Laserfiche WebLink
ELECTRICAL <br />DETAILS <br />SHEET <br />E-9 EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />T <br />A <br />M <br />P <br />Electrical Mechanical Plumbing <br />333 City Blvd. West, Suite 300 <br />Orange CA 92826 <br />office <br />fax <br />(714) 449-1646 <br />(714) 449-1946 <br />Consulting Engineers <br />3042.07Project Number: <br />Sheet Number <br />Sheet Title <br />PRINT DATE <br />DATE <br />CHECKED <br />DRAWN <br />cad <br />01.08.25 <br />Sorin A. Brie <br />REVISIONS <br />DESCRIPTION DATE <br />SENVENTH <br />FLOOR <br />USABLE: <br />PROJECT <br />TENANT <br />SQUARE FOOTAGE <br />23,000 U.S.F. <br />INTERIOR PLANNING & <br />DESIGN <br />P&D INC. <br />3150 BRISTOL, SUITE 205/COSTA MESA, CA 92626 <br />949.724.1499 / www.spaces-oc.com <br />Ma <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />a <br />c <br />e <br />1 <br />M <br />a <br />c <br /> <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />a <br />c <br />e <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />NEW <br />AMERICAN <br />FUNDING <br />WITH ELEVATOR LOBBY <br />AND REST ROOMS <br />SUITE 700/7TH FLR <br />1 <br />M <br />a <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />8 <br />0 <br />0 <br /> <br />( <br />N <br />e <br />w <br /> <br />A <br />m <br />e <br />r <br />i <br />c <br />a <br />n <br /> <br />F <br />u <br />n <br />d <br />i <br />n <br />g <br />) <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br /> <br />1 <br />M <br />a <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br /> <br />P <br />l <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />8 <br />0 <br />0 <br /> <br />( <br />N <br />e <br />w <br /> <br />A <br />m <br />e <br />r <br />i <br />c <br />a <br />n <br /> <br />F <br />u <br />n <br />d <br />i <br />n <br />g <br />) <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br /> <br />7 TYPICAL TEL. BOARD GROUNDING BAR INSTALLATION <br />DO NO <br />T <br />DISCO <br />N <br />N <br />E <br />C <br />T <br />3 <br />- <br />PANELS NAMEPLATE4 <br />DIST. PANEL CRPP1A1 <br />DIST. PANEL CRPP1A1 <br />PURPLE <br />ORANGE <br />NOT PAINTED <br />RED <br />YELLOW <br />BLUE & WHITE <br />GREEN & BLUE <br />ORANGE & WHITE <br />NOT PAINTED <br />PVC-NOT PAINTED <br />GENERAL NOTES: <br />COLOR <br />J-BOX PAINT <br />GROUND CONDUITS <br />480V NORMAL <br />208/120V NORMAL <br />SECURITY <br />TELECOM <br />FIRE ALARM <br />BMS CONTROLS <br />208/120V UPS <br />480/277V UPS <br />277V NORMAL (LTG.) <br />SERVICE <br />GREEN WHITE GREEN <br />BLUE <br />BLUE & WHITE <br />ORANGE & WHITE <br />GREEN & BLUE <br />YELLOW <br />RED <br />WHITE <br />ORANGE <br />CONDUIT TAPE <br />COLOR LEGEND <br />COLOR <br />PURPLE <br />BLUEWHITE <br />BLACK <br />BLACK <br />WHITE <br />WHITE <br />WHITE <br />WHITE <br />WHITE <br />YELLOW <br />BLACK <br />RED <br />WHITE <br />BLUE <br />ORANGE <br />ORANGE <br />NAMEPLATE COLOR <br />WHITE DARK PURPLE <br />PANEL CRPP1A1 <br />BRPP1A1-22,24,26 <br />3 RACEWAY AND NAMEPLATE IDENTIFICATION <br />TELEPHONE/DATA OUTLETS8 <br />2 ESD GROUNDING FOIL CONNECTION AT RECEPTACLE <br />EQUIPMENT MOUNTED RECEPTACLE DETAIL6 <br />GROUNDING AND BOUNDING9 <br />LOCK NUT <br />1. WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE <br />MANNER DESCRIBED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND <br />SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY <br />102 MM) LUMBER SPACED MAX 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) DEEP, FABRICATED FROM 25 MSG GALV STEEL, SPACED <br />MAX 24 IN. (610 MM) OC. <br />B. GYPSUM BOARD* -- THE GYPSUM BOARD TYPE, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE <br />INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OPENING IS 12 IN. (305 MM). <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. <br />2. THROUGH PENETRANT -- ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE <br />FIRESTOP SYSTEM. THE MIN ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 IN. <br />(POINT CONTACT) TO MAX 7-7/8 IN. (200 MM). PIPE CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE <br />FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBES MAY BE USED: <br />A. STEEL PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE -- NOM 4IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT. <br />D. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT. <br />E. COPPER TUBING -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />F. COPPER PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />3. FIRESTOP SYSTEM -- THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL -- GLASS FIBER OR MINERAL WOOL BATT INSULATION FIRMLY PACKED WITHIN THE WALL CAVITY AROUND THE OPENING AS A <br />PERMANENT FORM. <br />B. FILL, VOID OR CAVITY MATERIAL*-FOAM -- FILL MATERIAL APPLIED WITHIN ANNULUS FLUSH WITH BOTH SURFACES OF THE WALL. MIN FILL <br />MATERIAL THICKNESS FOR 1 HR F RATING IS 4-3/4 IN. (121 MM). MIN FILL MATERIAL THICKNESS FOR 2 HR F RATING IS 6 IN. (152 MM). <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 FIRE FOAM <br />*BEARING THE UL CLASSIFICATION MARK <br />Hilti Firestop Systems <br />A <br />A SECTION A-A <br />WL <br /> <br />1 <br />2 <br />8 <br />9 <br />System No. W-L-1289 <br />F Ratings -- 1 and 2 Hr (See Items 1 and 3) <br />T Rating -- 0 Hr <br />L-RA TING AT AMBIENT = LESS THAN 1 CFM / SQ FT <br />L Rating at Ambient -- Less Than 1 CFM/sq ft <br />L Rating at 400 F -- Less Than 1 CFM/sq ft <br />UL 1479 and CAN/ULC-S115 <br />A <br />A <br />F RATING - 2 HR <br />T RATING - 2 HR <br />ANSI / UL1479 (ASTM E814) <br />- 2 HR <br />- 0 HR <br />- 2 HR <br />- 0 HR <br />F RATING <br />FT RATING <br />FH RATING <br />FTH RATING <br />CAN / ULC S115 <br />1. WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN <br />THE MANNER DESCRIBED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE <br />DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 <br />BY 4 IN. (51 BY 102 MM) LUMBER SPACED MAX 16 IN. (406 MM) OC. STEEL STUDS TO BE MIN 3-1/2 IN. (89 MM) DEEP, FABRICATED FROM 25 <br />MSG GALV STEEL, SPACED MAX 24 IN. (610 MM) OC. <br />B. GYPSUM BOARD* -- THE GYPSUM BOARD TYPE, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS <br />SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OPENING IS 12 IN. (305 MM). THE HOURLY F RATING OF THE <br />FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. <br />2. THROUGH PENETRANT -- ONE METALLIC PIPE, CONDUIT OR TUBE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN <br />THE FIRESTOP SYSTEM. THE MIN ANNULAR SPACE BETWEEN THE PIPE, CONDUIT OR TUBE AND THE PERIPHERY OF THE OPENING <br />SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 7-7/8 IN. (200 MM). PIPE CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF <br />WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBES MAY BE USED: <br />A. STEEL PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE -- NOM 4IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT. <br />D. CONDUIT -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT. <br />E. COPPER TUBING -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />F. COPPER PIPE -- NOM 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />3. FIRESTOP SYSTEM -- THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: <br />A. PACKING MATERIAL -- GLASS FIBER OR MINERAL WOOL BATT INSULATION FIRMLY PACKED WITHIN THE WALL CAVITY AROUND THE <br />OPENING AS A PERMANENT FORM. <br />B. FILL, VOID OR CAVITY MATERIAL*-FOAM -- FILL MATERIAL APPLIED WITHIN ANNULUS FLUSH WITH BOTH SURFACES OF THE WALL. MIN <br />FILL MATERIAL THICKNESS FOR 1 HR F RATING IS 4-3/4 IN. (121 MM). MIN FILL MATERIAL THICKNESS FOR 2 HR F RATING IS 6 IN. (152 MM). <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 FIRE FOAM <br />*BEARING THE UL CLASSIFICATION MARK <br />System No. F-A-1014 <br />FA <br /> <br />1 <br />0 <br />1 <br />4 <br />Hilti Firestop Systems <br />10 11 <br />DOUBLE DOOR WITH CONTACT, <br />CARD READER, ELECTRIC LOCK <br />& REX <br />SINGLE DOOR WITH CONTACT, <br />CARD READER, ELECTRIC LOCK <br />& REX <br />FLOOR / SLAB PENETRATION DETAIL5 <br />RATED WALL PENETRATION DETAIL1 <br />\\192.168.13.204\Esi-Files\Projects\Santa Ana\MacArthur Plaza\1 MacArthur Plaza\07\Suite 700 (New American Funding)\1 MacArthur Pl., Suite 700 (New American Funding) E-9 Electrical Details.dwg, 4/15/2025 8:11:35 PM