"V" STRUT <br />OPPOSITE FREE WALLS. <br />FIXTURES GREATER <br />THAN 50 POUNDS, <br />PROVIDE SEPARATE <br />SUPPORT <br />PROVIDE VERTICAL <br />HANGER WIRES @ 48" <br />O.C. ON MAIN RUNNERS <br />PROVIDE <br />COMPRESSION POST <br />AND (4) #12 GA <br />SPLAYED BRACING <br />WIRES @ MAX 12'-0" <br />O.C. ON MAIN <br />RUNNERS AND 6'-0" <br />MAX FROM WALL. <br />PERIMETER <br />STARTER WALLS <br />LAY-IN PANEL, SEE <br />FINISH SCHEDULE <br />FOR TYPE. <br />PANEL SUSPENSION <br />GRID, SEE FINISH <br />SCHEDULE FOR TYPE. <br />6 <br />A64.3 <br />6 <br />A64.3 <br />5 <br />A64.3 <br />SUSPENDED LAY-IN CEILING NOTES: <br />(FOR CEILING SYSTEMS WHOSE TOTAL WEIGHT, INCLUDING AIR CONDITIONING/HEATING GRILLS <br />AND LIGHT FIXTURES, DOES NOT EXCEED 4 PSF) <br />SEE DSA IR 25-2.13 FOR ALL APPLICABLE REQUIREMENTS <br />1. CEILING WIRE SHALL BE CLASS 1 ZINC COATED (GALVANIZED) CARBON STEEL CONFORMING TO <br />ASTM A641.WIRE SHALL BE #12 GA. (MIN.) WIRE SHALL BE SOFT ANNEALED AND MIN. TENSILRE <br />STRENGTH = 70 KSI. MAIN RUNNERS, CROSS RUNNERS, SPLICES, EXPANSION DEVICES, AND <br />INTERSECTION CONNECTORS SHALL BE DESIGNED TO CARYY A MEAN ULTIMATE TEST LOAD OF <br />NOT LESS THAN 180 LBS. IN COMPRESSION AND TENSION PER ASTM E580 SECTION 5.1.2. <br />2. #12 GAGE HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X 4'-0" GRID SPACING <br />AND SHALL BE ATTACHED TO MAIN RUNNERS. <br />3. PROVIDE 12 GA. HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN 8" <br />FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF THE END TEE, WHICHEVER IS LEAST, FOR <br />THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE <br />LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. <br />4. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO <br />TYPICAL HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED <br />AT ALL CEILING BREAKS, SOFFITS, OR DISCONTINUOUS AREAS. HANGER WIRES THAT ARE MORE <br />THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. <br />5. CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS PER ASCE 7-10, <br />SECTION 13.5.6.2(b). CEILING GRID MEMBERS SHALL BE AT LEAST 3/4" CLEAR OF OTHER WALLS. IF <br />WALLS RUN DIAGONALLY TO CEILING GRID MEMBERS, ONE END OF MAIN AND CROSS RUNNERS <br />SHALL BE FREE, AND A MINIMUM OF 3/4" CLEAR OF WALL. <br />6. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2 <br />INCHES. <br />7. AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT <br />CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN RUNNERS AT THE <br />FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A 16 GA WIRE WITH A POSITIVE <br />MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR <br />DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 8" OR LESS, THIS INTERLOCK IS <br />NOT REQUIRED. <br />8. EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS <br />AND AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. <br />9. PROVIDE BRACING ASSEMBLIES CONSISTING OF A COMPRESSION STRUCT AND FOUR (4) #12 <br />GA. SPLAYED BRACING WIRES ORIENTED 90° FROM EACH OTHER. <br />10. LATERAL FORCE BRACING ASSEMBLIES SHALL BE SPACED PER TABLE 1 FOR ALL VALUES OF <br />THE COMPONENT IMPORTANCE FACTOR (IP) OF THE CEILING(PER DSA REQUIREMENTS FOR <br />SCHOOL BUILDINGS PER IR 25-2.13).WHERE, AS DEFINED IN ASCE 7-10, SEC.13.3.1: <br />z= HEIGHT IN STRUCTUR OF POINT ATTACHMENT OF CEILING WITH RESPECT TO THE BASE. <br />h= AVERAGE ROOF HEIGHT OF THE STRUCTURE WITH RESPECT TO THE BASE. <br />PROVIDE BRACING ASSEMBLIES AT LOCATIONS NOT MORE THAN 6'-0" FROM EACH PERIMETER <br />WALL AND AT THE EDGE OF VERTICAL CEILING OFFSETS. THE MAXIMUM SLENDERNESS RATIO <br />(kL/R) OF THE COMPRESSION STRUT IS 200 OR LESS. <br />11. THE SLOPE OF BRACING WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE <br />CEILING AND WIRES SHALL BE TAUT. SPLICES IN WIRES ARE NOT PERMITTED WITHOUT SPECIAL <br />DSA APPROVAL. <br />12. COMPRESSION STRUTS SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF <br />PLUMB. <br />13. SUSPENDED ACOUSICTAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQUARE FEET OR <br />LESS, AND FIRE RATED SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 96 <br />SQUARE FEET OR LESS, SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE <br />ABOVE OR WALLS INDEPENDENTLY BRACED ABOVE CEILING TO STRUCTURE ABOVE, DO NOT <br />REQUIRE BRACING ASSEMBLIES WHEN ATTACHED TO TWO ADJACENT WALLS. <br />14. FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET A SEISMIC SEPARATION JOINT SHALL BE <br />PROVIDED TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING 2500 SQUARE FEET. <br />15. PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES <br />THAT ARE NOT INTEGRALLY TIRED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL <br />HAVE A (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER TO ALLOW FREE MOVEMENT OF (1) INCH <br />IN ALL HORIZONTAL DIRECTIONS. <br />16. FASTEN #12 HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT TURNS. FASTEN #12 <br />BRACING WIRES WITH FOUR (4) TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF <br />1-1/2 INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED <br />IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS AS CLOSELY AS POSSIBLE WITH <br />THE DIRECTION OF THE WIRE. <br />NOTE: WIRE TURNS MADE BY MACHINE WHERE BOTH STRANDS HAVE BEEN DEFORMED OR BENT <br />IN WRAPPING CAN WAIVE THE 1-1/2" REQUIREMENT, BUT THE NUMBER OF TURNS SHOULD BE <br />MAINTAINED, AND BE AS TIGHT AS POSSIBLE. <br />17. SEPARATE ALL CEILING HANGING AND BRACING WIRES AT LEAST SIX (6) INCHES FROM ALL <br />UNBRACED DUCTS, PIPES, CONDUIT, ETC. <br />18. WHEN DRILL-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED <br />CONCRETE FOR HANGER WIRES, 1 OUT OF 10 MUST BE FIELD TESTED FOR 200 POUNDS OF <br />TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 <br />MUST BE FIELD TESTED FOR 440 LBS. OF TENSION. SHOT-IN ANCHORS IN CONCRETE ARE NOT <br />PERMITTED FOR BRACING WIRES. <br />NOTE: DRILLED-IN OR SHOT-IN ANCHORS REQUIRE SPECIAL DSA APPROVAL PRIOR TO USE IN <br />PRESTRESSED CONCRETE. <br />19. ATTACH ALL LIGHT FIXTURES AND CEILING MOUNTED AIR TERMINALS TO THE CEILING GRID <br />RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. SCREWS <br />OR APPROVED FASTENERS ARE REQUIRED (USE TWO #8 SELF-TAPPING TEK SCREWS AT EACH <br />END, OR APPROVED EQUAL). <br />20. FLUSH OR RECESSED LIGHT FIXTURES, WEIGHT LESS THAN 56 LBS, AND MECHANICAL <br />TERMINALS AND SERVICES WIEGHT LESS THAN 20 LBS., MAY BE SUPPORTED DIRECTLY ON THE <br />RUNNERS OF A HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF <br />TWO (2) #12 GA. SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND <br />ANCHORED TO THE STRUCTURE ABOVE. ALL 4'-0" X 4'-0" LIGHT FIXTURES MUST HAVE SLACK <br />SAFETY WIRES AT EACH CORNER. <br />ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING 56 LBS. OR MORE AND MECHANICAL <br />TERMINALS AND SERVICES, WEIGHING 20 LBS. ORE MORE, MUST BE INDEPENDENTLY SUPPORTED <br />BY NOT LESS THAN FOUR (4) TAUT #12 GA. WIRES EACH ATTACHED TO THE FIXTURE AND TO THE <br />STRUCTURE ABOVE. THESE WIRES, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE, <br />MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT. <br />21. SUPPORT SURFACE-MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH <br />SURROUND THE CIELING RUNNER AND WHICH ARE SUPPORTED FROM THE STRUCTURE ABOVE BY <br />A #12 GAGE WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT <br />ACCEPTABLE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE 8 FT OR LONGER. <br />MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED 8 FT. <br />22. N/A <br />23. THE CEILING GRID SYSTEM MUST BE RATED AS HEAVY DUTY AS DEFINED BY ASTM C635. <br />MANUF. CLASS. MAIN RUNNER CROSS RUNNER RUNNER SPLICE <br />ARMSTRONG HD PRELUDE 15/16" (7301) XL7340/XL7328 INTEGRAL TO 7301 <br />CERTAINTEED HD 15/16" CLASSIC (CS1212-20) CS2-12-12/CS4-12-12 DWSC-200 <br />USG HD DX (DX26) DX (DX216/DX424) INTEGRAL TO DX <br />12 GA.HANGER WIRE, SEE NOTES #2 & 7 <br />LAY-IN CEILING PANEL <br />MAIN RUNNER OR CROSS TEE <br />SLOTTED ANGLE "V" STRUT SPACER W/ <br />HORIZ. 6d RING SHANK NAIL THROUGH <br />SLOTS @ RUNNER WHERE OCCURS <br />SEE NOTE #5 <br />FACE OF WALL <br />3/4" <br />WALL ANGLE <br />7/8" <br />M7 7/8" x 7/8" WALL ANGLE FOR DX AND DXT <br />SECURE TO WALL STRUCTURE @ EA. STUD PER <br />NOTE # 5 ON 1/A64.1 <br />ACM-7 SEISMIC CLIP PER ICC ESR-1222 <br />ACM-7 CLIP, (2) #10 - 1-1/4" TEK SCREW <br />TO M7 WALL ANGLE <br />GUIDING SCREW <br />TO COMPLY WITH FIGURE 1 ACM7 CLIP <br />UNRESTRAINED OF ICC ESR-1222 <br />8" MAX. <br />#10 WS - 1 1/4" SCREW, @ EA. STUD <br />12 GA.HANGER WIRE, SEE NOTES #2 & 7 <br />M7 7/8" X 7/8" WALL ANGLE FOR DX AND DXT <br />SECURE TO WALL STRUCTURE @ EA. STUD PER <br />NOTE # 5 ON 1/A64.1 <br />LAY-IN CEILING PANEL <br />MAIN RUNNER OR <br />CROSS TEE <br />8" MAX. <br />FACE OF WALL <br />ACM-7 SEISMIC CLIP PER ICC ESR-1222 <br />@ EACH MAIN RUNNER <br />#10 WS - 1 1/4" SCREW, @ EA. STUD <br />WALL ANGLE <br />7/8" <br />#7 7/8" SCREW <br />TO COMPLY WITH FIGURE 2 ACM7 CLIP <br />RESTRAINED OF ICC ESR-1222 <br />ACM-7 CLIP, (2) #10 - 1-1/4" TEK SCREW <br />TO M7 WALL ANGLE <br />MAX <br />45° TYP. <br />MAIN RUNNER <br />CROSS RUNNER <br />2" <br />1 1/2" MAX <br />1/4" MACHINE BOLT <br />COMPRESSION POST SEE <br />TABLE AND DET. <br />LATERAL FORCING BRACING # <br />12 GA WIRE SECURED TO MAIN <br />RUNNER PER NOTES # 1, #2 & 3 <br />AND CONNECTION TO <br />STRUCTURE PER DETAIL <br />#12 GA VERTICAL <br />HANGER WIRE @ <br />4'-0" <br />4 <br />A64.3 <br />/6 A64.4 <br />/14 A64.4 <br />NOTE: ADDITIONAL <br />CONNECTION DETAILS ON A64.4 <br />6" <br />OV <br />E <br />R <br />L <br />A <br />P <br />1' <br /> <br />- <br /> <br />0 <br />" <br />5" <br />COMPRESSION <br />STRUT. SEE TABLE <br />BELOW <br />SECURE SPLICE <br />SECTIONS TOGETHER <br />WITH (2) #8 X 1" SELF <br />TAPPING SHT. MTL. <br />SCREWS (S.T.S.M.S.) <br />CRIMP BOTTOM FLAT <br />AND ATTACH TO MAIN <br />RUNNER WITH 1/4" <br />DIAM. MACHINE BOLT <br />MAIN RUNNER <br />COMPRESSION POST TABLE <br />FOR TUBING & METAL STUD: <br />1. USE 1/2" DIAM. EMT FOR MAXIMUM <br />LEGNTH UP TO 2'-6" <br />2. USE 3/4" DIAM. EMT FOR MAXIMUM <br />LENGTH UP TO 4'-0" <br />3. USE 1" DIAM. EMT FOR MAXIMUM <br />LENGTH UP TO 5'-6" <br />4. USE 1 1/2" DIA EMT FOR MAXIMUM <br />LENGTH UP TO 8'-6" <br />5. USE 1 5/8" x 25 GA METAL STUDS <br />FOR MAXIMUM LENGTH UP TO 7'-2" <br />6. USE DOUBLE 1 5/8" x 25 GA METAL <br />STUDS FOR MAX. LENGTH UP TO 16'-0" <br />7. USE DOUBLE 2 1/2" x 25 GA METAL <br />STUDS FOR MAX. LENGTH UP TO 17'-0" <br />8. USE DOUBLE 3 5/8" x 25 GA METAL <br />STUDS FOR MAX. LENGTH UP TO 22'-8" <br />C SHAPED METAL STUDS <br />#6 S.T.S.M.S. @ 12" O.C. <br />NOTES: <br />1. COMPRESSION STRUTS SHALL NOT <br />REPLACE HANGER WIRES. <br />2. CEILING NOT SHOWN FOR CLARITY <br />CRIMP TOP OF <br />TUBING FLAT & <br />ATTACH WITH (2) <br />FHWS <br />WOOD BLOCKING <br />BETWEEN JOISTS ABOVE <br />PER STRUCTURAL <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />07/08/24 <br />A64.3 <br />CEILING DETAILS <br />- ACOUSTICAL <br />TILE <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />1 1/2" = 1'-0"2CEILING PLAN DETAIL, TYP. <br />1 1/2" = 1'-0"1CEILING NOTES (LAY-IN PANEL) <br />3" = 1'-0"6CEILING PERIMETER AT FREE WALL <br />3" = 1'-0"5CEILING PERIMETER AT FIXED WALL <br />1 1/2" = 1'-0"3CEILING SPAY WIRE BRACING DETAIL <br />3" = 1'-0"4COMPRESSION STRUT DET. @ ACT <br />1 <br />DESCRIPTION DATE <br />1 ASI #01 04/09/25