AV INPUT/OUTPUT PANEL
<br />CAMERA, WALL-MOUNTED
<br />SPEAKER, WALL-MOUNTED
<br />CAMERA, CEILING-MOUNTED
<br />MICROPHONE, CEILING FLUSH-MOUNTED
<br />SPEAKER, CEILING FLUSH-MOUNTED
<br />TV DISPLAY BACKBOX; COORDINATE WITH ARCHITECTURAL DRAWINGS
<br />PROJECTOR, CEILING-MOUNTED
<br />THREE-SERVICE (POWER-DATA-AV) IN-FLOOR BOX; PROVIDE DEVICES PER PLAN.
<br />SEE ELECTRICAL PLANS AND SPECIFICATIONS FOR MORE INFORMATION.
<br />ASSISTIVE LISTENING ANTENNA/RADIATOR
<br />VIDEO SCREEN UP/DN SWITCH
<br />1.LOUDSPEAKER SPEAKER CABLE, 70-VOLT DISTRIBUTION, PLENUM RATED 2-CONDUCTOR, 16 AWG, UNSHIELDED PAIR: WEST PENN, BELDEN OR
<br />EQUAL.
<br />2.STADIUM LOUD SPEAKER CABLE SHALL BE 8/2 AWG OR 10/2 AWG RATED FOR WATER IMMERSION OR AS SPECIFIED : WEST PENN, BELDEN OR
<br />EQUAL
<br />3.LOUDSPEAKER CABLE, PLENUM RATED 2-CONDUCTOR, 12 AWG, UNSHIELDED PAIR: WEST PENN, BELDEN OR EQUAL.
<br />4.LOUDSPEAKER CABLE, PLENUM RATED 2-CONDUCTOR, 14 AWG, UNSHIELDED PAIR: WEST PENN, BELDEN OR EQUAL.
<br />5.ANALOG MICROPHONE/LINE LEVEL INSTALLATION CABLE, 22 AWG CONDUCTOR, JACKETED, SHIELDED, TWISTED-PAIR, PLENUM RATED: WEST
<br />PENN, BELDEN OR EQUAL.
<br />6.PRE-TERMINATED HDMI, DVI DISPLAY PORT CABLES: EXTRON, OR EQUAL. (NOTE, CABLES MUST BE RATED FOR HDMI 2.0 SPECIFICATIONS OR
<br />BETTER, CAPABLE OF PASSING UHD AND 4K RESOLUTION AT DISTANCES LESS THAN 35' WITHOUT AN ACTIVE EQUALIZER.)
<br />7.DIGITAL VIDEO SWITCHER, EXTRON XTP/DTP 24, OR CRESTRON ULTRA SHIELDED TWISTED PAIR CABLE. . WITH EXTRON OR CRESTRON ONLY
<br />SHIELDED RJ-45 CONNECTORS.
<br />8.CONTROL SYSTEM DEVICE CONTROL (RS232, RELAY OR CONTACT CLOSURE): (DUAL 22 AWG SHIELDED TWISTED PAIRS W ITH INDIVIDUAL DRAIN
<br />WIRES, EACH PAIR IS COLOR-CODED RED/BLACK AND GREEN/WHITE TO SIMPLIFY IDENTIFICATION.) PLENUM RATED: WEST PENN, BELDEN OR
<br />EQUIVALENT.
<br />9.DATA NETWORK: PLENUM-RATED CATEGORY 6, SEE STRUCTURED CABLING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
<br />10.SERIAL DIGITAL INTERFACE CABLE RG6, 75 OHM COAXIAL CABLE BELDEN 4694R OR EQUAL.
<br />11.FIBER, OM4. MM, 50 MICRON WITH LC CONNECTIONS PER EXTRON OR CRESTRON SPECIFICATIONS. FIBER, SINGLE MODE. PROVIDE
<br />CONNECTORS AS SHOWN. PROVIDE PLENUM RATED CABLE FOR ALL CABLE WHERE REQUIRED BY CODE. PROVIDE CABLE RATED FOR WATER
<br />IMMERSION AS REQUIRED OR AS SPECIFIED
<br />12.ANY CABLE CHANGES OR SUBSTITUTIONS MUST BE SUBMITTED AND APPROVED PRIOR TO INSTALLATION. NON-COMPLIANT CABLE THAT HAS
<br />BEEN INSTALLED WITHOUT APPROVAL SHALL BE REPLACED AT THE CONTRACTOR EXPENSE.
<br />1.PROVIDE PORTABLE OR PERMANENT ASSISTIVE LISTENING SYSTEMS BY LISTEN TECHNOLOGIES OR EQUIVALENT
<br />AS SPECIFIED HEREIN.
<br />2.SEE SPECIFICATION SECTION 274116 FOR MORE INFORMATION.
<br />3.ALS SYSTEM SHALL PROVIDE AMPLIFICATION WITHIN A ROOM FOR INDIVIDUALS WITH NORMAL HEARING AND FOR
<br />THOSE WITH MINIMUM TO MILD HEARING LOSS IN 10 TO 25 dB RANGE.
<br />4.THE RECEIVERS SHALL BE ABLE TO AMPLIFY THE SPEAKER'S VOICE 20 dB ABOVE ROOM NOISE. THEY SHALL HAVE
<br />AN AUXILIARY INPUT JACK TO BROADCAST EXTERNAL SOUNDS FROM AN AUDIBLE DEVICE OR TELEVISION. THE
<br />RECEIVERS SHALL HAVE AN AUXILIARY VOLUME CONTROL TO CONTROL THE SOUND LEVEL OF INPUT RECEIVED
<br />FROM EXTERNAL SOURCES. THE UNITS SHALL HAVE AN FM VOLUME CONTROL TO ALLOW FOR ADJUSTMENT OF
<br />THE SOUND LEVEL OF THE FM SIGNAL RECEIVED FROM THE WIRELESS TRANSMITTER. THE RECEIVER MUST HAVE
<br />A TONE CONTROL TO ADJUST THE FREQUENCY RESPONSE FOR A VARIETY OF USERS AND LISTENING
<br />ENVIRONMENTS. THEY SHALL HAVE COLOR-CODED SPEAKER OUTPUT TERMINALS AND MUST BE CAPABLE OF
<br />RECEIVING ANY OF 40 FCC AND INDUSTRY CANADA APPROVED NARROW BAND CHANNEL IN THE 72 TO 76 MHz
<br />RANGE.
<br />5.PROVIDE TRANSMITTERS AND RECEIVERS WITH RECHARGEABLE BATTERIES.
<br />6.LISTENING ACCESSORIES AND CHARGING UNITS EQUAL TO 4% OF THE TOTAL SEATING OF ALL CLASSROOMS BUT
<br />NO LESS THAN A QUANTITY OF TWO PER CLASSROOM, LA-323 OR LA-325 AS REQUIRED. 25% OF ALL RECEIVERS
<br />TO BE HEARING AID COMPATIBLE. REFER TO ARCHITECTURAL FLOOR PLANS FOR MINIMUM OCCUPANCY SEATING.
<br />NUMBER OF TRANSMITTERS SHALL ACCOMMODATE REQUIRED NUMBER OF RECEIVERS.
<br />ALL PULL BOXES SHALL BE SIZED AND INSTALLED PER ANSI-TIA-569-C. PULL BOXES FOR IN/UNDER SLAB
<br />CONDUIT
<br />RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULL BOXES FOR OVERHEAD CONDUIT RUNS SHALL
<br />BE
<br />LOCATED ABOVE ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING SPACE AND SUPPORTED
<br />INDEPENDENTLY FROM THE STRUCTURE AND CONDUIT SUPPORTS. PULL BOXES FOR ROOF MOUNTED OR
<br />EXTERIOR ABOVE GRADE APPLICATIONS SHALL BE NEMA 3R RATED.
<br />PJ
<br />C
<br />M
<br />S
<br />ANNOTATIONS
<br />X
<br />X-X
<br />2
<br />1.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT. JUNCTION BOXES, CABLE TRAYS, COVER PLATES, PULL STRING, ENCLOSURES,
<br />FLOOR BOXES, POWER RECEPTACLES AND POWER CONNECTIONS IDENTIFIED IN THESE DRAWINGS AND SPECIFICATIONS. UNLESS
<br />OTHERWISE NOTED.
<br />2.ALL JUNCTION BOXES IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED. CONDUITS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.
<br />3.ALL AUDIO-VISUAL CONDUIT RUNS SHALL BE CONTINUOUS FROM END TO END. NO CONDUIT RUNS SHALL EXCEED 100 FEET. ALL CONDUIT
<br />RUNS EXCEEDING 100 FEET MUST HAVE LARGE RADIUS BENDS. TOTAL BENDS PER RUN IS 360 DEGREES.
<br />4.GENERAL CONTRACTOR SHALL PROVIDE STRUCTURAL SUPPORT FOR MOUNTING OF AUDIO-VISUAL EQUIPMENT PROVIDED BY OTHERS AT
<br />LOCATIONS DESIGNATED IN THESE DRAWINGS. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, BLOCKING FOR WALL MOUNTED DEVICES AND
<br />OVERHEAD SUPPORT FOR CEILING MOUNTED PROJECTORS AND PROJECTION SCREENS.
<br />5.REFER TO ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS FOR SUPPORT DETAILS AND REQUIREMENTS.
<br />6.DIMENSIONS ARE INDICATED ON AUDIOVISUAL DRAWINGS WHERE CRITICAL TO THE INSTALLATION AND PERFORMANCE OF THE AUDIOVISUAL
<br />DEVICES. WHERE INFORMATION AND REQUIREMENTS CONFLICT WITH SPECIFICATIONS AND DESIGNS DELINEATED ELSEWHERE, THE GENERAL
<br />CONTRACTOR SHALL IMMEDIATELY BRING SUCH CONFLICTS TO THE ATTENTION OF THE ARCHITECT.
<br />7.THE ARCHITECTURAL, FURNITURE AND FINISH CONFIGURATIONS ILLUSTRATED ON THE AUDIOVISUAL DRAWINGS ARE FOR REFERENCE ONLY.
<br />REFER TO THE ARCHITECTURAL DRAWINGS FOR SPECIFICATIONS AND REQUIREMENTS.
<br />8.ALL EQUIPMENT INSTALLATION AND MOUNTING DETAILS PROVIDED IN THE AUDIO-VISUAL DRAWINGS ARE FOR REFERENCE ONLY. REFER TO
<br />ARCHITECTURAL AND ENGINEERING DRAWINGS FOR SPECIFIC REQUIREMENTS.
<br />9.DATA/COMMUNICATION OUTLETS AND POWER OUTLETS ARE SHOWN FOR REFERENCE ONLY. REFER TO THE TELECOMMUNICATION DRAWINGS
<br />FOR EXACT LOCATION OF THE DATA/COMMUNICATION OUTLETS AND TO THE ELECTRICAL DRAWINGS FOR THE EXACT LOCATION OF THE
<br />POWER RECEPTACLES.
<br />10.CEILING MOUNTED SPEAKER ENCLOSURES SHALL BE SUPPORTED FROM OVERHEAD STRUCTURE. DO NOT HANG SPEAKER ENCLOSURES
<br />FROM FINISHED CEILING.
<br />11.GENERAL CONTRACTOR SHALL PROVIDE PULL STRINGS IN ALL CONDUIT SPECIFIED IN AUDIO-VISUAL DRAWINGS. GENERAL CONTRACTOR
<br />SHALL LABEL ALL AUDIO-VISUAL JUNCTION BOXES WITH DESIGNATED BOX ID NUMBER (E.G., AV100).
<br />12.GENERAL CONTRACTOR SHALL PROVIDE BLANK COVER PLATES AT ALL AUDIO-VISUAL JUNCTION BOXES. VERIFY ALL DEVICE PLATE FINISHES
<br />WITH ARCHITECT. COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF ALL AUDIOVISUAL JUNCTION BOXES AND DEVICES WITH ARCHITECT.
<br />13.SOME JUNCTION BOXES AND ENCLOSURES SPECIFIED IN AUDIO-VISUAL DRAWINGS MAY BE DEEPER THAN STANDARD WALL DEPTH.
<br />COORDINATE WITH MANUFACTURER AND/OR ARCHITECT TO VERIFY INSTALLATION REQUIREMENTS AND DETAILING.
<br />14.WHERE SPECIFIED, LOW VOLTAGE CONTROL INTERFACE ELECTRONICS SHALL BE PROVIDED TO ENABLE OPERATION OF LINE VOLTAGE
<br />DEVICES (E.G., PROJECTION SCREENS, LIGHTING, WINDOW COVERINGS) VIA THE AUDIO=VISUAL CONTROL SYSTEM. PROVIDE SERIAL DIGITAL
<br />(E.G., RS232) INTERFACE CONTROL WHERE AVAILABLE WHERE MORE THAN ONE CONDUIT TERMINATES IN A JUNCTION BOX THE ELECTRICAL
<br />CONTRACTOR SHALL LABEL EACH CONDUIT IN A MANNER ALLOWING IDENTIFICATION OF CONDUITS AFTER WALL FINISHES ARE APPLIED.
<br />15.AUDIO-VISUAL INFRASTRUCTURE DIAGRAM IDENTIFY SIGNAL CABLE CONTAINMENT REQUIREMENTS ONLY. AUDIOVISUAL CABLING AND
<br />SPECIALTY CONNECTOR PLATES ARE BY AUDIO-VISUAL CONTRACTOR.
<br />16.ALL CONDUITS SPECIFIED SHALL BE EMT OR RIGID TYPE. FLEXIBLE CONDUITS MAY BE USED IN RUNS OF 72" OR LESS. FLEXIBLE CONDUITS
<br />SHALL NOT BE ALLOWED WHERE ACCESS CANNOT BE PROVIDED TO THE FULL LENGTH OF THE CONDUIT RUN.
<br />17.GENERAL CONTRACTOR TO INSTALL PROJECTION SCREEN HOUSING FOR ALL FUTURE PROJECTION SCREEN LOCATIONS. U.O.N.
<br />18.DEVICE MOUNTING HEIGHT IS TO THE CENTER, UON.
<br />19.POWER RECEPTACLES ARE SHOWN FOR COORDINATION ONLY. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETE POWER LAYOUT AND
<br />CIRCUITING.
<br />20.WHERE SHOWN A TECHNICAL GROUND IS REQUIRED (TGS). PROVIDE AN INSULATED GROUND CONDUCTOR ISOLATED FROM THE BACK
<br />BOX/CONDUIT SYSTEM. THIS GROUND CONDUCTOR WILL ONLY BE TERMINATED AT THE ELECTRICAL PANEL'S DEDICATED TGS GROUND BUSS.
<br />NO OTHER GROUNDS SHALL BE TERMINATED AT THIS TGS GROUND BUSS. LABEL TGS RECEPTACLE WITH THE TGS DESIGNATION AND CIRCUIT
<br />NUMBER.
<br />WIRE TYPE AUDIO, VIDEO, CONTROL CABLES SCHEDULE
<br />GENERAL NOTES:
<br />DETAIL CALLOUT, "x" INDICATES DETAIL NUMBER "AVx-xx" INDICATES
<br />SHEET
<br />NUMBER.
<br />PLAN NOTE REFERENCE, REFER TO NOTES ON SHEET, OR AS DIRECTED.
<br />4 REVISION REFERENCE.
<br />KEYNOTE REFERENCE, REFER TO NOTES ON SHEET, OR AS DIRECTED.4.XXX
<br />AV SYMBOLS
<br />ASSISTIVE LISTENING SYSTEM NOTE:
<br />9
<br />COMMUNICATIONS PATHWAYS
<br />1.CONDUITS SHALL (a) CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98 FT.), AND (b) CONTAIN NO
<br />MORE THAN (2) 90°
<br />2.BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A PULL BOX. SPLIT CONDUITS IN PLACE OF PULL BOXES
<br />ARE UNACCEPTABLE.
<br />3.CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 200 LBS. WITH A MINIMUM OF 5 FEET OF
<br />EXTRA PULL TAPE COILED AT EACH END. CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES THE
<br />INTERNAL CONDUIT DIAMETER FOR CONDUITS 2-INCHES IN DIAMETER OR
<br />4.LESS, AND (b) 10 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS MORE THAN 2-INCHES IN
<br />DIAMETER.
<br />5.TERMINATE CONDUIT STUBS AND SLEEVES THAT PROTRUDE THROUGH STRUCTURAL FLOORS 2-INCHES TO
<br />3-INCHES ABOVE THE FLOOR SURFACE. INSTALL BUSHINGS OR BELL ENDS AS REQUIRED ON ALL CONDUITS.
<br />6.FLEX CONDUIT IS UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC JOINTS
<br />AND/OR IF APPROVED IN WRITING
<br />7.BY THE ENGINEER. ALL UNDER SLAB OR IN-SLAB CONDUITS SHALL BE INSTALLED IN A MANNER THAT
<br />PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS
<br />8.THE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROUND WATER, RAIN WATER OR CONSTRUCTION WATER
<br />IS PREVENTED FROM ENTERING AND/OR REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT OF
<br />COMMUNICATIONS CABLES. SEE ELECTRICAL SPECIFICATIONS, DETAILS AND PLANS FOR ADDITIONAL
<br />CONDUIT SEALING REQUIREMENTS.
<br />AV
<br />C
<br />S
<br />TV
<br />AL
<br />TOUCH PANEL AV CONTROL, WALL-MOUNTEDTP
<br />SS
<br />RESPONSIBILITY MATRIX
<br />1
<br />ID MODEL MANUFACTURER DESCRIPTION UNITS
<br />PROJ-1 EB-PU1008W EPSON CEILING-MOUNTED PROJECTOR, WHITE 1
<br />MNT-1 CMS492C CHIEF 2' x 2' ABOVE-CEILING STORAGE BOX W/ COLUMN DROP 1
<br />SCRN-1 29901LS DA-LITE 133" CEILING-MOUNTED PROJECTION SCREEN (MOTORIZED) 1
<br />WPD-1 SOLSTICE POD MERSIVE BYOD WIRELESS SHARING DEVICE 1
<br />I/O-1 DM-TX-4KZ-100-C-1G-W-T CRESTRON 1-GANG DECORA STYLE HDMI WALL PLATE, WHITE (FOR WALL) 1
<br />I/O-2 DM-TX-4KZ-100-C-1G-B-T CRESTRON 1-GANG DECORA STYLE HDMI WALL PLATE, BLACK (FOR FLOOR BOX) 1
<br />I/O-3 TBD PANELCRAFTERS 1-GANG PLATE FOR AUDIO CONNECTION TO PORTABLE ALS 1
<br />I/O-4 DM-RMC-4KZ-SCALER-C CRESTRON AV-OVER-CAT6 RECEIVER W/ SCALER 1
<br />AVSW-1 DMPS3-4K-250-C CRESTRON AV SWITCHER WITH BUILT-IN CONTROL PROCESSOR 1
<br />WMS-1 SHURE ULX-D 124/85 SHURE WIRELESS MICROPHONE SYSTEM 1
<br />M-1 MXA920 SHURE 2'x2' FLUSH-MOUNTED BEAMFORMING MIC ARRAY 1
<br />S-1 AD-C4T-LP QSC FLUSH-MOUNTED CEILING SPEAKER 6
<br />AMP-1 SPA2-100 QSC 100W 70V AUDIO AMPLIFIER 1
<br />TP-1 TSW-770-W-S CRESTRON WALL-MOUNTED 7" TOUCH CONTROL PANEL 1
<br />CAM-1 RALLY CAMERA LOGITECH 4K PTZ CAMERA (WALL MOUNT INCL'D) 1
<br />TP-1 LOGITECH SWYTCH LOGITECH BYOM "PLUG-AND-DISPLAY" LAPTOP LINK 1
<br />TP-1 LOGITECH TAP LOGITECH MEETING ROOM TOUCH CONTROLLER 1
<br />AVNS-1 GS308PP NETGEAR 8-PORT NETWORK SWITCH WITH PoE 1
<br />TBD TBD LECTERN WITH CABLE CUBBY, GOOSENECK MIC, AND AV RACK RAILS 1
<br />PDU-1 PL-PRO DMC FURMAN RACK MOUNTED POWER SUPPLY 1
<br />PSU-1 NPAC-120-4 LYNTEC RACK MOUNTED POWER SEQUENCER 1
<br />ID MODEL MANUFACTURER DESCRIPTION UNITS
<br />DISP-1 QE85T SAMSUNG 85" COMMERCIAL DISPLAY 1
<br />MNT-1 BT8225 B-TECH ARTICULATING MOUNT 1
<br />MNT-2 PAC527L CHIEF 14"x21" IN-WALL STORAGE BOX 2
<br />WPD-1 SOLSTICE POD MERSIVE BYOD WIRELESS SHARING DEVICE 1
<br />I/O-1 WPD-160 EXTRON 1-GANG WALL PLATE W/ HDMI & USB, WHITE 1
<br />I/O-2 TBD PANELCRAFTERS 1-GANG PLATE FOR AUDIO CONNECTION TO PORTABLE ALS 1
<br />DL-PLUSB3.1AAF-008M LIBERTY AV USB 3.x/2.0 A-AF ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1
<br />HALO-HCP08M LIBERTY AV HDMI ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1
<br />PROC-1 RMC4 CRESTRON COMPACT CONTROL PROCESSOR 1
<br />TP-1 TSW-770-W-S CRESTRON WALL-MOUNTED 7" TOUCH CONTROL PANEL 1
<br />AVNS-1 GS308PP NETGEAR 8-PORT NETWORK SWITCH WITH PoE 1
<br />ID MODEL MANUFACTURER DESCRIPTION UNITS
<br />ALS-1 LS-88-01 LISTEN ASSISTIVE LISTENING SYSTEM, PORTABLE 2
<br />TRANSMITTER/RADIATOR COMBO W/ TRIPOD (INCL'D) 2
<br />IR BODYPACK RECEIVER 4
<br />EAR PHONE/NECK LOOP LANYARD, FOR THOSE W/ HEARING AIDS (INCL'D)4
<br />EAR SPEAKER, FOR THOSE W/O HEARING AIDS (INCL'D) 4
<br />OMNIDIRECTIONAL TABLE MIC (INCL'D) 2
<br />4-PORT USB CHARGER FOR BODYPACK RECEIVER 2
<br />CARRYING CASE 2
<br />ID MODEL MANUFACTURER DESCRIPTION UNITS
<br />DISP-1 QB65R SAMSUNG 65" COMMERCIAL DISPLAY 1
<br />MNT-1 TS525TU CHIEF ARTICULATING MOUNT 1
<br />MNT-2 TA500 CHIEF 34"x22" IN-WALL BOX FOR TS525TU 1
<br />TAS1 CHIEF 1" SPACER KIT FOR TA500 1
<br />CSPBPTA CHIEF STORAGE PANEL FOR TA500 1
<br />WPD-1 SOLSTICE POD MERSIVE BYOD WIRELESS SHARING DEVICE 1
<br />I/O-1 WPD-160 EXTRON 1-GANG WALL PLATE W/ HDMI & USB, WHITE 1
<br />I/O-2 TBD PANELCRAFTERS 1-GANG PLATE FOR AUDIO CONNECTION TO PORTABLE ALS 1
<br />DL-PLUSB3.1AAF-008M LIBERTY AV USB 3.x/2.0 A-AF ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1
<br />HALO-HCP08M LIBERTY AV HDMI ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1
<br />UCSB-1 RALLY BAR LOGITECH ALL-IN-ONE UC SOUNDBAR 1
<br />MNT-3 952-000044 LOGITECH VESA-COMPATIBLE MOUNTING KIT FOR RALLY BAR 1
<br />TP-1 LOGITECH SWYTCH LOGITECH BYOM "PLUG-AND-DISPLAY" LAPTOP LINK 1
<br />TP-1 LOGITECH TAP LOGITECH MEETING ROOM TOUCH CONTROLLER 1
<br />AVNS-1 GS308PP NETGEAR 8-PORT NETWORK SWITCH WITH PoE 1
<br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS
<br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF
<br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY
<br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR
<br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA
<br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018.
<br />SCALE:
<br />REVISIONS:
<br />OW
<br />N
<br />E
<br />R
<br />:
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />
<br />N
<br />A
<br />M
<br />E
<br />:
<br />CL
<br />I
<br />E
<br />N
<br />T
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />:
<br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707
<br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM
<br />DATE ISSUED:
<br />PROJECT NO:
<br />As indicated
<br />04/09/2025
<br />AV0.1
<br />AUDIOVISUAL
<br />LEAD SHEET
<br />2022-40123
<br />CI
<br />T
<br />Y
<br />
<br />O
<br />F
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />NE
<br />W
<br />H
<br />O
<br />P
<br />E
<br />
<br />L
<br />I
<br />B
<br />R
<br />A
<br />R
<br />Y
<br />MO
<br />D
<br />E
<br />R
<br />N
<br />I
<br />Z
<br />A
<br />T
<br />I
<br />O
<br />N
<br />12
<br />2
<br />
<br />N
<br />.
<br />
<br />N
<br />E
<br />W
<br />H
<br />O
<br />P
<br />E
<br />
<br />S
<br />T
<br />.
<br />,
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />DESCRIPTION DATE
<br />1 ASI #1 4/9/25SCALE: 1/8" = 1'-0"1 AV - NOTE PAGE
<br />AV SHEET INDEX
<br />Sheet
<br />Number Sheet Name
<br />AV0.1 AUDIOVISUAL LEAD SHEET
<br />AV1.1 AUDIOVISUAL FLOOR PLAN
<br />AV2.1 AUDIOVISUAL RCP
<br />AV4.1 AUDIOVISUAL ENLARGED PLAN - MULTIPURPOSE
<br />ROOM
<br />AV4.2 AUDIOVISUAL ENLARGED PLAN - INNOVATION
<br />CENTER
<br />AV4.3 AUDIOVISUAL ENLARGED PLAN - MEDIA CENTER
<br />AV52.1 AUDIOVISUAL DETAILS
<br />AV52.2 AUDIOVISUAL BLOCK DIAGRAMS
<br />SCALE: 12" = 1'-0"2 EQUIPMENT LIST, MPR
<br />SCALE: 12" = 1'-0"3 EQUIPMENT LIST, INNOVATION CENTER
<br />SCALE: 12" = 1'-0"5 EQUIPMENT LIST, PORTABLE ALS
<br />SCALE: 12" = 1'-0"4 EQUIPMENT LIST, MEDIA CENTER
<br />AV ROOM SCHEDULING PANELS X
<br />AV CABLE CUBBY / TABLES OR CASEWORK (CUTOUT BY OTHERS)X
<br />MISC.
<br />AV CUSTOM BACK BOXES FOR AV SYSTEMS X INSTALLED BY G.C.
<br />AV STANDARD BACK BOXES, CONDUITS, AND PATHWAY FOR AV SYSTEMS X PROVIDED & INSTALLED BY G.C.
<br />AV BACKING, BLOCKING, AND OTHER STRUCTURAL SUPPORTS X PROVIDED & INSTALLED BY G.C.
<br />AV AV CABLING AND TERMINATIONS X
<br />AV AV EQUIPMENT RACK X
<br />RACKS, CABLING & INFRASTRUCTURE
<br />AV NETWORK SWITCHES FOR AV SYSTEMS X
<br />AV AV CONTROL PANELS X
<br />CONTROL SYSTEMS
<br />AV ASSISTIVE LISTENING SYSTEMS (ALS)X
<br />AV SPEAKERS CONNECTED TO A ROOM-BASED AV SYSTEM X
<br />AUDIO SYSTEMS
<br />AV DIGITAL SIGNAGE / VIDEO WALL CONTENT X
<br />AV CONTENT DEVICE / MEDIA PLAYER X
<br />AV AV INPUT AND AV OUTPUT PANELS X
<br />AV COMPUTERS DIRECTLY CONNECTED TO THE AV SYSTEM X
<br />VIDEO SYSTEMS
<br />AV PROJECTION SCREENS X PROVIDED & INSTALLED BY G.C.
<br />AV MOUNTS, PROJECTORS, FLAT PANEL DISPLAYS, AND VIDEO WALLS X
<br />DISPLAYS
<br />DISP DEVICE OFOI OFCI CFCI CFOI NOTES
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
|