Laserfiche WebLink
ELASTOMERIC PVC COOL ROOFING <br />SYSTEM MEMBRANE PER SPEC 07 53 10 <br />2" POLYISO INSUALTION FOAM <br />(E) 2X STRUCTURAL FRAMING <br />ROOF PLATE HT. <br />BATT INSULATION PER <br />SPECIFICATIONS AND T-24 <br />(E) 2X STRUCTURAL FRAMING <br />(E) BATT INSULATION <br />NOTE: FLAME SPREAD/SMOKE <br />DENSITY RATING OF INSULATION: <br />MAXIMUM 25/450, ASTM E84. <br />ELASTOMERIC PVC COOL ROOFING <br />SYSTEM MEMBRANE PER SPEC 07 53 10 <br />2" POLYISO INSULATION FOAM <br />(E) PLYWOOD TO REMAIN, TYP. <br />(E) SHEET METAL FLASHING WITH <br />INTERLOCKING LAPS <br />(N) PVC MEMBRANE HEAT WELDED TO ROOF MEMBRANE <br />OVER BASE FLASHING TO EXTEND 6" MIN. BEYOND CANT <br />(E) METAL SCREED <br />(E) EXTERIOR CEMENT PLASTER O/ METAL LATH & <br />BUILDING PAPER O/ EXTERIOR SHEATHING AS <br />NEED PER ELEVATION. <br />(E) PLYWOOD SHEATHING <br />1 <br />1 <br />/ <br />2 <br />" <br />2" POLYISO INSULATION FOAM. <br />(N) MECHANICAL UNIT <br />METAL CURB FURNISHED WITH <br />MECHANICAL UNIT - SLOPED TO <br />MATCH ROOF <br />BASE FLASHING 6" MIN. ON FIELD <br />(E) PLYWOOD SHEATHING <br />2" POLYISO INSULATION FOAM <br />8" <br /> <br />M <br />I <br />N <br />(N) WOOD NAILER FOR ROOF <br />MEMBRANE ATTACHMENT <br />(INTEGRAL W/ CURB) <br />ELASTOMERIC PVC MEMBRANE TO <br />EXTEND OVER BASE FLASHING UP <br />UNDER MECH. EQUIPMWENT, TYP. <br />(N) TERMINATION BAR PER <br />MANUF. RECOMMENDATION <br />ELASTOMERIC PVC COOL ROOFING <br />SYSTEM MEMBRANE PER SPEC 07 53 10 <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />(N) PRE-MANUFACTURED STEEL LADDER: <br />2 1/2" X 3/8" FLAT STEEL SIDE RAILS <br />WALL TYPE PER PLAN <br />LADDER RUNG: 18" WIDE X 3/4" FLAT DIA. <br />SOLID STEEL SPACED 12" APART <br />(5" + 8 1/4" x 1/4" Th. x 2" wide) LADDER <br />BRACKET EA. SIDE @ 5'-0" O.C. W / (2) 3" <br />ANCHOR BOLTS <br />PROVIDE FIRE CAULKING AT PENETRATIONS <br />WHERE RATED WALL OCCURS <br />FOR ROOF HATCH, REFER TO DETAIL <br />1 <br />A14.1 <br />BASE PLATE 4" X 8" X 3/8" WITH (2) <br />1/2" DIA. PER STRUCTURAL <br />TOE CLR. <br />7" MIN. <br />EACH BRACKET <br />3/16 <br />PLUMBING ROOF VENT <br />CARLISLE SURE-FLEX PVC <br />PRE-MOLDED PIPE <br />FLASHING, INSTALL PER <br />MFR. SPECIFICATIONS <br />1-1/2" HOT-AIR WELD MIN. ALONG <br />ENTIRE MEMBRANE EDGE. <br />PLYWOOD SHEATHING PER STRUCTURAL <br />TYPICAL ROOF ASSEMBLY, SEE DETAIL <br />2 / A14.0. <br />CARLISLE FASTENER & SEAM FASTENING <br />PLATE, MAX. 12" O.C. <br />STAINLESS STEEL <br />CLAMPING RING. <br />WATER CUT-OFF <br />MASTIC <br />CL <br />PIPE OR CONDUIT PENETRATION SEE ELECTRICAL <br />AND PLUMBING PLANS FIELD MEASURE PIPE <br />LOCATIONS AND SIZES <br />STAINLESS STEEL SCREW CLAMP <br />AT EACH PIPE OR CONDUIT <br />ELASTOMERIC SEALANT ALL AROUND <br />NOTE: <br />1. FOR USE AT MULTIPLE PIPES CLOSER <br />THEN 6" TO 1" APART. USE SINGLE FLANGE <br />FIELD SOLDERED FLASHING. <br />2.FOR ADDITIONAL INFORMATION, <br />SEE <br />MIN. <br />12" <br />6" <br />MIN. <br />6" <br />MIN. <br />ROOFING INTERPLY <br />SET <br />IN ADHESIVE <br />ROOFING BASE <br />SHEET, <br />SET IN ADHESIVE <br />ACRYLIC COATING OVER ROOFING <br />CAP SHEET W/ MINERAL <br />GRANULAR <br />SURFACE SET INTO ADHESIVE. <br />FIRST LAYER OF BASE FLASHING <br />SHEET <br />SET IN ROOF CEMENT <br />4 LB TWO PIECE LEAD FLASHING SLEEVE <br />WITH CONTINUOUS LEAD SOLDER AT SEAMS. <br />SET PRIMED FLANGES INTO ASPHALT ROOF <br />CEMENT OVER ROOFING PLY SHEET <br />SECOND LAYER OF BASE <br />FLASHING <br />SHEET SET IN ROOF CEMENT <br />8 <br />A14.0 <br />6" <br />4" <br />6" <br />6" <br />1/ <br />2 <br />" <br /> <br />T <br />O <br /> <br />3 <br />/ <br />4 <br />" <br />2 <br />3 <br />/ <br />4 <br />" <br />3/ <br />4 <br />" <br /> <br />T <br />O <br /> <br />1 <br />" <br />6" <br />3 <br />3 <br />/ <br />4 <br />" <br /> <br />T <br />O <br /> <br />4 <br /> <br />1 <br />/ <br />4 <br />" <br />3" 3" <br />ROOF CEMENT SHALL BE INSTALLED BETWEEN THE ENDS AT ALL JOINTS, SIX INCHES EACH SIDE <br />OF JOINT. EACH JOINT SHALL BE NAILED WITH A MINIMUM OF FOUR NAILS, TWO ON SIDE OF THE <br />JOINT. ALL JOINTS AND MITERS SHALL BE OVERLAPPED A MINIMUM OF FOUR INCHES. <br />EDGE FLASHING JOINT <br />NOTES: <br />INSIDE EDGE FLASHING CAP <br />CUT HEM <br />TO <br />INTERLOCK <br />AT JOINTS <br />OUTSIDE EDGE FLASHING CAP <br />PREFABRICATED EDGE FLASHING <br />CAP WITH FULLY SOLDERED SEAMS <br />FLANGE NAILING PATTERN <br />ENLARGED DETAIL <br />NOTCH <br />COUNTERFLASHING LAP JOINT <br />PREFABRICATED INSIDE <br />4" MIN.4" MIN. <br />MIN. <br />1" <br />COUNTERFLASHING LAP JOINT <br />COUNTERFLASHING LAP JOINT <br />PREFABRICATED OUTSIDE <br />3" MIN. <br />4" MIN.4" MIN. <br />1" <br />MIN. <br />NOTES: <br />1. CLAMPING RINGS MUST BE USED ON ALL ROOF & OVERFLOW DRAINS. <br />2. REPLACE OR REPAIR ANY AND ALL MISSING, BROKEN OR DAMAGED DRAIN PARTS TO RESULT IN <br />A FUNCTIONING ASSEMBLY. <br />3. AFTER COMPLETE INSTALLATION OF THE ROOFING SYSTEM, CONTRACTOR SHALL INSPECT AND <br />TEST ALL ROOF DRAINS TO ASSURE THAT NO CLOGGING OF THE DRAINAGE SYSTEM IS PRESENT. <br />THE ROOF DRAIN LEADER SHOULD BE IN SUCH CONDITION THAT THE FULL DIAMETER OF THE <br />DRAIN LEADER IS CLEAR. <br />4. MEMBRANE SHALL EXTEND UNDER CLAMPING RING. <br />5. CONTRACTOR SHALL VERIFY DRAIN SIZE TO BE USED AND INCREASE SUMP SIZE TO PROVIDE <br />MINIMUM CLEARANCES. <br />6. OVERFLOW DRAINS ARE ACCOUNTED FOR WITH EXIST, SCUPPERS, TYP. <br />1' <br /> <br />- <br /> <br />0 <br />" <br /> <br />1 <br />' <br /> <br />- <br /> <br />0 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" 1' - 0" <br />2' - 0" <br />ROOF DRAIN ASSEMBLYTYPICAL <br />ROOFING <br />ASSEMBLY, SEE <br />DET. <br />DRAIN SUMP AREA @ <br />3:12 SLOPE RATIO <br />JOISTS PER <br />STRUCTURAL <br />WOOD BLOCKING PER <br />STRUCTURAL DRAWINGS <br />UNDERDECK CLAMP <br />INSULATE ALL ROOF DRAIN <br />PIPING THROUGH INTERIOR <br />SPACES <br />1-1/2" HOT-AIR WELD MIN. ALONG <br />ENTIRE MEMBRANE EDGE. <br />CL <br />MANUF. FASTENER AND <br />DISC - SECURE AS REQ'D. <br />CLAMPING RING <br />PRE-TAPERED EDGE <br />STRIP - FASTEN <br />SECURELY AS REQ'D. <br />a1' -0" <br />/2 A14.0 <br />1/8" BEAD DIAM. BEAD OF CUT- <br />EDGE SEALANT IS REQUIRED ON <br />CUT EDGES OF REINFORCED <br />TPO MEMBRANE. <br />WATER CUT-OFF <br />MASTIC <br />(N) SHEET METAL COUNTER <br />FLASHING <br />(N) PVC MEMBRANE HEAT WELDED TO ROOF MEMBRANE <br />OVER BASE FLASHING TO EXTEND 6" MIN. <br />(E) PRECAST CONCRETE PARAPET WALL <br />(E) PLYWOOD SHEATHING <br />8" <br /> <br />M <br />I <br />N <br />. <br />2" POLYISO INSULATION FOAM. <br />(N) POLYUREATHANE SEALANT <br />(N) COMPRESSIBLE TAPE TO <br />SPAN IRREGULARITIES <br />(E) 26 GA. GALV. SHEET METAL SCUPPER <br />PAINT TO MATCH ADJACENT WALL COLOR <br />DRIP EDGE <br />6 <br />1 <br />/ <br />6 <br />4 <br />" <br />WALL PER PLANS <br />(E) SCUPPER FLANGE <br />ELASTOMERIC PVC COOL ROOFING SYSTEM <br />MEMBRANE PER SPEC 07 53 10, EXTEND INTO <br />SCUPPER 6", TYP. INSTALL PER MNF. <br />SPECIFICATIONS. <br />(N) SHEET MTL. COUNTER FLASHING. <br />ROOF DRAIN PER <br />DETAIL 5 / A14.0 <br />DENSDECK WATEPROOF PROTECTION BOARD <br />OVER TAPERED POLYISOINCURATE <br />INSULATION SLOPED TO DRAIN SEE DETAIL 3 / <br />A14.0 FOR ADDITIONAL INFORMATION <br />SLOPE TO <br />DRAIN <br />3" <br />CL <br />WATER CUT-OFF <br />MASTIC <br />2X WOOD NAILER <br />EPDM PRIMER <br />WA <br />L <br />L <br />PA <br />R <br />A <br />P <br />E <br />T <br />3" <br />3" <br />3" <br />LAP SEALANT <br />(E) 26 GA. GALV. SHEET <br />METAL SCUPPER <br />PAINT TO MATCH <br />ADJACENT WALL COLOR <br />3" <br />WATER CUT-OFF <br />MASTIC UNDER <br />SCUPPER FLANGES <br />6" <br />FIRST <br />THIRD <br />SECOND <br />(E <br />) <br /> <br />R <br />O <br />O <br />F <br /> <br />A <br />S <br />S <br />E <br />M <br />B <br />L <br />Y <br />(N) PAC-CLAD SNAP CLAD <br />STANDING SEAM METAL <br />ROOFING PANEL, COLOR: <br />SANDSTONE. <br />(E) PLYWOOD SHEATHING. <br />2" POLYISO INSULATION <br />FOAM, SLOPED TO DRAIN <br />PER ROOF PLAN. <br />(N) PVC MEMBRANE PER <br />SPEC 07 53 10. <br />(N) PAC-CLAD HT <br />UNDERLAYMENT <br />SLIP FLASHING. <br />#10-13 X 1" GP FASTNER. <br />2" <br />2" <br />PVC MEMBRANE21". <br />RETAINER CLIP. <br />TAPE SEALANT <br />SLIP FLASHING7 1/2" <br />SEALANT. <br />(E) ROOF STRUCTURE AND <br />ISULATION TO REMAIN. <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />07/08/24 <br />A14.0 <br />ROOF DETAILS <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />1 1/2" = 1'-0"1ROOF CEILING ASSEMBLY <br />3" = 1'-0"2TYPICAL ROOFING ASSEMBLY <br />3" = 1'-0"4BASE FLASHING AT ROOF STOREFRONT <br />3" = 1'-0"6MECHANICAL UNIT FLASHING1 1/2" = 1'-0"7(N) ACCESS LADDER @ CONCRETE WALL <br />3" = 1'-0"8PLUMBING PIPE PENETRATION AT ROOF <br />1 1/2" = 1'-0"9MULTIPLE PIPE PENETRATIONS <br />1 1/2" = 1'-0"12EDGE FLASHING DETAILS1 1/2" = 1'-0"13TYP. SURF. MTD. COUNTER FLASHING <br />1" = 1'-0"5ROOF DRAIN FLASHING <br />3" = 1'-0"3PARAPET WALL BASE FLASHING <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25 <br />2 ASI #02 06/24/25 <br />3 ASI #03 07/02/25 <br />4 ASI #04 09/18/25 <br />1 1/2" = 1'-0"11SCUPPER DETAIL <br />OMIT <br />3" = 1'-0"10SLOPED ROOF @ TRANSITION DETAIL <br />4 <br />4 <br />4 <br />4 <br />4 <br />4