My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CITY PROJECT - 122 N Newhope St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
N
>
Newhope St
>
122 N Newhope St
>
CITY PROJECT - 122 N Newhope St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2026 5:00:21 AM
Creation date
2/14/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20181614
20187816
30146654
30149839
40138647
40141206
101117571
101117572
101126304
Full Address
122 N Newhope St
Street Number
122
Street Direction
N
Street Name
Newhope
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STEEL OR <br />WOOD <br />DECK TYPE <br />HP-XA <br />FASTENER & PRESSURE PLATE TYPES FOR <br />DIFFERENT ROOF <br />DECKS <br />STRUCTURAL <br />CONCRETE <br />OPTION FASTENER PLATE <br />B <br />A <br />B <br />HP-XTRA <br />CD-10 <br />HD 14-10 PIRANHA <br />PIRANHA <br />PIRANHA <br />PIRANHA XTRA <br />FIELD-FABRICATED PIPE FLASHING <br />XX <br />X <br />X <br />XX <br />X <br />X <br />NOTES: <br />1. REMOVE ALL EXISTING LEAD AND FLASHING MATERIAL <br />BEFORE INSTALLING FIELD FABRICATED PIPE FLASHING. <br />2. TEMPERATURE OF THE PIPE PENETRATION MUST NOT <br />EXCEED 160°F (71°C). <br />3. TPO NON-REINFORCED FLASHING WRAPPED AROUND <br />PIPE SHALL HAVE MINIMUM 1-1/2" (4cm) VERTICAL <br />HOT AIR WELD.INSTALL A MINIMUM OF 4 SEAM <br />FASTENING PLATES FOR PIPES WITH A DIAMETER UP <br />TO 6" (15cm). ADDITIONAL SEAM FASTENING PLATES <br />WILL BE REQUIRED FOR PIPES GREATER THAN 6" <br />(15cm) IN DIAMETER AND SHALL BE SPACED 12" <br />(30cm) ON CENTER MAXIMUM. <br />4. FASTENERS/PLATES ARE NOT REQUIRED ON ADHERED <br />SYSTEMS UNLESS PIPE DIAMETER EXCEEDS 18" <br />(50cm). <br />5. APPROXIMATELY 1/8" (0.5cm) DIAMETER BEAD OF <br />CUT-EDGE SEALANT IS REQUIRED ON CUT EDGES OF <br />REINFORCED TPO MEMBRANE. <br />1/2" 1.5 <br />A <br />MIN. <br />cmDIMENSIONS <br />1"2.5 <br />1-1/2" 4 <br />B <br />TO <br />2" 5 <br />C <br />12" 30D APPROX. <br />MIN. <br />CARLISLE FASTENER <br />& SEAM FASTENING <br />PLATE, MAX. 12" <br />(30cm) O.C. <br />TPO NON- <br />REINFORCED <br />FLASHING <br />CUT-EDGE <br />SEALANT <br />℄ <br />5 <br />D <br />C <br />A <br />B <br />WATER <br />CUT-OFF <br />MASTIC <br />STAINLESS STEEL <br />CLAMPING RING <br />BY OTHERS <br />HOT AIR-WELD, <br />1-1/2" (4cm) MIN. <br />4 <br />DETAIL NOT FOR USE ON 25 OR 30-YEAR WARRANTY PROJECT. PRE-FABRICATED/PRE-MOLDED <br />ACCESSORIES MUST BE UTILIZED. ACCEPTABLE PIPE FLASHINGS SHALL CONFORM WITH TPO <br />UNIVERSAL DETAILS U-8A, U-8C OR U-8D.CA <br />U <br />T <br />I <br />O <br />N <br />C CO <br />L <br />D <br /> <br />P <br />I <br />P <br />E <br />REINFORCED TPO <br />HOT AIR-WELD, <br />1-1/2" (4cm) <br />MIN. <br />U-8B <br />STOREFRONT SYSTEM SILL. <br />FASTEN PER FABRICATOR'S SHOP <br />DRAWINGS. SEAL AROUND <br />FASTENER PENETRATION <br />4"x4" WITH 1/4" PAN, 23 GA. <br />STAINLESS STEEL FLASHING <br />SET IN FULL BED SEALANT <br />SELF ADHERED <br />FLEXIBLE FLASHING <br />1/4" FINISH CAULK <br />JOINT (TYP.) <br />FINISH GRADE <br />WHERE OCCURS <br />(E) CONCRETE SLAB <br />OR CURB <br />1" <br />EXPANSION BOARD <br />SEALANT JOINT WITH <br />BACKER ROD <br />FLOORING AS <br />SCHEDULED <br />2" <br />F. <br />O <br />. <br />C <br />O <br />N <br />C <br />. <br />EXTERIOR PAVING PER <br />LANDSCAPE AND CIVIL DWGS <br />EXISTING GLULAM BEAM <br />WITH ROUTED DRIP <br />1/2" SEALANT JOINT WITH <br />BACKER ROD <br />STOREFRONT SYTEM HEAD. <br />FASTEN PER FABRICATOR'S <br />SHOP DRAWINGS <br />4"x1"x24 GA. G.S.M. <br />FLASHING BEHIND FACE <br />BEAM <br />SOLID BLOCKING <br />5/8" GYPSUM WALLBOARD. <br />FINISH AS SCHEDULED <br />1/4" FINISH CAULK JOINT <br />(E) GLULAM BEAM <br />STOREFRONT SYSTEM SILL. <br />FASTEN PER FABRICATOR'S SHOP <br />DRAWINGS. SEAL AROUND <br />FASTENER PENETRATION <br />24 GA. G.S.M. SILL FLASHING. 4" <br />VERT, 1/4" LIP BEHIND <br />STOREFRONT SILL PAN.SHIM TO <br />SLOPE 1/2" AND PRVIDE 1/4" <br />HEMMED DRIP EDGE <br />SELF ADHERED FLEXIBLE <br />FLASHING AROUND OPENING <br />EXISTING GLULAM BEAMS <br />SOLID BLOCKING <br />5/8" GYPSUM WALLBOARD. <br />FINISH AS SCHEDULED <br />1/4" FINISH CAULK JOINT <br />PRECAST TILT-UP <br />CONCRETE PANEL PER PLAN <br />2X4 WOOD STUD FRAMING <br />5/8" GYPSUM WALLBOARD. <br />FINISH AS SCHEDULED <br />ALUM BRAKE METAL CLOSURE. <br />FASTEN RECIEVERS TO SUBSTRATES <br />PER FABRICATOR'S SHOP DRAWNGS <br />STOREFRONT SYSTEM JAMB. FASTEN <br />PER FABRICATOR'S SHOP DRAWINGS <br />1/2" SEALANT JOINT WITH BACKER ROD <br />1/4" FINISH CAULK JOINT <br />1" <br />THERMAL INSULATION <br />PER ENERGY REPORT <br />SADDLE FLASHING SET <br />IN 1" BEAD OF SEALANT <br />12" <br />4" <br />4" <br />2" <br />12" <br />2" <br />STOREFRONT FRAME <br />1/2" SEALANT JOINT WITH <br />BACKER ROD (TYP.) <br />RETURN FLASHING 2" BEHIND <br />STOREFRONT FRAME JAMB AND <br />HEAD FACE. MATCH ANGLE OF <br />STOREFRONT HEAD <br />1/2" <br />1/ <br />2 <br />" <br />(E) PRECAST TILT-UP WALL PANEL <br />ALUM. BRAKE METAL CLOSURE. <br />FINISH TO MATCH STORE FRONT <br />FRAME <br />4" <br />WIDTH OF <br />CONCRETE <br />PARAPET <br />3-COAT EXTERIOR CEMENT <br />PLASTER SYSTEM OVER SADDLE <br />FLASHING. LAP MANSARD RAKE <br />EDGE FLASHING OVER EXTERIOR <br />FINISH PER DETAIL #8 AND #11 <br />ABOVE <br />(E) FLAT ROOF PER PLAN <br />MANSARD RAKE EDGE FLASHING <br />(E) CONCRETE <br />PARAPET <br />(N) ALUM. STORE <br />FRONT SYSTEM <br />TYPICAL FLASHING NOTES: <br />1. 24 GA. G.S.M. SADDLE FLASHING. <br />2. SOLDER ALL SEAMS. <br />3. PAINT EXPOSED SURFACES. <br />(N) ROOFING MEMBRANE <br />(E) ASPHALT SHINGLE ROOFING <br />4" <br />(E) ASHPHALT COMPOSITION <br />SHINGLES OVER (E) UNDERLAYMENT <br />(N) 24 GA. G.S.M. RAKE EDGE <br />FLASHING WITH 1/2" RIDGE, 4" VERT <br />AND 6" HORIZ. - PAINTED <br />(E) 1/2" PLYWOOD ROOF SHEATHING <br />1x WOOD PLASTER STOP <br />3-COAT EXTERIOR CEMENT <br />PLASTER SYSTEM <br />(E) RAKE BEAM <br />5/8" GYPSUM WALLBOARD. <br />FINISH AS SCHEDULED <br />PLASTER J-MOULD WITH 1/4" <br />HEMMED DRIP EDGE <br />1/2" SEALANT JOINT WITH <br />BACKER ROD <br />STOREFRONT SYSTEM HEAD. <br />FASTEN PER FABRICATOR'S <br />SHOP DRAWINGS <br />(E) ASHPHALT COMPOSITION <br />SHINGLES OVER (E) UNDERLAYMENT <br />(N) 24 GA. G.S.M. RAKE EDGE <br />FLASHING WITH 1/2" RIDGE, 4" VERT <br />AND 6" HORIZ. - PAINTED <br />(E) 1/2" PLYWOOD ROOF SHEATHING <br />1x WOOD PLASTER STOP <br />3-COAT EXTERIOR CEMENT <br />PLASTER SYSTEM <br />(E) RAKE BEAM <br />2-PIECE PLASTER WEEP <br />SCREED/SNAPLOCK <br />FLASHING <br />ROOF MEMBRANE. TURN <br />UP 8" TERMINATION BAR <br />AND FASTENING PER <br />MENUFACTURER'S <br />REQUIREMENTS AND <br />RECOMMENDATIONS <br />(E) FLAT ROOF PLYWOOD SHEATHING <br />3" <br /> <br />M <br />I <br />N <br />. <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />07/08/24 <br />A62.0 <br />STOREFRONT <br />DETAILS <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />3" = 1'-0"1SILL AT CONC <br />3" = 1'-0"2JAMB AT POST <br />3" = 1'-0"3HEAD <br />3" = 1'-0"4SILL AT FRAMING <br />3" = 1'-0"5JAMB AT SLOT <br />3/4" = 1'-0"6SLOT FLASHING <br />3" = 1'-0"8HEAD AT RIDGE <br />STOREFRONT SYSTEM JAMB. <br />FASTEN PER FABRICATOR'S SHOP <br />DRAWINGS (TYP.) <br />(E) POST <br />1/2" SEALANT JOINT WITH <br />BACKER ROD (TYP.) <br />3-COAT EXTERIOR PLASTER <br />FINISH SYSTEM <br />1/4" FINISH CAULK <br />JOINT (TYP.) <br />5/8" GYPSUM <br />WALLBOARD. FINISH <br />AS SCHEDULED <br />J-MOLD (TYP.) <br />SELF ADHERED FLEXIBLE <br />FLASHING AROUND OPENING <br />3" = 1'-0"11RAKE AT ROOF1 <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25 <br />1 <br />6" = 1'-0"7ROOF VENT PENETRATION DETAIL
The URL can be used to link to this page
Your browser does not support the video tag.