Laserfiche WebLink
AV INPUT/OUTPUT PANEL <br />CAMERA, WALL-MOUNTED <br />SPEAKER, WALL-MOUNTED <br />CAMERA, CEILING-MOUNTED <br />MICROPHONE, CEILING FLUSH-MOUNTED <br />SPEAKER, CEILING FLUSH-MOUNTED <br />TV DISPLAY BACKBOX; COORDINATE WITH ARCHITECTURAL DRAWINGS <br />PROJECTOR, CEILING-MOUNTED <br />THREE-SERVICE (POWER-DATA-AV) IN-FLOOR BOX; PROVIDE DEVICES PER PLAN. <br />SEE ELECTRICAL PLANS AND SPECIFICATIONS FOR MORE INFORMATION. <br />ASSISTIVE LISTENING ANTENNA/RADIATOR <br />VIDEO SCREEN UP/DN SWITCH <br />1.LOUDSPEAKER SPEAKER CABLE, 70-VOLT DISTRIBUTION, PLENUM RATED 2-CONDUCTOR, 16 AWG, UNSHIELDED PAIR: WEST PENN, BELDEN OR <br />EQUAL. <br />2.STADIUM LOUD SPEAKER CABLE SHALL BE 8/2 AWG OR 10/2 AWG RATED FOR WATER IMMERSION OR AS SPECIFIED : WEST PENN, BELDEN OR <br />EQUAL <br />3.LOUDSPEAKER CABLE, PLENUM RATED 2-CONDUCTOR, 12 AWG, UNSHIELDED PAIR: WEST PENN, BELDEN OR EQUAL. <br />4.LOUDSPEAKER CABLE, PLENUM RATED 2-CONDUCTOR, 14 AWG, UNSHIELDED PAIR: WEST PENN, BELDEN OR EQUAL. <br />5.ANALOG MICROPHONE/LINE LEVEL INSTALLATION CABLE, 22 AWG CONDUCTOR, JACKETED, SHIELDED, TWISTED-PAIR, PLENUM RATED: WEST <br />PENN, BELDEN OR EQUAL. <br />6.PRE-TERMINATED HDMI, DVI DISPLAY PORT CABLES: EXTRON, OR EQUAL. (NOTE, CABLES MUST BE RATED FOR HDMI 2.0 SPECIFICATIONS OR <br />BETTER, CAPABLE OF PASSING UHD AND 4K RESOLUTION AT DISTANCES LESS THAN 35' WITHOUT AN ACTIVE EQUALIZER.) <br />7.DIGITAL VIDEO SWITCHER, EXTRON XTP/DTP 24, OR CRESTRON ULTRA SHIELDED TWISTED PAIR CABLE. . WITH EXTRON OR CRESTRON ONLY <br />SHIELDED RJ-45 CONNECTORS. <br />8.CONTROL SYSTEM DEVICE CONTROL (RS232, RELAY OR CONTACT CLOSURE): (DUAL 22 AWG SHIELDED TWISTED PAIRS W ITH INDIVIDUAL DRAIN <br />WIRES, EACH PAIR IS COLOR-CODED RED/BLACK AND GREEN/WHITE TO SIMPLIFY IDENTIFICATION.) PLENUM RATED: WEST PENN, BELDEN OR <br />EQUIVALENT. <br />9.DATA NETWORK: PLENUM-RATED CATEGORY 6, SEE STRUCTURED CABLING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />10.SERIAL DIGITAL INTERFACE CABLE RG6, 75 OHM COAXIAL CABLE BELDEN 4694R OR EQUAL. <br />11.FIBER, OM4. MM, 50 MICRON WITH LC CONNECTIONS PER EXTRON OR CRESTRON SPECIFICATIONS. FIBER, SINGLE MODE. PROVIDE <br />CONNECTORS AS SHOWN. PROVIDE PLENUM RATED CABLE FOR ALL CABLE WHERE REQUIRED BY CODE. PROVIDE CABLE RATED FOR WATER <br />IMMERSION AS REQUIRED OR AS SPECIFIED <br />12.ANY CABLE CHANGES OR SUBSTITUTIONS MUST BE SUBMITTED AND APPROVED PRIOR TO INSTALLATION. NON-COMPLIANT CABLE THAT HAS <br />BEEN INSTALLED WITHOUT APPROVAL SHALL BE REPLACED AT THE CONTRACTOR EXPENSE. <br />1.PROVIDE PORTABLE OR PERMANENT ASSISTIVE LISTENING SYSTEMS BY LISTEN TECHNOLOGIES OR EQUIVALENT <br />AS SPECIFIED HEREIN. <br />2.SEE SPECIFICATION SECTION 274116 FOR MORE INFORMATION. <br />3.ALS SYSTEM SHALL PROVIDE AMPLIFICATION WITHIN A ROOM FOR INDIVIDUALS WITH NORMAL HEARING AND FOR <br />THOSE WITH MINIMUM TO MILD HEARING LOSS IN 10 TO 25 dB RANGE. <br />4.THE RECEIVERS SHALL BE ABLE TO AMPLIFY THE SPEAKER'S VOICE 20 dB ABOVE ROOM NOISE. THEY SHALL HAVE <br />AN AUXILIARY INPUT JACK TO BROADCAST EXTERNAL SOUNDS FROM AN AUDIBLE DEVICE OR TELEVISION. THE <br />RECEIVERS SHALL HAVE AN AUXILIARY VOLUME CONTROL TO CONTROL THE SOUND LEVEL OF INPUT RECEIVED <br />FROM EXTERNAL SOURCES. THE UNITS SHALL HAVE AN FM VOLUME CONTROL TO ALLOW FOR ADJUSTMENT OF <br />THE SOUND LEVEL OF THE FM SIGNAL RECEIVED FROM THE WIRELESS TRANSMITTER. THE RECEIVER MUST HAVE <br />A TONE CONTROL TO ADJUST THE FREQUENCY RESPONSE FOR A VARIETY OF USERS AND LISTENING <br />ENVIRONMENTS. THEY SHALL HAVE COLOR-CODED SPEAKER OUTPUT TERMINALS AND MUST BE CAPABLE OF <br />RECEIVING ANY OF 40 FCC AND INDUSTRY CANADA APPROVED NARROW BAND CHANNEL IN THE 72 TO 76 MHz <br />RANGE. <br />5.PROVIDE TRANSMITTERS AND RECEIVERS WITH RECHARGEABLE BATTERIES. <br />6.LISTENING ACCESSORIES AND CHARGING UNITS EQUAL TO 4% OF THE TOTAL SEATING OF ALL CLASSROOMS BUT <br />NO LESS THAN A QUANTITY OF TWO PER CLASSROOM, LA-323 OR LA-325 AS REQUIRED. 25% OF ALL RECEIVERS <br />TO BE HEARING AID COMPATIBLE. REFER TO ARCHITECTURAL FLOOR PLANS FOR MINIMUM OCCUPANCY SEATING. <br />NUMBER OF TRANSMITTERS SHALL ACCOMMODATE REQUIRED NUMBER OF RECEIVERS. <br />ALL PULL BOXES SHALL BE SIZED AND INSTALLED PER ANSI-TIA-569-C. PULL BOXES FOR IN/UNDER SLAB <br />CONDUIT <br />RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULL BOXES FOR OVERHEAD CONDUIT RUNS SHALL <br />BE <br />LOCATED ABOVE ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING SPACE AND SUPPORTED <br />INDEPENDENTLY FROM THE STRUCTURE AND CONDUIT SUPPORTS. PULL BOXES FOR ROOF MOUNTED OR <br />EXTERIOR ABOVE GRADE APPLICATIONS SHALL BE NEMA 3R RATED. <br />PJ <br />C <br />M <br />S <br />ANNOTATIONS <br />X <br />X-X <br />2 <br />1.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT. JUNCTION BOXES, CABLE TRAYS, COVER PLATES, PULL STRING, ENCLOSURES, <br />FLOOR BOXES, POWER RECEPTACLES AND POWER CONNECTIONS IDENTIFIED IN THESE DRAWINGS AND SPECIFICATIONS. UNLESS <br />OTHERWISE NOTED. <br />2.ALL JUNCTION BOXES IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED. CONDUITS SHALL BE CONCEALED UNLESS OTHERWISE NOTED. <br />3.ALL AUDIO-VISUAL CONDUIT RUNS SHALL BE CONTINUOUS FROM END TO END. NO CONDUIT RUNS SHALL EXCEED 100 FEET. ALL CONDUIT <br />RUNS EXCEEDING 100 FEET MUST HAVE LARGE RADIUS BENDS. TOTAL BENDS PER RUN IS 360 DEGREES. <br />4.GENERAL CONTRACTOR SHALL PROVIDE STRUCTURAL SUPPORT FOR MOUNTING OF AUDIO-VISUAL EQUIPMENT PROVIDED BY OTHERS AT <br />LOCATIONS DESIGNATED IN THESE DRAWINGS. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, BLOCKING FOR WALL MOUNTED DEVICES AND <br />OVERHEAD SUPPORT FOR CEILING MOUNTED PROJECTORS AND PROJECTION SCREENS. <br />5.REFER TO ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS FOR SUPPORT DETAILS AND REQUIREMENTS. <br />6.DIMENSIONS ARE INDICATED ON AUDIOVISUAL DRAWINGS WHERE CRITICAL TO THE INSTALLATION AND PERFORMANCE OF THE AUDIOVISUAL <br />DEVICES. WHERE INFORMATION AND REQUIREMENTS CONFLICT WITH SPECIFICATIONS AND DESIGNS DELINEATED ELSEWHERE, THE GENERAL <br />CONTRACTOR SHALL IMMEDIATELY BRING SUCH CONFLICTS TO THE ATTENTION OF THE ARCHITECT. <br />7.THE ARCHITECTURAL, FURNITURE AND FINISH CONFIGURATIONS ILLUSTRATED ON THE AUDIOVISUAL DRAWINGS ARE FOR REFERENCE ONLY. <br />REFER TO THE ARCHITECTURAL DRAWINGS FOR SPECIFICATIONS AND REQUIREMENTS. <br />8.ALL EQUIPMENT INSTALLATION AND MOUNTING DETAILS PROVIDED IN THE AUDIO-VISUAL DRAWINGS ARE FOR REFERENCE ONLY. REFER TO <br />ARCHITECTURAL AND ENGINEERING DRAWINGS FOR SPECIFIC REQUIREMENTS. <br />9.DATA/COMMUNICATION OUTLETS AND POWER OUTLETS ARE SHOWN FOR REFERENCE ONLY. REFER TO THE TELECOMMUNICATION DRAWINGS <br />FOR EXACT LOCATION OF THE DATA/COMMUNICATION OUTLETS AND TO THE ELECTRICAL DRAWINGS FOR THE EXACT LOCATION OF THE <br />POWER RECEPTACLES. <br />10.CEILING MOUNTED SPEAKER ENCLOSURES SHALL BE SUPPORTED FROM OVERHEAD STRUCTURE. DO NOT HANG SPEAKER ENCLOSURES <br />FROM FINISHED CEILING. <br />11.GENERAL CONTRACTOR SHALL PROVIDE PULL STRINGS IN ALL CONDUIT SPECIFIED IN AUDIO-VISUAL DRAWINGS. GENERAL CONTRACTOR <br />SHALL LABEL ALL AUDIO-VISUAL JUNCTION BOXES WITH DESIGNATED BOX ID NUMBER (E.G., AV100). <br />12.GENERAL CONTRACTOR SHALL PROVIDE BLANK COVER PLATES AT ALL AUDIO-VISUAL JUNCTION BOXES. VERIFY ALL DEVICE PLATE FINISHES <br />WITH ARCHITECT. COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF ALL AUDIOVISUAL JUNCTION BOXES AND DEVICES WITH ARCHITECT. <br />13.SOME JUNCTION BOXES AND ENCLOSURES SPECIFIED IN AUDIO-VISUAL DRAWINGS MAY BE DEEPER THAN STANDARD WALL DEPTH. <br />COORDINATE WITH MANUFACTURER AND/OR ARCHITECT TO VERIFY INSTALLATION REQUIREMENTS AND DETAILING. <br />14.WHERE SPECIFIED, LOW VOLTAGE CONTROL INTERFACE ELECTRONICS SHALL BE PROVIDED TO ENABLE OPERATION OF LINE VOLTAGE <br />DEVICES (E.G., PROJECTION SCREENS, LIGHTING, WINDOW COVERINGS) VIA THE AUDIO=VISUAL CONTROL SYSTEM. PROVIDE SERIAL DIGITAL <br />(E.G., RS232) INTERFACE CONTROL WHERE AVAILABLE WHERE MORE THAN ONE CONDUIT TERMINATES IN A JUNCTION BOX THE ELECTRICAL <br />CONTRACTOR SHALL LABEL EACH CONDUIT IN A MANNER ALLOWING IDENTIFICATION OF CONDUITS AFTER WALL FINISHES ARE APPLIED. <br />15.AUDIO-VISUAL INFRASTRUCTURE DIAGRAM IDENTIFY SIGNAL CABLE CONTAINMENT REQUIREMENTS ONLY. AUDIOVISUAL CABLING AND <br />SPECIALTY CONNECTOR PLATES ARE BY AUDIO-VISUAL CONTRACTOR. <br />16.ALL CONDUITS SPECIFIED SHALL BE EMT OR RIGID TYPE. FLEXIBLE CONDUITS MAY BE USED IN RUNS OF 72" OR LESS. FLEXIBLE CONDUITS <br />SHALL NOT BE ALLOWED WHERE ACCESS CANNOT BE PROVIDED TO THE FULL LENGTH OF THE CONDUIT RUN. <br />17.GENERAL CONTRACTOR TO INSTALL PROJECTION SCREEN HOUSING FOR ALL FUTURE PROJECTION SCREEN LOCATIONS. U.O.N. <br />18.DEVICE MOUNTING HEIGHT IS TO THE CENTER, UON. <br />19.POWER RECEPTACLES ARE SHOWN FOR COORDINATION ONLY. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETE POWER LAYOUT AND <br />CIRCUITING. <br />20.WHERE SHOWN A TECHNICAL GROUND IS REQUIRED (TGS). PROVIDE AN INSULATED GROUND CONDUCTOR ISOLATED FROM THE BACK <br />BOX/CONDUIT SYSTEM. THIS GROUND CONDUCTOR WILL ONLY BE TERMINATED AT THE ELECTRICAL PANEL'S DEDICATED TGS GROUND BUSS. <br />NO OTHER GROUNDS SHALL BE TERMINATED AT THIS TGS GROUND BUSS. LABEL TGS RECEPTACLE WITH THE TGS DESIGNATION AND CIRCUIT <br />NUMBER. <br />WIRE TYPE AUDIO, VIDEO, CONTROL CABLES SCHEDULE <br />GENERAL NOTES: <br />DETAIL CALLOUT, "x" INDICATES DETAIL NUMBER "AVx-xx" INDICATES <br />SHEET <br />NUMBER. <br />PLAN NOTE REFERENCE, REFER TO NOTES ON SHEET, OR AS DIRECTED. <br />4 REVISION REFERENCE. <br />KEYNOTE REFERENCE, REFER TO NOTES ON SHEET, OR AS DIRECTED.4.XXX <br />AV SYMBOLS <br />ASSISTIVE LISTENING SYSTEM NOTE: <br />9 <br />COMMUNICATIONS PATHWAYS <br />1.CONDUITS SHALL (a) CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98 FT.), AND (b) CONTAIN NO <br />MORE THAN (2) 90° <br />2.BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A PULL BOX. SPLIT CONDUITS IN PLACE OF PULL BOXES <br />ARE UNACCEPTABLE. <br />3.CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 200 LBS. WITH A MINIMUM OF 5 FEET OF <br />EXTRA PULL TAPE COILED AT EACH END. CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES THE <br />INTERNAL CONDUIT DIAMETER FOR CONDUITS 2-INCHES IN DIAMETER OR <br />4.LESS, AND (b) 10 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS MORE THAN 2-INCHES IN <br />DIAMETER. <br />5.TERMINATE CONDUIT STUBS AND SLEEVES THAT PROTRUDE THROUGH STRUCTURAL FLOORS 2-INCHES TO <br />3-INCHES ABOVE THE FLOOR SURFACE. INSTALL BUSHINGS OR BELL ENDS AS REQUIRED ON ALL CONDUITS. <br />6.FLEX CONDUIT IS UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC JOINTS <br />AND/OR IF APPROVED IN WRITING <br />7.BY THE ENGINEER. ALL UNDER SLAB OR IN-SLAB CONDUITS SHALL BE INSTALLED IN A MANNER THAT <br />PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS <br />8.THE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROUND WATER, RAIN WATER OR CONSTRUCTION WATER <br />IS PREVENTED FROM ENTERING AND/OR REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT OF <br />COMMUNICATIONS CABLES. SEE ELECTRICAL SPECIFICATIONS, DETAILS AND PLANS FOR ADDITIONAL <br />CONDUIT SEALING REQUIREMENTS. <br />AV <br />C <br />S <br />TV <br />AL <br />TOUCH PANEL AV CONTROL, WALL-MOUNTEDTP <br />SS <br />RESPONSIBILITY MATRIX <br />1 <br />ID MODEL MANUFACTURER DESCRIPTION UNITS <br />PROJ-1 EB-PU1008W EPSON CEILING-MOUNTED PROJECTOR, WHITE 1 <br />MNT-1 CMS492C CHIEF 2' x 2' ABOVE-CEILING STORAGE BOX W/ COLUMN DROP 1 <br />SCRN-1 29901LS DA-LITE 133" CEILING-MOUNTED PROJECTION SCREEN (MOTORIZED) 1 <br />WPD-1 SOLSTICE POD MERSIVE BYOD WIRELESS SHARING DEVICE 1 <br />I/O-1 DM-TX-4KZ-100-C-1G-W-T CRESTRON 1-GANG DECORA STYLE HDMI WALL PLATE, WHITE (FOR WALL) 1 <br />I/O-2 DM-TX-4KZ-100-C-1G-B-T CRESTRON 1-GANG DECORA STYLE HDMI WALL PLATE, BLACK (FOR FLOOR BOX) 1 <br />I/O-3 TBD PANELCRAFTERS 1-GANG PLATE FOR AUDIO CONNECTION TO PORTABLE ALS 1 <br />I/O-4 DM-RMC-4KZ-SCALER-C CRESTRON AV-OVER-CAT6 RECEIVER W/ SCALER 1 <br />AVSW-1 DMPS3-4K-250-C CRESTRON AV SWITCHER WITH BUILT-IN CONTROL PROCESSOR 1 <br />WMS-1 SHURE ULX-D 124/85 SHURE WIRELESS MICROPHONE SYSTEM 1 <br />M-1 MXA920 SHURE 2'x2' FLUSH-MOUNTED BEAMFORMING MIC ARRAY 1 <br />S-1 AD-C4T-LP QSC FLUSH-MOUNTED CEILING SPEAKER 6 <br />AMP-1 SPA2-100 QSC 100W 70V AUDIO AMPLIFIER 1 <br />TP-1 TSW-770-W-S CRESTRON WALL-MOUNTED 7" TOUCH CONTROL PANEL 1 <br />CAM-1 RALLY CAMERA LOGITECH 4K PTZ CAMERA (WALL MOUNT INCL'D) 1 <br />TP-1 LOGITECH SWYTCH LOGITECH BYOM "PLUG-AND-DISPLAY" LAPTOP LINK 1 <br />TP-1 LOGITECH TAP LOGITECH MEETING ROOM TOUCH CONTROLLER 1 <br />AVNS-1 GS308PP NETGEAR 8-PORT NETWORK SWITCH WITH PoE 1 <br />TBD TBD LECTERN WITH CABLE CUBBY, GOOSENECK MIC, AND AV RACK RAILS 1 <br />PDU-1 PL-PRO DMC FURMAN RACK MOUNTED POWER SUPPLY 1 <br />PSU-1 NPAC-120-4 LYNTEC RACK MOUNTED POWER SEQUENCER 1 <br />ID MODEL MANUFACTURER DESCRIPTION UNITS <br />DISP-1 QE85T SAMSUNG 85" COMMERCIAL DISPLAY 1 <br />MNT-1 BT8225 B-TECH ARTICULATING MOUNT 1 <br />MNT-2 PAC527L CHIEF 14"x21" IN-WALL STORAGE BOX 2 <br />WPD-1 SOLSTICE POD MERSIVE BYOD WIRELESS SHARING DEVICE 1 <br />I/O-1 WPD-160 EXTRON 1-GANG WALL PLATE W/ HDMI & USB, WHITE 1 <br />I/O-2 TBD PANELCRAFTERS 1-GANG PLATE FOR AUDIO CONNECTION TO PORTABLE ALS 1 <br />DL-PLUSB3.1AAF-008M LIBERTY AV USB 3.x/2.0 A-AF ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1 <br />HALO-HCP08M LIBERTY AV HDMI ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1 <br />PROC-1 RMC4 CRESTRON COMPACT CONTROL PROCESSOR 1 <br />TP-1 TSW-770-W-S CRESTRON WALL-MOUNTED 7" TOUCH CONTROL PANEL 1 <br />AVNS-1 GS308PP NETGEAR 8-PORT NETWORK SWITCH WITH PoE 1 <br />ID MODEL MANUFACTURER DESCRIPTION UNITS <br />ALS-1 LS-88-01 LISTEN ASSISTIVE LISTENING SYSTEM, PORTABLE 2 <br />TRANSMITTER/RADIATOR COMBO W/ TRIPOD (INCL'D) 2 <br />IR BODYPACK RECEIVER 4 <br />EAR PHONE/NECK LOOP LANYARD, FOR THOSE W/ HEARING AIDS (INCL'D)4 <br />EAR SPEAKER, FOR THOSE W/O HEARING AIDS (INCL'D) 4 <br />OMNIDIRECTIONAL TABLE MIC (INCL'D) 2 <br />4-PORT USB CHARGER FOR BODYPACK RECEIVER 2 <br />CARRYING CASE 2 <br />ID MODEL MANUFACTURER DESCRIPTION UNITS <br />DISP-1 QB65R SAMSUNG 65" COMMERCIAL DISPLAY 1 <br />MNT-1 TS525TU CHIEF ARTICULATING MOUNT 1 <br />MNT-2 TA500 CHIEF 34"x22" IN-WALL BOX FOR TS525TU 1 <br />TAS1 CHIEF 1" SPACER KIT FOR TA500 1 <br />CSPBPTA CHIEF STORAGE PANEL FOR TA500 1 <br />WPD-1 SOLSTICE POD MERSIVE BYOD WIRELESS SHARING DEVICE 1 <br />I/O-1 WPD-160 EXTRON 1-GANG WALL PLATE W/ HDMI & USB, WHITE 1 <br />I/O-2 TBD PANELCRAFTERS 1-GANG PLATE FOR AUDIO CONNECTION TO PORTABLE ALS 1 <br />DL-PLUSB3.1AAF-008M LIBERTY AV USB 3.x/2.0 A-AF ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1 <br />HALO-HCP08M LIBERTY AV HDMI ACTIVE OPTICAL PLENUM CABLE, 26.24' (8 METERS) 1 <br />UCSB-1 RALLY BAR LOGITECH ALL-IN-ONE UC SOUNDBAR 1 <br />MNT-3 952-000044 LOGITECH VESA-COMPATIBLE MOUNTING KIT FOR RALLY BAR 1 <br />TP-1 LOGITECH SWYTCH LOGITECH BYOM "PLUG-AND-DISPLAY" LAPTOP LINK 1 <br />TP-1 LOGITECH TAP LOGITECH MEETING ROOM TOUCH CONTROLLER 1 <br />AVNS-1 GS308PP NETGEAR 8-PORT NETWORK SWITCH WITH PoE 1 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />04/09/2025 <br />AV0.1 <br />AUDIOVISUAL <br />LEAD SHEET <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DESCRIPTION DATE <br />1 ASI #1 4/9/25SCALE: 1/8" = 1'-0"1 AV - NOTE PAGE <br />AV SHEET INDEX <br />Sheet <br />Number Sheet Name <br />AV0.1 AUDIOVISUAL LEAD SHEET <br />AV1.1 AUDIOVISUAL FLOOR PLAN <br />AV2.1 AUDIOVISUAL RCP <br />AV4.1 AUDIOVISUAL ENLARGED PLAN - MULTIPURPOSE <br />ROOM <br />AV4.2 AUDIOVISUAL ENLARGED PLAN - INNOVATION <br />CENTER <br />AV4.3 AUDIOVISUAL ENLARGED PLAN - MEDIA CENTER <br />AV52.1 AUDIOVISUAL DETAILS <br />AV52.2 AUDIOVISUAL BLOCK DIAGRAMS <br />SCALE: 12" = 1'-0"2 EQUIPMENT LIST, MPR <br />SCALE: 12" = 1'-0"3 EQUIPMENT LIST, INNOVATION CENTER <br />SCALE: 12" = 1'-0"5 EQUIPMENT LIST, PORTABLE ALS <br />SCALE: 12" = 1'-0"4 EQUIPMENT LIST, MEDIA CENTER <br />AV ROOM SCHEDULING PANELS X <br />AV CABLE CUBBY / TABLES OR CASEWORK (CUTOUT BY OTHERS)X <br />MISC. <br />AV CUSTOM BACK BOXES FOR AV SYSTEMS X INSTALLED BY G.C. <br />AV STANDARD BACK BOXES, CONDUITS, AND PATHWAY FOR AV SYSTEMS X PROVIDED & INSTALLED BY G.C. <br />AV BACKING, BLOCKING, AND OTHER STRUCTURAL SUPPORTS X PROVIDED & INSTALLED BY G.C. <br />AV AV CABLING AND TERMINATIONS X <br />AV AV EQUIPMENT RACK X <br />RACKS, CABLING & INFRASTRUCTURE <br />AV NETWORK SWITCHES FOR AV SYSTEMS X <br />AV AV CONTROL PANELS X <br />CONTROL SYSTEMS <br />AV ASSISTIVE LISTENING SYSTEMS (ALS)X <br />AV SPEAKERS CONNECTED TO A ROOM-BASED AV SYSTEM X <br />AUDIO SYSTEMS <br />AV DIGITAL SIGNAGE / VIDEO WALL CONTENT X <br />AV CONTENT DEVICE / MEDIA PLAYER X <br />AV AV INPUT AND AV OUTPUT PANELS X <br />AV COMPUTERS DIRECTLY CONNECTED TO THE AV SYSTEM X <br />VIDEO SYSTEMS <br />AV PROJECTION SCREENS X PROVIDED & INSTALLED BY G.C. <br />AV MOUNTS, PROJECTORS, FLAT PANEL DISPLAYS, AND VIDEO WALLS X <br />DISPLAYS <br />DISP DEVICE OFOI OFCI CFCI CFOI NOTES <br />1 <br />1 <br />1 <br />1 <br />1 <br />1