER RACK WITH ONE (1) RECEPTACLE MOUNTED ABOVE THE REAR RAILS (TYP). <br />11 GROUNDING AND BONDING SYSTEM DETAIL <br />1.SIZE AS SHOWN ON THE GROUNDING AND BONDING BACKBONE ONE-LINE DIAGRAM. THE TBB SHALL BE CONTINUOUS. <br />2.WHERE STRUCTURAL STEEL IS IN THE SAME ROOM AS THE PBB/SBB AND READIBLY ACCESSIBLE, PROVIDE BONDING CONDUCTOR (#6 <br />AWG-CU) TO BUILDING STEEL. <br />3.WHERE ELECTRICAL PANELBOARD IS IN THE SAME ROOM AS THE PBB/SBB, PROVIDE BONDING CONDUCTOR (SIZED PER NEC 250.122) TO THE <br />ALTERNATING CURRENT EQUIPMENT GROUND BUS OF THE PANELBOARD. <br />4.PROVIDE TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR (TEBC)(#6 AWG-CU). <br />5.PROVIDE PRIMARY PROTECTOR GROUNDING CONDUCTOR (PPGC)(#6 AWG-CU) TO BUILDING ENTRANCE TERMINAL/PROTECTOR. <br />6.WHERE SHOWN ON THE DRAWINGS, PROVIDE BONDING CONDUCTOR (#6 AWG-CU) TO SUPPLEMENTARY BONDING NETWORK SYSTEMS (E.G. <br />MESH BONDING NETWORKS, SIGNAL REFERENCE GRIDS) . <br />7.PROVIDE TELECOMMUNICATIONS BONDING CONDUCTOR (TBC) TO THE ELECTRICAL SERVICE GROUNDING SYSTEM. THE TBC SHALL BE, AS A <br />MINIMUM, THE SAME SIZE AS THE LARGEST TBB. <br />8.TYPICAL BONDING FOR ALL RACKS IN ALL TRS. (2 POST SHOWN FOR REFERENCE ONLY). SEE THE DRAWINGS AND SPECIFICATIONS FOR <br />SPECIFIC RACK TYPE, STYLE, WIRE MANAGEMENT AND ADDITIONAL ACCESSORIES. <br />9.TO ADDITIONAL TR(S) WHERE SHOWN ON THE GROUNDING AND BONDING BACKBONE ONE-LINE DIAGRAM. <br />10.ELECTRICAL ENTRANCE FACILITY <br />11.BOND TO ALL CABLE TRAYS (TYP). <br />12.TO SBN (WHERE SHOWN). <br />13.2-HOLE COMPRESSION LUG CONNECTION (TYP). <br />14.CABLE TRAY (TYPICAL ALL TRS). <br />15.(BY DIV 26). <br />1. (2) 8P8C MODULES. <br />2. LABEL (TYP). <br />3. BACKBOX WITH CONDUIT TO ACCESSIBLE CEILING (UON). <br />4. PROVIDE (2) HORIZONTAL CABLES FROM THE OUTLET TO THE NEAREST FULL HEIGHT <br />5. PROVIDE (1) PULL STRING. <br />D.REFER TO ARCHITECTURAL DRAWINGS FOR SUSPENDED CEILING TYPE. <br />SHOWN HERE FOR CLARITY ONLY. <br />C.REFER TO ARCHITECTURAL DRAWINGS FOR DECK TYPE. SHOWN HERE <br />FOR CLARITY ONLY. <br />B.SECURE CABLE HANGER TO DECK TO MEET LOCAL SEISMIC CODES. <br />A.SPACE CABLE HANGERS A MAXIMUM 5'-0" ON CENTER WITHIN LAYOUT <br />SHOWN ON FLOOR PLANS. <br />D.REFER TO ARCHITECTURAL DRAWINGS FOR SUSPENDED CEILING TYPE. <br />SHOWN HERE FOR CLARITY ONLY. <br />C.REFER TO ARCHITECTURAL DRAWINGS FOR DECK TYPE. SHOWN HERE FOR <br />CLARITY ONLY. <br />B.SECURE CABLE HANGER TO DECK USING APPROPRIATE FASTENERS TO MEET <br />LOCAL SEISMIC CODES. <br />A.SPACE CABLE HANGERS A MAXIMUM 5'-0" ON CENTER WITHIN LAYOUT SHOWN <br />ON FLOOR PLANS. <br />\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\07\Suite 700 (New American Funding)\1 MacArthur Pl., Suite 700 (New American Funding) E-10 Electrical Details.dwg, 4/15/2025 8:11:39 PM